Background: Inflammation is integral in the pathogenesis and propagation of atrial fibrillation (AF). Peri-ablation administration of steroids has been shown to significantly reduce AF recurrence at 3 months. We sought to determine the effect of intraoperative dexamethasone on early recurrence at both 3 months and 12 months post-ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction
Circulation: Arrhythmia and Electrophysiology | September 8, 2022 | Volume: 15 | Issue: 9 | Pages: No page available
Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
Single-Dose Intraoperative Steroid Administration Does Not Impact Early Atrial Fibrillation Recurrence
No container title available | July 26, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available
Abstract Purpose: To evaluate the effect of single-dose intravenous dexamethasone on AF recurrence following radiofrequency catheter ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience
Journal of Cardiovascular Electrophysiology | October 15, 2020 | Volume: 31 | Issue: 12 | Pages: 3277-3285
AbstractBackgroundThe leadless Micra transcatheter‐pacing system (Micra‐TPS) is implanted via a femoral approach using a 27‐French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters.ObjectiveTo examine the feasibility and safety of Micra‐TPS implantation through an IVC filter.MethodsThis multicenter retrospective study included patients with an IVC filter who underwent a Micra‐TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated.ResultsOf the 1528 Micra‐TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27‐Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6‐month follow‐up, there were no clinical complications related to the filter or the Micra‐TPS.ConclusionThis multicenter experience demonstrates the feasibility and safety of Micra‐TPS implantation via an IVC filter without acute procedural or delayed clinical complications.
Ventricular asystole in the presence of a biventricular device
Journal of Cardiovascular Electrophysiology | August 12, 2020 | Volume: 31 | Issue: 11 | Pages: 3031-3035
AbstractIn pacemaker‐dependent patients with a newly implanted cardiac device, acute lead dislodgement constitutes one of the most common causes of loss of capture and ventricular asystole. In a biventricular system, it would be expected that such a potentially catastrophic event would be prevented with back‐up right ventricular pacing unless both leads dislodge.
The circuit for bundle‐branch re‐entrant tachycardia
Journal of Cardiovascular Electrophysiology | February 20, 2020 | Volume: 31 | Issue: 4 | Pages: 972-974