The overshoot phenomenon in step‐and‐shoot IMRT delivery
Ezzell, Gary A., Chungbin, Suzanne

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 2 | Issue: 3 | Pages: 138-148

10.1120/jacmp.v2i3.2607 | PMID 11602010 Get It

The control loop in the Varian DMLC system (V4.8) requires msec to monitor and halt the irradiation of a segment, causing an “overshoot” effect: the segment ends on a fractional monitor unit larger than that planned. As a result, the actual MU delivered may differ from that planned. In general, for step‐and‐shoot treatments, the first segment receives more, the last receives less, and intermediate segments vary. The overshoot for each segment (ΔMU) is small, approximately 0.6 MU at 600 MU/min Our IMRT planning system (Corvus) produces plans often having more than 20% of the segments with less than 1 MU/segment. Such segments may be skipped if the ΔMU exceeds the segments’ planned MU. Furthermore, QA filming often requires reducing the total MU by a factor of 4–6, increasing the potential for dosimetric error. This study measured ΔMU over a range of MU/min and MU/segment. At MU/segment, the ΔMU was stable, corresponding to a delay of 62 msec. ΔMU became larger and more variable at MU/segment. The behavior was modeled in a computer program that predicted the change in delivered MU/segment and total change in delivered MU to each beamlet. Beams were analyzed for patients receiving 5 field prostate or 9 field head and neck treatments. At 400 MU/min, 28% and 16%, respectively, of the planned segments were skipped. For QA filming, up to 75% of the segments were skipped. The cumulative error averaged MU/beamlet, but individual beamlets had errors exceeding 200%. The effect is most significant for low dose regions. Recommendations are given for deciding when to treat or do QA studies with lower MU/min. In general, treatments are not significantly affected, but QA films taken at reduced MU may be improved if irradiated at lowered MU/min.PACS number(s): 87.53.–j, 87.90.+y
Development of a treatment planning protocol for prostate treatments using intensity modulated radiotherapy
Ezzell, Gary A., Wong, William W. , Schild, Steven E.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 2 | Issue: 2 | Pages: 59-68

10.1120/jacmp.v2i2.2614 | PMID 11604050 Get It

We have developed a treatment planning protocol for intensity‐modulated radiation therapy of the prostate using commercially available inverse planning software. Treatment plans were developed for ten patients using the Corvus version 3.8 planning system, testing various prescription options, including tissue types, dose volume histogram values for the target and normal structures, beam arrangements, and number of intensity levels. All plans were scaled so that 95% of the clinical target volume received 75.6 Gy; mean doses to the prostate were typically 79 Gy. The reproducibility of the inverse planning algorithm was tested by repeating a set of the plans five times. Plans were deemed acceptable if they satisfied predefined dose constraints for the targets and critical organs. Figures of merit for target coverage, target dose uniformity, and organ sparing were used to rank acceptable plans. Certain systematic behaviors of the optimizer were noted: the high dose regions for both targets and critical organs were 5–10 Gy more than prescribed; reducing bladder and rectum tolerance increased the range of doses within the target; increasing the number of fields incrementally improved plan quality. A set of planning parameters was found that usually satisfied the minimum requirements. Repeating the optimization with different beam order produced similar but slightly different dose distributions, which was sometimes useful for finding acceptable solutions for difficult cases. The standard set of parameters serves as a useful starting point for individualized planning.PACS number(s): 87.53.–j, 87.90.+y
Guide to clinical use of electronic portal imaging
Herman, Michael , Kruse, Jon J. , Hagness, C.R.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 1 | Issue: 2 | Pages: 38-57

10.1120/jacmp.v1i2.2645 | PMID 11674818 Get It

The Electronic Portal Imaging Device (EPID) provides localization quality images and computer‐aided analysis, which should in principal, replace portal film imaging. Modern EPIDs deliver superior image quality and an array of analysis tools that improve clinical decision making. It has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments. However, in many radiation therapy clinics EPID technology is not in routine clinical use. This low utilization suggests that the capability and potential of the technology alone do not guarantee its full adoption. This paper addresses basic considerations required to facilitate clinical implementation of the EPID technology and gives specific examples of successful implementations. © 2000 American College of Medical Physics.PACS number(s): 87.53.–j, 87.57.–s
Reimbursement versus effort in medical physics practice in radiation oncology
Herman, Michael , Mills, Michael , Gillin, Michael T.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 4 | Issue: 2 | Pages: 179-187

10.1120/jacmp.v4i2.2533 | PMID 12777154 Get It

The changes in health care reimbursement have the potential to affect the availability of quality medical physicist service in patient care. A survey was conducted by the AAPM Professional Council and the ACMP to collect cost information for special medical physics consultation, CPT4‐77370 and continuing medical physics, CPT4‐77336. The data collected from the survey was compared to current reimbursement schemes for a number of special procedures. Under varying reimbursement schemes, the costs of the medical physics services provided cannot be recaptured by the institution. It remains important for medical physicists to assess our utilization of resources and allocation to each of the services we provide and to understand the implications of policy changes at the federal and local levels. PACS number(s): 87.90.+y, 87.53.–j
Identification and Validation of Colorectal Neoplasia–Specific Methylation Markers for Accurate Classification of Disease
Model, Fabian , Osborn, Neal, Ahlquist, David A. , Gruetzmann, Robert, Molnár, Béla , Sípos, Ferenc , Galamb, Orsolya , Pilarsky, Christian , Saeger, Hans-Detlev, Tulassay, Zsolt , Hale, Kari, Lograsso, Joseph, Adorján, Péter, Lesche, Ralf , Dessauer, Andreas, Kleiber, Joerg, Porstmann, B, Sledziewski, Andrew, Lofton–Day, Catherine, Mooney, Suzanne

Mayo Clinic

Molecular Cancer Research | February 21, 2007 | Volume: 5 | Issue: 2 | Pages: 153-163

10.1158/1541-7786.mcr-06-0034 | PMID 17314273 Get It

Abstract Aberrant DNA methylation occurs early in oncogenesis, is stable, and can be assayed in tissues and body fluids. Therefore, genes with aberrant methylation can provide clues for understanding tumor pathways and are attractive candidates for detection of early neoplastic events. Identification of sequences that optimally discriminate cancer from other diseased and healthy tissues is needed to advance both approaches. Using well-characterized specimens, genome-wide methylation techniques were used to identify candidate markers specific for colorectal neoplasia. To further validate 30 of these candidates from genome-wide analysis and 13 literature-derived genes, including genes involved in cancer and others with unknown functions, a high-throughput methylation-specific oligonucleotide microarray was used. The arrays were probed with bisulfite-converted DNA from 89 colorectal adenocarcinomas, 55 colorectal polyps, 31 inflammatory bowel disease, 115 extracolonic cancers, and 67 healthy tissues. The 20 most discriminating markers were highly methylated in colorectal neoplasia (area under the receiver operating characteristic curve > 0.8; P < 0.0001). Normal epithelium and extracolonic cancers revealed significantly lower methylation. Real-time PCR assays developed for 11 markers were tested on an independent set of 149 samples from colorectal adenocarcinomas, other diseases, and healthy tissues. Microarray results could be reproduced for 10 of 11 marker assays, including eight of the most discriminating markers (area under the receiver operating characteristic curve > 0.72; P < 0.009). The markers with high specificity for colorectal cancer have potential as blood-based screening markers whereas markers that are specific for multiple cancers could potentially be used as prognostic indicators, as biomarkers for therapeutic response monitoring or other diagnostic applications, compelling further investigation into their use in clinical testing and overall roles in tumorigenesis. (Mol Cancer Res 2007;5(2):153–63)
Brain protection using autologous bone marrow cell, metalloproteinase inhibitors, and metabolic treatment in cerebral ischemia
Baker, Andrew H. , Sica, Vincenzo, Work, Lorraine M. , Williams‐Ignarro, Sharon, Nigris, Filomena de , Lerman, Lilach O. , Casamassimi, Amelia , Lanza, Alessandro , Schiano, Concetta , Rienzo, Monica , Ignarro, Louis J., Napoli, Claudio , Baker, Andrew H

Mayo Clinic

Proceedings of the National Academy of Sciences | February 21, 2007 | Volume: 104 | Issue: 9 | Pages: 3597-3602

10.1073/pnas.0611112104 | PMID 17360688 Get It

Despite advances in imaging, understanding the underlying pathways, and clinical translation of animal models of disease there remains an urgent need for therapies that reduce brain damage after stroke and promote functional recovery in patients. Blocking oxidant radicals, reducing matrix metalloproteinase-induced neuronal damage, and use of stem cell therapy have been proposed and tested individually in prior studies. Here we provide a comprehensive integrative management approach to reducing damage and promoting recovery by combining biological therapies targeting these areas. In a rat model of transient cerebral ischemia (middle cerebral artery occlusion) gene delivery vectors were used to overexpress tissue inhibitor of matrix metalloproteinase 1 and 2 (TIMP1 and TIMP2) 3 days before ischemia. After occlusion, autologous bone marrow cells alone or in combination with agents to improve NO bioavailability were administered intraarterially. When infarct size, BrdU incorporation, and motor function recovery were determined in the treatment groups the largest beneficial effect was seen in rats receiving the triple combined therapy, surpassing effects of single or double therapies. Our study highlights the utility of combined drug, gene, and cell therapy in the treatment of stroke.
Measurement of Caval Blood Flow with MRI During Respiratory Maneuvers: Implications for Vascular Contrast Opacification on Pulmonary CT Angiographic Studies
Kuzo, Ronald S. , Pooley, Robert A. , Gerber, Thomas C., Crook, Julia E. , Heckman, Michael G. , Kuzo, Ronald S

Mayo Clinic

American Journal of Roentgenology | February 20, 2007 | Volume: 188 | Issue: 3 | Pages: 839-842

10.2214/ajr.06.5035 | PMID 17312076 Get It

Imaging Evaluation of Tendon Sheath Disease: Self-Assessment Module
Roberts, Catherine C. , Liu, Patrick T., Chew, Felix S.

Mayo Clinic

American Journal of Roentgenology | February 20, 2007 | Volume: 188 | Issue: 3_supplement | Pages: S10-S12

10.2214/ajr.06.1484 | PMID 19645124 Get It

Imaging Evaluation of the Solitary Pulmonary Nodule: Self-Assessment Module
Ko, Jane P. , Roberts, Catherine C. , Berger, William, Chew, Felix S.

Mayo Clinic

American Journal of Roentgenology | February 20, 2007 | Volume: 188 | Issue: 3_supplement | Pages: S1-S4

10.2214/ajr.06.1304 | PMID 19645123 Get It

AJR Teaching File: Cavitated Mass with Hypertrophic Osteoarthropathy
McNaughton, Dean Alexander, Nguyen, Ba D.

Mayo Clinic

American Journal of Roentgenology | February 20, 2007 | Volume: 188 | Issue: 3_supplement | Pages: S7-S9

10.2214/ajr.06.0150 | PMID 17312084 Get It