Citations

Mayo Clinic

Clear

23 citation(s) found for "Yang, Ta-Wei".

Towards Automated Quality Assurance: Integrating Deep Learning and Classical ML into the Digital Radiography Pipeline
Chen, Hsuan‐Yu , Chou, Cheng‐Fu , Liao, Sheng-Hung, Wu, Mia , Chen, Kuan-Yi, Yang, Ta-Wei , Chang, Chih‐Hao , Fan, Jungwei Wilfred, Chang, Chih-Hao , Fan, Jungwei

Diagnostics | July 6, 2026 | Volume: 16 | Issue: 13 | Pages: 2111

10.3390/diagnostics16132111 | PMID 42449892 Get It

Background/Objectives: To develop and evaluate a deep learning-based quality control system for Lumbar Spinal Digital Radiographs (LSDR), designed to automate and improve their evaluation and reduce reliance on manual reviews. Methods: This retrospective study utilized a deep learning workflow comprising image segmentation, feature extraction, and a classification model. The dataset, including anteroposterior (AP) and lateral (LAT) X-ray images, was expanded through data augmentation techniques. Four U-Net-based models were assessed: standard U-Net, Swin-UNet, Attention U-Net, and Attention U-Net with the weight map, with the latter selected for its superior performance. Extracted features, such as brightness, contrast, and anatomical positioning, were used in an XGBoost classifier, which was evaluated using mean intersection over union (mIoU), accuracy, sensitivity, specificity, and AUC. Results: The Attention U-Net with weighted attention outperformed the other models, achieving high mIoU scores in both AP and LAT views. The XGBoost classifier achieved the best performance in classifying images as “qualified” or “unqualified,” with an AUC of approximately 0.9, high accuracy, and balanced sensitivity and specificity. This approach effectively addressed class imbalances and improved model accuracy compared to traditional machine learning models such as MLP and SVM. Conclusions: The developed automated quality control system demonstrated potential for enhancing image quality, enhancing diagnostic reliability, and optimizing clinical workflow efficiency.
Experimentally determined proton discrete spot scanning time structures for an improved synchrotron‐based PBS spot delivery time model
Lee, James Kuan Huei , Chua, Clifford Ghee Ann , Lew, Kah Seng, Koh, Calvin Wei Yang , Gan, Jun Ken , Fu, Kailin , Master, Zubin, Lee, James Cheow Lei, Park, Sung Yong, Yagi, Masashi , Lee, Kang Hao , Fu, Kailin, Master, Zubin, Bettiol, Andrew Anthony , Furutani, Keith M. , Park, Sung Yong , Tan, Hong Qi

Medical Physics | June 25, 2026 | Volume: 53 | Issue: 7 | Pages: No page available

10.1002/mp.70553 | PMID 42347740 Get It

Abstract Background An accurate discrete spot scanning (DSS) beam delivery time (BDT) model is essential, particularly as 4D dynamic dose accumulation calculations rely on machine‐specific time models for reliable interplay evaluation. Purpose To derive a BDT model for a synchrotron‐based Hitachi Probeat PBS proton system from oscilloscope measurements of key BDT structures, including multi‐energy extraction (MEE) characteristics. Methods Key BDT structures were characterized using oscilloscope measurements, supplemented by delivery log files where appropriate. Spot‐to‐spot scanning trajectories were visualized using a CROSSmini 2D strip ionization chamber (Liverage Biomedical Inc, Taiwan) via the dose‐driven continuous scanning (DDCS) mode. The MEE design and MEE charge recapture efficiencies were also characterized. In addition, the impact of the number of delivered spots on both the extractable fraction of charge and MEE recapture efficiency was investigated. Results An improved synchrotron‐based BDT model was derived that incorporates dead times between radiofrequency knockout (RFK) and high‐speed steering magnet (HSST) signals. Spot‐to‐spot movement follows a “hockey‐stick”‐like behavior where the effective spot‐to‐spot move time is governed by the slower axis. An energy‐dependent variation in the number of MEE layers deliverable per spill was also observed, with fewer MEE layers per spill (1–3) was observed in low and high energy ranges compared to the mid‐energy range (4–5), deviating from the nominal vendor value of five MEE layers per spill per block. A reduction in the extractable fraction of charge was observed with an increasing number of spots per spill, while increasing the number of delivered spots in the preceding layer significantly reduced the MEE recapture efficiency. Conclusion MEE characteristics should be incorporated into synchrotron‐based time models for accurate beam delivery modeling. The methodology presented here also provides a framework for centers seeking to derive machine‐specific delivery time models for their proton systems.
The Effect of Glaucomatous Visual Field Defects on Driving: A Systematic Review
Toh, Zhi Hong , Koh, Serene Yi Ning, Munro, Yasmin Lynda, Ang, Bryan Chin Hou , Ang, Bryan C H , Koh, Serene Yi Ning, Yang, Wei Yun Lily, Munro, Yasmin Lynda

Journal of Glaucoma | September 17, 2025 | Volume: 34 | Issue: 11 | Pages: 837-852

10.1097/ijg.0000000000002633 | PMID 40960416 Get It

Précis: Glaucoma patients with significant visual field defects show poorer driving performance, higher collision risks, and a greater likelihood of driving cessation. They face difficulties with lane maintenance, slower hazard responses, and self-regulation while driving. Purpose: Glaucoma is a chronic, progressive optic neuropathy associated with visual field (VF) defects, which in advanced disease has been shown to affect patients’ activities of daily living. This systematic review qualitatively analyzes existing literature that explores the impact of glaucomatous VF loss on the driving performance of glaucoma patients, the extent of driving limitation and cessation, as well as the risk of motor vehicle collisions (MVCs). Methods: A literature search of MEDLINE and Embase (via Ovid), PubMed, Cochrane Library, and Web of Science databases was performed for studies published from 2003 to 2023, with the terms “glaucoma,” “visual field defect/disorder,” and “driving,” followed by selective vetting based on inclusion criteria. Within studies, data pertaining to study design, subject demographics, VF defect characteristics, driving performance and related outcomes were extracted. Results: Initial search yielded 835 studies, with 20 studies selected. Three more studies were included through hand-searching, with a total of 23 studies included for final review. Moderate to severe VF defects resulted in poorer driving performance, with slower response times to road hazards, decreased ability for lane maintenance, and increased difficulty driving at night. Patients with more severe VF defects and with bilateral glaucoma were more likely to limit or cease driving compared with those with milder and unilateral glaucoma. A greater severity of VF loss was associated with a higher risk of MVCs. Conclusion: More severe glaucomatous VF and bilateral glaucoma is associated with worse driving performances and a higher risk of MVCs, in both simulator and real-world settings.
Quality assurance of the inter‐spot beam delivery of a dose driven continuous scanning proton therapy system
Chua, Clifford Ghee Ann , Lew, Kah Seng, Koh, Calvin Wei Yang , Wibawa, Andrew , Master, Zubin , Lee, James Cheow Lei, Beltran, Chris , Tan, Hong Qi , Beltran, Chris J , Furutani, Keith M. , Lee, Kang Hao , Park, Sung Yong

Medical Physics | August 14, 2025 | Volume: 52 | Issue: 8 | Pages: No page available

10.1002/mp.18050 | PMID 40804772 Get It

Abstract Background Dose‐driven continuous scanning (DDCS) is a type of beam delivery in Hitachi pencil beam scanning (PBS) particle therapy system. Particle beam is irradiated continuously between spots to achieve a higher effective dose rate and a shorter beam delivery time. The beam is only turned off at break spots, the end of a treatment layer and during spill change. The break spot is a unique feature of the DDCS introduced by the treatment planning system (TPS) to interrupt continuous scanning. DDCS separates the dose delivery of a spot into a move dose and stop dose components. The move dose is controlled by the scanning speed and beam current, while the stop dose delivers the remaining monitor units (MUs). Hence, rigorous quality assurance (QA) of the scanning speed and functionality of break spot are required to ensure safe and successful DDCS delivery. Purpose We aim to report for the first time the QA methodology and result for DDCS, focusing on the scanning speed and break spot validation. Methods A rectangular spiral irradiation pattern with different degree of break spots were irradiated on a 2D strip ionization chamber (CROSSmini) detector using 50 time resolution to validate the break spots. Four methods of measuring scanning speeds were proposed. Using a spiral irradiation pattern, methods one and two applied linear regression to the scanning time measured by the CROSSmini for different inter‐spot distances, with measurements taken at sampling rates of 5 and 20 kHz, respectively. Methods three and four measured the scanning time of single inter‐spot distances in the X and Y directions. Method three measured the scanning time with the CROSSmini while method four measured the rise and fall time of the scanning magnet (SCM) current. All measurements were performed with 70.2, 150.2 and 228.7 MeV proton beam energies and three different beam currents of 8, 14 and 20 MU/s. Lastly, the scanning speed tolerance limit was calculated analytically under the requirement of avoiding a beam abort when the stop dose was less than zero. Results The data recorded by the CROSSmini under the spiral irradiation patterns with break spots was reconstructed into a 2D dose, and the break spots’ operations were visually validated for all the energies and beam currents. There were no statistically significant difference in the measured X and Y scanning speeds across the four methods. However, the last method involving the SCM current yielded the largest type A uncertainty of up to 25% () due to the noisy signal. The first method with the linear regression and 5 kHz acquisition rate was preferred due to a smaller type A uncertainty of up to 2.0% and a lower false negative rate in detecting the rising and falling edges during scanning. The calculated tolerance limit based on our current DDCS setting was found to be 0.50 times of the expected scanning speed. Conclusion We have introduced QA protocols for DDCS, designed to ensure complete and safe beam delivery without interruptions caused by move doses exceeding planned spot doses.
Selective Elimination of Breast Surgery for Invasive Breast Cancer
Kuerer, Henry M. , Valero, V, Krishnamurthy, Savitri, Diego, Emilia J. , Lin, Heather , Shen, Yu , Mitchell, Melissa P. , Yang, Wei , Group, Exceptional Responders Study, Moseley, Tanya W. , Leung, Jessica WT, Huang, Monica L. , Parra, Raquel FD van la, Teshome, Mediget , Hwang, Rosa F. , Miggins, Makesha, Piotrowski, Matthew J., Refinetti, Ana P, Ehlers, Richard A., Mouabbi, Jason , Colen, Jessica Suarez, Loveland‐Jones, Catherine, Lesnikowski, Beth Ann, Samiian, Laila, Chong, Clayton, Black, Dalliah M. , Desyder, Sarah M, Nguyen, Tuyen , Smith, Benjamin D. , Krishnamurthy, Savitri , Johnson, Helen Margaret , Lucci, Anthony , Shaitelman, Simona Flora , Boughey, Judy C. , White, Richard L., Hunt, Kelly K. , Rauch, Gaiane M. , Group, Exceptional Responders Study, Candelaria, Rosalind P. , Adrada, Beatriz E. , Arribas, Elsa , Ramirez, David Luis , Sun, Susie X.

JAMA Oncology | March 28, 2025 | Volume: 11 | Issue: 5 | Pages: 529

10.1001/jamaoncol.2025.0207 | PMID 40152443 Get It

Importance Neoadjuvant systemic therapy (NST) has been associated with pathologic complete response (pCR) in up to 60% of breast cancers (BCs). The findings of this trial question the necessity of surgery. Objective To report preplanned 5-year efficacy outcomes evaluating radiotherapy alone without breast surgery in patients selected with image-guided vacuum assisted biopsy (VAB). Design, Setting, and Participants This single-arm, prospective, phase 2 nonrandomized clinical trial was conducted at 7 US medical centers and included women 40 years or older with cT1-2N0-1M0 ERBB2 -positive (formerly HER2 -positive) or triple-negative invasive BC who showed residual breast lesions after NST of less than 2 cm on imaging. Enrollment was from March 6, 2017, to November 9, 2021. Data analysis was from October to December 2024. Intervention Image-guided VAB of the tumor bed (9G with a minimum of 12 cores) was performed after standard NST. Patients with clinically node-negative disease at diagnosis and no residual cancer in the breast on post-NST VAB underwent whole-breast radiotherapy with a boost without breast or axillary surgery. Patients with initial documented nodal disease and a breast pCR on VAB underwent targeted axillary dissection, while those with residual cancer when undergoing VAB had standard breast and axillary surgery. Patients were monitored with physical examinations and mammography every 6 months. Main Outcome Measures The primary outcome was ipsilateral breast tumor recurrence. Results Fifty patients (median [IQR] age, 62 [55-77] years) were enrolled and underwent post-NST VAB. Twenty-nine (58%) and 21 (42%) patients had ERBB2 -positive and triple-negative invasive BC, respectively. Breast pCR on VAB was identified in 31 patients (62%; 95% CI, 47.2%-75.34%), and axillary pCR was identified among all 8 patients with initial nodal metastases and breast pCR on VAB who underwent targeted axillary dissection. At a median follow-up of 55.4 (IQR, 44.0-63.5) months, the ipsilateral breast tumor recurrence rate was 0%, and disease-free and overall survival rates were 100% for patients without breast surgery. Conclusions and Relevance The results of this nonrandomized clinical trial that reported preplanned 5-year outcomes suggest that omission of breast surgery in select patients after NST may be feasible, with no recurrences seen. More confirmatory studies are necessary before this new approach alters surgical practice. Trial Registration ClinicalTrials.gov Identifier: NCT02945579
Neuro-Ophthalmic Literature Review
Chen, John J. , Hung, Wei-Che , Vaphiades, Michael S., Chen, John J , Mak, Andrew C. Y. , Verma, Rashmi , Zhang, Xiaojun

Neuro-Ophthalmology | January 7, 2025 | Volume: 49 | Issue: 1 | Pages: 105-110

10.1080/01658107.2024.2431470 Get It

Neuro-Ophthalmic Literature Review
Chen, John J. , Hung, Wei-Che , Jindahra, Panitha , Vaphiades, Michael S., Zhang, Xiaojun , Chen, John J , Mak, Andrew C. Y. , McClelland, Collin M. , Verma, Rashmi , Xie, Jim Shenchu

Neuro-Ophthalmology | November 19, 2024 | Volume: 48 | Issue: 6 | Pages: 464-471

10.1080/01658107.2024.2408954 Get It

Neuro-Ophthalmic Literature Review
Bellows, David A., Chen, John J. , Hung, Wei-Che , Vaphiades, Michael S., Chen, John J , Mak, Andrew C. Y. , McClelland, Collin M. , Verma, Rashmi , Zhang, Xiaojun

Neuro-Ophthalmology | August 12, 2024 | Volume: 48 | Issue: 5 | Pages: 381-389

10.1080/01658107.2024.2384339 Get It

Neuro-Ophthalmic Literature Review
Bellows, David A., Chen, John J. , Hung, Wei-Che , Vaphiades, Michael S., Chen, John J , Mak, Andrew C. Y. , Verma, Rashmi , Weber, Konrad Peter

Neuro-Ophthalmology | June 24, 2024 | Volume: 48 | Issue: 4 | Pages: 310-314

10.1080/01658107.2024.2356494 Get It

Implementing dispersion measurement as part of scanning proton therapy commissioning and quality assurance
Tan, Hong Qi , Lew, Kah Seng, Koh, Calvin Wei Yang , Wibawa, Andrew , Yeap, Ping Lin , Master, Zubin , Lee, James Cheow Lei, Beltran, Chris , Furutani, Keith M. , Park, Sung Yong , Furutani, Keith M , Beltran, Chris J , Park, Sung Yong

Physics in Medicine & Biology | October 19, 2023 | Volume: 68 | Issue: 22 | Pages: 225001

10.1088/1361-6560/ad0536 | PMID 37857314 Get It

Abstract Introduction . Dispersion in an accelerator quantifies the deviation of the proton trajectory when there is a momentum deviation. We present for the first time a safe method of measuring dispersion in the clinic, using a scintillator detector and the momentum deviations within a spill. This is an important accelerator quantity as we found that this is the reason behind the large dose fluctuation in our absolute dosimetry measurement. Methods . Dispersions are measured for nine energies in a Hitachi ProBeat system at three locations (isocenter and at two profile monitors) and at two gantry angles (0 and 90 degrees) by first measuring the spot position and momentum drift within a spill. The spot position drift is measured by the XRV-4000 at the isocenter, and by the two profile monitors located at 0.57 and 2.27 m from the isocenter. The momentum drift is calculated from the intra-spill range drift which is measured using the Ranger accessory. The dispersion at isocenter and its gradient are calculated using the weighted least square regression on the measured dispersions at the three locations. A constraint is formulated on the dispersion and its gradient to ensure minimal intra-spill spot position deviation around the isocenter. Results . The measured intra-spill range and spot positional drift at isocenter are less than 0.25 mm and 0.7 mm respectively. The momentum spread calculated from the range drift are less than 0.08%. The dispersion at the isocenter ranged from 0.50 to 4.30 m and the zero-crossing happens upstream of isocenter for all energies. 2 of the 9 energies (168.0 and 187.5 MeV) violated the constraint and has an intra-spill spot positional deviation greater than 1.0 within 5 cm from the isocenter. Conclusion . This measurement is recommended as part of commissioning and annual quality assurance for accelerator monitoring and to ensure intra-spill spot deviations remain low.