Back to Authors

Chang, Hyuk‐Jae

https://orcid.org/0000-0002-6139-7545

Mayo Clinic

Yonsei University

Citations 6

Impact of statins based on high-risk plaque features on coronary plaque progression in mild stenosis lesions: results from the PARADIGM study
Sung, Ji Min , Lee, Byoung Kwon , Lin, Fay Y. , Hadamitzky, Martin , Kim, Yong‐Jin , Andreini, Daniele , Pontone, Gianluca , Chun, Eun Ju , Cademartiri, Filippo , Maffei, Erica , Marques, Hugo , Leipsic, Jonathon , Choi, Jung Hyun , Virmani, Renu , Samady, Habib , Chinnaiyan, Kavitha M. , Stone, Peter H. , Berman, Daniel S. , Shaw, Leslee J. , Min, James K. , Chang, Hyuk‐Jae , Cademartiri, Filippo , Virmani, Renu , Chang, Hyuk-Jae , Park, Hyung‐Bok , Arsanjani, Reza , Heo, Ran , Conte, Edoardo , Budoff, Matthew J. , Gottlieb, Ilan , Gonçalves, Pedro de Araújo , Lee, Sang‐Eun , Shin, Sanghoon , Narula, Jagat , Bax, Jeroen J.

European Heart Journal - Cardiovascular Imaging | May 26, 2023 | Volume: 24 | Issue: 11 | Pages: 1536-1543

10.1093/ehjci/jead110 Get It

Abstract Aims To investigate the impact of statins on plaque progression according to high-risk coronary atherosclerotic plaque (HRP) features and to identify predictive factors for rapid plaque progression in mild coronary artery disease (CAD) using serial coronary computed tomography angiography (CCTA). Methods and results We analyzed mild stenosis (25–49%) CAD, totaling 1432 lesions from 613 patients (mean age, 62.2 years, 63.9% male) and who underwent serial CCTA at a ≥2 year inter-scan interval using the Progression of AtheRosclerotic PlAque DetermIned by Computed TomoGraphic Angiography Imaging (NCT02803411) registry. The median inter-scan period was 3.5 ± 1.4 years; plaques were quantitatively assessed for annualized percent atheroma volume (PAV) and compositional plaque volume changes according to HRP features, and the rapid plaque progression was defined by the ≥90th percentile annual PAV. In mild stenotic lesions with ≥2 HRPs, statin therapy showed a 37% reduction in annual PAV (0.97 ± 2.02 vs. 1.55 ± 2.22, P = 0.038) with decreased necrotic core volume and increased dense calcium volume compared to non-statin recipient mild lesions. The key factors for rapid plaque progression were ≥2 HRPs [hazard ratio (HR), 1.89; 95% confidence interval (CI), 1.02–3.49; P = 0.042], current smoking (HR, 1.69; 95% CI 1.09–2.57; P = 0.017), and diabetes (HR, 1.55; 95% CI, 1.07–2.22; P = 0.020). Conclusion In mild CAD, statin treatment reduced plaque progression, particularly in lesions with a higher number of HRP features, which was also a strong predictor of rapid plaque progression. Therefore, aggressive statin therapy might be needed even in mild CAD with higher HRPs. Clinical trial registration ClinicalTrials.gov NCT02803411
Fully automated quantification of cardiac chamber and function assessment in 2-D Echocardiography: clinical feasibility of deep learning-based algorithms
Kim, Sekeun , Jeon, Jaeik, Park, Hyung‐Bok , Jeon, Jaeik , Arsanjani, Reza , Heo, Ran , Lee, Sang‐Eun , Moon, Inki , Yoo, Sun Kook , Chang, Hyuk‐Jae

No container title available | September 30, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-945163/v1 Get It

Abstract Objectives: We aimed to compare the segmentation performance of the current prominent deep learning (DL) algorithms with ground-truth segmentations and to validate the reproducibility of the manually created 2D echocardiographic four cardiac chamber ground-truth annotation.Background: Recently emerged DL based fully-automated chamber segmentation and function assessment methods have shown great potential for future application in aiding image acquisition, quantification, and suggestion for diagnosis. However, the performance of current DL algorithms have not previously been compared with each other. In addition, the reproducibility of ground-truth annotations which are the basis of these algorithms have not yet been fully validated.Methods: We retrospectively enrolled 500 consecutive patients who underwent transthoracic echocardiogram (TTE) from December 2019 to December 2020. Simple U-net, Res-U-net, and Dense-U-net algorithms were compared for the segmentation performances and clinical indices such as left atrial volume (LAV), left ventricular end diastolic volume (LVEDV), LV end systolic volume (LVESV), LV mass, and ejection fraction (EF) were evaluated. The inter- and intra- observer variability analysis was performed by two expert sonographers for a randomly selected echocardiographic view in 100 patients (apical 2-chamber, apical 4-chamber, and parasternal short axis views).Results: The overall performance of all DL methods was excellent (average Dice similarity coefficient (DSC) 0.91 to 0.95 and average Intersection over union (IOU) 0.83 to 0.90), with the exception of LV wall area on PSAX view (average DSC of 0.83, IOU 0.72). In addition, there were no significant difference in clinical indices between ground truth and automated DL measurements. For inter- and intra observer variability analysis, the overall intra observer reproducibility was excellent: LAV (ICC = 0.995), LVEDV (ICC = 0.996), LVESV (ICC = 0.997), LV mass (ICC = 0.991) and EF (ICC = 0.984). The inter-observer reproducibility was slightly lower as compared to intraobserver agreement: LAV (ICC = 0.976), LVEDV (ICC = 0.982), LVESV (ICC =0.970), LV mass (ICC = 0.971), and EF (ICC = 0.899).Conclusions: The three current prominent DL-based fully automated methods are able to reliably perform four-chamber segmentation and quantification of clinical indices. Furthermore, we were able to validate the four cardiac chamber ground-truth annotation and demonstrate an overall excellent reproducibility, but still with some degree of inter-observer variability.
Assessment of Image Quality for Selective Intracoronary Contrast-Injected CT Angiography in a Hybrid Angio-CT System: A Feasibility Study in Swine
Ha, Seongmin , Jung, Sunghee , Park, Hyung‐Bok , Shin, Sanghoon , Arsanjani, Reza , Hong, Youngtaek , Lee, Byoung Kwon , Jang, Yeonggul , Jeon, Byunghwan , Park, Se‐Il , Shim, Hackjoon , Chang, Hyuk‐Jae , Jung, Sung‐Hee , Jung, Sunghee , Arsanjani, Reza , Chang, Hyuk-Jae , Shim, Hackjoon , Park, Hyung Bok

Yonsei Medical Journal | February 24, 2021 | Volume: 62 | Issue: 3 | Pages: 200

10.3349/ymj.2021.62.3.200 Get It

Multicenter Study on the Diagnostic Performance of Native-T1 Cardiac Magnetic Resonance of Chronic Myocardial Infarctions at 3T
Wang, Guan , Yang, Qi , Sadras, Vignesh , Patel, Suraj , Yang, Hsin‐Jung , Sharif, Behzad , Kali, Avinash , Cokic, Ivan, Xie, Guoxi , Tighiouart, Mourad , Li, Debiao , Berman, Daniel S. , Chang, Hyuk‐Jae , Collins, Jeremy, Chang, Hyuk-Jae , Li, Debiao , Lee, Sang‐Eun , Collins, Jeremy D. , Dharmakumar, Rohan

Circulation: Cardiovascular Imaging | June 8, 2020 | Volume: 13 | Issue: 6 | Pages: No page available

10.1161/circimaging.119.009894 Get It

Background: Preclinical studies and pilot patient studies have shown that chronic infarctions can be detected and characterized from cardiac magnetic resonance without gadolinium-based contrast agents using native-T1 maps at 3T. We aimed to investigate the diagnostic capacity of this approach for characterizing chronic myocardial infarctions (MIs) in a multi-center setting. Methods: Patients with a prior MI (n=105) were recruited at 3 different medical centers and were imaged with native-T1 mapping and late gadolinium enhancement (LGE) at 3T. Infarct location, size, and transmurality were determined from native-T1 maps and LGE. Sensitivity, specificity, receiver-operating characteristic metrics, and inter- and intraobserver variabilities were assessed relative to LGE. Results: Across all subjects, T1 of MI territory was 1621±110 ms, and remote territory was 1225±75 ms. Sensitivity, specificity, and area under curve for detecting MI location based on native-T1 mapping relative to LGE were 88%, 92%, and 0.93, respectively. Native-T1 maps were not different for measuring infarct size (native-T1 maps: 12.1±7.5%; LGE: 11.8±7.2%, P =0.82) and were in agreement with LGE ( R 2 =0.92, bias, 0.09±2.6%). Corresponding inter- and intraobserver assessments were also highly correlated (interobserver: R 2 =0.90, bias, 0.18±2.4%; and intraobserver: R 2 =0.91, bias, 0.28±2.1%). Native T1 maps were not different for measuring MI transmurality (native-T1 maps: 49.1±15.8%; LGE: 47.2±19.0%, P =0.56) and showed agreement ( R 2 =0.71; bias, 1.32±10.2%). Corresponding inter- and intraobserver assessments were also in agreement (interobserver: R 2 =0.81, bias, 0.1±9.4%; and intraobserver: R 2 =0.91, bias, 0.28±2.1%, respectively). While the overall accuracy for detecting MI with native-T1 maps at 3T was high, logistic regression analysis showed that MI location was a prominent confounder. Conclusions: Native-T1 mapping can be used to image chronic MI with high degree of accuracy, and as such, it is a viable alternative for scar imaging in patients with chronic MI who are contraindicated for LGE. Technical advancements may be needed to overcome the imaging confounders that currently limit native-T1 mapping from reaching equivalent detection levels as LGE.
Diagnostic Accuracy of a Novel On-site Virtual Fractional Flow Reserve Parallel Computing System
Park, Hyung‐Bok , Jang, Yeonggul , Arsanjani, Reza , Nguyễn, Minh Tuấn , Lee, Sang‐Eun , Jeon, Byunghwan , Jung, Sung‐Hee , Hong, Youngtaek , Ha, Seongmin , Kim, Sekeun , Lee, Sang-Wook , Chang, Hyuk‐Jae , Jung, Sunghee , Arsanjani, Reza , Chang, Hyuk-Jae , Nguyen, Minh Tuan , Park, Hyung Bok

Yonsei Medical Journal | January 30, 2020 | Volume: 61 | Issue: 2 | Pages: 137

10.3349/ymj.2020.61.2.137 Get It