Citations

Showing 10 of 107961 citations.

Inequities in ‘failure to rescue’ for Indigenous Māori after gastrointestinal cancer surgery in New Zealand
Wells, Cameron I. , Wehipeihana, Emma, Varghese, Chris , Paterson, Luke , O’Grady, Gregory , Harmston, Christopher , Bissett, Ian , O'Grady, Gregory , Gurney, Jason , Bissett, Ian , Varghese, Chris , Wells, Cameron , Koea, Jonathan

Mayo Clinic

British Journal of Surgery | July 14, 2025 | Volume: 112 | Issue: 8 | Pages: No page available

10.1093/bjs/znaf161 | PMID 40820525 Get It

Abstract Background Indigenous populations worldwide experience unjust inequities in surgical outcomes. In Aotearoa New Zealand, Indigenous Māori experience poorer health outcomes, including higher rates of postoperative mortality. The aim of this study was to quantify ethnic disparities in ‘failure to rescue’ (FTR), complications, and mortality following gastrointestinal cancer surgery and to analyse trends over time. Methods A retrospective national population-based cohort study of patients undergoing resection for gastrointestinal and hepatopancreatobiliary cancers from 2005 to 2020 was conducted. Self-reported ethnicity data were collected at the time of surgery. The primary outcome was FTR, defined as mortality following a complication within 90 days of surgery. Results In total, 31 185 patients were included; 2479 (7.9%) were Māori, 46.5% were female, and the median age was 71 (interquartile range 62–78) years. Māori patients were younger and had higher levels of socio-economic deprivation and co-morbidity. Māori had higher age-standardized rates of mortality (5.9% versus 3.2%), complications (52.9% versus 42.4%), and FTR (10.8% versus 7.2%), compared with European/Other. Multivariable regression demonstrated higher odds of mortality (adjusted OR (aOR) 1.45 (95% c.i. 1.15–1.82)), complications (aOR 1.30 (95% c.i. 1.17–1.45)), and FTR (aOR 1.29 (95% c.i. 1.01–1.62)) for Māori. Analysis over time showed a significant improvement in risk-adjusted rates of mortality (6.2% in 2005–2008 versus 3.4% in 2017–2020) and FTR (7.3% in 2005–2008 versus 4.0% in 2017–2020) for European/Other, but no change for Māori (rates of mortality were 6.6% in 2005–2008 versus 5.4% in 2017–2020 and rates of FTR were 7.8% in 2005–2008 versus 6.3% in 2017–2020). Conclusion Widening inequities in FTR have worsened disparities in postoperative mortality for Māori patients. ‘Complication rescue’ is a target to reduce inequities and improve perioperative care for Māori patients.
Sequence variability of BamA and FadL candidate vaccinogens suggests divergent evolutionary paths of Treponema pallidum outer membrane proteins
Bettin, Everton B. , Aghakhanian, Farhang , Hennelly, Christopher M. , Chen, Wentao , Davenport, Timothy C. , Hackl, Simon T. , Grassmann, André Alex , Vargas-Cely, Fabio Samir , Silva, Sebastián , Luna, Jonny Alejandro García , Jiang, Yinbo , Yang, Ligang , Zheng, Heping , Pospíšilová, Petra , Šmajs, David , Matoga, Mitch , Hoffman, Irving , Moody, M. Anthony , Salazar, Juan C. , Radolf, Justin D. , Vargas-Cely, Fabio, Šmajs, David , Caimano, Melissa J , Hawley, Kelly L , Radolf, Justin D , Ramirez, Lady Giovanna , Yang, Bin , López‐Medina, Eduardo , Nieselt, Kay , Seña, Arlene C. , Parr, Jonathan B.

Mayo Clinic

Journal of Bacteriology | July 14, 2025 | Volume: 207 | Issue: 8 | Pages: No page available

10.1128/jb.00159-25 | PMID 40802283 Get It

ABSTRACT Knowledge of Treponema pallidum subspecies pallidum ( TPA ) outer membrane protein (OMP) sequence variability is essential for understanding spirochete proliferation within endemic populations as well as the design of a globally effective syphilis vaccine. Our group has identified extracellular loops (ECLs) of TPA BamA (TP0326) and members of the FadL family (TP0548, TP0856, TP0858, TP0859, and TP0865) as potential components of a multivalent vaccine cocktail. As part of a consortium to explore TPA strain diversity, we mapped the variability of BamA and FadL orthologs in 186 TPA strains from Malawi, China, and Colombia onto predicted 3D structures. The 186 genomes fell into eight subclades (five Nichols- and three SS14-lineage) with substantial geographic restriction. Single nucleotide variants accounted for the large majority of proteoforms, with variability notably higher within the Nichols-lineage strains. Most mutations were in regions of the proteins predicted to be extracellular and harboring B cell epitopes. We observed a striking difference in the degree of variability between the six OMPs, suggesting that these proteins are following divergent evolutionary paths. Concatenation of OMP sequences recapitulated the phylogenetic structure of the TPA strains, effectively segregating within clades and largely clustering by subclades. Finally, we noted that BamA and FadL candidate ECL vaccinogens, previously shown to elicit antibodies that kill treponemes during in vitro cultivation, are well conserved. Taken as a whole, our study establishes a structural-phylogenetic approach for analyzing the forces shaping the host-pathogen interface in syphilis within endemic populations while informing the selection of vaccine targets. IMPORTANCE Syphilis remains a major global health concern, reinforcing the need for a safe and effective vaccine. Understanding the variability of TPA OMPs is essential for tracking pathogen evolution and informing vaccine design. Here, we analyzed the variability of six TPA OMPs in 186 strains from Malawi, China, and Colombia, identifying protein-specific evolutionary patterns. Most mutations were localized in extracellular regions and, notably, appeared to correlate with the phylogenetic structure of TPA . Despite OMP heterogeneity, several candidate vaccinogens remained highly conserved, reinforcing their potential as globally effective vaccine targets. Our study establishes a structural-phylogenetic framework for dissecting the forces shaping the host-spirochete interface within endemic populations and provides a foundation for designing a globally effective syphilis vaccine.
Cost-Effectiveness Analysis of Mepitel Film for Prevention of Acute Radiation Dermatitis in Breast Cancer: a Canadian Healthcare Perspective
Tse, Shirley S.W., Wong, Henry C.Y., Charbonneau, Flay, Cao, Jeffrey , Waddle, Mark R. , Wolf, Julie Ryan , Corbin, Kimberly S. , Wong, Cindy, BNurs, Raymond J Chan, Hill, Rosemary, Tse, Shirley S. W. , Wong, Henry C. Y. , Hijal, Tarek , Kerba, Marc , Lee, Shing Fung, Sonis, Stephen T. , Hurk, Corina van den, Marta, Gustavo Nader , Chan, Raymond J. , Herst, Patries M. , Chow, Edward

Mayo Clinic

No container title available | July 14, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-6865024/v1 Get It

Abstract Introduction While randomized clinical trials (RCT) confirmed superiority of Mepitel film (MF) in reducing acute radiation dermatitis (ARD) compared to standard-of-care (SoC), the incremental cost difference has limited its use. A cost-effectiveness analysis (CEA) was conducted from a Canadian healthcare payer’s perspective to guide policy decisions. Methods: A decision model was constructed to perform a CEA for MF compared to SoC (moisturisers) for prevention of grade 2 or higher ARD following adjuvant hypo-fractionated whole-breast radiotherapy (RT) based on a Canadian multicentre RCT. Direct and indirect cost data were collected from two oncology centres in Canada. Quality-of-life (QoL) utility values were derived from mapping Dermatology Life Quality Index (DLQI) scores for patients with grade 2 or higher ARD at week 6 of RT to EQ-5D. A willingness-to-pay (WTF) threshold of CAD 50,000 per quality-adjusted life years (QALY) gained was used. One-way sensitivity analysis was performed to account for uncertainty in decision model assumptions. Results: Base case analysis demonstrated that MF is cost-effective in preventing grade 2 or higher ARD as compared with SoC with an incremental cost-effectiveness ratio (ICER) of CAD 3,366 per QALY gained. When nursing costs were included, MF resulted in an ICER of CAD 2,823 per QALY gained. One-way sensitivity analysis showed that the results were most sensitive to the QoL utility value for ARD. All sensitivity variations remained well below the WTP threshold. Conclusions: MF is a cost-effective intervention for preventing high-grade ARD and should be recommended for patients with breast cancer undergoing adjuvant RT.
Enhancing proton therapy quality assurance with custom‐designed Octopoint phantom and Gafchromic film
Tang, Xueyan , Beltran, Chris , Furutani, Keith M. , Gilson, Glen, Gustafson, Jon M., Herman, Michael , Johnson, J. , Kruse, Jon J. , Long, Kenneth M., Mundy, Daniel W. , Remmes, Nicholas B. , Tasson, A , Whitaker, Todd , Matysiak, Witold, Tryggestad, E., Matysiak, W , Gilson, Graham S, Gustafson, Jon, Ito, Shima, Johnson, Jed E , Tasson, Alexandria , Whitaker, Thomas J , Tryggestad, Erik J, Beltran, Chris J , Furutani, Keith M , Matysiak, Witold P , Ito, Shima , Long, Kenneth M.

Mayo Clinic

Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70156 | PMID 40657664 Get It

Abstract Background Proton therapy offers precise tumor targeting while minimizing damage to surrounding healthy tissue, making it especially valuable for treating tumors near critical organs and in pediatric patients. However, its success depends on accurate beam delivery, requiring rigorous quality assurance (QA) to maintain treatment precision and effectiveness. Purpose This study aims to standardize the measurement of key aspects of proton therapy delivery, such as gantry and couch isocentricity, spot position accuracy, and spot size consistency. The goal is to enhance the delivery accuracy of proton therapy across various clinical settings, improving patient outcomes. Methods The QA framework uses the Octopoint phantom, Gafchromic film, and spot position monitor (SPM) log data to evaluate proton beam isocentricity, spot position, and spot size. The Octopoint phantom, made from acrylic, was used with Gafchromic films at various gantry and couch angles to measure isocentricity. MATLAB tools were used to analyze spot positions, and SPM logs provided verification. Sensitivity tests were conducted to assess the system's response to intentional shifts and errors, ensuring alignment with clinical QA standards. Results The Octopoint phantom's stepwise two‐dimensional (2D) fitting process, validated against film‐measured dose profiles, accurately identified beam and ball bearing (BB) centroid locations. Isocentricity tests conducted over 8 months across four gantries demonstrated consistent beam‐to‐BB radial offsets. The phantom showed excellent repeatability, with a maximum standard deviation of 0.1 mm across various couch‐gantry combinations. Sensitivity testing across all axes revealed a strong alignment between intended shifts and measured values. Over the course of a year, film measurements tracked spot position and size consistency, with deviations remaining within acceptable clinical limits. Comparisons with SPM data further confirmed the system's reliability in maintaining beam accuracy across different gantry angles and energy levels. Conclusions This study presents a reliable QA framework for ensuring precision in proton therapy delivery. By combining the Octopoint phantom, Gafchromic film analysis, and SPM log file evaluation, we effectively measured isocentricity, spot position accuracy, and spot size stability. The framework demonstrated adaptability across various clinical QA tasks, enhancing the accuracy and safety of proton therapy treatments.
Development of a hybrid automated chart checking, data collection, and analysis system
Clouser, Edward , Chen, Quan , Harrington, Daniel P. , Rong, Yi , Buckey, C, Clouser, Edward L, Buckey, Courtney R, Rong, Yi , Clouser, Edward Lee

Mayo Clinic

Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70161 | PMID 40657668 Get It

Abstract Purpose To describe the creation and clinical deployment of an integrated stand‐alone hybrid automated chart review platform that is comprised of a database, oncology information system (OIS) interfaces, and a user interface (UI). Methods A consensus checklist was developed to homogenize the practices of clinical physics staff and physics residents for all plan types. Critical review of the single checklist's items led to the creation of a new concept, the “plan attribute,” which permits specialization of the final checklist based on the characteristics of a particular plan. Only relevant and applicable tests are automatically populated to form a plan checklist based on plan attributes. Each populated checklist in this hybrid automation platform includes elements of full automation, steps or functions that use automation to augment a human input or effort, as well as steps completed by humans. Logging and categorizing of deficiencies found during the chart check was also implemented. Results Chart check data was analyzed for an over 4‐year time span starting from the clinical deployment of the tool in October 2020. This analysis included a total of 427 073 tests spread among 7882 initial chart checks. The recorded deficiencies at three triage levels showed 7116 minor errors, 679 major errors, and 71 plan rejections. The plan rejection level is the highest chart deficiency, which required the plan to be rejected and sent back for serious remediation and/or new plan generation. Conclusion This report describes the successful development and implementation of a hybrid‐automated chart checking program. The software leverages modern database and software design to improve the per case performance and experience of a multi‐user group. Chart check database permits high‐level review and improvement in all aspects of plan check and user performance.
Photographic Assessment of the Anatomic Localization and Extent of Hidradenitis Suppurativa: A Delphi Study
Ceresnie, Marissa S. , Jones, Brittani , Young, Albert T. , Isaq, Nasro A., Alavi, Afsáneh , Alavi, A , Sokumbi, Olayemi , Hamzavi, Iltefat H.

Mayo Clinic

Journal of Cutaneous Medicine and Surgery | July 14, 2025 | Volume: 30 | Issue: 1 | Pages: 50-55

10.1177/12034754251355183 | PMID 40654301 Get It

Background: Hidradenitis suppurativa (HS) is a chronic inflammatory disease with fluctuating activity that requires long-term visual documentation to evaluate disease severity and treatment response. A standardized protocol for photographing HS is critically needed. Objectives: To establish a standardized protocol for using photography to clinically document HS. Methods: We brought together a panel of international experts and used a modified Delphi process to reach consensus on statements about standardized practices for using photography to document HS in clinical practice and research settings. A 75% agreement level was prespecified as the cutoff for consensus. Results: Consensus for photographically documenting HS was developed within 6 key areas: patient preparation, background, lighting, size and reference scale, camera considerations, and patient positioning. The revised and optimized protocol includes 34 standardized reference illustrations. However, the proposed recommendations are for ideal scenarios, and their implementation may not always be practical in a clinical setting. Variations in resources may not have been captured. Conclusions: The proposed consensus-based protocol provides a standard for consistent photographic documentation of HS. This protocol may help clinicians provide better disease surveillance and patient care, and it may aid in more precise and reliable research and clinical trials for HS.
Cutaneous Nodules and Inflammatory Arthritis: Two Illustrative Cases of Rare Mimics of Rheumatoid Arthritis
Yaman, Reena , DiCaudo, David J. , Pham, Michael M., Griffing, W. Leroy , Sullivan, Megan M. , Aslam, Fawad , Sullivan, Megan M , Yaman, Reena N , Sokumbi, Olayemi , Pham, Michael M., Aslam, Fawad

Mayo Clinic

Journal of Clinical Medicine | July 14, 2025 | Volume: 14 | Issue: 14 | Pages: 4940

10.3390/jcm14144940 | PMID 40725633 Get It

Background: Rheumatoid arthritis is a relatively common rheumatic disease that can present with inflammatory arthritis and subcutaneous nodules. Multicentric reticulohistiocytosis and fibroblastic rheumatism are rarer entities that also present with these features. Methods: Two cases, one of each of fibroblastic rheumatism and multicentric reticulohistiocytosis, are described highlighting characteristic clinical, radiographic, and histologic findings. A narrative review of the literature on these rarer conditions, compared with rheumatoid arthritis, is provided with a focus on articular and cutaneous findings, available information on disease presentations, and key contrasting features that can aid in diagnosis. Results: Radiographic erosion distribution and joint space narrowing, clinical nodule distribution and characteristics, and nodule histology can differ between these diseases. Conclusions: Multicentric reticulohistiocytosis and fibroblastic rheumatism should be considered in the evaluation of seronegative rheumatoid arthritis, especially in cases that do not respond predictably to standard therapies, and cutaneous nodule biopsy can aid in differentiating these three conditions.
Association of Diuretic Dosage With Outcomes in Patients With Hemodynamically Significant Isolated Tricuspid Valve Regurgitation
Anand, Vidhu , Scott, Christopher G. , Ali, Khaled A., Nkomo, Vuyisile T. , Thaden, Jeremy J. , Kane, Garvan C. , Borgeson, Daniel D., Borlaug, Barry A. , Pislaru, Cristina , Eleid, Mackram F. , Ali, Khaled, Crestanello, Juan A , Pellikka, Patricia A , Sabbah, Michael S. , Nkomo, Vuyisile T , Scott, Christopher , Borlaug, Barry A , Pislaru, Cristina , Ali, Khaled, Crestanello, Juan A. , Pellikka, Patricia A. , Pislaru, Sorin V.

Mayo Clinic

Journal of the American Heart Association | July 14, 2025 | Volume: 14 | Issue: 14 | Pages: No page available

10.1161/jaha.124.039989 | PMID 40654247 Get It

Background Tricuspid valve surgery is recommended for severe isolated tricuspid regurgitation (TR) if symptoms persist despite optimal medical therapy. The definition of optimal therapy for TR is unclear beyond managing underlying conditions. Diuretics are the primary treatment for volume retention in TR, but it is unknown whether a “safe diuretic dose” exists for conservative management. We sought to evaluate the association between diuretic dose and outcomes. Methods Adult patients with ≥moderate–severe isolated TR were retrospectively identified from echocardiographic reports. Clinical and echocardiographic data were extracted from electronic medical records and manually reviewed. The primary end point was all‐cause mortality. Loop diuretic doses were converted to furosemide equivalent and categorized into 4 groups: <40 mg, 40 to 79 mg, 80 to 159 mg, and ≥160 mg daily. Results Of 1302 patients (age 72±13 years, 60% female), 565 (43%) had moderate–severe TR and 737 (57%) had severe TR. Median follow‐up was 8.7 (1.4, 14.0) years. Comorbidities increased with higher diuretic doses. A linear relationship between diuretic dose and mortality was observed in spline‐curve analysis. Hazard ratios (and CIs) for mortality adjusted for age, sex, coronary disease, chronic kidney disease, mild pulmonary hypertension, and New York Heart Association III/IV symptoms were 1.21 (0.96–1.53) ( P =0.12) for <40 mg, 1.50 (1.23–1.82) ( P <0.001) for 40 to 79 mg, 1.86 (1.46–2.37) ( P <0.001) for 80 to 159 mg, and 2.90 (2.18–3.88) ( P <0.001) for ≥160 mg furosemide equivalent. Any diuretic dose was associated with significant symptoms (New York Heart Association III–IV), with more patients experiencing symptoms at higher doses. Conclusion A daily loop diuretic dose ≥40 mg furosemide equivalent is associated with increased mortality and greater symptom severity in patients with TR.
Using geographic information system (GIS) technology to evaluate a hospital‐based mobile blood donation program
Ruby, Kristen N. , Dzik, Sunny , Collins, Julia J. , Tang, Hongying , Ela, Shawn , Makar, Robert S. , Collins, Julia , Dzik, Walter H , Ruby, Kristen N , Collins, Julia J.

Mayo Clinic

Transfusion | July 14, 2025 | Volume: 65 | Issue: 9 | Pages: 1630-1639

10.1111/trf.18332 | PMID 40654231 Get It

AbstractBackgroundGeographic information system (GIS) technology is widely used in public health to track disease patterns, though its application in transfusion medicine is limited. We report the use of GIS software by a hospital‐based blood donor program to examine patterns of blood drive activity.Study Design and MethodsWe performed a 3‐year retrospective study examining our donor program's mobile drives. Esri ArcGIS Pro™ software and ArcGIS Online™ were used to create vector and choropleth maps reflecting activity by town.ResultsSixteen thousand nine mobile whole blood donations were identified in 2021–2023. Four hundred and fifty‐five mobile blood drives were hosted at 189 unique locations. Seventeen towns within or intersecting a 15‐mile radius of our donation center had never been visited by our bloodmobile during the study period, with adult population sizes ranging from approximately 3000 to 53,000 representing donation opportunities. Untapped blood mobile opportunities were also identified in 33 Massachusetts towns (>700,000 adults) with nearby healthcare facilities in our hospital network.DiscussionGIS‐generated maps serve as an effective tool to identify previously successful blood donation locations and locations not yet visited by our donor program. Blood collection centers may benefit from future application of ArcGIS analysis tools to identify optimal locations for future mobile blood drives.
Effectiveness and Safety of Intramyocardial Needle Ablation for Refractory Ventricular Tachycardia and Premature Ventricular Complexes: A Systematic Review and Meta‐Analysis
Qureshi, Muhammad Ahmad , Rawlley, Bharat , Jain, Vardhmaan, Verma, Atul, Siontis, Konstantinos C. , Deshmukh, Abhishek , Khan, Arfaat , Gupta, Kartik , Rawlley, Bharat , Siontis, Konstantinos C , Deshmukh, Abhishek J , Jain, Vardhmaan, Verma, Atul, Raad, Mohamad

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 14, 2025 | Volume: 36 | Issue: 9 | Pages: 2279-2286

10.1111/jce.70000 | PMID 40654169 Get It

ABSTRACTIntroductionIntramyocardial needle ablation is a novel technique for treating refractory ventricular tachycardia (VT) and premature ventricular complexes (PVC). However, studies defining the effectiveness and safety of this procedure are limited. This meta‐analysis aims to evaluate the safety and effectiveness of needle ablation for VT and PVC refractory to standard ablation.MethodsEmbase, Ovid (includes Medline), and ClinicalTrials.gov were searched from inception to December 31, 2024. Human studies on needle ablation for recurrent VT and PVC were included. Primary outcome was immediate effectiveness (no immediate post‐procedural inducible VT or PVC). Secondary outcomes were long‐term effectiveness (no clinical VT or PVC at 6 months) and safety (composite measure of peri‐ and post‐procedural complications).ResultsA total of five studies including 180 patients (140 VT; 40 PVC) were analyzed. Mean ages ranged from 54 to 66 years. Among 129 patients with VT, immediate effectiveness was 75% (95% CI, 54–92; I2 80%), and cumulative freedom from clinical VT dropped to 43% at 6 months (95% CI, 35–52; I2 0%). Among 40 patients with PVC, immediate effectiveness was 82% (95% CI, 67–94; I2 0%), and long‐term effectiveness was 76% (95% CI, 61–90; I2 0%). Safety outcomes were reported in 19% of patients (95% CI, 13–27; I2 0%) and 10% of patients (95% CI 1, 23; I2 0%) in the VT and PVC arm, respectively. Death related to ablation was report in 7 patients (5.0%) only in the VT studies.ConclusionIntramyocardial needle ablation is an emerging alternative approach for refractory VT and PVC ablation, showing cautious but promising results and safety profiles. Prospective studies and an international registry could provide valuable insights needed for optimal patient selection and protocol refinement.