Citations 11

Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels

Radiology | September 29, 2020 | Volume: 297 | Issue: 3 | Pages: 699-707

10.1148/radiol.2020200969 | PMID 32990514

Prospective Pilot Evaluation of Radiologists and Computer-aided Pulmonary Nodule Detection on Ultra–low-Dose CT With Tin Filtration

Journal of Thoracic Imaging | July 26, 2018 | Volume: 33 | Issue: 6 | Pages: 396-401

10.1097/rti.0000000000000348 | PMID 30048344

Purpose: The aim of this study was to evaluate the ability of computer-aided detection (CAD) and human readers to detect pulmonary nodules ≥5 mm using 100 kV ultra–low-dose computed tomography (ULDCT) utilizing a tin filter. Materials and Methods: After informed consent, 55 patients prospectively underwent standard-dose chest CT (SDCT) using 120 kV followed by ULDCT using 100 kV/tin. Reference nodules ≥5 mm were identified by a thoracic radiologist using SDCT. Four thoracic radiologists marked detected nodules on SDCT and ULDCT examinations using a dedicated computer workstation. After a 6-month memory extinction, readers were shown the same ULDCT cases with all CAD markings as well as their original detections, and characterized CAD detections as true positive or false positive. Results: Volume CT Dose index (CTDIvol) for SDCT and ULDCT were 5.3±2 and 0.4±0.2 mGy (P<0.0001), respectively. Forty-five reference nodules were detected in 30 patients. Reader sensitivity varied widely but similarly for SDCT (ranging from 45% to 87%) and ULDCT (45% to 83%). CAD sensitivity was 76% (34/45) for SDCT and 71% (32/45) for ULDCT. After CAD, reader sensitivity substantially improved by 19% and 18% for 2 readers, and remained nearly unchanged for the other 2 readers (0% and 2%), despite reader perception that many more nodules were identified with CAD. There was a mean of 2 false-positive CAD detections/case. Conclusions: ULDCT with 100 kV/tin reduced patient dose by over 90% without compromising pulmonary nodule detection sensitivity. CAD can substantially improve nodule detection sensitivity at ULDCT for some readers, maintaining interobserver performance.
The breadth of the diaphragm: updates in embryogenesis and role of imaging

The British Journal of Radiology | February 27, 2018 | Volume: No volume available | Issue: No issue available | Pages: 20170600

10.1259/bjr.20170600 | PMID 29485899

Solving a Mystery . . . 8 Years Later

Journal of Investigative Medicine High Impact Case Reports | January 24, 2018 | Volume: 6 | Issue: No issue available | Pages: No page available

10.1177/2324709617752962 | PMID 29435464

Erdheim-Chester disease is a rare non-Langerhans cell histiocytosis with multisystem involvement and insidious symptoms. In this article, we describe an interesting case of Erdheim-Chester disease that was eventually diagnosed 8 years after symptoms initially started.
Evaluation of a projection-domain lung nodule insertion technique in thoracic computed tomography

Journal of Medical Imaging | March 31, 2017 | Volume: 4 | Issue: 1 | Pages: 013510

10.1117/1.jmi.4.1.013510 | PMID 28401176

Congenital Lobar Emphysema in an Adult

American Journal of Respiratory and Critical Care Medicine | June 8, 2016 | Volume: 194 | Issue: 3 | Pages: 377-378

10.1164/rccm.201602-0289im | PMID 27275927

Evaluation of Suspected Aspirated Beverage Can Pull Tab: Radiographs May Not Be Enough

Case Reports in Radiology | December 14, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-3

10.1155/2014/196960 | PMID 25580344

A 67-year-old male presented to the emergency department with concern for accidental aspiration of an aluminum beverage can pull tab. Neck and chest radiographs did not reveal an aspirated foreign body. Despite ongoing complaint of dysgeusia and adamancy of aspiration by the patient, he was discharged to home without recommendation for further follow-up. Seven months later, a computed tomography (CT) scan of the chest performed as part of an unrelated lung cancer work up confirmed the presence of a left mainstem bronchus metallic foreign body compatible with a pull tab. This case report illustrates the poor negative predictive value of radiographs for a suspected aluminum foreign body and demonstrates the superiority of CT for this purpose. In such presentations it is imperative to have a low threshold for performing further diagnostic evaluation with CT due to the relatively high radiolucency of aluminum.
ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

American Journal of Roentgenology | February 28, 2013 | Volume: 184 | Issue: 5 | Pages: 1413-1419

10.2214/ajr.184.5.01841413 | PMID 15855088

Measurement of Caval Blood Flow with MRI During Respiratory Maneuvers: Implications for Vascular Contrast Opacification on Pulmonary CT Angiographic Studies

American Journal of Roentgenology | February 20, 2007 | Volume: 188 | Issue: 3 | Pages: 839-842

10.2214/ajr.06.5035 | PMID 17312076

Computed Tomographic Imaging of Anomalous Coronary Arteries

Circulation | October 7, 2002 | Volume: 106 | Issue: 15 | Pages: No page available

10.1161/01.cir.0000033844.99174.d1 | PMID 12370233