Citations

Showing 10 of 108171 citations.

Sex‐stratified analysis of the safety of percutaneous left atrial appendage occlusion
Munir, Muhammad Bilal , Kawsara, Akram , Balla, Sudarshan , Daggubati, Ramesh , Osman, Mohammed , Kawsara, Akram , Munir, Muhammad Bilal , Balla, Sudarshan , Patel, Brijesh D. , Kheiri, Babikir , Michos, Erin D. , Alkhouli, Mohamad

Mayo Clinic

Catheterization and Cardiovascular Interventions | October 13, 2020 | Volume: 97 | Issue: 5 | Pages: 885-892

10.1002/ccd.29282 | PMID 33048417 Get It

AbstractObjectives and BackgroundThere is insufficient current evidence about whether sex impacts outcomes of percutaneous left atrial appendage occlusion (LAAO). The aim of this study was to investigate the association between sex and short‐term outcomes of LAAO.MethodsPatients who were hospitalized and underwent LAAO from October 2015 to December 2017 in the National Readmission Database were queried. The primary endpoint of interest was major in‐hospital adverse events. Secondary endpoints included, 30‐day readmission rate, nonhome discharge, and cost of hospitalization. Propensity score matching (1:1) was performed to compare the outcomes among women and men.ResultsA total of 9,281 patients were included in the current analysis [women = 3,659 (39%); men = 5,622 (61%)]. Comparing women to men, women had lower prevalence of diabetes mellitus (30.6% vs 35.7%, p < .01), heart failure (28.6% vs 30.8%, p = .03), vascular disease (55.5% vs 69.6%, p < .01) and renal failure (18.3% vs 21.2%, p < .01), and higher CHA2DS2VASc score (5 [IQR4‐6] vs 4 [IQR3‐6], p < .01). After propensity‐score matching, women had higher rate of major in‐hospital adverse events (2.8% vs 1.9%; p < .01), and nonhome discharges (11.4% vs 6.7%; p < .01). Additionally, 30‐day readmission rate was higher among women (10% vs 8.6%, p = .03).ConclusionAmong hospitalized patients undergoing LAAO, women carry higher risk for major in‐hospital adverse events, nonhome discharge, and 30‐day readmission rates.
Electrochemical detection of white spot syndrome virus with a silicone rubber disposable electrode composed of graphene quantum dots and gold nanoparticle-embedded polyaniline nanowires
Takemura, Kenshin , Satoh, Jun, Boonyakida, Jirayu, Park, Sungjo , Park, Enoch Y. , Chowdhury, Ankan Dutta

Mayo Clinic

No container title available | October 13, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-58911/v2 Get It

Abstract Background: With the enormous increment of globalization and global warming, it is expected that the number of newly evolved infectious diseases will continue to increase. To prevent damage due to these infections, the development of a diagnostic method for detecting a virus with high sensitivity in a short time is highly desired. In this study, we have developed a disposable electrode with high-sensitivity and accuracy to evaluate its performances for several target viruses.Results: Conductive silicon rubber (CSR) was used to fabricate a disposable sensing matrix composed of nitrogen and sulfur-co-doped graphene quantum dots (N,S-GQDs) and a gold-polyaniline nanocomposite (AuNP-PAni). A specific anti-white spot syndrome virus (WSSV) antibody was conjugated to the surface of this nanocomposite, which was successfully applied for the detection of WSSV over a wide linear range of concentration from 1.45 × 102 to 1.45 × 10⁵ DNA copies/ml, with a detection limit as low as 48.4 DNA copies/ml.Conclusion: The engineered sensor electrode can retain the detection activity up to 5 weeks, to confirm its long-term stability, required for disposable sensing applications. This is the first demonstration of the detection of WSSV by a nanofabricated sensing electrode with high sensitivity, selectivity, and stability, providing as a potential diagnostic tool to monitor WSSV in the aquaculture industry.
ATS Core Curriculum 2020. Adult Critical Care Medicine
Çoruh, Başak , Pasnick, Susan, Acho, Megan, Bass, Geoffrey D. , Card, Mary Elizabeth, Griffeth, Valerie E. M., Leveno, Matthew, Lovin, Dylan, Maximous, S. , Pearson, Steven D. , Stephens, R. Scott , Wolfe, K.S. , McSparron, Jakob I. , Kanj, Amjad , Baston, Cameron Murray , Moraes, Alice Gallo de , Zakhary, Bishoy , Hayes, Margaret M.

Mayo Clinic

ATS Scholar | October 13, 2020 | Volume: 1 | Issue: 4 | Pages: 436-455

10.34197/ats-scholar.2020-0015re | PMID 33870312 Get It

Abstract The American Thoracic Society Core Curriculum updates clinicians annually in adult and pediatric pulmonary disease, medical critical care, and sleep medicine, in a 3- to 4-year recurring cycle of topics. These topics will be presented at the 2020 International Conference. Below is the adult critical care medicine core including complications of chemotherapy, acute-on-chronic liver failure, alcohol withdrawal syndrome, mechanical circulatory support, direct oral anticoagulants, upper gastrointestinal hemorrhage, and vasopressor selection.
Manejo de heridas traumáticas de difícil cicatrización con colgajos microvasculares
Ciudad, Pedro , Vargas, María Inés, Castillo-Soto, Ana , Sanchez, Jefferson R., Manrique, Oscar J. , Forte, Antonio J. , Huayllani, María T. , Soto, Zoila, Forte, Antonio Jorge , Bustos, Samyd S. , Grández-Urbina, J. Antonio

Mayo Clinic

Journal of Wound Care | October 13, 2020 | Volume: 29 | Issue: Sup10 | Pages: 27-34

10.12968/jowc.2020.29.sup10.27 | PMID 33048015 Get It

SinopsisObjetivo:El objetivo de este estudio fue presentar diferentes opciones de manejo de heridas de difícil cicatrización utilizando colgajos libres microvasculares.Método:Se llevó a cabo una revisión retrospectiva de todos los pacientes con heridas traumáticas de difícil cicatrización, a quienes se les realizó reconstrucción con colgajo libre. Se analizaron datos demográficos, etiología de la herida, diagnóstico, tratamiento previo de la herida, tipo de colgajo utilizado, dimensiones del defecto y del colgajo, vasos receptores, complicaciones, y seguimiento.Resultados:En total, 20 pacientes fueron sometidos a reconstrucciones con colgajos libres. La edad promedio fue de 39,5 años. Se realizaron 20 colgajos libres, entre ellos: 3 de piernas cruzadas, 1 de piernas cruzadas con puente vascular, 2 osteocutáneos de peroné, 6 fasciocutáneos anterolateral del muslo, 3 perforantes de la arteria toracodorsal, 3 miocutáneos dorsal ancho, y 2 fasciocutáneos de la perforante de la arteria femoral profunda. Un paciente requirió revisión de anastomosis microvascular debido a un hematoma. El resto de los pacientes no presentó intercurrencias en el postoperatorio. Respecto al tratamiento previo, 12 pacientes recibieron terapia de presión negativa, mientras que 8 tuvieron desbridamientos quirúrgicos con subsecuente aplicación de hidrogel con plata iónica.Conclusión:Las heridas de difícil cicatrización no tienen una buena respuesta al tratamiento convencional con curaciones, injertos o colgajos locales, sino que requieren la transferencia de tejidos similares a los que se han perdido. Las técnicas microvasculares pueden ser una alternativa.
False‐negative solid‐phase platelet crossmatch results due to prozone phenomenon
Horton, Rachel K. , Zuccarelli, Micah D., Wakefield, Laurie L., DiGuardo, Margaret , Gandhi, Manish J. , Juskewitch, Justin E. , DiGuardo, Margaret A , Gandhi, Manish , Juskewitch, Justin E

Mayo Clinic

Transfusion | October 13, 2020 | Volume: 60 | Issue: 12 | Pages: 3055-3059

10.1111/trf.16132 | PMID 33047855 Get It

BackgroundProzone is a known phenomenon affecting immunoassays causing falsely low or negative results when excess target is present in the test system. For assays used to evaluate immune‐mediated platelet (PLT) transfusion refractoriness, prozone‐like phenomenon has been described in solid‐phase human leukocyte antigen (HLA) antibody testing and can be mitigated by diluting samples or pretreating samples with ethylenediaminetetraacetic acid (EDTA) or dithiothreitol. Prozone phenomenon has not yet been described in solid‐phase red blood cell (RBC) adherence PLT crossmatch assays.Case ReportA 40‐year‐old female with myeloid sarcoma and PLT transfusion refractoriness underwent repeated solid‐phase PLT crossmatches; however, crossmatch‐compatible PLTs units did not yield adequate PLT count responses. Class I HLA antibody testing with neat, diluted, and EDTA‐pretreated serum demonstrated significant prozone‐like effect and the presence of numerous high strength HLA antibodies. Based on this HLA antibody profile, HLA antigen–negative PLTs gave an adequate PLT count response. It was noted that the HLA types of her crossmatch‐compatible PLTs were incompatible with her HLA antibody profile (eg, HLA‐A2). With ABO‐identical, HLA‐A2–positive PLT units, a solid‐phase PLT crossmatch was repeated using undiluted and diluted EDTA plasma. Undiluted EDTA plasma demonstrated negative or weakly positive PLT crossmatches while the diluted EDTA plasma demonstrated strongly positive PLT crossmatches.ConclusionThe prozone phenomenon can cause false‐negative results in solid‐phase RBC adherence PLT crossmatch assays, which can be mitigated with sample dilution. In immune‐mediated PLT transfusion–refractory patients with high‐strength HLA antibodies, sample dilution should be considered to correctly identify compatible PLT inventory.
Prospective Frontal Plane Angles Used to Predict ACL Strain and Identify Those at High Risk for Sports-Related ACL Injury
Myer, Gregory D. , Hale, Rena F. , Schilaty, Nathan D. , Hewett, Timothy E. , Bates, Nathaniel A. , Schilaty, Nathan D , Myer, Gregory D

Mayo Clinic

Orthopaedic Journal of Sports Medicine | October 13, 2020 | Volume: 8 | Issue: 10 | Pages: No page available

10.1177/2325967120957646 | PMID 33110927 Get It

Background: Knee abduction moment during landing has been associated with anterior cruciate ligament (ACL) injury. However, accurately capturing this measurement is expensive and technically rigorous. Less complex variables that lend themselves to easier clinical integration are desirable. Purpose: To corroborate in vitro cadaveric simulation and in vivo knee abduction angles from landing tasks to allow for estimation of ACL strain in live participants during a landing task. Study Design: Descriptive laboratory study. Methods: A total of 205 female high school athletes previously underwent prospective 3-dimensional motion analysis and subsequent injury tracking. Differences in knee abduction angle between those who went on to develop ACL injury and healthy controls were assessed using Student t tests and receiver operating characteristic analysis. A total of 11 cadaveric specimens underwent mechanical impact simulation while instrumented to record ACL strain and knee abduction angle. Pearson correlation coefficients were calculated between these variables. The resultant linear regression model was used to estimate ACL strain in the 205 high school athletes based on their knee abduction angles. Results: Knee abduction angle was greater for athletes who went on to develop injury than for healthy controls ( P < .01). Knee abduction angle at initial contact predicted ACL injury status with 78% sensitivity and 83% specificity, with a threshold of 4.6° of knee abduction. ACL strain was significantly correlated with knee abduction angle during cadaveric simulation ( P < .01). Subsequent estimates of peak ACL strain in the high school athletes were greater for those who went on to injury (7.7-8.1% ± 1.5%) than for healthy controls (4.1-4.5% ± 3.6%) ( P < .01). Conclusion: Knee abduction angle exhibited comparable reliability with knee abduction moment for ACL injury risk identification. Cadaveric simulation data can be extrapolated to estimate in vivo ACL strain. Athletes who went on to ACL injury exhibited greater knee abduction and greater ACL strain than did healthy controls during landing. Clinical Relevance: These important associations between the in vivo and cadaveric environments allow clinicians to estimate peak ACL strain from observed knee abduction angles. Neuromuscular control of knee abduction angle during dynamic tasks is imperative for knee joint health. The present associations are an important step toward the establishment of a minimal clinically important difference value for ACL strain during landing.
Long non‑coding RNA expression profiles identify lncRNA‑XLOC_I2_006631 as a potential novel blood biomarker for Hashimoto's thyroiditis
Peng, Huiyong , Xiong, Si , Ding, Xiangmei, Tang, Xinyi , Wang, Xuehua , Wang, Li , Liu, Yingzhao

Mayo Clinic

International Journal of Molecular Medicine | October 13, 2020 | Volume: 46 | Issue: 6 | Pages: 2172-2184

10.3892/ijmm.2020.4755 | PMID 33125100 Get It

Physician burnout: Quo vadimus?
Agrawal, Varun , Ghosh, Amit K. , Menon, Vikas , Joshi, Shashank R

Mayo Clinic

Indian Journal of Medical Sciences | October 13, 2020 | Issue: No issue available | Pages: 1-6

10.25259/ijms_23_2020 Get It

Burnout is a syndrome of emotional exhaustion, loss of meaning at work, feeling of ineffectiveness, and a tendency to view people as objects rather than as a human being. Physician burnout leads to dissatisfaction at work and suboptimal patient care. Various causes of burnout at the individual, work environment, and health system levels have been identified. In this review, we initially focus on the burden of burnout. Subsequently, we describe the determinants of this problem in India and the West, while drawing on relevant literature. Finally, we provide evidence based practical suggestions to deal with physician burnout. Strategies suggested to deal with burnout need to be implemented based on locally available resources. Repeated assessment of burnout constructs using validated questionnaires can evaluate the effectiveness of an intervention. Hospitals, educational institutions, and physician societies need to collaborate with practicing physicians to address burnout and invest in physician well-being to continue providing high-quality medical care in the future.
Vascularized Lymph Node Transfer to the Thigh: A Novel Technical Modification
Teven, Chad M. , Bryant, Lyndsey A. , Struve, Sara L., Rebecca, Alanna M. , Hammond, Jacob B.

Mayo Clinic

Plastic & Reconstructive Surgery | October 13, 2020 | Volume: 147 | Issue: 1 | Pages: 182e-184e

10.1097/prs.0000000000007483 | PMID 33048848 Get It