Citations

Clear

151 citation(s) found for "DeSimone, Christopher V".

Impact of Timing of Atrial Fibrillation Ablation on AF Recurrence and Clinical Outcomes in Patients With HFpEF and HFrEF
Eisa, Mahmoud , Elbenawi, Hossam , Deshmukh, Abhishek J., DeSimone, Christopher V., DeSimone, Christopher V. , Deshmukh, Abhishek J , DeSimone, Christopher V , Deshmukh, Abhishek

Mayo Clinic

Journal of Cardiovascular Electrophysiology | January 14, 2026 | Volume: 37 | Issue: 4 | Pages: 898-899

10.1111/jce.70247 | PMID 41528062 Get It

Propensity‐Matched Five‐Year Cardiac Resynchronization Therapy Outcomes in Sarcoidosis With Heart Failure
Yeo, Yong Hao , Ong, Tze Ern , Tan, Min Choon , Vigneswaramoorthy, Nishanthi, Scott, Luis R. , Masry, Hicham El , Sorajja, Dan , Deshmukh, Abhishek , DeSimone, Christopher V. , Lee, Justin Z. , Tan, Min C , El Masry, Hicham , Deshmukh, Abhishek J , DeSimone, Christopher V , Yeo, Yong Hao , Vignarajah, Aravinthan

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 25, 2025 | Volume: 37 | Issue: 1 | Pages: 119-125

10.1111/jce.70204 | PMID 41286588 Get It

ABSTRACT Introduction Cardiac resynchronization therapy (CRT) improves clinical outcomes in patients with heart failure with reduced ejection fraction (HFrEF). However, data on its efficacy in patients with sarcoidosis and HFrEF are limited. Methods Using the TriNetX network, we identified patients with sarcoidosis, heart failure with a left ventricular ejection fraction (LVEF) below 35%, and either left bundle branch block (LBBB) or prolonged QRS duration ( > 150 ms) between 2014 and 2019. Patients were categorized into two cohorts: (1) those who received CRT and (2) those who received an ICD‐only implant. Five‐year outcomes included all‐cause mortality, all‐cause hospitalization, heart failure exacerbation, and the proportion of patients with improvement in LVEF to greater than 40% and greater than 50%. Results Out of 245 eligible patients, we identified a cohort of 87 patients (mean age 62.6 ± 9.5 years) who received CRT and 87 patients (mean age 62.1 ± 11.1 years) who received ICD‐only implant, with similar propensity scores, and included them in a comparative analysis. At 5‐year follow‐up, the CRT group demonstrated outcomes comparable to the ICD‐only implant group for all‐cause mortality (14.9% vs. 20.7%; HR 0.63; 95% CI 0.31–1.28; p = 0.19), all‐cause hospitalization (83.9% vs. 77.0%; HR 1.24; 95% CI 0.89–1.73; p = 0.19), and heart failure exacerbation (28.7% vs. 28.7%; HR 0.90; 95% CI 0.52–1.57; p = 0.72). The proportion of patients with improvement in LVEF to greater than 40% and greater than 50% was also similar in both groups (LVEF > 40%, 43.7% vs. 33.3%; HR 1.30; 95% CI 0.80–2.10; p = 0.29; LVEF > 50%, 31.0% vs. 17.2%; HR 1.72; 95% CI 0.92–3.24; p = 0.09). Conclusion CRT implantation had similar long‐term outcomes compared to ICD‐only implantation in patients with sarcoidosis and HFrEF, particularly all‐cause mortality, all‐cause hospitalization, heart failure exacerbation, and the proportion of patients with improvement in LVEF to greater than 40% and greater than 50%.
Outcomes of Transvenous Lead Removal in Patients With Prior Mediastinal Radiation
Patel, Harsh , Munir, Muhammad Bilal , Sugrue, Alan , Tan, Nicholas Y. , Munoz, Freddy Del‐Carpio , Cha, Yong‐Mei , Mulpuru, Siva K. , Deshmukh, Abhishek , Agarwal, Siddharth , DeSimone, Daniel, Munir, Muhammad Bilal , Agarwal, Siddharth , Agarwal, Siddharth, Asad, Zain Ul Abideen , DeSimone, Daniel C. , DeSimone, Christopher V. , Deshmukh, Abhishek

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 18, 2025 | Volume: 37 | Issue: 1 | Pages: 186-189

10.1111/jce.70192 | PMID 41250637 Get It

ABSTRACT Background Transvenous lead removal (TLR) in patients with a history of mediastinal radiation poses unique challenges due to potential radiation‐induced fibrosis, vascular changes, and anatomical distortion, which may increase procedural complexity and complication risk. However, contemporary data on clinical outcomes in this population remain limited. Methods We analyzed the National Readmissions Database (2016–2021) to identify adults (≥ 18 years) undergoing TLR. Patients were stratified by prior mediastinal radiation. Baseline characteristics were compared using standard statistical tests. Multivariable logistic regression was used to evaluate the association between prior mediastinal radiation and in‐hospital outcomes, 30‐day mortality, and 30‐day readmissions after adjustment for demographics and comorbidities. Results A total of 48,985 patients underwent TLR, of whom 735 (1.5%) had a history of mediastinal radiation. Compared with patients without radiation, those with prior radiation were older (70.1 vs. 66.2 years, p < 0.01), were more frequently females (38.2% vs. 31.6%, p < 0.01), and had higher rates of valvular heart disease, atrial fibrillation, and peripheral vascular disease. Adjusted analyses demonstrated no increased risk of in‐hospital mortality (2.3% vs. 3.4%; adjusted odds ratio [aOR] 0.65, 95% confidence interval [CI] 0.41–1.18, p = 0.29) or major complications, including cardiac arrest, pericardial complications, vascular injury, pulmonary complications, or embolic events. Similarly, (3.6% vs. 5.3%; aOR 0.76, 95% CI 0.48–1.43, p = 0.35) and 30‐day all‐cause readmissions (8.7% vs. 9.1%; aOR 0.81, 95% CI 0.64–1.28, p = 0.70) were not significantly different between groups. Subgroup analyses by indication for TLR (infection vs. mechanical complication) revealed no differences in outcomes. Conclusion Despite theoretical concerns, prior mediastinal radiation was not associated with excess procedural risk or worse short‐term outcomes after TLR. These findings may inform procedural planning and risk counseling in clinical practice.
Catheter Ablation in Atrial Fibrillation and Obstructive Sleep Apnea: From Rhythm Control to Risk Reduction
Deshmukh, Abhishek , DeSimone, Christopher V. , Agarwal, Siddharth , Deshmukh, Abhishek J , DeSimone, Christopher V , Agarwal, Siddharth , Agarwal, Siddharth

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 6, 2025 | Volume: 37 | Issue: 1 | Pages: 46-48

10.1111/jce.70177 | PMID 41194379 Get It

Impact of Timing of Atrial Fibrillation Ablation on AF Recurrence and Clinical Outcomes in Patients With HFpEF and HFrEF
Eisa, Mahmoud , Elbenawi, Hossam , Iftikhar, Momina, Shaer, Ahmed El , Eltony, Muhammad , Almaadawy, Omar , Aglan, Amro , Mohamed, Kareem A., Shadi, Mahmoud , Rao, Ch. Mohan , Lee, Justin Z. , Munoz, Freddy Del‐Carpio , Siontis, Konstantinos C. , Deshmukh, Abhishek , Del-Carpio Munoz, Freddy , Siontis, Konstantinos C , Link, Mark S. , Deshmukh, Abhishek J , DeSimone, Christopher V , Ahmed, Mahmoud , Mohamed, Kareem A., Elfert, Khaled , Rao, Mohan, Asad, Zain Ul Abideen , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | November 5, 2025 | Volume: 37 | Issue: 1 | Pages: 26-35

10.1111/jce.70166 | PMID 41189307 Get It

ABSTRACT Background Early catheter ablation for atrial fibrillation (AF) improves outcomes, but the optimal timing, especially in heart failure (HF) subtypes, remains unclear. Objective To evaluate the impact of ablation timing on outcomes in patients with HF with reduced ejection fraction (HFrEF) and HF with preserved ejection fraction (HFpEF). Methods We used the TriNetX database (2010–2024) to identify HF patients with AF who underwent ablation. Patients were classified as early ablation (≤ 1 year of first AF diagnosis) or delayed ablation (1–3 years), with propensity score matching (PSM) applied to balance the baseline characteristics. The primary outcome was AF recurrence, defined by repeat ablation, direct current cardioversion (DCCV), or antiarrhythmic drug (AAD) use after a 3‐month blanking period. Secondary outcomes included stroke, hospitalization, and mortality over 5 years. Results After PSM, delayed ablation was associated with higher AF recurrence in both HFrEF (HR = 1.28, p < 0.001) and HFpEF (HR = 1.21, p = 0.02), as seen in multivariate analysis. In HFrEF, delayed ablation was associated with higher incidence of re‐do ablation, AAD use, and DCCV, while in HFpEF, higher recurrence with delayed ablation was associated with increased AAD use. Both cohorts had similar stroke and mortality rates between early and delayed ablation. Conclusions Delayed ablation in HFrEF and HFpEF was linked to higher AF recurrence, driven by increased redo ablations, DCCV, AAD use in HFrEF, and higher AAD use in HFpEF. Stroke, HF hospitalization and mortality rates were similar, suggesting earlier ablation may enhance rhythm control over other outcomes.
Abstract 4361481: Catheter Ablation for Ventricular Tachycardia in Ischemic Cardiomyopathy: A Meta-Analysis with Reconstructed Time-to-Event and Trial Sequential Analysis
Elbenawi, Hossam , Elsalmouny, Youmna, Mohamed, Kareem , Wagdy, Mohamed, Hamed, Belal, Thakurathi, Priyesh , Kalaiger, Abdul M., Ibrahim, Ahmed M. , Eisa, Mahmoud , Ibrahim, Ramzi , Zaaya, Morad, Almaadawy, Omar , Quelal, Karol , Lee, Justin Z. , Siontis, Konstantinos C. , Munoz, Freddy Del‐Carpio , DeSimone, Christopher P., Deshmukh, Abhishek , Agarwal, Siddharth , Agarwal, Siddharth , Hashim, Ahmed , Agarwal, Siddharth, Wagdy, Mohamed , Hamed, Belal, Al‐Shammari, Ali Saad , Ibrahim, Ramzi , Tan, Min Choon , Asad, Zain Ul Abideen , Desimone, Christopher, Deshmukh, Abhishek

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4361481 Get It

Background: Ventricular tachycardia (VT) is a major contributor to death among ischemic heart disease (IHD) patients. In this systematic review and meta-analysis, we evaluate the efficacy of catheter ablation in patients with ischemic cardiomyopathy. Methods: We conducted a meta-analysis by searching the electronic database up to April 2025. Seven studies, including 1192 patients, were identified. A random-effect model was used to estimate pooled risk ratios (RRs) and 95% confidence intervals (CIs). Trial sequential analysis was conducted to assess sample size adequacy. Results: Among Ischemic heart disease patients with ICDs, VT ablation was associated with a significant reduction in ICD shocks (RR = 0.50, 95% CI [0.34–0.74]), a trend toward reduced VT storm (RR = 0.64, 95% CI [0.40–1.04], p = 0.07), and lower rates of cardiovascular hospitalization (RR = 0.73, 95% CI [0.53–1.01], p = 0.06) compared to ICD alone. However, no significant differences were observed when compared to patients receiving ICD plus antiarrhythmic drugs (AADs). Additionally, VT ablation showed no significant impact on mortality or VT/VF recurrence compared to either ICD alone or ICD with AADs. Trial Sequential Analysis provided conclusive evidence for VT/VF recurrence outcomes, while further data are required for other outcomes. Conclusion: Among ischemic heart disease patients with ICD, VT ablation reduces ICD shocks, VT storm, and cardiovascular hospitalizations compared to ICD-only, but offers no significant advantage over ICD combined with antiarrhythmic drugs. VT ablation does not impact mortality or the recurrence of VT/VF. Trial Sequential Analysis confirmed conclusive evidence for VT/VF recurrence, while additional data is needed for other outcomes.
Abstract 4359102: Trends in Incidence of Atrial Fibrillation in the Midwest USA from 2013 to 2023
Salama, Peter, Tordsen, Walker, Manemann, Sheila M., Killian, Jill M. , Vaughan, Lisa E. , Siontis, Konstantinos C. , DeSimone, Christopher P., Deshmukh, Abhishek , Salama, Peter, Gersh, Bernard J. , Noseworthy, Peter A. , Desimone, Christopher, Chamberlain, Alanna M.

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4359102 Get It

Background: Atrial fibrillation (AF) is the most common sustained arrhythmia with prevalence increasing over the last decade. However, data on recent temporal trends in incidence of AF have been inconsistent, with some reports of increasing trends over time and others indicating no change in incidence over time. Therefore, we aimed to determine how the incidence of AF has changed over the last decade in a community in the Midwest USA. Methods: Between 2013 and 2023, adults (aged 18 and older) with incident AF were identified in a 27-county region in the Midwest. AF was identified using diagnostic codes by employing an electronic algorithm requiring 1 inpatient code or 2 outpatient codes separated by >7 days but within 1 year. For total rates, age - and sex-adjusted incidence rates were standardized to the 2010 US total population. Poisson regression was used to calculate the incidence rate ratio of AF for 2023 vs 2013. Results: We identified 44,930 individuals with incident AF from 2013 to 2023. Of these, 56.4% were male, the mean (SD) age was 72.8 (13.5) years, and 95.8% were non-Hispanic white. The age-and sex-adjusted incidence rates (per 1,000) and 95% confidence intervals standardized to the 2010 US total population were 5.24 (5.07-5.41) in 2013, 5.73 (5.56-5.91) in 2018, and 5.44 (5.28-5.61) in 2023. Although a drop in incidence was observed corresponding to the COVID-19 pandemic, a small increase in the overall incidence of AF was observed over time. The overall incidence rate ratio (95% CI) for 2023 vs 2013 was 1.07 (1.02-1.11), P=0.003. The incidence rates were higher in men compared to women and increased with older age ( Figure 1 ). However, differences in AF incidence by sex were greatest in the youngest age group and attenuated with older age (incidence rate ratio (95% CI): 2.18 (2.10-2.28) for ages 18-64 years, 1.76 (1.70-1.83) for ages 65-74 years, 1.38 (1.33-1.42) for ages 75-84 years, and 1.23 (1.18-1.28) for ages 85 years and older). Conclusion: In this 27-county region in the Midwest, although small in magnitude, a statistically significant increase in AF incidence was observed over time from 2013 to 2023. Furthermore, the incidence of AF was higher in men compared with women, especially in younger age groups.
Abstract 4365146: Impact of Timing of Atrial Fibrillation Ablation on Outcomes in Patients with HFpEF and HFrEF
Eisa, Mahmoud , Elbenawi, Hossam , Iftikhar, Momina, El-Shaer, Ahmed Nagah, Almaadawy, Omar , Eltony, Muhammad , Aglan, Amro , Mohamed, Kareem, Shadi, Mahmoud , Rao, Ch. Mohan , Munoz, Freddy Del‐Carpio , Siontis, Konstantinos, Deshmukh, Abhishek , ElShaer, Ahmed, Ahmed, Mahmoud , Elfert, Khaled , Rao, Mohan, Lee, Justin , Asad, Zain Ul Abideen , Link, Mark S. , DeSimone, Christopher V.

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4365146 Get It

Background: Early catheter ablation for atrial fibrillation (AF) improves outcomes, but the optimal timing, especially in heart failure (HF) subtypes, remains unclear. Objective: To evaluate the impact of ablation timing on outcomes in patients with HF with reduced ejection fraction (HFrEF) and HF with preserved ejection fraction (HFpEF). Methods: We used the TriNetX database (2010–2024) to identify HF patients with AF who underwent ablation. Patients were classified as early ablation (≤1 year of first AF diagnosis) or delayed ablation (1–3 years), with propensity score matching (PSM) applied to balance the baseline characteristics. The primary outcome was AF recurrence, defined by repeat ablation, direct current cardioversion (DCCV), or antiarrhythmic drug (AAD) use after a 3-month blanking period. Secondary outcomes included stroke, hospitalization, and mortality over 5 years. Results: After PSM, delayed ablation was associated with higher AF recurrence in both HFrEF (HR 1.25, p < 0.001) and HFpEF (HR 1.27, p = 0.01), as seen in multivariate analysis. In HFrEF, delayed ablation was associated with higher incidence of re-do ablation, AAD use, and DCCV, while in HFpEF, higher recurrence with delayed ablation was associated with increased AAD use. Both cohorts had similar stroke and mortality rates between early and delayed ablation. Conclusions: Delayed ablation in HFrEF and HFpEF was linked to higher AF recurrence, driven by increased redo ablations, DCCV, AAD use in HFrEF, and higher AAD use in HFpEF. Stroke and mortality rates were similar, suggesting earlier ablation may enhance rhythm control without affecting long-term survival.
Abstract 4361539: Long-term Outcomes of Leadless versus Transvenous Single-chamber Pacemaker in Elderly Patients
Sin, Yuh Miin, Singh, Ravnit, Deshmukh, Abhishek , Sroubek, Jakub , Wazni, Oussama M. , Lee, Justin Z. , Tan, Min Choon , Vignarajah, Aravinthan , Sin, Yuh Miin, DeSimone, Christopher V. , Santangeli, Pasquale

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4361539 Get It

Background: Leadless pacemaker has emerged as a promising alternative to traditional transvenous pacemaker (PM) among elderly patients who are at high risk of complications. Objective: This study aims to assess and compare 5-year clinical outcomes of leadless PM versus transvenous single-chamber PM in elderly patients using a multi-national dataset. Methods: Using the TriNetX Analytics Research Network, we included patients aged ≥65 years who underwent leadless versus transvenous single-chamber PM implantation between 1/1/2014 and 1/1/2020. Propensity score matching (PSM) was performed by using patient’s demographic, LVEF, cardiac comorbidities, and medications. The study outcomes included all-cause mortality and adverse cardiovascular events over a 5-year follow-up period. Results: After PSM, 7,501 patients in each group were analyzed. Leadless PM was associated with a significantly lower odds of 5-year all-cause mortality (odds ratio [OR]: 0.534; 95% confidence interval [CI]: 0.497-0.575), heart failure exacerbation (OR: 0.779, 95% CI: 0.721-0.841), major bleeding (OR: 0.666, 95% CI: 0.604-0.734), cardiac arrest (OR: 0.747, 95% CI: 0.646-0.864) and stroke (OR: 0.825, 95% CI: 0.750-0.908) compared to transvenous single-chamber PM. No significant difference was observed between the two groups in all-cause hospitalization (OR: 1.006, 95%CI: 0.938-1.079), cardiac thrombus (OR: 1.077, 95%CI: 0.791-1.465) or venous thromboembolism (OR: 1.028, 95%CI: 0.916-1.153). Conclusion: Leadless PM was associated with significantly improved mortality and cardiovascular outcomes compared to transvenous single-chamber PM in elderly patients. These findings support the strong consideration of leadless pacing as a strategy to reduce mortality and improve clinical outcomes in this high-risk population.
Efficacy and Safety of PolarX for Pulmonary Vein Isolation in Atrial Fibrillation: A Systematic Review and Meta‐Analysis
Erzinger, Gabriel , Streit, Rafael Eduardo , Luiz, Laura , Rajith, Gokul , Torres, Matheus Hariel Colin, Braga, Marcelo Antonio Pinheiro , Deshmukh, Abhishek , Silva, Lívia Teixeira Martins e , Ferreira Félix, Iuri, Silva, Livia Teixeira Martins , Luiz, Laura, Rivera, André , Torres, Matheus Hariel Colin, Félix, Iuri Ferreira , DeSimone, Christopher V.

Mayo Clinic

Pacing and Clinical Electrophysiology | October 17, 2025 | Volume: 48 | Issue: 11 | Pages: 1234-1243

10.1111/pace.70070 | PMID 41105686 Get It

ABSTRACT Background The efficacy and safety of PolarX cryoballoon for pulmonary vein isolation (PVI) among patients with atrial fibrillation (AF) is unclear. Methods PubMed, Embase, Cochrane Central, and ClinicalTrials.gov were systematically searched for studies comparing the PolarX vs. standard cryoballoon (CB‐2/CB‐4). Odds ratios (ORs) and mean differences (MDs) with 95% confidence intervals (95% CIs) were computed for binary and continuous outcomes, respectively. Results This systematic review and meta‐analysis included 2 randomized controlled trials and 18 observational studies with a total of 7107 patients, of whom 3.188 (44.8%) underwent ablation with PolarX. When compared to standard cryoablation, PolarX had similar incidence of atrial arrhythmias recurrence (OR 1.04; 95% CI 0.82–1.32; p = 0.73), acute PVI success (OR 0.91; 95% CI 0.31–2.68; p = 0.98), and procedural duration (MD 3.41; 95% CI ‐2.89 to 9.71; p = 0.29). However, PolarX was associated with higher persistent phrenic nerve palsy (OR 2.17; 95% CI 1.26–3.74; p = 0.005) and a lower nadir temperature in all veins. Additionally, in a subgroup analysis of randomized trials and propensity score matching studies, similar findings were noted for recurrence of atrial arrhythmias. Conclusion In patients with AF undergoing PVI, PolarX had similar acute PVI success, procedural duration, and recurrence of atrial arrhythmias as compared with standard cryoballoon technology, however, was associated with a lower nadir temperature, and higher rates of persistent nerve palsy.