Citations

Clear

1577 citation(s) found for "Wu, Samuel".

Abstract 371: Assessment of Catheter Position Above or Below the Aortic Valve by Evaluation of Characteristics of the Local Electro Gram: an Acute Canine Study
Pa, Deepak, Witt, Chance M. , Sugrue, Alan , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dejae, Drakulic, Budimir , Foxall, Thomas, LADEWIG, DEJAE J., Asirvatham, Samuel J.

Mayo Clinic

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.371 Get It

Background: Ablation in the sinuses of Valsalva (SoV) within the aorta is fraught with risk, owing to the proximity of the coronary arteries. Assessment of catheter tip position is not very easy at this location owing to complex local anatomy and poor images from available modalities. Objectives: We propose the use of novel local unipolar electrogram characteristics using a new signal recording system to guide the assessment of catheter tip position in this region. Methods: We recorded unipolar signals from above the SoV, within the coronaries and below the SoV using the PURE-EP™ (BioSig Technologies, MN) signal processing system in 4 anesthetized canines in the setting of an acute study. We used fluoroscopy, intracardiac echocardiography and angiography for confirmation of the position of the catheter tip. We recorded changes in the signals when transitioning between (1) the coronary arteries and the SoV and (2) the SoV and below the SoV. Results: The unipolar signal showed a negative current of injury (COI) when the catheter tip was present in the SoV, whereas within the coronary artery or below the SoV, the COI was positive. We propose that the difference in the distribution of ventricular muscle below and above the SoV is responsible for this phenomenon. These changes in the COI were noted immediately when transitioning from one location to another and were present reproducibly in all the dogs. ( Figure 1 ) Conclusions: Analysis of the changes on the local electrogram can provide information about the location of the catheter tip which could prove critical in saving lives.
Abstract 344: Optimal Serum Potassium, Calcium and Magnesium in the Coronary Care Unit
Krittanawong, Chayakrit , Park, Jae Y, Sharma, Sunita , Gaba, Prakriti , Rosenbaum, Andrew , Hu, Tiffany , Bell, Malcolm R. , Brady, Peter A. , Naksuk, Niyada , Krittanawong, Chayakrit , Thongprayoon, Charat , Herasevich, Vitaly , Kapa, Suraj , Asirvatham, Samuel J.

Mayo Clinic

Circulation: Cardiovascular Quality and Outcomes | March 20, 2022 | Volume: 8 | Issue: suppl_2 | Pages: No page available

10.1161/circoutcomes.8.suppl_2.344 Get It

Background: It is known that hypokalemia, hypocalcemia and hypomagnesemia cause a prolonged QTc interval and are associated with an increased risk of ventricular arrhythmias. However, there are limited data on optimal serum electrolytes for patients admitted to the coronary care unit (CCU). Objective: Here, we aimed to evaluate the relationship between serum potassium, ionized calcium and magnesium levels and in-hospital mortality in the CCU setting. Methods: This retrospective cohort study included 8,498 consecutive patients admitted to the CCU at an academic tertiary medical center from 2004 through 2013. The mean of serum electrolytes was categorized as <3.5, 3.5-<4.0, 4.0-<4.5 (reference), 4.5-<5.0, and ≥5.0 mEq/L for potassium; <4.4, 4.4-<4.6, 4.6-<4.8, 4.8-<5.0 (reference), and ≥5.0 mg/dL for ionized calcium; and <1.8, 1.8-<2.0, 2.0-<2.2 (reference), 2.2-<2.4, and ≥2.4 mg/dL for magnesium. Multivariate logistic regression analysis was used to determine the association between the mean of serum electrolytes and in-hospital mortality. Results: Of the 8,498 patients, 599 (7%) died during hospitalization. Relationship between mean serum potassium (U-shaped), ionized calcium (inverted J-shape) and magnesium (J-shaped) and in-hospital mortality was present in Figure. Serum potassium levels <3.5, 4.5-<5.0 and ≥5.0 mEq/L were independently associated with an increased risk of in-hospital mortality (adjusted OR 1.7 95% CI 1.1-2.5, OR 1.7 95% CI 1.3-2.2, and OR 3.4 95% CI 2.4-4.8, respectively), compared to the reference group. As for serum ionized calcium, the levels of <4.4, 4.4-<4.6, and 4.6-<4.8 mg/dL independently increased risk of mortality (adjusted OR 3.0 95% CI 2.3-4.0, OR 2.0 95% CI 1.5-2.6, and OR 1.4 95% CI, 1.1-1.8, respectively). As for serum magnesium, an only level above 2.4 mg/dL was associated with an increased mortality risk (OR 1.6 95% CI, 1.1-2.2). Conclusions: In the CCU setting, serum potassium 3.5-<4.5 mEq/L, ionized calcium ≥5.0 mg/dL and magnesium <2.4 mg/dL are associated with the lowest in-hospital mortality. These findings do not support supratherapeutic repletion of potassium and magnesium.
Abstract 11688: Left Atrial Appendage Occlusion in Patients With Atrial Fibrillation and Cancer
Shabtaie, Samuel A. , Tan, Nicholas Y. , Herrmann, Joerg , Ward, Robert C.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.11688 Get It

Introduction: Prevention of stroke in patients with atrial fibrillation and cancer is challenging as patients are at increased bleeding and thrombotic risk. Left atrial appendage occlusion (LAAO) has evolved as a promising strategy for stroke prevention with protentional to reduce bleeding risk, though no data exists on its efficacy in patients with cancer. Hypothesis: LAAO is a safe and effective strategy for reducing stroke and bleeding risk in cancer patients with atrial fibrillation. Methods: We retrospectively reviewed all patients with nonvalvular atrial fibrillation who underwent LAAO at all Mayo Clinic sites from 2017-2020 and identified those who had undergone prior or current treatment for cancer. Baseline demographics, malignancy history, atrial fibrillation parameters, procedural success/complications, stroke and bleeding incidence and major adverse cardiac events were ascertained. Results: 55 patients were included in the study; 44 (80.0%) were male and mean age was 79.0 ± 6.1 years. Most common primary malignancies included prostate cancer (29.1%), oropharyngeal cancer (12.7%), and melanoma (10.9%) with 15 (27.3%) having metastatic disease and 14 (25.5%) patients having active malignancy at device implant. Mean CHA2DS2-Vasc score was 4.9 ± 1.3, with 47 (85.5%) patients having a prior bleeding event. Acute procedural success was achieved in all patients with 30-day complications including 4 (7.3%) with vascular access site bleeding, 1 (1.8%) with pericarditis and 1 (1.8%) with a seizure. At a follow up of 1.8 ± 1.1 years, ischemic stroke occurred in 2 (3.6%) patients with bleeding complications in 5 (9.1%) patients. Device related complications occurred in 6 (10.9%) patients with 4 (7.3%) with device thrombosis and 2 (3.6%) with a peri-device leak. Death occurred in 14 (25.5%) patients most commonly due to malignancy progression (9.1%) and infection (7.3%). Conclusions: In our study cohort, LAAO in patients with cancer was achieved with excellent procedural success and offered reasonable reduction in stroke and bleeding risk. Mortality was high likely due to the age of the patients studied, underlying malignancy and comorbidities. Further studies are needed to investigate the prevalence of device thrombosis in cancer patients.
Abstract 10726: Cardiac Resynchronization Therapy Response in Cardiac Sarcoidosis
Shabtaie, Samuel A. , Lee, Justin Z. , Cha, Yong‐Mei , Bois, John P. , Rosenbaum, Andrew , Siontis, Konstantinos C. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V. , Kapa, Suraj , AbouEzzeddine, Omar F.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.10726 Get It

Introduction: Cardiac Sarcoidosis (CS) is a non-ischemic cardiomyopathy (NICM) characterized by infiltration of non-caseating granulomas involving in the heart with highly variable clinical manifestations. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its effectiveness in patients with CS. Hypothesis: We sought to determine if CRT improved cardiac remodeling and reduced hospitalizations in patients with CS. Methods: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at a Mayo Clinic site from 2000-2021. Baseline characteristics, echocardiographic parameters, heart failure hospitalization, and major adverse cardiac events (MACE) were assessed. Results: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. At baseline, 38 (69.1%) patients had isolated CS, while 17 (30.9%) had evidence of CS with extra-cardiac sarcoidosis. The overwhelming majority underwent CRT-D implantation (n=52, 94.5%) with 67.3% of implanted devices upgrades from prior pacemaker or implantable cardioverter defibrillator. At 6 months post-implantation there was no significant different in ejection fraction (34.8 ± 10.9 % vs. 37.7 ± 14.2 %, p = 0.237), left ventricular end systolic diameter (49.1 ± 9.9 mm vs. 45.7 ± 9.9 mm, p = 0.077) or left ventricular end-diastolic diameter (58.5 ± 10.2 mm vs. 57.5 ± 8.1 mm, p = 0.574). Within the first 6 months post-implantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow up of 4.1 ± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent LVAD implantation and 7 (12.7%) patients died. Conclusions: Our findings suggest a poor response to CRT in patients with CS with no significant evidence of reverse remodeling within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
Abstract 10068: Guideline Directed Medical Therapy in Newly Diagnosed Heart Failure with Reduced Ejection Fraction in the Community: Impact of Heart Failure Clinic
Killian, Jill M. , Roger, Véronique L. , Schulte, Philip, Redfield, Margaret M. , Dunlay, Shannon M. , Savitz, Samuel T. , Blecker, Saul

Mayo Clinic

Circulation | March 19, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.10068 Get It

Introduction: Guideline-directed medical therapy (GDMT) dramatically improves outcomes in heart failure with reduced ejection fraction (HFrEF). Our goal was to examine GDMT use in community patients with newly diagnosed HFrEF. Methods: We performed a population-based, retrospective cohort study of all Olmsted County, Minnesota residents with newly diagnosed HFrEF (EF≤40%) 2007-2017. We excluded patients with contraindications to medication initiation (allergy, intolerance, heart rate<50 for beta blockers, SBP <80mm Hg for beta blockers, ACEi/ARB/ARNI; high creatinine (>3 mg/dL ACEi/ARB/ARNI, >2.5 men or >2.0 mg/dL women for mineralocorticoid receptor antagonists, MRAs) or hyperkalemia (potassium >5 meQ/L for ACEi/ARB/ARNI, MRA). We examined use and peak dose achieved for beta blockers, HF beta blockers (metoprolol succinate, carvedilol, bisoprolol), ACEi/ARB/ARNI, and MRA in the first year after HFrEF diagnosis. We used logistic regression to evaluate predictors of GDMT use. Results: From 2007-2017, 1160 patients were diagnosed with HFrEF (mean age 69.7 years, 65.6% men). Most eligible patients received beta blockers (92.1%) and ACEi/ARB/ARNI (86.5%) in the first year after HFrEF. However, only 63.6% of patients were treated with a HF beta blocker, and most did not receive MRAs (82.6%). The percentage of treated patients reaching medication target doses was 20.5% for HF beta blockers, 25.3% for ACEi/ARB/ARNI, and 11.2% for MRA. Compared to patients not seen in an HF clinic, patients seen in an HF clinic (n=380, 32.8%) were at greater odds of receiving beta blockers (OR 3.85, 95% CI 1.79-8.33); HF beta blockers (OR 3.85, 95% CI 2.63-5.26); ACEi/ARB/ARNIs (OR 3.85, 95% CI 2.17-6.67); and MRAs (OR 3.03, 95% CI 2.08-4.35). Other independent predictors of GDMT use included younger age (beta blockers, ACEi/ARB/ARNI), male gender (MRAs), higher SBP (beta blockers, ACEi/ARB/ARNI), lower EF (HF beta blockers), higher BMI (MRAs), and diabetes (ACEi/ARB/ARNI, p<0.05 for each). Conclusions: In this population-based study, most patients with newly diagnosed HFrEF received beta blockers and ACEi/ARB/ARNIs, but goal doses were usually not achieved. GDMT use was much higher in patients referred to an HF clinic.
Abstract 19422: Origin of Ventricular Fibrillation in Bileaflet Mitral Valve Prolapse Syndrome
Syed, Faisal F. , Ackerman, Michael J. , Mulpuru, Siva K. , Sriram, Chenni S. , Cannon, Bryan C. , McLeod, Christopher J. , Kapa, Suraj , Asirvatham, Samuel J. , Noseworthy, Peter A.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.19422 Get It

Introduction: Although most patients with mitral valve prolapse (MVP) have a benign prognosis, there is a subgroup with bileaflet MVP syndrome (biMVPS) at increased risk of idiopathic ventricular fibrillation (VF). The phenotypic features of this syndrome include myxomatous bileaflet prolapse, complex ventricular ectopy (VE), T-wave inversion in inferolateral ECG leads, and female predominance. The mechanism of ventricular arrhythmia in these patients is unknown. Methods: We reviewed our center’s ablation experience of 14 consecutive patients with biMVPS patients between February 2007 and October 2013 (n=13 female, median [range] age at index ablation 33.8 [21.0 - 58.7] years, left ventricular ejection fraction [EF] 60 [45-67] %, all ≤ moderate mitral regurgitation [MR]). We compared findings from 6 with prior sudden cardiac arrest (SCA) and recurrent ICD shocks for drug refractory VF with 8 who had symptomatic drug-refractory complex VE but without prior SCA. Results: All patients with prior SCA had a predominant VE trigger for the VF. There was no difference between the two groups in EF, MR severity, VE burden, and number of different VE morphologies or foci ablated. Sites of successful VE ablation at index procedure were the LV papillary muscles (PM, n=6 anterior, 6 posterior), fascicular system (n=5 anterior, 4 posterior), mitral annulus (n=2), outflow tracts (3 RVOT, 1 LVOT), and coronary sinus (n=1). All patients had at least one LV papillary or fascicular VE focus. Purkinje origin VE was identified as the VF trigger in 6/6 SCA patients (3 from PM, 3 from LV fascicles) and only 4/8 (none from PM) non-SCA patients (p=0.04). Acute success was seen in 17/19 procedures with no complications. VF storm occurred within 24 hours of ablation in a single patient. At 310 (39 - 2099) days follow-up, 1 SCA patient received a single shock (p=0.031 compared to pre-ablation), and symptoms from VE were reduced in 12/14. Conclusions: BiMVPS is characterized by VE from the LV fascicles and papillary muscles that trigger VF. The VE is invariably multifocal and may also involve the outflow tracts and mitral annulus. Ablation of clinically dominant VE foci alleviates symptoms and reduces the number of VF-terminating ICD shocks.
Abstract 16562: Cardiac Device Implantation Post TAVR: Mortality and Rates of Pacemaker Dependency
Padmanabhan, Deepak , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong-Mei M, Asirvatham, Samuel, Friedman, Paul A. , Greason, Kevin L. , Gulati, Rajiv , Scott, Christopher G. , McLeod, Christopher J. , Cha, Yong-Mei M, Noseworthy, Peter A.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16562 Get It

Background: Transcatheter aortic valve replacement (TAVR) is often complicated by AV block requiring pacing, but whether patients recover AV conduction and whether the need for pacing affects outcomes is unknown. Methods: We retrospectively studied 534 patients who underwent TAVR at Mayo Clinic in Rochester, Minnesota between November 2008 and January 2015. Of these, 115 patients had implantable cardiac devices. Data was collected from subsequent device follow-ups to determine pacemaker dependency and percentage pacing. Results: 44 patients (8.2%) had devices implanted in the immediate post procedural period. The most common indications for implantation were high grade AV block (18 patients) and complete heart block (14 patients). 17/44 (38.6%) patients were pacemaker-dependent at implant and only 4 of these patients were no longer pacemaker-dependent during subsequent followup. The indication for pacing among these four patients was high grade atrio-ventricular block (2 patients), asystole (1 patient) and complete heart block (1). Among non-pacemaker-dependent patients, no significant change in the ventricular pacing percentages was noted over time. Survival was similar between patients who required device implantation post TAVR and those who did not after adjustment for age and gender (HR 0.73 [0.39-1.36], p=ns; figure) Conclusion: Patients requiring pacing after TAVR are often pacemaker-dependent at the time of implant. It is uncommon for patients who are dependent at the time of implant to regain AV conduction, but the need for cardiac pacing is not associated with increased mortality.
Abstract 16326: Safety and Efficacy of Novel Oral Anticoagulants in Subjects With Atrial Fibrillation in Relation to Renal Function: Meta-analysis of Randomized Clinical Trials
Carpio, Freddy Del, Gharacholou, S. Michael , Branson, Andrea M, Paletta, Dawn M, Brose, Pamela K, Asirvatham, Samuel J.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16326 Get It

Introduction: The efficacy and safety of novel oral anticoagulants (NOACs) has not been assessed in subjects with renal impairment. Methods: We performed a meta-analysis of RCTs comparing NOACs with warfarin in patients with atrial fibrillation (AF), in relation to renal function estimated by glomerular filtration rate (GFR): normal (GFR>80 ml/min/1.73m2), mild (50-80 mL/min/1.73m2), and moderate (<50 mL/min/1.73m2) impairment. MEDLINE, Embase, Web of Science and the Cochrane Library were searched to identify articles published up to the third week of January 2015. Data were supplemented with FDA data. Data on stroke or systemic embolism (S/SE) and major bleeding according to renal function were collected and extracted. We estimated the pooled relative risk (RR) of S/SE and major bleeding, for NOACs compared to warfarin. Results: We retrieved four randomized clinical trials (each randomizing dabigatran, rivaroxaban, apixaban, or endoxaban versus warfarin) enrolling a total of 58338 subjects, 29123 randomized to NOACs and 29123 randomized to warfarin; 21132 had normal renal function, 13126 had mild and 11027 had moderate renal impairment. In subjects with moderate renal impairment, compared to warfarin, NOACs reduced the risk of S/SE (RR 0.8; 95% CI 0.68-0.94) and major bleeding (RR 0.80; 95% CI 0.71-0.91). In subjects with mild renal impairment NOACs were associated with a reduced risk of S/SE (RR 0.75; 95% CI 0.66-0.85) and major bleeding (RR 0.87; 95% CI 0.79-0.95). In subjects with normal renal function no difference in the risk of S/SE was observed, while the risk of major bleeding was slightly less for subjects taking NOACs (RR 0.87; 95% CI 0.76-0.99). The test for interaction among groups of renal function was borderline significant for S/SE, but not for major bleeding. Conclusions: The use of NOACs was associated with a reduced risk of S/SE in subjects with mild or moderate renal impairment; while the risk of bleeding was reduced by NOACs compared to warfarin.
Abstract 16261: Risk of Stroke or Systemic Embolism After Transseptal Ablation in Patients With Implanted Cardiac Devices
Madhavan, Malini , Sangaralingham, Lindsey R. , Noseworthy, Peter A. , DeSimone, Christopher V. , McLeod, Christopher J. , Asirvatham, Samuel J. , Yao, Xiaoxi

Mayo Clinic

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16261 Get It

Introduction: Mobile thrombi are commonly observed on endovascular leads at the time of catheter ablation. Transseptal puncture poses a risk of paradoxical embolism. We sought to examine the risk of stroke or systemic embolism after transseptal ablation in patients with and without cardiac implantable electronic devices (CIEDs). Methods: Using a large, national administrative claims database we identified 31,720 patients who underwent a catheter ablation requiring transseptal puncture between 1/1/2004 and 9/30/2014. We created two propensity-matched cohorts, matching on age, gender, race, household income, region, Charlson index, CHADS-Vasc score, and year and indication for ablation (5,533 patients with CIEDs and 11,300 patients without devices). Incidence rates (events/100 patient-years) and propensity score-matched cox proportional hazards models (with 95% confidence intervals) were used to estimate risk of stroke, transient ischemic attack, or systemic embolism for patients with or without CIEDs. We also examined the impact of presence of a CIED and oral anticoagulation (OAC) use on risk of stroke or systemic embolism within the matched cohort. Average follow up was 2.1 years. Results: The event rate was 1.5 per 100 person years in patients without device, and 1.9 per 100 person years in patients with device. Among patients not on OAC, presence of a cardiac device was associated with an increased risk of stroke or systemic embolism (HR 1.71 [1.24-2.35], P<0.01) whereas there was no association among patients treated with OAC (0.98 [0.75_1.28], p=ns) (Figure). Conclusions: Cardiac devices are associated with an increased risk of stroke or systemic embolism after transseptal ablation, but this risk is attenuated with post ablation OAC use. Anticoagulation should be considered for all patients with CIEDs post transseptal ablation, regardless of the presence of another compelling indication for anticoagulation.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Mayo Clinic

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.