Citations 47

Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes

Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circep.126.014954 | PMID 42755696

BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Physiology-guided cardioneuroablation for vagally mediated syncope and functional bradyarrhythmias

No container title available | August 5, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.08.03.26359633

Abstract Background Vagally mediated syncope and functional bradyarrhythmias can cause recurrent symptoms, injury and a need for permanent pacing, yet standard therapies do not address the underlying autonomic reflex. Cardioneuroablation (CNA) targets this mechanism, but adoption has been limited by uncertainty about patient selection, procedural endpoints and durable outcomes. Methods We studied 95 consecutive patients with vagally mediated syncope (n=78) or functional bradyarrhythmia (n=17) who underwent CNA at a single center by a single lead operator under a uniform, prospectively maintained protocol. Extracardiac vagal stimulation (ECVS) was performed before and after ablation to confirm vagally mediated sinus or atrioventricular (AV) nodal responses and to verify their attenuation. Outcomes through 1 year included clinical recurrence, quality of life, pacing burden and pacemaker extraction. Results Before ablation, ECVS provoked sinus pauses in 95.8% of patients and AV block in 91.6%; after ablation, sinus pauses were abolished in every patient and residual AV block was present in 4.2%. One-year freedom from recurrent syncope and from bradyarrhythmia-related events was 93.8% and 94.1%. Syncope burden fell from a median of 2.7 episodes per year to none, and disease-specific quality of life improved substantially (P<0.001). Among patients with pre-existing devices, atrial pacing burden fell from a median of 22% to 0%. There were no strokes, deaths or myocardial infarctions. Conclusions In this single-center cohort, physiology-guided CNA was associated with durable symptom control, improved quality of life and reduced pacing across vagally mediated bradyarrhythmia syndromes. Multicenter controlled studies are needed to confirm these findings.
Bachmann's bundle pacing: toward physiologic atrial activation

Frontiers in Cardiovascular Medicine | July 29, 2026 | Volume: 13 | Issue: No issue available | Pages: No page available

10.3389/fcvm.2026.1895174 | PMID 42591967

Bachmann's bundle (BB) pacing is an emerging physiological atrial pacing strategy designed to preserve interatrial conduction and coordinated atrial activation. Conventional right atrial appendage pacing may produce non-physiological activation, contributing to atrial dyssynchrony, impaired left atrial function, and increased risk of atrial fibrillation. Because BB is the predominant pathway for right-to-left atrial conduction, targeted BB pacing can shorten the P-wave duration and improve atrial synchrony. Recent fluoroscopic, electrogram-guided, and P-wave morphology criteria have improved confirmation of BB capture. Available studies suggest that BB pacing is feasible and generally safe, with potential benefits in reducing the burden of atrial arrhythmias. However, the long-term clinical outcomes remain uncertain. Larger prospective studies are needed to standardize BB capture criteria, define optimal patient selection, and assess long-term outcomes.
An Unexpected Encounter: When a Novel Device Algorithm Meets a Novel Ablation System

Journal of Cardiovascular Electrophysiology | July 8, 2026 | Volume: 37 | Issue: 8 | Pages: 1883-1885

10.1111/jce.70449 | PMID 42418732

Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease

Journal of Cardiovascular Electrophysiology | May 26, 2026 | Volume: 37 | Issue: 7 | Pages: 1599-1604

10.1111/jce.70364 | PMID 42188975

ABSTRACT Background Patients with end‐stage renal disease (ESRD) undergoing dialysis have an increased risk of pacemaker‐related complications due to limited vascular access and increased susceptibility to infection. Leadless pacemakers (LPMs) may mitigate these risks compared with conventional transvenous pacemakers (TPMs), but long‐term comparative data in this population remain limited. Methods We conducted a retrospective cohort study using the TriNetX Research Network, including adults (≥ 18 years) with ESRD on dialysis who underwent LPM or TPM implantation between May 2016 and December 2020. Propensity score matching (1:1) was performed using demographics and comorbidities. Outcomes assessed over up to 5 years included all‐cause hospitalization, heart failure hospitalization, device re‐intervention, device‐related complications, infection‐related hospitalization, pacemaker‐induced cardiomyopathy, and all‐cause mortality. Results After matching, 901 patients were included in each group with well‐balanced baseline characteristics. LPM implantation was associated with a significantly lower risk of device re‐intervention compared with TPM (4.1% vs. 9.3%; hazard ratio [HR] 0.44; 95% confidence interval [CI] 0.28–0.69; p < 0.01). There were no significant differences between groups in all‐cause hospitalization (65.5% vs. 68.3%; p = 0.22), heart failure hospitalization (26.9% vs. 30.2%; p = 0.13), all‐cause mortality (37.5% vs. 35.3%; p = 0.34), device‐related complications (14.5% vs. 14.3%; p = 0.94), infection‐related hospitalization (1.6% vs. 2.1%; p = 0.35), or pacemaker‐induced cardiomyopathy (9.0% vs. 8.6%; p = 0.66). Conclusion In a large, propensity‐matched cohort of patients with ESRD on dialysis, LPMs were associated with fewer device re‐interventions and comparable long‐term clinical outcomes compared with TPMs.
Clinical Outcomes of Catheter Ablation for Atrial Fibrillation in Patients With Hypertrophic Cardiomyopathy

Journal of Cardiovascular Electrophysiology | May 15, 2026 | Volume: 37 | Issue: 7 | Pages: 1496-1503

10.1111/jce.70377 | PMID 42138486

ABSTRACT Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with increased morbidity, heart failure (HF) exacerbations, and adverse long‐term outcomes. Although catheter ablation is an established rhythm‐control strategy, data comparing its long‐term clinical outcomes with anti‐arrhythmic drug (AAD) therapy in patients with HCM remain limited. Objective To compare long‐term clinical outcomes of catheter ablation versus medical therapy with AADs in patients with HCM and AF. Methods We conducted a retrospective cohort study using the TriNetX Research Network, a global federated database of electronic health records. Adult patients with HCM and AF between January 2010 and December 2020 were identified and stratified according to treatment with catheter ablation or AAD therapy. Outcomes included all‐cause mortality, HF exacerbations, AAD‐related adverse events, all‐cause hospitalization, ischemic stroke, repeat ablation, need for cardioversion, need for long‐term AAD use, and atrioventricular nodal ablation. A 1:1 propensity score matching (PSM) analysis was performed to balance baseline characteristics. Kaplan–Meier survival analysis and Cox proportional hazards models were used to estimate hazard ratios (HRs). Results After PSM, 3144 patients were included (1572 in each cohort) with a mean follow‐up of approximately 3.4 years. Catheter ablation was associated with lower all‐cause mortality compared with AAD therapy (9.5% vs. 14.8%; HR: 0.60; 95% CI: 0.49–0.74; p < 0.001). Ablation was also associated with reduced risk of HF exacerbations (38.4% vs. 43.3%; HR: 0.79; 95% CI: 0.71–0.88; p < 0.001) and fewer AAD‐related adverse events (8.4% vs. 11.2%; HR: 0.71; 95% CI: 0.55–0.93; p = 0.011). Rates of all‐cause hospitalization (HR: 0.93; p = 0.11) and ischemic stroke (HR: 0.78; p = 0.10) were similar between groups. Conclusion In this large real‐world cohort of patients with HCM and AF, catheter ablation was associated with lower mortality, reduced HF hospitalizations, and decreased AAD therapy‐related adverse events, as compared with medical therapy. These findings suggest that catheter ablation may provide meaningful clinical benefits in selected patients with HCM and AF, although prospective studies are needed to confirm these observations.
Outcomes of Transvenous Lead Removal in Patients With Prior Mediastinal Radiation

Journal of Cardiovascular Electrophysiology | November 18, 2025 | Volume: 37 | Issue: 1 | Pages: 186-189

10.1111/jce.70192 | PMID 41250637

ABSTRACT Background Transvenous lead removal (TLR) in patients with a history of mediastinal radiation poses unique challenges due to potential radiation‐induced fibrosis, vascular changes, and anatomical distortion, which may increase procedural complexity and complication risk. However, contemporary data on clinical outcomes in this population remain limited. Methods We analyzed the National Readmissions Database (2016–2021) to identify adults (≥ 18 years) undergoing TLR. Patients were stratified by prior mediastinal radiation. Baseline characteristics were compared using standard statistical tests. Multivariable logistic regression was used to evaluate the association between prior mediastinal radiation and in‐hospital outcomes, 30‐day mortality, and 30‐day readmissions after adjustment for demographics and comorbidities. Results A total of 48,985 patients underwent TLR, of whom 735 (1.5%) had a history of mediastinal radiation. Compared with patients without radiation, those with prior radiation were older (70.1 vs. 66.2 years, p < 0.01), were more frequently females (38.2% vs. 31.6%, p < 0.01), and had higher rates of valvular heart disease, atrial fibrillation, and peripheral vascular disease. Adjusted analyses demonstrated no increased risk of in‐hospital mortality (2.3% vs. 3.4%; adjusted odds ratio [aOR] 0.65, 95% confidence interval [CI] 0.41–1.18, p = 0.29) or major complications, including cardiac arrest, pericardial complications, vascular injury, pulmonary complications, or embolic events. Similarly, (3.6% vs. 5.3%; aOR 0.76, 95% CI 0.48–1.43, p = 0.35) and 30‐day all‐cause readmissions (8.7% vs. 9.1%; aOR 0.81, 95% CI 0.64–1.28, p = 0.70) were not significantly different between groups. Subgroup analyses by indication for TLR (infection vs. mechanical complication) revealed no differences in outcomes. Conclusion Despite theoretical concerns, prior mediastinal radiation was not associated with excess procedural risk or worse short‐term outcomes after TLR. These findings may inform procedural planning and risk counseling in clinical practice.
Atrioventricular node ablation for refractory atrial fibrillation in patients with hypertrophic cardiomyopathy: a case–control study

Europace | September 6, 2025 | Volume: 27 | Issue: 9 | Pages: No page available

10.1093/europace/euaf208 | PMID 40913440

Sex, Race, and Socioeconomic Disparities in the Utilization of Transvenous Lead Removal for Patients Hospitalized With Cardiac Implantable Electronic Device Infections in the United States

Journal of Cardiovascular Electrophysiology | June 12, 2025 | Volume: 36 | Issue: 8 | Pages: 1938-1947

10.1111/jce.16758 | PMID 40501006

ABSTRACT Background Transvenous lead removal (TLR) is a Class I indication for patients with cardiac implantable electronic device (CIED) infections. However, disparities in the utilization of TLR have not been fully explored, particularly concerning demographic and socioeconomic factors. Objectives This study aims to examine whether disparities exist among patients hospitalized for CIED infections with respect to the utilization of TLR, focusing on sex, race, and income characteristics. Methods We utilized the 2019 National Inpatient Sample (NIS) to assess patients hospitalized with CIED infections and identify those who underwent TLR. Multiple logistic regression was used to examine risk factors for TLR utilization, including age, sex, race/ethnicity, and socioeconomic characteristics. Results A total of 56 709 patients were hospitalized for CIED infection in the United States in 2019, of which 9867 (17.4%) underwent TLR. On an adjusted analysis, females and Black patients were found to have lower odds of undergoing TLR compared to males and White patients (OR: 0.62; 95% CI: 0.59–0.78; p < 0.01; and OR: 0.47; 95% CI: 0.39–0.57; p < 0.01, respectively). Hispanic patients also had reduced odds of TLR (OR: 0.73; 95% CI: 0.58–0.93; p = 0.01). No significant associations were observed between income or insurance status and the likelihood of receiving TLR after adjustment. Conclusions This study identified significant disparities in the utilization of TLR among patients hospitalized for CIED infections. Female, Black, and Hispanic patients were significantly less likely to receive TLR.
Prognostic impact of cardiac resynchronization therapy in wild-type transthyretin amyloid cardiomyopathy

Amyloid | May 26, 2025 | Volume: 32 | Issue: 3 | Pages: 289-291

10.1080/13506129.2025.2504443 | PMID 40415407