Citations

Showing 10 of 108036 citations.

Pooled Genetic Screenings to Identify Likely Pathogenic Variants in Hypertrophic Cardiomyopathy
Georges, Adrien , Chahal, C. Anwar A. , Chahal, Choudhary Anwar A

Mayo Clinic

Circulation: Genomic and Precision Medicine | March 18, 2024 | Volume: 17 | Issue: 2 | Pages: No page available

10.1161/circgen.124.004599 | PMID 38497213 Get It

The Efficacy of a Multimodal Bedroom-Based ‘Smart’ Alarm System on Mitigating the Effects of Sleep Inertia
Campanella, Carolina , Byun, Kunjoon , Senerat, Araliya , Li, Linhao , Zhang, Rongpeng , Aristizabal, Sara , Porter, Paige , Bauer, Brent A. , Bauer, Brent A , Porter, Paige

Mayo Clinic

Clocks & Sleep | March 18, 2024 | Volume: 6 | Issue: 1 | Pages: 183-199

10.3390/clockssleep6010013 | PMID 38534801 Get It

Previous work has demonstrated the modest impact of environmental interventions that manipulate lighting, sound, or temperature on sleep inertia symptoms. The current study sought to expand on previous work and measure the impact of a multimodal intervention that collectively manipulated light, sound, and ambient temperature on sleep inertia. Participants slept in the lab for four nights and were awoken each morning by either a traditional alarm clock or the multimodal intervention. Feelings of sleep inertia were measured each morning through Psychomotor Vigilance Test (PVT) assessments and ratings of sleepiness and mood at five time-points. While there was little overall impact of the intervention, the participant’s chronotype and the length of the lighting exposure on intervention mornings both influenced sleep inertia symptoms. Moderate evening types who received a shorter lighting exposure (≤15 min) demonstrated more lapses relative to the control condition, whereas intermediate types exhibited a better response speed and fewer lapses. Conversely, moderate evening types who experienced a longer light exposure (>15 min) during the intervention exhibited fewer false alarms over time. The results suggest that the length of the environmental intervention may play a role in mitigating feelings of sleep inertia, particularly for groups who might exhibit stronger feelings of sleep inertia, including evening types.
How We Treat Primary Hyperoxaluria Type 1
Breeggemann, Matthew C. , Harris, Peter C. , Lieske, John C. , Tasian, Gregory E. , Wood, Kyle D. , Harris, Peter C , Lieske, John C , Tasian, Greg

Mayo Clinic

Clinical Journal of the American Society of Nephrology | March 18, 2024 | Volume: 19 | Issue: 6 | Pages: 800-802

10.2215/cjn.0000000000000460 | PMID 38494457 Get It

Ultrasound-Based Noncontrast Microvascular Imaging for Evaluation of Breast Lesions: Imaging Techniques and Review of Diagnostic Criteria
Mohindra, Namita , Soni, Neetu

Mayo Clinic

Indian Journal of Radiology and Imaging | March 17, 2024 | Volume: 34 | Issue: 04 | Pages: 702-713

10.1055/s-0044-1782162 | PMID 39318571 Get It

AbstractVascularity plays a pivotal role in the progression of breast lesions and may be associated with their aggressiveness and likelihood of being malignant. Contrast-enhanced imaging techniques are necessary to evaluate vascularity due to the limited sensitivity of conventional color Doppler techniques, in which motion artifacts are eliminated using wall filters. However, in this process, low-flow signals from small vessels also get removed unintentionally. Advancements in technology have revolutionized the way ultrasound images are generated, resulting in tremendous improvements in Doppler imaging techniques. The new, ultrasound-based noncontrast microvascular imaging techniques overcome the limitations of conventional Doppler, and are highly sensitive for detecting microvessels and low flow. The resultant high Doppler sensitivity leads to detection of vascularity in more breast lesions. It is important for radiologists to understand the imaging principles and the clinical implications of the new techniques, to optimally utilize them and aid correct diagnosis. Angio-PLUS is one such recent advancement, which uses unfocused or plane waves and three-dimensional wall filtering to analyze tissue motion in time, space, and amplitude domains that effectively distinguish between blood flow and tissue. The information is beneficial for assessing the lesion vascularity without using contrast. This article aims to explain the Doppler imaging techniques, their clinical applications, scanning methods, and review the common Doppler-based diagnostic criteria used in the evaluation of breast lesions.
Testing for SARS-CoV-2: lessons learned and current use cases
Theel, Elitza S. , Kirby, James E. , Pollock, Nira R.

Mayo Clinic

Clinical Microbiology Reviews | March 17, 2024 | Volume: 37 | Issue: 2 | Pages: No page available

10.1128/cmr.00072-23 | PMID 38488364 Get It

SUMMARY The emergence and worldwide dissemination of SARS-CoV-2 required both urgent development of new diagnostic tests and expansion of diagnostic testing capacity on an unprecedented scale. The rapid evolution of technologies that allowed testing to move out of traditional laboratories and into point-of-care testing centers and the home transformed the diagnostic landscape. Four years later, with the end of the formal public health emergency but continued global circulation of the virus, it is important to take a fresh look at available SARS-CoV-2 testing technologies and consider how they should be used going forward. This review considers current use case scenarios for SARS-CoV-2 antigen, nucleic acid amplification, and immunologic tests, incorporating the latest evidence for analytical/clinical performance characteristics and advantages/limitations for each test type to inform current debates about how tests should or should not be used.
Identification of the novel HLA‐DQA1*05:101 allele by next‐generation sequencing in a family
Du, Zeying , Murrin, Michelle E., Patel, Pritesh B., Williams, C. D. H., Elrefaei, Mohamed , Williams, Charles D, Du, Zeying , Williams, Charles D.

Mayo Clinic

HLA | March 16, 2024 | Volume: 103 | Issue: 3 | Pages: No page available

10.1111/tan.15443 | PMID 38488750 Get It

HLA‐DQA1*05:101 differs from HLA‐DQA1*05:01:01:02 by one nucleotide substitution at codon 221 (CGT>TGT) in exon 4.
Managing blood product shortages: Unprecedented challenges require novel solutions
Jacobs, Jeremy W. , Raza, Sheharyar , Woo, Jennifer S. , Woo, Jennifer S , Jacobs, Jeremy W

Mayo Clinic

Transfusion | March 16, 2024 | Volume: 64 | Issue: 3 | Pages: 565-566

10.1111/trf.17723 | PMID 38488299 Get It

Clinical validation of the VIPUN™ gastric monitoring system versus manometry for the evaluation of gastric motility
Raymenants, Karlien , Huang, I‐Hsuan , Tichelen, Nico Van, Burton, Duane D. , Tack, Jan , Burton, Duane, Tack, Jan , Goelen, Nick , Janssen, Pieter

Mayo Clinic

Neurogastroenterology & Motility | March 16, 2024 | Volume: 36 | Issue: 6 | Pages: No page available

10.1111/nmo.14783 | PMID 38488253 Get It

AbstractBackgroundGastrointestinal dysmotility is frequently suspected in patients with gastroparesis, functional dyspepsia, and ileus, and in the intensive care unit. Monitoring of gastric motility in clinical practice remains challenging. A novel technology was developed to meet the medical need for a widely available bedside tool to monitor gastric motility continuously. The VIPUN™ Gastric Monitoring System (GMS) comprises a nasogastric feeding tube with intragastric balloon to allow for measuring gastric contractions.AimsTo compare the performance of the VIPUN GMS versus a reference technique (manometry).MethodsIn this validation study in healthy subjects, the investigational catheter and a solid‐state manometry catheter were placed in the stomach concomitantly. Motility was recorded for 2.5 h: 2 h in a fasting state, followed by a 400‐kcal liquid meal, and monitoring of the fed state for the remaining half hour. The performance of both systems was compared by automated recognition and manual identification of the contractile activity. Data are presented as mean (standard deviation).Key ResultsThe analysis set comprised 13 healthy subjects (6 women, age: 27.5 (8.1) years, BMI: 22.2 (2.46) kg/m2). Automatically‐recognized contractility was strongly correlated between the two techniques (endpoint: contraction duration; Spearman ρ = 0.96, p < 0.001). A correlation was also observed between the number of individual contractions identified by expert gastroenterologists on both technologies independently (ρ = 0.71, p = .007) and between the contractions identified by the experts and by the GMS software (ρ = 0.87, p = 0.001). No serious or unanticipated adverse events occurred.Conclusions & InferencesThe observed strong correlations with the gold standard, manometry, validate the performance of the VIPUN GMS as a gastric monitoring system.
Long‐term outcomes with abandoning versus extracting sterile leads: A 10‐year population‐based study
Lee, Justin Z. , Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Asirvatham, Samuel J. , Kusumoto, Fred , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Valverde, Arturo, Asirvatham, Samuel J , Kusumoto, Fred M , Cha, Yong-Mei , Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | March 16, 2024 | Volume: 47 | Issue: 5 | Pages: 626-634

10.1111/pace.14940 | PMID 38488756 Get It

Abstract Background Long‐term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. Methods We performed a retrospective study of a population residing in southeastern Minnesota with follow‐up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow‐up for at least 10 years or until their death were included. Results A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% ( n = 14) of patients with initial LA and 5.3% ( n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10‐year survival probability among the LA group and the TLE group ( p = .64). Conclusion An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10‐year survival probability between both lead management approaches.
Clinical evaluation of a stereotactic system for single-stage deep brain stimulation surgery under general anesthesia: technical note
Scheitler, Kristen M. , Rusheen, Aaron E. , Goyal, Abhinav , Hong, Sukwoo , Osman, Gamaleldin , Sharaf, Basel , Klassen, Bryan T. , Miller, Kai J. , Shin, Hojin , Lee, Kendall H. , Sharaf, Basel A , Yuen, Jason , Grewal, Sanjeet S. , Oh, Yoonbae

Mayo Clinic

Journal of Neurosurgery | March 16, 2024 | Volume: 141 | Issue: 2 | Pages: 406-411

10.3171/2024.1.jns232563 | PMID 38489816 Get It

OBJECTIVE Conventional frame-based stereotactic systems have circumferential base frames, often necessitating deep brain stimulation (DBS) surgery in two stages: intracranial electrode insertion followed by surgical re-preparation and pulse generator implantation. Some patients do not tolerate awake surgery, underscoring the need for a safe alternative for asleep DBS surgery. A frame-based stereotactic system with a skull-mounted "key" in lieu of a circumferential base frame received US FDA clearance. The authors describe the system’s application for single-stage, asleep DBS surgery in 8 patients at their institution and review its workflow and technical considerations. METHODS Eight patients underwent DBS lead insertion and IPG implantation in a single surgical preparation under general anesthesia using the system. Postoperative CT imaging confirmed lead placement. RESULTS Eight patients underwent implantation of 15 total leads targeting the ventral intermediate nucleus (4 patients), globus pallidus internus (GPi; 3 patients), and subthalamic nucleus (STN; 1 patient). Intraoperative microelectrode recording was conducted for GPi and STN targets. Postoperative CT imaging revealed a mean ± SD radial error of 1.24 ± 0.45 mm (n = 15 leads), without surgical complications. CONCLUSIONS The stereotactic system facilitated safe and effective asleep, single-stage DBS surgery, maintaining traditional lead accuracy standards.