Abstract Background Vagally mediated syncope and functional bradyarrhythmias can cause recurrent symptoms, injury and a need for permanent pacing, yet standard therapies do not address the underlying autonomic reflex. Cardioneuroablation (CNA) targets this mechanism, but adoption has been limited by uncertainty about patient selection, procedural endpoints and durable outcomes. Methods We studied 95 consecutive patients with vagally mediated syncope (n=78) or functional bradyarrhythmia (n=17) who underwent CNA at a single center by a single lead operator under a uniform, prospectively maintained protocol. Extracardiac vagal stimulation (ECVS) was performed before and after ablation to confirm vagally mediated sinus or atrioventricular (AV) nodal responses and to verify their attenuation. Outcomes through 1 year included clinical recurrence, quality of life, pacing burden and pacemaker extraction. Results Before ablation, ECVS provoked sinus pauses in 95.8% of patients and AV block in 91.6%; after ablation, sinus pauses were abolished in every patient and residual AV block was present in 4.2%. One-year freedom from recurrent syncope and from bradyarrhythmia-related events was 93.8% and 94.1%. Syncope burden fell from a median of 2.7 episodes per year to none, and disease-specific quality of life improved substantially (P<0.001). Among patients with pre-existing devices, atrial pacing burden fell from a median of 22% to 0%. There were no strokes, deaths or myocardial infarctions. Conclusions In this single-center cohort, physiology-guided CNA was associated with durable symptom control, improved quality of life and reduced pacing across vagally mediated bradyarrhythmia syndromes. Multicenter controlled studies are needed to confirm these findings.
Machine Learning With Genetic and Clinical Data to Predict Ischemic Outcomes After
PCI
Clinical and Translational Science | July 10, 2026 | Volume: 19 | Issue: 7 | Pages: No page available
ABSTRACT Ischemic events after contemporary percutaneous coronary intervention (PCI) are uncommon but carry high morbidity/mortality. Identifying patients at highest risk is critical to guide dual antiplatelet therapy (DAPT) intensity while minimizing bleeding. Current machine learning (ML) model‐developed risk scores do not incorporate pharmacogenetic data. To develop and externally validate ML models that integrate clinical, demographic, and CYP2C19 genetic information to predict 1‐year ischemic outcomes post‐PCI to refine clinical decision making. We analyzed 8317 patients from TAILOR‐PCI trial ( n = 4572) and the Precision PCI registry ( n = 3745). The outcome was a composite of cardiovascular death, myocardial infarction, stroke, and stent thrombosis at 1 year. Boruta feature selection identified 11 predictors. Multiple ML algorithms were trained in TAILOR‐PCI and validated in Precision PCI using cross‐validation and synthetic minority oversampling (SMOTE). Model performance was assessed by area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. The best external performance was achieved with a support vector machine (SVM, polynomial kernel) (AUC 0.667; sensitivity 0.871; specificity 0.282), while XGBoost provided a more balanced profile (AUC 0.619; sensitivity 0.442; specificity 0.688). Variable importance for the SVM polynomial model demonstrated that all 11 included Boruta feature selected predictors had relatively high importance (> 75). ML models trained on large clinical trial and real‐world registry datasets can help identify the small subset of patients at high ischemic risk after PCI. This distinction is of relevance because ischemic events are rare, and most patients may safely de‐escalate DAPT to reduce bleeding risk while maintaining ischemic protection through a multimodal approach to risk stratification. Trial Registration: TAILOR‐PCI URL: https://clinicaltrials.gov/ct2/show/NCT01742117
Clinical Outcomes of Catheter Ablation for Atrial Fibrillation in Patients With Hypertrophic Cardiomyopathy
Journal of Cardiovascular Electrophysiology | May 15, 2026 | Volume: 37 | Issue: 7 | Pages: 1496-1503
ABSTRACT Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with increased morbidity, heart failure (HF) exacerbations, and adverse long‐term outcomes. Although catheter ablation is an established rhythm‐control strategy, data comparing its long‐term clinical outcomes with anti‐arrhythmic drug (AAD) therapy in patients with HCM remain limited. Objective To compare long‐term clinical outcomes of catheter ablation versus medical therapy with AADs in patients with HCM and AF. Methods We conducted a retrospective cohort study using the TriNetX Research Network, a global federated database of electronic health records. Adult patients with HCM and AF between January 2010 and December 2020 were identified and stratified according to treatment with catheter ablation or AAD therapy. Outcomes included all‐cause mortality, HF exacerbations, AAD‐related adverse events, all‐cause hospitalization, ischemic stroke, repeat ablation, need for cardioversion, need for long‐term AAD use, and atrioventricular nodal ablation. A 1:1 propensity score matching (PSM) analysis was performed to balance baseline characteristics. Kaplan–Meier survival analysis and Cox proportional hazards models were used to estimate hazard ratios (HRs). Results After PSM, 3144 patients were included (1572 in each cohort) with a mean follow‐up of approximately 3.4 years. Catheter ablation was associated with lower all‐cause mortality compared with AAD therapy (9.5% vs. 14.8%; HR: 0.60; 95% CI: 0.49–0.74; p < 0.001). Ablation was also associated with reduced risk of HF exacerbations (38.4% vs. 43.3%; HR: 0.79; 95% CI: 0.71–0.88; p < 0.001) and fewer AAD‐related adverse events (8.4% vs. 11.2%; HR: 0.71; 95% CI: 0.55–0.93; p = 0.011). Rates of all‐cause hospitalization (HR: 0.93; p = 0.11) and ischemic stroke (HR: 0.78; p = 0.10) were similar between groups. Conclusion In this large real‐world cohort of patients with HCM and AF, catheter ablation was associated with lower mortality, reduced HF hospitalizations, and decreased AAD therapy‐related adverse events, as compared with medical therapy. These findings suggest that catheter ablation may provide meaningful clinical benefits in selected patients with HCM and AF, although prospective studies are needed to confirm these observations.
First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available
BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Abstract 4371463: Cuffless Blood Pressure Monitoring Using a Novel Wrist-Worn Photoplethysmography Device: Validation Against Intra-Arterial Blood Pressure
Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available
Background: Cuffless blood pressure (BP) monitoring devices with the ability to continuously and noninvasively collect data could transform the screening and management of hypertension. While some wearable devices can estimate BP, their accuracy and reliability remain limited. Objective: To evaluate the feasibility of using a wrist-worn photoplethysmography (PPG) device (Lifeleaf®) in combination with a supervised learning algorithm to infer clinically useful BP measurements. Methods: A total of 87 patients undergoing electrophysiology procedures were enrolled (Table 1). Time-synchronized BP data from an intra-arterial line served as the reference. These data were divided into (1) a training set to develop a convolutional neural network (CNN) and (2) a testing set to assess the algorithm’s predictive performance. Data from 60 patients were used to train the model, and the remaining 27 patients were used for validation. Results: Data from 81 of 87 patients were included in the final analysis. The mean age was 63.6 ± 10.5 years, and 69.1% were male. A total of 6,977 paired PPG and arterial BP readings were analyzed. The mean absolute deviation for systolic BP was 13.08 ± 17.22 mm Hg, and for diastolic BP, 8.42 ± 10.56 mm Hg. Subgroup analysis revealed reduced correlation in patients with BP >140/90 mm Hg, likely due to fewer training samples in this range. Conclusion: This study demonstrates the feasibility of extracting clinically meaningful BP measurements from a PPG device using a supervised learning algorithm. The use of arterial line BP as the reference standard adds methodological rigor. Future work will focus on enhancing model performance, particularly in the hypertensive cohort.
Abstract 4370319: Early Safety Signals and Common Pitfalls of the TriClip™ System for Transcatheter Tricuspid Valve Repair: Analysis of FDA's MAUDE Database
Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available
Background: Tricuspid regurgitation (TR) can lead to right ventricular failure (RVF) and poor clinical outcomes. The TriClip™ G4 transcatheter edge-to-edge repair (TEER) system has shown improved outcomes in TR patients and received FDA approval on April 2, 2024. The FDA’s Manufacturer and User Facility Device Experience (MAUDE) database collects mandatory manufacturer reports and voluntary provider reports on device-related complications. Methods: We retrieved all TriClip™-related adverse events from the MAUDE database post-FDA approval, excluding duplicate entries and literature reviews. After removing 47 literature reviews and 36 duplicate reports, 443 unique adverse event reports from 407 procedures (some with multiple events) were analyzed between April 2, 2024, and January 31, 2025. Results: SLDA (Single Leaflet Device Attachment) was the most frequent complication, occurring in 204 cases (Figure 1). Detached leaflets included septal (105 cases), anterior (46), posterior (27), lateral (3), multiple (2), and unreported. Contributing factors included poor imaging, tethered leaflet, clip-clip interaction, dense chordae, large right atrium (RA) or gap size, pacer lead, or prior valve intervention. Persistent TR was a common consequence. SLDA was addressed with additional clips in 77 cases (18 requiring multiple clips), no intervention in 55 cases (13 with significant residual TR), repeat TriClip procedures in 16 cases, and surgical repair in 4 cases. Other complications included partial SLDA (23 cases), clip deployment or gripper malfunctions (68), chordal entanglement (41), leaflet entanglement (3), and clip migration/embolization (6). Migrated clips were found in the RA, right atrial appendage, cardiac vein, or pulmonary artery; three required snare retrieval, and three were left in place. Triclip Steerable Guide Catheter (TSGC) malfunctions, such as leaks, loss of column support, and blockages, were reported in 29 cases, with 27 requiring replacement. Miscellaneous events included residual TR, leaflet grasping issues, F-knob malfunction, lock line jams, and TSGC entanglement. Clip opening during Establishing Final Arm Angle (EFAA) occurred in 25 cases, and leaflet puncture in 15 cases, with one requiring surgical intervention. Conclusion: SLDA was the most frequently reported complication following TriClip™ approval, with some cases leading to severe outcomes. Continued surveillance is crucial to assess long-term safety and optimize procedural strategies.
Abstract 4360835: A Retrospective Analysis of Papillary Muscle PVC Ablations and Postprocedural Outcomes
Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available
Background: Papillary Muscle (PM) related ventricular arrhythmia ablation is associated with lower acute success and suboptimal long-term outcomes due to complex anatomy, variable arrhythmogenic sites and dynamic exit points. Objective: To evaluate clinical and procedural outcomes of patients undergoing PM vs non-PM ablation. Methods: A retrospective analysis of adults (≥18 years) undergoing PVC ablation at Mayo Clinic (2019–2024) matched PM PVC ablations to controls (1:2) using propensity scoring based on age, sex, comorbidities and baseline LVEF. Chi-square and t-tests compared baseline and procedural characteristics. Logistic regression estimated odds ratios for immediate procedural success, PVC burden reduction and LVEF improvement at 3 months. Results: Of the 720 ablations, 392 cases were included after propensity matching: 132 PM and 260 non-PM. Patients in the PM group exhibited higher rates of complicated diabetes (9.8% vs 4.6%, p =0.045) and prior MI (18.2% vs 9.2%, p =0.011). Preprocedural ECG PVCs in the PM group showed a shorter intrinsicoid deflection (89.1 ± 35.0 msec vs 100.7 ± 24.3 msec, p <0.001) and longer coupling intervals (532.7 ± 100.3 vs 512.2 ± 81.4 msec, p =0.048).Moderate-to-severe MR was more prevalent in the PM group (17.4% vs 10.0%, p =0.036). Intraoperatively, the PM group had higher total energy delivery times (1939 ± 1336 sec vs 1227 ± 1033 sec, p <0.001) and more frequent cryoablation use (46.2% vs 7.3%, p <0.001). During post-ablation testing, non-clinical PVC was inducible in 39.5% of the cases in PM group compared to 25.7% in non-PM group ( p =0.005). More patients in the PM group were discharged on atleast one antiarrhythmic drug (AAD)(35.9% vs 18.5%, p <0.001) and AAD use persisted at 3 months (31.3% vs 18.4%, p =0.004). Outcomes were similar between groups, with no significant differences observed in immediate ablation success (aOR 0.64, p = 0.063, CI = 0.40-1.03), or >5% improvement in LVEF (aOR 0.76, p = 0.29) and PVC burden reduction (aOR 0.93, p = 0.81) at 3 months follow up. Conclusion: Patients undergoing PM ablation exhibited higher baseline rates of comorbidities. Intraoperatively they required greater energy delivery times, and an increased use of cryoablation. Postoperatively, a larger proportion of PM ablation patients required antiarrhythmic drug therapy. Despite these complexities, PM ablation showed no significant differences in PVC burden reduction, LVEF improvement, or procedural success compared to non-PM ablation.
Abstract 4370773: Predictors of Left Ventricular Function Recovery After Premature Ventricular Complex Ablation: A Retrospective Study
Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available
Background: Catheter ablation of frequent premature ventricular complexes (PVCs) has been demonstrated to improve left ventricular ejection fraction (LVEF) in patients with PVC-induced cardiomyopathy. However, this improvement is not uniformly observed across all patients. Objective: To identify predictors of LVEF improvement following catheter ablation. Methods: This retrospective analysis included adult patients (≥18 years) who underwent PVC catheter ablation at Mayo Clinic, Rochester, between 2021 and 2024. Patients were grouped based on whether they experienced an LVEF improvement of ≥5%. Data on baseline comorbidities,, ECG characteristics, baseline transthoracic echocardiography (TTE), procedural details, and follow-up outcomes at 3-6 months (via Holter monitoring and TTE) were collected. Propensity matching (1:1) was performed using age(caliper=5), sex, and baseline LVEF(caliper=5). Comparative analyses used chi-square and t-tests. Variables with a p-value <0.1 were included in multivariate regression analysis. Results: After propensity matching, 98 patients with LVEF improvement and 98 controls were included. Table 1 summarizes baseline and procedural characteristics, and outcomes. Immediate PVC suppression was more common in the EF improvement group (74.2% vs. 60.4%, p=0.04), and fewer patients in this group were placed on long-term anti-arrhythmic medications (11.2% vs. 27.8%, p<0.01). Multivariate analysis showed that patients without PVC-related symptoms (OR=3.16, p=0.038) had higher odds of LVEF improvement, while those with CKD (OR=0.36, p=0.007) or a coupling interval ≥500 ms (OR=0.38, p=0.002) had lower odds of improvement.
Atrioventricular node ablation for refractory atrial fibrillation in patients with hypertrophic cardiomyopathy: a case–control study
Europace | September 6, 2025 | Volume: 27 | Issue: 9 | Pages: No page available