Back to Authors

Wang, Dee Dee

https://orcid.org/0000-0002-5784-9924

Mayo Clinic

Henry Ford Hospital

Citations 13

Complete percutaneous apical access and closure: Short and intermediate term outcomes
Eng, Marvin H. , Kherallah, Riyad , Guerrero, Mayra , Frisoli, Tiberio , Villablanca, Pedro , Wang, Dee Dee , Wyman, Janet , Wang, Dee Dee , Guerrero, Mayra E , Greenbaum, Adam B. , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | January 20, 2020 | Volume: 96 | Issue: 2 | Pages: 481-487

10.1002/ccd.28731 Get It

AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
Mohananey, Divyanshu , Villablanca, Pedro , Ando, Tomo , Wang, Dee Dee , Wiley, José , Eng, Marvin H. , Shah, Binita , Saucedo, Jorge , Bhatt, Deepak L. , Ando, Tomo , Wang, Dee Dee , Eng, Marvin , Ramakrishna, Harish , Bhatt, Deepak L , Shah, Binita , Gupta, Tanush , Ranka, Sagar , Bhatia, Nirmanmoh , Adegbala, Oluwole Muyiwa , Kalra, Ankur , O’Neill, William W.

Catheterization and Cardiovascular Interventions | April 26, 2019 | Volume: 94 | Issue: 2 | Pages: 249-255

10.1002/ccd.28310 Get It

AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement
Praz, Fabien , Khalique, Omar , Lee, Raymond , Wu, Isaac Y. , Russell, Hyde M., Wang, Dee Dee , Veeragandham, Ramesh, Islam, Ashequl , Deaton, David W., Eudailey, Kyle W. , Akkoc, Deniz, Kantor, Alex , Wang, Catherine , Tang, Diane, Park, Joongheum S, Leung, Diana, Nazif, Tamim , Vahl, Torsten , Kodali, Susheel , Leon, Martin B. , Takayama, Hiroo , Bapat, Vinayak , Borger, Michael A. , Wang, Dee Dee , Praz, Fabien , Guerrero, Mayra , Kaneko, Tsuyoshi , Tang, Diane C H, Hahn, Rebecca T , George, Isaac , Takayama, Hiroo

European Heart Journal - Cardiovascular Imaging | March 6, 2019 | Volume: 20 | Issue: 12 | Pages: 1395-1406

10.1093/ehjci/jez050 Get It

Abstract Aims To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). Methods and results In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. Conclusion In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.