Citations

Clear

343 citation(s) found for "Asirvatham, Samuel J".

The Diagnostic Value of Cardiac Deceleration Capacity in Vasovagal Syncope
Zheng, Lihui , Sun, Wei , Liu, Shangyu , Liang, Erpeng , Du, Zhongpeng , Guo, Jingrui, Wu, Lingmin , Asirvatham, Samuel J. , Asirvatham, Samuel J , Yao, Yan

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | November 16, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.008659 | PMID 33197331 Get It

Background: Increased parasympathetic activity is thought to play important roles in syncope events of patients with vasovagal syncope (VVS). However, direct measurements of the vagal control are difficult. The novel deceleration capacity (DC) of heart rate measure has been used to characterize the vagal modulation. This study aimed to assess vagal control in patients with VVS and evaluate the diagnostic value of the DC in VVS. Methods: Altogether, 161 consecutive patients with VVS (43±15 years; 62 males) were enrolled. Tilt table test was positive in 101 and negative in 60 patients. Sixty-five healthy subjects were enrolled as controls. DC and heart rate variability in 24-hour ECG, echocardiogram, and biochemical examinations were compared between the syncope and control groups. Results: DC was significantly higher in the syncope group than in the control group (9.6±3.3 versus 6.5±2.0 ms, P <0.001). DC was similarly increased in patients with VVS with a positive and negative tilt table test (9.7±3.5 and 9.4±2.9 ms, P =0.614). In multivariable logistic regression analyses, DC was independently associated with syncope (odds ratio=1.518 [95% CI, 1.301–1.770]; P =0.0001). For the prediction of syncope, the area under curve analysis showed similar values when comparing single DC and combined DC with other risk factors ( P =0.1147). From the receiver operator characteristic curves for syncope discrimination, the optimal cutoff value for the DC was 7.12 ms. Conclusions: DC>7.5 ms may serve as a good tool to monitor cardiac vagal activity and discriminate VVS, particularly in those with negative tilt table test.
Infection Rate and Outcomes of Watchman Devices: Results from a Single Center 14-Year Experience
McGill, Trevon, Ponamgi, Shiva , Asirvatham, Samuel J. , Holmes, David , DeSimone, Christopher V. , Asirvatham, Samuel J , DeSimone, Christopher V , Ward, Robert C. , Adel, Fadi , Baddour, Larry M. , DeSimone, Daniel C.

Mayo Clinic

No container title available | October 1, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.160157615.57696419 Get It

Background: Left atrial appendage occlusion with the Watchman device is an alternative strategy for stroke risk reduction in patients with non-valvular atrial fibrillation. There are rare case reports of Watchman associated infection. Currently, there is no formal study that evaluated the incidence and outcomes of Watchman-related infections. Methods: All patients who underwent Watchman implantation over a 14 year study period (July 2004 through December 2018) comprised our cohort. Baseline characteristics, procedural data, and post-implantation events were identified. Primary study outcomes included Watchman related infection, other cardiovascular device related infection, bacteremia, and mortality. Results: A total of 181 patients with an average age of 75, and a median CHA2DS2-VASc Score of 4 (interquartile range 2) and a median HAS-BLED Score of 3 (interquartile range 1), were included for analysis. A total of 534.7 patient years of follow up was accrued with an average of 2.9 years per patient. The most common indications for implantation included gastrointestinal bleeding (56 patients; 30.9%) and intracerebral bleeding (51 patients; 28.2%). During follow up, 38 patients (21%) died. Six developed evidence of bacteremia. Only one developed an implantable cardioverter defibrillator (ICD) infection that required complete system extraction. None of the cohort developed Watchman-related device infection during the study period. Conclusion: In a single center study spanning a 14 year period, we report no Watchman-related devices infections. This is despite the presence of patients with bacteremia, as well as an ICD infection requiring extraction. These data suggest that Watchman devices are extremely unlikely to become infected.
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Kuzmenko, Volodymyr , Sämfors, Sanna, Livia, Christopher , Vaidya, Vaibhav R. , Sugrue, Alan , Behfar, Atta , Asirvatham, Samuel J. , Gatenholm, Paul , Kapa, Suraj , van Zyl, Martin , Livia, Christopher , Vaidya, Vaibhav , Sugrue, Alan , Asirvatham, Samuel J , Gatenholm, Paul , Kapa, Suraj , Behfar, Atta , Karabulut, Erdem , McLeod, Christopher J.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 | PMID 32966655 Get It

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
Trends in reported industry payments to physicians practicing cardiac electrophysiology from 2013 to 2018 in the United States
Tseng, Andrew S. , Hu, Tiffany , Lee, Justin Z. , Amin, Mustapha, Vaidya, Vaibhav R. , Deshmukh, Abhishek , Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Mulpuru, Siva K. , Hu, Tiffany Y, Vaidya, Vaibhav , Tseng, A S , Asirvatham, Samuel J

Mayo Clinic

Journal of Cardiovascular Electrophysiology | September 21, 2020 | Volume: 31 | Issue: 12 | Pages: 3106-3114

10.1111/jce.14754 | PMID 32955151 Get It

AbstractIntroductionThe need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined.Methods and ResultsPayment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in‐depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165–$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik.ConclusionAmong cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.
A novel technique—Prophylactic septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement (RADIO‐TMVR)
Killu, Ammar M. , Siontis, Konstantinos C. , Sabbagh, Abdallah El , Eleid, Mackram F. , Rihal, Charanjit S. , Asirvatham, Samuel J. , Rihal, Charanjit, Asirvatham, Samuel J , Guerrero, Mayra , Alkhouli, Mohamad , Rihal, Charanjit S.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | August 21, 2020 | Volume: 31 | Issue: 11 | Pages: 3048-3055

10.1111/jce.14720 | PMID 32820547 Get It

AbstractTranscatheter mitral valve replacement (TMVR) with off‐label use of aortic balloon‐expandable transcatheter heart valves has emerged as a therapeutic option in high‐surgical risk patients with severe mitral annular calcification. Left ventricular outflow tract (LVOT) obstruction post valve deployment is a major limitation. We describe a case of septal reduction therapy using radiofrequency ablation (RFA) when established methods of septal reduction were either ineffective or not feasible. RFA permitted successful enlargement of the LVOT area and subsequent TMVR.
Ventricular asystole in the presence of a biventricular device
Karki, Roshan , Lloyd, James W. , Mulpuru, Siva K. , Asirvatham, Samuel J. , Lloyd, James, Asirvatham, Samuel J , Lloyd, James, DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | August 12, 2020 | Volume: 31 | Issue: 11 | Pages: 3031-3035

10.1111/jce.14715 | PMID 32786037 Get It

AbstractIn pacemaker‐dependent patients with a newly implanted cardiac device, acute lead dislodgement constitutes one of the most common causes of loss of capture and ventricular asystole. In a biventricular system, it would be expected that such a potentially catastrophic event would be prevented with back‐up right ventricular pacing unless both leads dislodge.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

Mayo Clinic

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 | PMID 33094311 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.
Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Mayo Clinic

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 | PMID 32757438 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
High Mortality Rates Among Patients With Non‐Traumatic Intracerebral Hemorrhage and Atrial Fibrillation on Antithrombotic Therapy Are Independent of the Presence of Cerebral Amyloid Angiopathy: Insights From a Population‐Based Study
Ponamgi, Shiva , English, Stephen , Hodge, David O. , Slusser, Joshua P. , Graff‐Radford, Jonathan , Asirvatham, Samuel J. , Holmes, David R. , Ponamgi, Shiva P , Ward, Robert, Asirvatham, Samuel J , Ward, Robert C. , DeSimone, Christopher V. , Rabinstein, Alejandro A.

Mayo Clinic

Journal of the American Heart Association | July 25, 2020 | Volume: 9 | Issue: 15 | Pages: No page available

10.1161/jaha.120.016893 | PMID 32715895 Get It

Background Intracerebral hemorrhage (ICH) risk is higher in elderly patients with atrial fibrillation on antithrombotic therapy as well as those with cerebral amyloid angiopathy (CAA). We investigated if mortality among patients with atrial fibrillation on antithrombotic therapy presenting with non‐traumatic ICH was influenced by underlying CAA. Methods and Results We used the Rochester Epidemiology Project to identify 6045 patients with atrial fibrillation aged >55 years on anticoagulation or antiplatelet therapy from 1995 to 2016. Seventy‐four patients in this cohort presented with non‐traumatic ICH. Medical records including imaging data were reviewed to identify those with CAA and record baseline variables and outcomes of interest; 38 of our 74 patients (51.4%) (mean age 81.5 years) met Modified Boston Criteria for possible or probable CAA. Twenty‐six of 74 patients (35%) died during the first 30 days while 56 of the 74 (76%) patients died by 10 years follow‐up after index ICH. Overall mortality was not significantly different between the CAA and non‐CAA groups at any point of time during follow‐up ( P =0.89) even amongst patients restarted on anticoagulation +/− antiplatelet (n=19) ( P =0.46) or those patients restarted only on antiplatelet therapy (n=22) ( P =0.66). Three of the 41 patients who restarted on antithrombotic therapy had a recurrent ICH; these 3 patients met criteria for possible or probable CAA. Conclusions Although more than half of our patients with atrial fibrillation on antithrombotic therapy and non‐traumatic ICH met Modified Boston Criteria for CAA, CAA did not significantly influence the high mortality seen in this cohort.
Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices
Phillips, Kari A. , Ponamgi, Shiva , Mundell, Benjamin F. , Krushelnytskyy, Mykhaylo , Li, Zhuo , Rea, Robert F., Deshmukh, Abhishek , Espinosa, Raúl E. , Osborn, Michael J., Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Neutzling, Lori B., Munger, Thomas M. , Kancharla, Krishna , Asirvatham, Samuel J. , Mundell, Benjamin, Rea, Robert, Osborn, Michael , Friedman, Paul A , Mulpuru, Siva K , Cha, Yong-Mei , Munger, Thomas, Asirvatham, Samuel J , McLeod, Christopher J.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 16, 2020 | Volume: 31 | Issue: 10 | Pages: 2704-2710

10.1111/jce.14677 | PMID 32671902 Get It

AbstractObjectiveThis study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF).BackgroundDual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious.MethodsA retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline).ResultsIn Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes (p < .0001). Similar results were noted in Comparisons 2 and 3 (p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes (p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes.ConclusionsSetting changes at ERI including a change from dual‐ to single‐chamber pacing and/or loss of RR results in a significantly increased symptom burden and increased healthcare utilization.