Back to Authors

Tortorelli, Silvia

https://orcid.org/0000-0001-8056-9544

Mayo Clinic

Mayo Clinic

Citations 32

The low excretor phenotype of glutaric acidemia type I is a source of false negative newborn screening results and challenging diagnoses
Guenzel, Adam J. , Scott, Anna I. , Lam, Christina , Chang, Irene J. , Thies, Jenny , Pichurin, Pavel N. , Laxen, William , Raymond, Kimiyo , Gavrilov, Dimitar K. , Oglesbee, Devin , Rinaldo, Piero, Matern, Dietrich , Tortorelli, Silvia , Oglesbee, Devin , Thies, Jenny M , Hall, Patricia , Ferreira, Carlos R

JIMD Reports | April 6, 2021 | Volume: 60 | Issue: 1 | Pages: 67-74

10.1002/jmd2.12217 Get It

AbstractBackgroundGlutaric acidemia type I (GA1) is an organic acidemia that is often unrecognized in the newborn period until patients suffer an acute encephalopathic crisis, which can be mistaken for nonaccidental trauma. Presymptomatic identification of GA1 patients is possible by newborn screening (NBS). However, the biochemical “low‐excretor” (LE) phenotype with nearly normal levels of disease metabolites can be overlooked, which may result in untreated disease and irreversible neurological sequelae. The LE phenotype is also a potential source of false negative (FN) NBS results that merits further investigation.MethodsSamples from six LE GA1 patients were analyzed by biochemical and molecular methods and newborn screen outcomes were retrospectively investigated.ResultsFive LE GA1 patients were identified that had normal NBS results and three of these presented clinically with GA1 symptoms. One additional symptomatic patient was identified who did not undergo screening. Semiquantitative urine organic acid analysis was consistent with a GA1 diagnosis in two (33%) of the six patients, while plasma glutarylcarnitine was elevated in four (67%) of the six and urine glutarylcarnitine was elevated in four (80%) of five patients. Five GCDH variants were identified in these patients; three of which have not been previously linked to the biochemical LE phenotype.ConclusionsThe data presented here raise awareness of potential FN NBS results for LE GA1 patients. The LE phenotype is not protective against adverse clinical outcomes, and the possibility of FN NBS results calls for high vigilance amongst clinicians, even in the setting of a normal NBS result.
Immune dysfunction in MGAT2‐CDG: A clinical report and review of the literature
Poskanzer, Sheri A. , Turgeon, Coleman , Vidal‐Folch, Noemi, Liedtke, Kris L., Oglesbee, Devin , Gavrilov, Dimitar K. , Tortorelli, Silvia , Matern, Dietrich , Rinaldo, Piero, Thies, Jenny , Chang, Irene J. , Beck, Anita E. , Raymond, Kimiyo , Lam, Christina , Turgeon, Coleman T, Vidal-Folch, Noemi, Liedtke, Kris, Bennett, James T , Thies, Jenny M , Chang, Irene J , Beck, Anita E , Raymond, Kimiyo , Allenspach, Eric J , Lam, Christina , Oglesbee, Devin , Poskanzer, Sheri A , Schultz, Matthew , Liedtke, Kristen

American Journal of Medical Genetics Part A | October 12, 2020 | Volume: 185 | Issue: 1 | Pages: 213-218

10.1002/ajmg.a.61914 Get It

AbstractGlycosylation is a critical post/peri‐translational modification required for the appropriate development and function of the immune system. As an example, abnormalities in glycosylation can cause antibody deficiency and reduced lymphocyte signaling, although the phenotype can be complex given the diverse roles of glycosylation. Human MGAT2 encodes N‐acetylglucosaminyltransferase II, which is a critical enzyme in the processing of oligomannose to complex N‐glycans. Complex N‐glycans are essential for immune system functionality, but only one individual with MGAT2‐CDG has been described to have an abnormal immunologic evaluation. MGAT2‐CDG (CDG‐IIa) is a congenital disorder of glycosylation (CDG) associated with profound global developmental disability, hypotonia, early onset epilepsy, and other multisystem manifestations. Here, we report a 4‐year old female with MGAT2‐CDG due to a novel homozygous pathogenic variant in MGAT2, a 4‐base pair deletion, c.1006_1009delGACA. In addition to clinical features previously described in MGAT2‐CDG, she experienced episodic asystole, persistent hypogammaglobulinemia, and defective ex vivo mitogen and antigen proliferative responses, but intact specific vaccine antibody titers. Her infection history has been mild despite the testing abnormalities. We compare this patient to the 15 previously reported patients in the literature, thus expanding both the genotypic and phenotypic spectrum for MGAT2‐CDG.
The Clinical Impact of CLIR Tools toward Rapid Resolution of Post-Newborn Screening Confirmatory Testing for X-Linked Adrenoleukodystrophy in California
Tang, Hao , Matteson, Jamie , Rinaldo, Piero, Tortorelli, Silvia , Currier, Robert J. , Sciortino, Stanley , Currier, Robert , Tortorelli, Silvia

International Journal of Neonatal Screening | August 5, 2020 | Volume: 6 | Issue: 3 | Pages: 62

10.3390/ijns6030062 Get It

Since the start of X-linked adrenoleukodystrophy (ALD) newborn screening in California, more than half of the diagnosed cases were found to have an ATP binding cassette subfamily D member 1 (ABCD1) gene variant of uncertain significance (VUS). To determine retrospectively the likelihood that these were true positive cases, we used a web-based post-analytical tool in Collaborative Laboratory Integrated Reports (CLIR). Confirmatory plasma very long-chain fatty-acids (VLCFA) profiles for ALD screen positive infant boys were run through the CLIR ALD tool. We compared the distribution by ABCD1 variant classification (pathogenic, likely pathogenic, VUS, and no variant) with the CLIR tool score interpretation (non-informative, possibly ALD, likely ALD, and very likely ALD) and the current case diagnosis. The study showed that CLIR tool positive interpretations were consistent with 100% of the pathogenic and likely pathogenic variants on the ABCD1 gene if a more conservative guideline was used. The tool interpretations were also consistent with screened cases that were determined to not have disease (our no-disorder group). The CLIR tool identified 19 diagnosed ALD cases with VUS to be potential false positives, representing a 40% reduction among all diagnosed ALD cases with VUS. The reduction could be extended to 65% if a more aggressive threshold was used. Identifying such preventable false positives could alleviate the follow-up burden for patients, their families, and California Special Care Centers.
A Comparative Effectiveness Study of Newborn Screening Methods for Four Lysosomal Storage Disorders
Sanders, Karen A., Gavrilov, Dimitar K. , Oglesbee, Devin , Raymond, Kimiyo , Tortorelli, Silvia , Hopwood, John J., Lorey, Fred, Majumdar, Ramanath, Kroll, Charles, McDonald, Amber , Lacey, Jean M., Turgeon, Coleman , Tucker, Justin N. , Tang, Hao , Currier, Robert J. , Isaya, Grazia , Rinaldo, Piero, Matern, Dietrich , Raymond, Kimiyo M, Kroll, Charles A, McDonald, Amber M, Turgeon, Coleman T, Oglesbee, Devin , Currier, Robert

International Journal of Neonatal Screening | June 1, 2020 | Volume: 6 | Issue: 2 | Pages: 44

10.3390/ijns6020044 Get It

Newborn screening for one or more lysosomal disorders has been implemented in several US states, Japan and Taiwan by multiplexed enzyme assays using either tandem mass spectrometry or digital microfluidics. Another multiplex assay making use of immunocapture technology has also been proposed. To investigate the potential variability in performance of these analytical approaches, we implemented three high-throughput screening assays for the simultaneous screening for four lysosomal disorders: Fabry disease, Gaucher disease, mucopolysaccharidosis type I, and Pompe disease. These assays were tested in a prospective comparative effectiveness study using nearly 100,000 residual newborn dried blood spot specimens. In addition, 2nd tier enzyme assays and confirmatory molecular genetic testing were employed. Post-analytical interpretive tools were created using the software Collaborative Laboratory Integrated Reports (CLIR) to determine its ability to improve the performance of each assay vs. the traditional result interpretation based on analyte-specific reference ranges and cutoffs. This study showed that all three platforms have high sensitivity, and the application of CLIR tools markedly improves the performance of each platform while reducing the need for 2nd tier testing by 66% to 95%. Moreover, the addition of disease-specific biochemical 2nd tier tests ensures the lowest false positive rates and the highest positive predictive values for any platform.
The Combined Impact of CLIR Post-Analytical Tools and Second Tier Testing on the Performance of Newborn Screening for Disorders of Propionate, Methionine, and Cobalamin Metabolism
Gavrilov, Dimitar K. , Piazza, Amy L. , Pino, Gisele , Turgeon, Coleman , Matern, Dietrich , Oglesbee, Devin , Raymond, Kimiyo , Tortorelli, Silvia , Rinaldo, Piero, Oglesbee, Devin

International Journal of Neonatal Screening | April 13, 2020 | Volume: 6 | Issue: 2 | Pages: 33

10.3390/ijns6020033 Get It

The expansion of the recommend uniform screening panel to include more than 50 primary and secondary target conditions has resulted in a substantial increase of false positive results. As an alternative to subjective manipulation of cutoff values and overutilization of molecular testing, here we describe the performance outcome of an algorithm for disorders of methionine, cobalamin, and propionate metabolism that includes: (1) first tier screening inclusive of the broadest available spectrum of markers measured by tandem mass spectrometry; (2) integration of all results into a score of likelihood of disease for each target condition calculated by post-analytical interpretive tools created byCollaborative Laboratory Integrated Reports (CLIR), a multivariate pattern recognition software; and (3) further evaluation of abnormal scores by a second tier test measuring homocysteine, methylmalonic acid, and methylcitric acid. This approach can consistently reduce false positive rates to a <0.01% level, which is the threshold of precision newborn screening. We postulate that broader adoption of this algorithm could lead to substantial savings in health care expenditures. More importantly, it could prevent the stress and anxiety experienced by many families when faced with an abnormal newborn screening result that is later resolved as a false positive outcome.
Incorporation of Second-Tier Biomarker Testing Improves the Specificity of Newborn Screening for Mucopolysaccharidosis Type I
Peck, Dawn , Lacey, Jean M., White, Amy , Pino, Gisele , Studinski, April, Fisher, Rachel , Ahmad, Ayesha , Viall, Sarah , Shallow, Natalie, Siemon, Amy, Hamm, J. Austin, Murray, Brianna K., Jones, Kelly L. , Gavrilov, Dimitar , Oglesbee, Devin , Raymond, Kimiyo , Matern, Dietrich , Rinaldo, Piero, Tortorelli, Silvia , Price, Theodore J. , Peck, Dawn S, White, Amy L , Studinski, April L, Jones, Kelly L , Oglesbee, Devin , Price, Theodore J , Spencer, Linda J. , Murray, Brianna K.

International Journal of Neonatal Screening | February 7, 2020 | Volume: 6 | Issue: 1 | Pages: 10

10.3390/ijns6010010 Get It

Enzyme-based newborn screening for Mucopolysaccharidosis type I (MPS I) has a high false-positive rate due to the prevalence of pseudodeficiency alleles, often resulting in unnecessary and costly follow up. The glycosaminoglycans (GAGs), dermatan sulfate (DS) and heparan sulfate (HS) are both substrates for α-l-iduronidase (IDUA). These GAGs are elevated in patients with MPS I and have been shown to be promising biomarkers for both primary and second-tier testing. Since February 2016, we have measured DS and HS in 1213 specimens submitted on infants at risk for MPS I based on newborn screening. Molecular correlation was available for 157 of the tested cases. Samples from infants with MPS I confirmed by IDUA molecular analysis all had significantly elevated levels of DS and HS compared to those with confirmed pseudodeficiency and/or heterozygosity. Analysis of our testing population and correlation with molecular results identified few discrepant outcomes and uncovered no evidence of false-negative cases. We have demonstrated that blood spot GAGs analysis accurately discriminates between patients with confirmed MPS I and false-positive cases due to pseudodeficiency or heterozygosity and increases the specificity of newborn screening for MPS I.
Multiplex Droplet Digital PCR Method Applicable to Newborn Screening, Carrier Status, and Assessment of Spinal Muscular Atrophy
Vidal‐Folch, Noemi, Gavrilov, Dimitar , Raymond, Kimiyo , Rinaldo, Piero, Tortorelli, Silvia , Matern, Dietrich , Oglesbee, Devin , Oglesbee, Devin

Clinical Chemistry | October 23, 2018 | Volume: 64 | Issue: 12 | Pages: 1753-1761

10.1373/clinchem.2018.293712 Get It

Abstract BACKGROUND Spinal muscular atrophy (SMA) is a progressive neuromuscular disorder with neuronal degeneration leading to muscular atrophy and respiratory failure. SMA is frequently caused by homozygous deletions that include exon 7 of the survival motor neuron gene SMN1, and its clinical course is influenced by the copy number of a nearby 5q SMN1 paralog, SMN2. Multiple ligation probe amplification (MLPA) and real-time quantitative PCR (qPCR) can detect SMN1 deletions. Yet, qPCR needs normalization or standard curves, and MLPA demands DNA concentrations above those obtainable from dried blood spots (DBSs). We developed a multiplex, droplet digital PCR (ddPCR) method for the simultaneous detection of SMN1 deletions and SMN2 copy number variation in DBS and other tissues. An SMN1 Sanger sequencing process for DBS was also developed. METHODS SMN1, SMN2, and RPP30 concentrations were simultaneously measured with a Bio-Rad AutoDG and QX200 ddPCR system. A total of 1530 DBSs and 12 SMA patients were tested. RESULTS Population studies confirmed 1 to 5 SMN1 exon 7 copies detected in unaffected specimens, whereas patients with SMA revealed 0 SMN1 copies. Intraassay and interassay imprecisions were &lt;7.1% CV for individuals with ≥1 SMN1 copies. Testing 12 SMA-positive samples resulted in 100% sensitivity and specificity. CONCLUSIONS This ddPCR method is sensitive, specific, and applicable to newborn screening and carrier status determination for SMA. It can also be incorporated with a parallel ddPCR T-cell excision circles assay for severe combined immunodeficiencies.
Allelic spectrum of formiminotransferase‐cyclodeaminase gene variants in individuals with formiminoglutamic aciduria
Majumdar, Ramanath, Yori, Andrew, Rush, Peggy W., Raymond, Kimiyo , Gavrilov, Dimitar , Tortorelli, Silvia , Matern, Dietrich , Rinaldo, Piero, Feldman, Gerald L. , Oglesbee, Devin , Oglesbee, Devin

Molecular Genetics & Genomic Medicine | September 12, 2017 | Volume: 5 | Issue: 6 | Pages: 795-799

10.1002/mgg3.333 Get It

AbstractBackgroundElevated plasma and urine formiminoglutamic acid (FIGLU) levels are commonly indicative of formiminoglutamic aciduria (OMIM #229100), a poorly understood autosomal recessive disorder of histidine and folate metabolism, resulting from formiminotransferase‐cyclodeaminase (FTCD) deficiency, a bifunctional enzyme encoded by FTCD.MethodsIn order to further understanding about the molecular alterations that contribute to FIGLU‐uria, we sequenced FTCD in 20 individuals with putative FTCD deficiency and varying laboratory findings, including increased FIGLU excretion.ResultsIndividuals tested had biallelic loss‐of‐function variants in protein‐coding regions of FTCD. The FTCD allelic spectrum comprised of 12 distinct variants including 5 missense alterations that replace conserved amino acid residues (c.223A>C, c.266A>G, c.319T>C, c.430G>A, c.514G>T), an in‐frame deletion (c.1373_1375delTGG), with the remaining alterations predicted to affect mRNA processing/stability. These included two frameshift variants (c.990dup, c.1366dup) and four nonsense variants (c.337C>T, c.451A>T, c.763C>T, c.1607T>A).ConclusionWe observed additional FTCD alleles leading to urinary FIGLU elevations, and thus, providing molecular evidence of FTCD deficiency in cases identified by newborn screening or clinical biochemical genetic laboratory testing.
Newborn Screening for X-Linked Adrenoleukodystrophy
Moser, Ann B. , Jones, Richard O., Hubbard, Walter C., Tortorelli, Silvia , Orsini, Joseph J. , Caggana, Michele, Vogel, Beth , Raymond, Gerald V.

International Journal of Neonatal Screening | December 6, 2016 | Volume: 2 | Issue: 4 | Pages: 15

10.3390/ijns2040015 Get It

Early diagnosis of males with X-linked adrenoleukodystrophy (X-ALD) is essential for preventing loss of life due to adrenal insufficiency and for timely therapy of the childhood cerebral form of X-ALD with hematopoietic cell transplantation. This article describes X-ALD, the current therapies, the history of the development of the newborn screening test, the approval by the Secretary of Health and Human Services for the addition of X-ALD newborn screening to the recommended uniform panel of disorders screened as newborns (RUSP) and the successful implementation of X-ALD newborn screening in the state of New York beginning on 30 December 2013. Follow-up guidelines that have been established in New York are outlined. Based on the success of newborn screening in New York, and early results in Connecticut, where X-ALD newborn screening started in December 2015, and in California, where X-ALD newborn screening began in September 2016, we are confident and hopeful that X-ALD newborn screening will expand to include all US states and to countries that have established neonatal screening programs. The Minster of Health in the Netherlands has approved the addition of X-ALD to the newborn screening program with a start date expected in 2017. The states, such as Massachusetts, Illinois, Minnesota, New Jersey, Florida and Washington, that have legislative approval will commence screening as soon as budgetary resources, testing and follow-up procedures are in place.
Simultaneous Testing for 6 Lysosomal Storage Disorders and X-Adrenoleukodystrophy in Dried Blood Spots by Tandem Mass Spectrometry
Tortorelli, Silvia , Turgeon, Coleman , Gavrilov, Dimitar K. , Oglesbee, Devin , Raymond, Kimiyo , Rinaldo, Piero, Matern, Dietrich , Turgeon, Coleman T, Raymond, Kimiyo M, Oglesbee, Devin

Clinical Chemistry | July 20, 2016 | Volume: 62 | Issue: 9 | Pages: 1248-1254

10.1373/clinchem.2016.256255 Get It

Abstract BACKGROUND Newborn screening for lysosomal storage disorders (LSD) has revealed that late-onset variants of these conditions are unexpectedly frequent and therefore may evade diagnosis. We developed an efficient and cost-effective multiplex assay to diagnose six LSDs and several peroxisomal disorders in patients presenting with diverse phenotypes at any age. METHODS Three 3-mm dried blood spot (DBS) punches were placed into individual microtiter plates. One disc was treated with a cocktail containing acid sphingomyelinase-specific substrate and internal standard (IS). To the second DBS we added a cocktail containing substrate and IS for β-glucosidase, acid α-glucosidase, α-galactosidase A, galactocerebrosidase, and α-L-iduronidase. The third DBS was extracted with methanol containing d4-C26 lysophosphatidylcholine as IS and stored until the enzyme plates were combined and purified by liquid–liquid and solid-phase extraction. The extracts were evaporated, reconstituted with the extract from the lysophosphatidylcholine plate, and analyzed by flow injection tandem mass spectrometry. RESULTS Reference intervals were determined by analysis of 550 samples from healthy controls. DBS from confirmed patients with 1 of the 6 LSDs (n = 33), X-adrenoleukodystrophy (n = 9), or a peroxisomal biogenesis disorder (n = 5), as well as carriers for Fabry disease (n = 17) and X-adrenoleukodystrophy (n = 5), were analyzed for assay validation. Prospective clinical testing of 578 samples revealed 25 patients affected with 1 of the detectable conditions. CONCLUSIONS Our flow injection tandem mass spectrometry approach is amenable to high-throughput population screening for Hurler disease, Gaucher disease, Niemann–Pick A/B disease, Pompe disease, Krabbe disease, Fabry disease, X-adrenoleukodystrophy, and peroxisomal biogenesis disorder in DBS.