Citations

Clear

168 citation(s) found for "Cha, Yong‐Mei".

Cardiac resynchronization therapy response in cardiac sarcoidosis
Shabtaie, Samuel A. , Sehrawat, Ojasav , Lee, Justin Z. , Cha, Yong‐Mei , Mulpuru, Siva K. , Kowlgi, Gurukripa N. , Siontis, Konstantinos C. , Rosenbaum, Andrew , Bois, John P. , AbouEzzeddine, Omar F. , Asirvatham, Samuel J. , Deshmukh, Abhishek , Kowlgi, Narayan G , Rosenbaum, Andrew N , Noseworthy, Peter A , Asirvatham, Samuel J , DeSimone, Christopher V , Deshmukh, Abhishek J , AbouEzzeddine, Omar F , Noseworthy, Peter A. , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 23, 2022 | Volume: 33 | Issue: 9 | Pages: 2072-2080

10.1111/jce.15631 | PMID 35870183 Get It

AbstractIntroductionCardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS.ObjectiveTo determine if CRT improved cardiac remodeling in patients with CS.MethodsWe retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed.ResultsOur cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT‐D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT‐P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end‐diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow‐up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died.ConclusionsOur findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
A Case Report of a Wenckebach Phenomenon Occurring during a His-Bundle Pacing Procedure: Is It Atrioventricular Node Pacing?
Ma, Chengming , Li, Wen-wen , Cha, Yong‐Mei , Xia, Yunlong , Gao, Lianjun , Dong, Yingxue, Li, Wenwen , Cha, Yongmei

Mayo Clinic

Journal of Cardiovascular Development and Disease | July 19, 2022 | Volume: 9 | Issue: 7 | Pages: 231

10.3390/jcdd9070231 | PMID 35877593 Get It

A 70-year-old man with severe valvular cardiomyopathy, permanent atrial fibrillation (AF) with a slow ventricular response, and transient atrioventricular (AV) block, was admitted to our center for severe heart failure and recurrent presyncope. While hospitalized, the coronary computed tomography angiography (CTA) showed huge atriums. We tried His bundle pacing (HBP). HB potential was observed at site A, and the His-ventricular (HV) interval was 68 ms. The duration from the stimulus signal to the onset of paced QRS (S-QRSonset) at site A was 232 ms when pacing at 60 beats per minute (BPM) with the pacing threshold of 2.0 V/0.5 ms. The S-QRSonset was longer than the HV interval and had a notable and progressive prolongation from 252 ms to 456 ms during the pacing at 90 BPM. Then, we pushed another lead a little forward, and the S-QRSonset shortened back to 68 ms, and the paced QRS morphology was the same as the intrinsic QRS morphology with the pacing threshold of 1.5 V/0.5 ms. The progressively prolonged S-QRSonset demonstrated a Wenckebach phenomenon (WP), a well-known electrophysiological characteristic of the AV node (AVN). It is the first time to report an intraoperative AVN-pacing related-WP in a patient with persistent AF. The enlarged atrium might be convenient for capturing the AVN. There are some other potential explanations for this phenomenon. The diameters of atriums decreased significantly, and the symptoms improved after the procedure. This is the first reported case in which we might achieve AVN capture in a patient with persistent AF. Although we ultimately chose HBP for better long-term pacing thresholds, the result of this case suggested that AVN pacing may be possible.
Implantable cardioverter defibrillators in patients with orthotopic heart transplant: A multicenter case series
Maskoun, Waddah , Raad, Mohamad , Cha, Yong‐Mei , Houmsse, Mahmoud , Abualsuod, Amjad , Ezzeddine, Fatima M. , Pieper, Justin, Jamoor, Khaled, Tita, Cristina , Miller, John M. , Ezzeddine, Fatima

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 7, 2022 | Volume: 33 | Issue: 8 | Pages: 1813-1822

10.1111/jce.15588 | PMID 35671363 Get It

AbstractBackgroundSudden cardiac death (SCD) is common after orthotopic heart transplant (OHT). No clear guidelines for implantable cardioverter defibrillator (ICD) implantation in OHT patients at high risk for SCD currently exist.ObjectivesTo assess the safety, efficacy, and benefit of ICDs and resynchronization therapy post‐OHT. We also provide a systematic review of previous reports.MethodsA retrospective multicenter cohort study within the United States. Patients with ICD post‐OHT between 2000 and 2020 were identified.ResultsWe analyzed 16 patients from 4 centers. The mean standard‐deviation (SD) age was 43 (18) years at OHT and 51 (20) years at ICD implantation. The mean (SD) duration from OHT to ICD implantation was 9 (5) years. The mean (SD) left ventricular ejection fraction (LVEF) was 35% (17%). There were 2 (13%) postprocedural complications: 1 hematoma and 1 death. Mean (SD) follow‐up was 24 (23) months. Survival rate was 63% (10/16) at 1 year and 56% (9/16) at 2 years, with 6/7 of those who died having LVEF < 35% at the time of the ICD implantation. Patients were more likely to receive appropriate therapy if their ICD was implanted for secondary (5/8) rather than primary (0/8) prevention (p = .007). Of those who did, 4 patients survived to 30 days post‐ICD therapy. Severe CAV was not associated with the rate of appropriate therapy.ConclusionsBeneficial outcomes were observed when ICDs were implanted for secondary prevention only, and in patients with higher baseline LVEF. We also observed benefits with resynchronization therapy.
One-year outcomes of catheter ablation for atrial fibrillation in young patients
Patel, Harsh , Patel, Kirtenkumar , Jaswaney, Rahul , Thakkar, Samarthkumar , Kowlgi, Narayan G., Arora, Shilpkumar , Mulpuru, Siva K. , Madhavan, Malini , Killu, Ammar M. , Cha, Yong‐Mei , Deshmukh, Abhishek , Tseng, Andrew S. , Kumar, Ashish , Jani, Chinmay , Kowlgi, Narayan G., Dani, Sourbha S. , DeSimone, Christopher V.

Mayo Clinic

No container title available | May 18, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1399820/v1 Get It

Abstract Background: Atrial fibrillation (AF) is relatively less frequent in younger patients (age<50). Recently, studies have suggested that early restoration of sinus rhythm may lead to improved outcomes compared with rate control. Methods: We included all hospitalized patients between 18 and 50 years with a diagnosis of AF from the Nationwide Readmission Database 2016-2017 from the Healthcare Cost and Utilization Project. Demographic and comorbidity data were collected and analyzed. Outcomes assessed included one-year AF readmission rates, all-cause readmission, ischemic stroke, and all-cause mortality. Subgroup analyses were performed for all demographic and comorbidity variables.Results: Overall, 52,598 patients (medium age 44, interquartile range 38-48, female 25.7%) were included in the study, including 2,146 (4.0%) who underwent catheter ablation for AF. Patients who underwent catheter ablation had a significantly lower rate of readmission for AF or any cause at one year (adjusted hazard ratios (HR) of 0.52 [95% confidence interval (CI): 0.43-0.63] and HR of 0.81 [95% CI: 0.72 - 0.89], respectively). There was no difference in 1-year readmission for stroke or all-cause mortality between the two groups. Subgroup analyses showed a consistent reduction in the risk of AF readmission among major demographic and comorbidity subgroups.Conclusion: Catheter ablation in young patients with AF was associated with a reduction in 1-year AF related and all-cause readmissions. These data merit further prospective investigation for validation.
Abstract 10726: Cardiac Resynchronization Therapy Response in Cardiac Sarcoidosis
Shabtaie, Samuel A. , Lee, Justin Z. , Cha, Yong‐Mei , Bois, John P. , Rosenbaum, Andrew , Siontis, Konstantinos C. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V. , Kapa, Suraj , AbouEzzeddine, Omar F.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.10726 Get It

Introduction: Cardiac Sarcoidosis (CS) is a non-ischemic cardiomyopathy (NICM) characterized by infiltration of non-caseating granulomas involving in the heart with highly variable clinical manifestations. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its effectiveness in patients with CS. Hypothesis: We sought to determine if CRT improved cardiac remodeling and reduced hospitalizations in patients with CS. Methods: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at a Mayo Clinic site from 2000-2021. Baseline characteristics, echocardiographic parameters, heart failure hospitalization, and major adverse cardiac events (MACE) were assessed. Results: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. At baseline, 38 (69.1%) patients had isolated CS, while 17 (30.9%) had evidence of CS with extra-cardiac sarcoidosis. The overwhelming majority underwent CRT-D implantation (n=52, 94.5%) with 67.3% of implanted devices upgrades from prior pacemaker or implantable cardioverter defibrillator. At 6 months post-implantation there was no significant different in ejection fraction (34.8 ± 10.9 % vs. 37.7 ± 14.2 %, p = 0.237), left ventricular end systolic diameter (49.1 ± 9.9 mm vs. 45.7 ± 9.9 mm, p = 0.077) or left ventricular end-diastolic diameter (58.5 ± 10.2 mm vs. 57.5 ± 8.1 mm, p = 0.574). Within the first 6 months post-implantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow up of 4.1 ± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent LVAD implantation and 7 (12.7%) patients died. Conclusions: Our findings suggest a poor response to CRT in patients with CS with no significant evidence of reverse remodeling within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
Abstract 16562: Cardiac Device Implantation Post TAVR: Mortality and Rates of Pacemaker Dependency
Padmanabhan, Deepak , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong-Mei M, Asirvatham, Samuel, Friedman, Paul A. , Greason, Kevin L. , Gulati, Rajiv , Scott, Christopher G. , McLeod, Christopher J. , Cha, Yong-Mei M, Noseworthy, Peter A.

Mayo Clinic

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16562 Get It

Background: Transcatheter aortic valve replacement (TAVR) is often complicated by AV block requiring pacing, but whether patients recover AV conduction and whether the need for pacing affects outcomes is unknown. Methods: We retrospectively studied 534 patients who underwent TAVR at Mayo Clinic in Rochester, Minnesota between November 2008 and January 2015. Of these, 115 patients had implantable cardiac devices. Data was collected from subsequent device follow-ups to determine pacemaker dependency and percentage pacing. Results: 44 patients (8.2%) had devices implanted in the immediate post procedural period. The most common indications for implantation were high grade AV block (18 patients) and complete heart block (14 patients). 17/44 (38.6%) patients were pacemaker-dependent at implant and only 4 of these patients were no longer pacemaker-dependent during subsequent followup. The indication for pacing among these four patients was high grade atrio-ventricular block (2 patients), asystole (1 patient) and complete heart block (1). Among non-pacemaker-dependent patients, no significant change in the ventricular pacing percentages was noted over time. Survival was similar between patients who required device implantation post TAVR and those who did not after adjustment for age and gender (HR 0.73 [0.39-1.36], p=ns; figure) Conclusion: Patients requiring pacing after TAVR are often pacemaker-dependent at the time of implant. It is uncommon for patients who are dependent at the time of implant to regain AV conduction, but the need for cardiac pacing is not associated with increased mortality.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Mayo Clinic

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Arrhythmias in Female Patients: Incidence, Presentation and Management
Zeitler, Emily P. , Poole, Jeanne E. , Albert, Christine M. , Al‐Khatib, Sana M. , Ali-Ahmed, Fatima, Birgersdotter‐Green, Ulrika , Cha, Yong-Mei, Chung, Mina K. , Curtis, Anne B. , Hurwitz, Jodie L. , Lampert, Rachel , Sandhu, Roopinder K., Shaik, Fatima, Sullivan, Erin, Tamirisa, Kamala P., Wright, Jennifer M. , Russo, Andrea M. , Santos Volgman, Annabelle , Wright, Jennifer M , Russo, Andrea M , Zeitler, Emily P , Poole, Jeanne E. , Albert, Christine M. , Al-Khatib, Sana M. , Ali-Ahmed, Fatima, Birgersdotter-Green, Ulrika Maria , Cha, Yong-Mei, Chung, Mina , Curtis, Anne B. , Hurwitz, Jodie L. , Lampert, Rachel , Sandhu, Roopinder K., Shaik, Fatima, Sullivan, Erin, Tamirisa, Kamala P.

Mayo Clinic

Circulation Research | February 17, 2022 | Volume: 130 | Issue: 4 | Pages: 474-495

10.1161/circresaha.121.319893 | PMID 35175839 Get It

There is a growing appreciation for differences in epidemiology, treatment, and outcomes of cardiovascular conditions by sex. Historically, cardiovascular clinical trials have under-represented females, but findings have nonetheless been applied to clinical care in a sex-agnostic manner. Thus, much of the collective knowledge about sex-specific cardiovascular outcomes result from post hoc and secondary analyses. In some cases, these investigations have revealed important sex-based differences with implications for optimizing care for female patients with arrhythmias. This review explores the available evidence related to cardiac arrhythmia care among females, with emphasis on areas in which important sex differences are known or suggested. Considerations related to improving female enrollment in clinical trials as a way to establish more robust clinical evidence for the treatment of females are discussed. Areas of remaining evidence gaps are provided, and recommendations for areas of future research and specific action items are suggested. The overarching goal is to improve appreciation for sex-based differences in cardiac arrhythmia care as 1 component of a comprehensive plan to optimize arrhythmia care for all patients.
A wearable cardioverter defibrillator with a low false alarm rate
Poole, Jeanne E. , Gleva, Marye J. , Birgersdotter‐Green, Ulrika , Branch, Kelley R. , Salam, Tariq , Crawford, Thomas , Willcox, Mark E. , Sridhar, Arun Mahankali, Mikdadi, Ghiath, Beinart, Sean C., Cha, Yong‐Mei , Russo, Andrea M. , Rowbotham, Ron, Sullivan, Joseph, Gustavson, Laura , Kivilaid, Kaisa, Salam, Tariq , Cha, Yong-Mei , Doshi, Rahul N.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | February 17, 2022 | Volume: 33 | Issue: 5 | Pages: 831-842

10.1111/jce.15417 | PMID 35174572 Get It

AbstractIntroductionA wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort.MethodsOne hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false‐positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient‐day).ResultsOf 163 WCD episodes, 4 were VT/VF and 159 non‐VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false‐positive shock alarm markers were recorded; one false‐positive shock alarm every 1333 patient‐days (0.00075 per patient‐day, 95% confidence interval: 0.00015–0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient‐days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%).ConclusionThe ASSURE WCD demonstrated a low false‐positive shock alarm rate, low patient‐reported discomfort, and no serious adverse events.
Ventricular Arrhythmias Among Patients With Advanced Heart Failure: A Population‐Based Study
Tan, Nicholas Y. , Roger, Véronique L. , Killian, Jill M. , Cha, Yong‐Mei , Noseworthy, Peter A. , Dunlay, Shannon M. , Noseworthy, Peter A , Dunlay, Shannon

Mayo Clinic

Journal of the American Heart Association | December 22, 2021 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/jaha.121.023377 | PMID 34935408 Get It

Background The epidemiology of ventricular arrhythmias (VAs) in patients with advanced heart failure (HF) is not well defined. Methods and Results Residents of Olmsted County, Minnesota, with advanced HF from 2007 to 2017 were identified using the 2018 European Society of Cardiology criteria. Billing codes were used to capture VAs; severe VAs requiring emergency care were defined as events associated with emergency department visits or hospitalizations. The cumulative incidence of VAs postadvanced HF was estimated with the Kaplan–Meier method. Multivariable Cox analyses were used to determine the following: (1) Predictors of severe VAs postadvanced HF; and (2) Impact of severe VAs on mortality. Of 936 patients with advanced HF, 261 (27.9%) had a history of VA. The 1‐year cumulative incidence of severe VAs postadvanced HF was 5.4%. Prior VAs (hazard ratio [HR] 2.22 [95% CI, 1.26–3.89], P =0.006) and left ventricular ejection fraction <40% (HR, 3.79 [95% CI, 1.72–8.39], P <0.001) were independently associated with increased severe VA risk postadvanced HF. New‐onset severe VAs were associated with increased mortality (HR, 4.41 [95% CI, 2.80–6.94]; P <0.001), whereas severe VAs in patients with prior VAs had no significant association with mortality risk (HR, 1.08 [95% CI, 0.65–1.78]; P =0.77). Severe VAs were associated with increased mortality in patients without implantable cardioverter defibrillators (HR, 4.89 [95% CI, 2.89–8.26]; P <0.001), but not in patients with implantable cardioverter defibrillators (HR, 1.42 [95% CI, 0.92–2.19]; P =0.11). Conclusions Patients with left ventricular ejection fraction <40% and prior VAs have increased risk of severe VA postadvanced HF. New‐onset severe VAs or severe VAs without implantable cardioverter defibrillators postadvanced HF are associated with increased mortality.