Compound Muscle Action Potential (CMAP) Duration and Myosin Loss in Patients with Critical Illness Myopathy: Correlation and Prognostication (P1-11.005)
Accelerated Endothelial Dysfunction in Migraine with Aura Compared to Migraine Without Aura in Patients of Different Age and Sex Groups Identified by an Artificial Intelligence-ECG Age-estimation Algorithm (P5-12.001)
Efficacy and Safety of Ravulizumab in Adults With Anti-Aquaporin-4 Antibody-Positive Neuromyelitis Optica Spectrum Disorder (AQP4+ NMOSD): Interim Analysis From the Ongoing Phase 3 CHAMPION-NMOSD Trial (S32.003)
Objective The aim of this study was to assess the diagnostic utility of cerebrospinal fluid (CSF) myelin oligodendrocyte glycoprotein antibodies (MOG‐IgG) testing. Methods We retrospectively identified patients for CSF MOG‐IgG testing from January 1, 1996, to May 1, 2023, at Mayo Clinic and other medical centers that sent CSF MOG‐IgG for testing including: controls, 282; serum MOG‐IgG positive MOG antibody‐associated disease (MOGAD), 74; serum MOG‐IgG negative high‐risk phenotypes, 73; serum false positive MOG‐IgG with alternative diagnoses, 18. A live cell‐based assay assessed CSF MOG‐IgG positivity (IgG‐binding‐index [IBI], ≥2.5) using multiple anti‐human secondary antibodies and end‐titers were calculated if sufficient sample volume. Correlation of CSF MOG‐IgG IBI and titer was assessed. Results The pan‐IgG Fc‐specific secondary was optimal, yielding CSF MOG‐IgG sensitivity of 90% and specificity of 98% (Youden's index 0.88). CSF MOG‐IgG was positive in: 4/282 (1.4%) controls; 66/74 (89%) serum MOG‐IgG positive MOGAD patients; and 9/73 (12%) serum MOG‐IgG negative patients with high‐risk phenotypes. Serum negative but CSF positive MOG‐IgG accounted for 9/83 (11%) MOGAD patients, and all fulfilled 2023 MOGAD diagnostic criteria. Subgroup analysis of serum MOG‐IgG low‐positives revealed CSF MOG‐IgG positivity more in MOGAD (13/16[81%]) than other diseases with false positive serum MOG‐IgG (3/15[20%]) ( p = 0.01). CSF MOG‐IgG IBI and CSF MOG‐IgG titer (both available in 29 samples) were correlated (Spearman's r = 0.64, p < 0.001). Interpretation CSF MOG‐IgG testing has diagnostic utility in patients with a suspicious phenotype but negative serum MOG‐IgG, and those with low positive serum MOG‐IgG results and diagnostic uncertainty. These findings support a role for CSF MOG‐IgG testing in the appropriate clinical setting. ANN NEUROL 2024;96:34–45
Impact of BMI on Dyspnea and Need for Surgical Intervention in Bilateral Vocal Fold Immobility
AbstractObjectiveBilateral vocal fold paralysis (BVFP) and posterior glottic stenosis (PGS) are causes of bilateral vocal fold immobility (BVFI) and may cause shortness of breath, stridor, and need for surgical intervention. Although increased body mass index (BMI) is associated with restrictive breathing patterns in patients with normal upper airways, it is unclear how BMI impacts dyspnea and need for surgical intervention in BVFI patients.Study DesignRetrospective cohort study.SettingThree tertiary academic centers in the United States.MethodsDemographics, BMI, Dyspnea Index (DI), etiology, presence of tracheostomy and surgical intervention (dilation, tracheostomy, cordotomy, arytenoidectomy, open reconstruction) were collected. Primary outcomes included dyspnea measured by DI and need for surgery to improve airway. Linear regressions were performed to assess continuous outcomes. Mann‐Whitney U‐test was utilized to assess categorical outcomes.ResultsAmong 121 patients, 52 presented with BVFP and 69 with PGS. Previous neck surgery was the most common cause of BVFI (40.2%). 44.3% of patients received a tracheostomy. Through multivariate linear regression, increased BMI was significantly associated with increased DI in the entire cohort (β = .43, P = .016). Increased BMI was also associated with need for any surgical intervention (odds ratio [OR] = 1.07, 95% confidence interval [CI] = [1.01‐1.13]) in the overall cohort. When stratifying our data, BMI was only significantly associated with DI in BVFP (β = .496) and need for surgical intervention in PGS (OR = 1.11, 95% CI = [1.01‐1.21]), although a positive trend was seen in all analyses.ConclusionIncreased BMI may correlate with worsening dyspnea symptoms and need for surgical intervention in patients with BVFI. Weight‐loss‐related counseling may benefit symptom management.
3D printed phantom with 12 000 submillimeter lesions to improve efficiency in CT detectability assessment
AbstractBackgroundThe detectability performance of a CT scanner is difficult to precisely quantify when nonlinearities are present in reconstruction. An efficient detectability assessment method that is sensitive to small effects of dose and scanner settings is desirable. We previously proposed a method using a search challenge instrument: a phantom is embedded with hundreds of lesions at random locations, and a model observer is used to detect lesions. Preliminary tests in simulation and a prototype showed promising results.PurposeIn this work, we fabricated a full‐size search challenge phantom with design updates, including changes to lesion size, contrast, and number, and studied our implementation by comparing the lesion detectability from a nonprewhitening (NPW) model observer between different reconstructions at different exposure levels, and by estimating the instrument sensitivity to detect changes in dose.MethodsDesigned to fit into QRM anthropomorphic phantoms, our search challenge phantom is a cylindrical insert 10 cm wide and 4 cm thick, embedded with 12 000 lesions (nominal width of 0.6 mm, height of 0.8 mm, and contrast of −350 HU), and was fabricated using PixelPrint, a 3D printing technique. The insert was scanned alone at a high dose to assess printing accuracy. To evaluate lesion detectability, the insert was placed in a QRM thorax phantom and scanned from 50 to 625 mAs with increments of 25 mAs, once per exposure level, and the average of all exposure levels was used as high‐dose reference. Scans were reconstructed with three different settings: filtered‐backprojection (FBP) with Br40 and Br59, and Sinogram Affirmed Iterative Reconstruction (SAFIRE) with strength level 5 and Br59 kernel. An NPW model observer was used to search for lesions, and detection performance of different settings were compared using area under the exponential transform of free response ROC curve (AUC). Using propagation of uncertainty, the sensitivity to changes in dose was estimated by the percent change in exposure due to one standard deviation of AUC, measured from 5 repeat scans at 100, 200, 300, and 400 mAs.ResultsThe printed insert lesions had an average position error of 0.20 mm compared to printing reference. As the exposure level increases from 50 mAs to 625 mAs, the lesion detectability AUCs increase from 0.38 to 0.92, 0.42 to 0.98, and 0.41 to 0.97 for FBP Br40, FBP Br59, and SAFIRE Br59, respectively, with a lower rate of increase at higher exposure level. FBP Br59 performed best with AUC 0.01 higher than SAFIRE Br59 on average and 0.07 higher than FBP Br40 (all P < 0.001). The standard deviation of AUC was less than 0.006, and the sensitivity to detect changes in mAs was within 2% for FBP Br59.ConclusionsOur 3D‐printed search challenge phantom with 12 000 submillimeter lesions, together with an NPW model observer, provide an efficient CT detectability assessment method that is sensitive to subtle effects in reconstruction and is sensitive to small changes in dose.
Early Serial Assessment of Aggregate Vasoactive Support and Mortality in Cardiogenic Shock: Insights From the Critical Care Cardiology Trials Network Registry
BACKGROUND: Associations of early changes in vasoactive support with cardiogenic shock (CS) mortality remain incompletely defined. METHODS: The Critical Care Cardiology Trials Network is a multicenter registry of cardiac intensive care units. Patients admitted with CS (2018–2023) had vasoactive dosing assessed at 4 and 24 hours from cardiac intensive care unit admission and quantified by the vasoactive-inotropic score (VIS). Prognostic associations of VIS at both time points, as well as change in VIS from 4 to 24 hours, were examined. Interaction testing was performed based on mechanical circulatory support status. RESULTS: Among 3665 patients, 82% had a change in VIS <10, with 7% and 11% having a ≥10-point increase and decrease from 4 to 24 hours, respectively. The 4 and 24-hour VIS were each associated with cardiac intensive care unit mortality (13%–45% and 11%–73% for VIS <10 to ≥40, respectively; P trend <0.0001 for each). Stratifying by the 4-hour VIS, changes in VIS from 4 to 24 hours had a graded association with mortality, ranging from a 2- to >4-fold difference in mortality comparing those with a ≥10-point increase to ≥10-point decrease in VIS ( P trend <0.0001). The change in VIS alone provided good discrimination of cardiac intensive care unit mortality (C-statistic, 0.72 [95% CI, 0.70–0.75]) and improved discrimination of the 24-hour Sequential Organ Failure Assessment score (0.72 [95% CI, 0.69–0.74] to 0.76 [95% CI, 0.74–0.78]) and the clinician-assessed Society for Cardiovascular Angiography and Interventions shock stage (0.72 [95% CI, 0.70–0.74] to 0.77 [95% CI, 0.75–0.79]). Although present in both groups, the mortality risk associated with VIS was attenuated in patients managed with versus without mechanical circulatory support (odds ratio per 10-point higher 24-hour VIS, 1.36 [95% CI, 1.23–1.49] versus 1.84 [95% CI, 1.69–2.01]; P interaction <0.0001). CONCLUSIONS: Early changes in the magnitude of vasoactive support in CS are associated with a gradient of risk for mortality. These data suggest that early VIS trajectory may improve CS prognostication, with the potential to be leveraged for clinical decision-making and research applications in CS.