Krabbe disease (KD) is part of newborn screening (NBS) in 11 states with at least one additional state preparing to screen. In July 2021, KD was re-nominated for addition to the federal Recommended Uniform Screening Panel (RUSP) in the USA with a two-tiered strategy based on psychosine (PSY) as the determinant if an NBS result is positive or negative after a first-tier test revealed decreased galactocerebrosidase activity. Nine states currently screening for KD include PSY analysis in their screening strategy. However, the nomination was rejected in February 2023 because of perceived concerns about a high false positive rate, potential harm to newborns with an uncertain prognosis, and inadequate data on presymptomatic treatment benefit or harm. To address the concern about false positive NBS results, a survey was conducted of the eight NBS programs that use PSY and have been screening for KD for at least 1 year. Seven of eight states responded. We found that: (1) the use of PSY is variable; (2) when modeling the data based on the recommended screening strategy for KD, and applying different cutoffs for PSY, each state could virtually eliminate false positive results without major impact on sensitivity; (3) the reason for the diverse strategies appears to be primarily the difficulty of state programs to adjust screening algorithms due to the concern of possibly missing even an adult-onset case following a change that focuses on infantile and early infantile KD. Contracts with outside vendors and the effort/cost of making changes to a program’s information systems can be additional obstacles. We recommend that programs review their historical NBS outcomes for KD with their advisory committees and make transparent decisions on whether to accept false positive results for such a devastating condition or to adjust their procedures to ensure an efficient, effective, and manageable NBS program for KD.
A-219 A Multiplexed Targeted Assay for Gangliosides Using Liquid Chromatography-Tandem Mass Spectrometry
Abstract Background Gangliosides are a family of complex lipids that are molecules composed of glycosphingolipid with one or more sialic acid linked on the sugar moieties. Gangliosides are recognized to play an important role in many biological processes and the alterations in ganglioside profiles have been observed in some neurodegenerative diseases, neuropathies and lysosomal disorders. Gangliosidoses are a group of inherited lysosomal enzyme deficiencies characterized by an accumulation of incompletely degraded gangliosides in the lysosome. While the diagnosis of gangliosidoses can be accomplished by measurement of enzymatic activities and/or molecular genetic testing, biomarker analysis could facilitate monitoring affected patients, including those enrolled in clinical trials of new treatment approaches (ie., substrate reduction or gene therapies). We developed a rapid and sensitive LC-MS/MS assay that allows simultaneous quantification of multiple gangliosides and other glycosphingolipids and tested it in serum and plasma of patients with a diagnosis of GM2-gangliosidosis. Methods Gangliosides and other glycosphingolipids were extracted from 20 µL serum or plasma using chloroform:methanol (1:2, v/v). A multiplexed LC-MS/MS assay was developed that targeted several ganglioside species (GM3, GM2, GM1, GD3, GD2, GD1, GT3, GT2, GT1 and GQ1) along with several glycosphingolipid species (GlcCer, LacCer, Gb3, Gb4 and GA2). This assay was performed on a triple quadrupole mass spectrometer with scheduled MRM in both negative and positive ion modes after internal standards (GM3 18:0-d5, GM1 17:0, GA2 17:0 and Gb3 18:0-d3) were spiked into clinical samples. Results The multiplexed targeted assay applied to serum and plasma from controls (47 and 49 samples, respectively) and three GM2-gangliosidosis patients for identification and quantification of the targeted gangliosides and other glycosphingolipids. The abundance of GM2 and GM1 gangliosides inserum and plasma of patients with GM2-gangliosidosis was significantly higher than in the control group (P < 0.0001) whereas GM3 levels were significantly lower (P < 0.005). Other gangliosides including GD3, GD2, GD1 and GT1 and glycosphingolipids such as GlcCer, LacCer and Gb3 were not significantly different between these patients and controls. Conclusion A multiplexed targeted assay for glycosphingolipids including gangliosides was developed. This assay will be further validated for potential use in the diagnosis and monitoring of patients with additional gangliosidoses.
A new test method for biochemical analysis of plasmalogens in dried blood spots and erythrocytes from patients with peroxisomal disorders
AbstractMeasurement of plasmalogens is useful for the biochemical diagnosis of rhizomelic chondrodysplasia punctata (RCDP) and is also informative for Zellweger spectrum disorders (ZSD). We have developed a test method for the simultaneous quantitation of C16:0, C18:0, and C018:1 plasmalogen (PG) species and their corresponding fatty acids (FAs) in dried blood spots (DBS) and erythrocytes (RBC) by using capillary gas chromatography–mass spectrometry. Normal reference ranges for measured markers and 10 calculated ratios were established by the analysis of 720 and 473 unaffected DBS and RBC samples, respectively. Determination of preliminary disease ranges was made by using 45 samples from 43 unique patients: RCDP type 1 (DBS: 1 mild, 17 severe; RBC: 1 mild, 6 severe), RCDP type 2 (DBS: 2 mild, 1 severe; RBC: 2 severe), RCDP type 3 (DBS: 1 severe), RCDP type 4 (RBC: 2 severe), and ZSD (DBS: 3 severe; RBC: 2 mild, 7 severe). Postanalytical interpretive tools in Collaborative Laboratory Integrated Reports (CLIR) were used to generate an integrated score and a likelihood of disease. In conjunction with a review of clinical phenotype, phytanic acid, and very long‐chain FA test results, the CLIR analysis allowed for differentiation between RCDP and ZSD. Data will continue to be gathered to improve CLIR analysis as more samples from affected patients with variable disease severity are analyzed. The addition of DBS analysis of PGs may allow for at‐home specimen collection and second‐tier testing for newborn screening programs.
Abstract Background Large β-globin gene cluster deletions (hereditary persistence of fetal hemoglobin [Hb] or β-, δβ-, γδβ-, and ϵγδβ-thalassemia), are associated with widely disparate phenotypes, including variable degrees of microcytic anemia and Hb F levels. When present, increased Hb A2 is used as a surrogate marker for β-thalassemia. Notably, ϵγδβ-thalassemias lack the essential regulatory locus control region (LCR) and cause severe transient perinatal anemia but normal newborn screen (NBS) results and Hb A2 levels. Herein, we report a novel deletion of the ϵ, Aγ, Gγ, and ψβ loci with intact LCR, δ-, and β-regions in 2 women and newborn twins. Methods Capillary electrophoresis (CE), high-performance liquid chromatography (HPLC), DNA sequencing, multiplex ligation-dependent probe amplification (MLPA), gap-polymerase chain reaction (gap-PCR), and long-read sequencing (LRS) were performed. Results NBS showed an Hb A > Hb F pattern for both twins. At 20 months, Hb A2 was increased similarly to that in the mother and an unrelated woman. Unexplained microcytosis was absent and the twins lacked severe neonatal anemia. MLPA, LRS, and gap-PCR confirmed a 32 599 base pair deletion of ϵ (HBE1) through ψβ (HBBP1) loci. Conclusions This deletion represents a hemoglobinopathy category with a distinct phenotype that has not been previously described, an ϵγ-thalassemia. Both the NBS Hb A > F pattern and the subsequent increased Hb A2 without microcytosis are unusual. A similar deletion should be considered when this pattern is encountered and appropriate test methods selected for detection. Knowledge of the clinical impact of this new category will improve genetic counselling, with distinction from the severe transient anemia associated with ϵγδβ-thalassemia.
Liquid Chromatography–Tandem Mass Spectrometry in Newborn Screening Laboratories
Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time.
Identification of Decreased Butyrylcholinesterase in Sudden Infant Death Syndrome Is, at Best, a First Step Toward Preventive Screening
Krabbe disease (KD) is a rare inherited neurodegenerative disorder caused by a deficiency in galactocerebrosidase enzyme activity, which can present in early infancy, requiring an urgent referral for hematopoietic stem cell transplantation, or later in life. Newborn screening (NBS) for KD requires identification and risk-stratification of patients based on laboratory values to predict disease onset in early infancy or later in life. The biomarker psychosine plays a key role in NBS algorithms to ascertain probability of early-onset disease. This report describes a patient who was screened positive for KD in New York State, had a likely pathogenic genotype, and showed markedly reduced enzyme activity but surprisingly low psychosine levels. The patient ultimately developed KD in late infancy, an outcome not clearly predicted by existing NBS algorithms. It remains critical that psychosine levels be evaluated alongside genotype, enzyme activity levels, and the patient’s evolving clinical presentation, ideally in consultation with experts in KD, in order to guide diagnosis and plans for monitoring.
A new D‐galactose treatment monitoring index for PGM1‐CDG
AbstractPhosphoglucomutase 1 (PGM1) catalyzes the interconversion of glucose‐6‐phosphate to glucose‐1‐phosphate and is a key enzyme of glycolysis, glycogenesis, and glycogenolysis. PGM1 deficiency (OMIM: 614921) was initially defined as a glycogen storage disorder (type XIV), and later re‐classified as a PGM1‐congenital disorder of glycosylation (PGM1‐CDG). Serum transferrin (Tf) glycan isoform analysis by liquid chromatography‐mass spectrometry (LC‐MS) is used as a primary diagnostic screen tool, and reveals a very unique CDG profile described as a mixture of CDG‐type I and CDG‐type II patterns. Oral d‐galactose supplementation shows significant clinical and metabolic improvements, which are indicated by the Tf glycan isoform normalization over time in patients with PGM1‐CDG. Thus, there is a need for biomarkers to guide d‐galactose dosage in patients in order to maintain effective and safe drug levels. Here, we present a simplified algorithm called PGM1‐CDG Treatment Monitoring Index (PGM1‐TMI) for assessing the response of PGM1‐CDG patients to d‐galactose supplementation. For our single‐center cohort of 16 PGM1‐CDG patients, the Tf glycan profile analysis provided the biochemical diagnosis in all of them. In addition, the PGM1‐TMI was reduced in PGM1‐CDG patients under d‐galactose supplementation as compared with their corresponding values before treatment, indicating that glycosylation proceeds towards normalization. PGM1‐TMI allows tracking Tf glycan isoform normalization over time when the patients are on d‐galactose supplementation.
The low excretor phenotype of glutaric acidemia type I is a source of false negative newborn screening results and challenging diagnoses
AbstractBackgroundGlutaric acidemia type I (GA1) is an organic acidemia that is often unrecognized in the newborn period until patients suffer an acute encephalopathic crisis, which can be mistaken for nonaccidental trauma. Presymptomatic identification of GA1 patients is possible by newborn screening (NBS). However, the biochemical “low‐excretor” (LE) phenotype with nearly normal levels of disease metabolites can be overlooked, which may result in untreated disease and irreversible neurological sequelae. The LE phenotype is also a potential source of false negative (FN) NBS results that merits further investigation.MethodsSamples from six LE GA1 patients were analyzed by biochemical and molecular methods and newborn screen outcomes were retrospectively investigated.ResultsFive LE GA1 patients were identified that had normal NBS results and three of these presented clinically with GA1 symptoms. One additional symptomatic patient was identified who did not undergo screening. Semiquantitative urine organic acid analysis was consistent with a GA1 diagnosis in two (33%) of the six patients, while plasma glutarylcarnitine was elevated in four (67%) of the six and urine glutarylcarnitine was elevated in four (80%) of five patients. Five GCDH variants were identified in these patients; three of which have not been previously linked to the biochemical LE phenotype.ConclusionsThe data presented here raise awareness of potential FN NBS results for LE GA1 patients. The LE phenotype is not protective against adverse clinical outcomes, and the possibility of FN NBS results calls for high vigilance amongst clinicians, even in the setting of a normal NBS result.