Citations

Clear

47 citation(s) found for "Scott, Luis".

Abstract 10567: Sepsis-Related Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10567 Get It

Background: Recognition of the infectious characteristics among the sepsis-related early mortality after transvenous lead removal (TLR) is an essential step to improving patient outcomes. Objective: This study sought to understand the infectious characteristic and circumstances among the sepsis-related early mortality after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Patient details were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 2,319 patients were included in the study. The overall 30-day sepsis-related mortality rate was 1.25% (n=29). Among the sepsis-related deaths, 24 patients (83%) had systemic cardiac implantable electronic device (CIED) infection, and 4 patients (14%) initially had isolated pocket infection. The average time from admission to TLR was 11 days. MSSA was the most common organism (n=8, 28%), and this was followed by MRSA (n=4, 14%) and Candida (n=3, 10%). Twenty of these patients (69%) had vegetation on the echocardiogram: vegetation on lead only in 9 patients, vegetation on both valve and lead in 8 patients, and vegetation on valve only in 3 patients. Among valvular vegetations, 5 patients had tricuspid valve vegetations, 3 patients had aortic valve vegetations, 2 patients had mitral valve vegetations, and 1 patient had both mitral and aortic valve vegetation. The average size of vegetation was 1.3±0.8 x 1.1±0.6 cm. Conclusions: The 30-day sepsis-related mortality rate was 1.25%. Among the sepsis-related early deaths, MSSA was the most common organism, and more than two-thirds (69%) of the patients had vegetations on cardiac imaging. This highlights the importance of further research to improve the infection outcome in TLR patients.
Abstract 10559: Causes of Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10559 Get It

Background: Recognition of the causes of early mortality after transvenous lead removal (TLR) is an essential step for the development of quality improvement programs. Objective: This study sought to determine the causes of early mortality after TLR and to further understand the circumstances surrounding death after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. The causes of death were further characterized based on whether it was related to the TLR procedure. Results: A total of 2,319 patients were included in the study. The overall 30-day all-cause mortality rate was 3%. Among all 30-day deaths, infection was the most common primary cause of death (42%). This was followed by decompensated heart failure (17%), procedure-related death (10%), sudden cardiac arrest (7%), and respiratory failure (6%). The 30-day mortality rate directly due to complications associated with the TLR procedure was 0.3% due to vascular tear and cardiac perforation. A third of deaths (33%) occurred after discharge from index hospitalization, among which 43% were readmitted before their death, 35% died at home or a nursing facility, and 22% were discharged on comfort care and died in hospice. The main reasons for readmission prior to death were sepsis and decompensated heart failure. Conclusions: The majority (90%) of 30-day mortality after TLR was not due to complications associated with TLR procedures. The primary causes were infection and decompensated heart failure. This highlights the importance of further research to reduce postoperative mortality from these factors, including deaths after hospital discharge.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Tan, Min Choon , Karikalan, Suganya Arunachalam , Deshmukh, Abhishek , Srivathsan, Komandoor , Scott, Luis R. , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Munger, Thomas M. , Lee, Justin Z. , Karikalan, Suganya , Deshmukh, Abhishek J , Srivathsan, Komandoor , Scott, Luis R , McLeod, Christopher J , Asirvatham, Samuel J , Noseworthy, Peter A , Deshmukh, Abhishek J , Tan, Min C , Rattanawong, Pattara

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available

10.1161/circep.122.011365 | PMID 37082954 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
Incidentally Discovered Right Atrial Mass: A Rare and Unexpected Etiology
Sykora, Daniel , Chaliki, Hari P. , Cummings, Kristopher W. , Stanton, Melissa, Scott, Luis R. , Sell-Dottin, Kristen, Stanton, Melissa L, Sell‐Dottin, Kristen

Mayo Clinic

Texas Heart Institute Journal | April 15, 2023 | Volume: 50 | Issue: 2 | Pages: No page available

10.14503/thij-21-7735 | PMID 37060553 Get It

Abstract Primary cardiac sarcoma is a rare type of intracardiac mass. This report describes a patient with atrial flutter who had a new right atrial mass incidentally discovered on transesophageal echocardiography. A thrombus was suspected based on radiographic appearance, but there was minimal change with anticoagulation. The mass was resected and found to be an undifferentiated pleomorphic cardiac sarcoma, an uncommon sub-type within the already rare category of primary cardiac neoplasms. This report highlights the importance of considering primary malignancy and thoroughly correlating radiographic and clinical evidence during the diagnostic workup of patients with intracardiac masses.
Influence of endurance sports on atrial fibrillation ablation outcomes
Liu, Michael B. , Lee, Justin Z. , Klooster, Lindsay, Petty, Skye A. Buckner, Scott, Luis R. , Buckner Petty, Skye A, Liu, Michael

Mayo Clinic

Journal of Arrhythmia | July 15, 2022 | Volume: 38 | Issue: 5 | Pages: 694-709

10.1002/joa3.12746 | PMID 36237855 Get It

AbstractObjectivesWe aimed to investigate the outcomes of pulmonary vein isolation in athletes.MethodsWe retrospectively identified endurance athletes who underwent catheter ablation at our institution (2004–2018). Endurance athletes were defined as participating in competitive athletics for at least 1500 lifetime hours in sports at the IB or IIA Bethesda classification or higher. Primary endpoints were freedom from atrial arrhythmias at 12, 24, and 36 months after the procedure. Secondary endpoints were defined as qualitative improvement in symptoms allowing athletes to return to their previous level of activity. Athletes were compared with a control group of nonathletes in a 3‐to‐1 matched analysis by age and sex.ResultsA total of 39 endurance athletes who underwent catheter ablation were identified during the study period. At 12 months, there was no difference in treatment outcomes for athletes versus nonathletes (relative risk [RR], 1.06; 95% CI, 0.92–1.22; p = .40). Freedom from atrial arrhythmias was 35% less likely in athletes than nonathletes at 24 months (RR, 0.65; 95% CI, 0.50–0.83; p < .001) and 42% less likely at 36 months (RR, 0.58; 95% CI, 0.41–0.79; p < .001). Overall, 77% of the athletes were able to return to their previous level of activity following catheter ablation.ConclusionEndurance athletes with atrial fibrillation appear to have higher rates of atrial arrhythmia recurrence than nonathletes after catheter ablation, with higher rates of atypical flutter. The majority of athletes were able to return to their previous level of activity after ablation.
Optogenetic Control of Engrafted Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes in Live Mice: A Proof-of-Concept Study
Joshi, Jyotsna, Xu, Bing , Rubart, Michael , Bao, Xiaoping , Chaliki, Hari P. , Scott, Luis R. , Zhu, Wuqiang , Bao, Xiaoping , Zhu, Wuqiang , Rubart, Michael , Chang, Yun

Mayo Clinic

Cells | March 10, 2022 | Volume: 11 | Issue: 6 | Pages: 951

10.3390/cells11060951 | PMID 35326403 Get It

Background: Cellular transplantation has emerged as promising approach for treating cardiac diseases. However, a poor engraftment rate limits our understanding on how transplanted cardiomyocytes contribute to cardiac function in the recipient’s heart. Methods: The CRISPR/Cas9 technique was employed for stable and constitutive gene expression in human-induced pluripotent stem-cell-derived cardiomyocytes (hiPSC-CMs). Myocardial infarction was induced in adult immunodeficient mice, followed by intramyocardial injection of hiPSC-CMs expressing either CCND2/channelrhodopsin 2 (hiPSC-CCND2OE/ChR2OECMs) or CCND2/luciferase (hiPSC-CCND2OE/LuciOECMs). Six months later, hemodynamics and intramural electrocardiogram were recorded upon blue light illuminations in anesthetized, open-chest mice. Results: Blue light resets automaticity of spontaneously beating hiPSC-CCND2OE/ChR2OECMs in culture, but not that of hiPSC-CCND2OE/LuciOECMs. Response to blue light was also observed in mice carrying large (>106 cells) intracardiac grafts of hiPSC-CCND2OE/ChR2OECM but not in mice carrying hiPSC-CCND2OE/LuciOECMs. The former exhibited single premature ventricular contractions upon light illumination or ventricular quadrigeminy upon second-long illuminations. At the onset of premature ventricular contractions, maximal systolic ventricular pressure decreased while ventricular volume rose concomitantly. Light-induced changes reversed upon resumption of sinus rhythm. Conclusions: We established an in vivo model for optogenetic-based modulation of the excitability of donor cardiomyocytes in a functional, reversible, and localized manner. This approach holds unique value for studying electromechanical coupling and molecular interactions between donor cardiomyocytes and recipient hearts in live animals.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Mayo Clinic

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
Minaskeian, Nareg , Hajnal, Sofia Pannunzio, Liu, Michael B. , Klooster, Lindsay, Devick, Katrina L. , Schwartz, Linda, Jokerst, Clinton, Sorajja, Dan , Scott, Luis, Hajnal, Sofia P, Klooster, Lindsay M, Scott, Luis Rp, Schwartz, Linda

Mayo Clinic

Journal of Applied Clinical Medical Physics | January 23, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13520 | PMID 35066975 Get It

AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers
Kowlgi, Gurukripa N. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon-Chi , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Kowlgi, Narayan G , Tseng, Andrew S. , Asirvatham, Samuel J.

Mayo Clinic

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1 Get It

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Liposomal bupivacaine during subcutaneous implantable cardioverter defibrillator implantation for pain management
Lee, Justin Z. , Glasgow, Amy E. , Habermann, Elizabeth B. , Scott, Luis R. , Shen, Win‐Kuang , Kusumoto, Fred , Goel, Vasudha , Kaginele, Pranita , Cha, Yong‐Mei , Friedman, Paul A. , Asirvatham, Samuel J. , Mulpuru, Siva K. , Glasgow, Amy E. , Kusumoto, Fred M , Cha, Yong-Mei , Friedman, Paul A , Asirvatham, Samuel J , Habermann, Elizabeth , Glasgow, Amy E , McLeod, Christopher J.

Mayo Clinic

Pacing and Clinical Electrophysiology | January 25, 2021 | Volume: 44 | Issue: 3 | Pages: 513-518

10.1111/pace.14175 | PMID 33494121 Get It

AbstractBackgroundThe subcutaneous implantable cardioverter‐defibrillator (S‐ICD) has a larger generator and its implantation involves more dissection and tunneling compared to traditional transvenous defibrillator system. Liposomal bupivacaine, an extended‐release bupivacaine with 72 h of duration has been used for postoperative pain management in patients undergoing S‐ICD implantation. Our aim was to compare postoperative pain and opioid prescription patterns among patients undergoing S‐ICD implantation who received intraprocedural liposomal bupivacaine and those who did not.MethodsWe performed a retrospective analysis of all patients who underwent subcutaneous ICD implantation from January 1, 2013 to March 30, 2018 at the Mayo Clinic in Rochester, Minnesota. Patients were categorized into those who received liposomal bupivacaine and those who did not. Data on inpatient pain score, outpatient opioid prescription rates at discharge, and doses based on oral morphine equivalents (OME) were collected.ResultsA total of 104 patients underwent S‐ICD implantation. Intraprocedural liposomal bupivacaine was used in 69% of patients. Patients who received intraprocedural liposomal bupivacaine had similar mean inpatient pain scores (2.9 vs. 2.9, p = .786). There was also no difference in the rate of inpatient opioid administration (79.2% vs. 87.5%, p = .4139), outpatient opioid prescription (23.6% vs. 12.5%, p = .29), or mean OME (41.7‐mg vs. 16.6‐mg, p = .188) when comparing patients those who received intraprocedural liposomal bupivacaine and those who did not.ConclusionIntraprocedural liposomal bupivacaine administration was not associated with any significant impact on postoperative pain scores, inpatient opioid administration, and outpatient opioid prescription rates or OME amounts at discharge.