Implementing dispersion measurement as part of scanning proton therapy commissioning and quality assurance
Tan, Hong Qi , Lew, Kah Seng, Koh, Calvin Wei Yang , Wibawa, Andrew , Yeap, Ping Lin , Master, Zubin , Lee, James Cheow Lei, Beltran, Chris , Furutani, Keith M. , Park, Sung Yong , Furutani, Keith M , Beltran, Chris J , Park, Sung Yong

Physics in Medicine & Biology | October 19, 2023 | Volume: 68 | Issue: 22 | Pages: 225001

10.1088/1361-6560/ad0536 Get It

Abstract Introduction . Dispersion in an accelerator quantifies the deviation of the proton trajectory when there is a momentum deviation. We present for the first time a safe method of measuring dispersion in the clinic, using a scintillator detector and the momentum deviations within a spill. This is an important accelerator quantity as we found that this is the reason behind the large dose fluctuation in our absolute dosimetry measurement. Methods . Dispersions are measured for nine energies in a Hitachi ProBeat system at three locations (isocenter and at two profile monitors) and at two gantry angles (0 and 90 degrees) by first measuring the spot position and momentum drift within a spill. The spot position drift is measured by the XRV-4000 at the isocenter, and by the two profile monitors located at 0.57 and 2.27 m from the isocenter. The momentum drift is calculated from the intra-spill range drift which is measured using the Ranger accessory. The dispersion at isocenter and its gradient are calculated using the weighted least square regression on the measured dispersions at the three locations. A constraint is formulated on the dispersion and its gradient to ensure minimal intra-spill spot position deviation around the isocenter. Results . The measured intra-spill range and spot positional drift at isocenter are less than 0.25 mm and 0.7 mm respectively. The momentum spread calculated from the range drift are less than 0.08%. The dispersion at the isocenter ranged from 0.50 to 4.30 m and the zero-crossing happens upstream of isocenter for all energies. 2 of the 9 energies (168.0 and 187.5 MeV) violated the constraint and has an intra-spill spot positional deviation greater than 1.0 within 5 cm from the isocenter. Conclusion . This measurement is recommended as part of commissioning and annual quality assurance for accelerator monitoring and to ensure intra-spill spot deviations remain low.
The effect of spill change on reliable absolute dosimetry in a synchrotron proton spot scanning system
Tan, Hong Qi , Lew, Kah Seng, Koh, Calvin Wei Yang , Wibawa, Andrew , Master, Zubin , Beltran, Chris , Park, Sung Yong , Beltran, Chris J , Park, Sung Yong , Furutani, Keith M.

Medical Physics | June 7, 2023 | Volume: 50 | Issue: 7 | Pages: 4067-4078

10.1002/mp.16531 Get It

AbstractBackgroundAbsolute dosimetry measurement is an integral part of Treatment Planning System (TPS) commissioning and it involves measuring the integrated absorbed dose to water for all energies in a pencil beam scanning delivery system. During the commissioning of Singapore's first proton therapy center, a uniform scanned field with an Advanced Markus chamber method was employed for this measurement, and a large dose fluctuation of at least 5% was observed for 10% of the energy layers during repeated measurements.PurposeThis study aims to understand the root cause of this fluctuation by relating the actual delivered spot information in the log file with the charge measurement by the ion chambers.MethodsA dedicated pencil beam dose algorithm was developed, taking into account the log file parameters, to calculate the dose for a single energy layer in a homogeneous water phantom. Three energies, 70.2, 182.7, and 228.7 MeV were used in this study, with the 182.7 MeV energy exhibiting large dose fluctuation. The dose fluctuation was investigated as a function of detector's sizes (pinpoint 3D, Advanced Markus, PTW 34070, and PTW 34089) and water depth (2 , 6, and 20 cm). Twelve ion chambers measurements were performed for each chamber and depth. The comparison of the theoretically predicted integrated dose and the charge measurement served as a validation of the algorithm.ResultsAbout 5.9% and 9.6% dose fluctuation were observed in Advanced Markus and pinpoint 3D measurements at 2 cm depth for 182.7 MeV, while fluctuation of 1.6% and 1.1% were observed in Advanced Markus with 228.7 and 70.2 MeV at similar depth. Fluctuation of less than 0.1% was observed for PTW34070 and PTW 34089 for all energies. The fluctuation was found to diminish with larger spot size at 20 cm depth to 1.3% for 182.7 MeV. The theoretical and measured charge comparison showed a high linear correlation of for all datasets, indicating the fluctuation originated from the delivered spot characteristics. The cause of fluctuation was identified to be due to the spill change occurring close to the detector, and since the spot positional deviation profiles were different between two spills, this resulted in local hot spots between columns of spots. The actual position of spill change varies randomly during measurement, which led to a random occurrence of hot spot within the detector's sensitive volume and a fluctuating dose measurement.ConclusionThis is the first report of a dose fluctuation greater than 5% in absolute dosimetry measurement with a uniform scanned field and the cause of the fluctuation has been conclusively determined. It is important to choose the MU and scanning pattern carefully to avoid spill change happening when the spot delivery is near the detector.