Objective Glaucoma and cancer are debilitating diseases with increasing global prevalence and morbidity. However, current literature lacks a systematic consolidation of their relationships and interactions. This systematic review aims to (A) summarize the association between intraocular/non-ocular cancers and their treatments with the prevalence and etiology of glaucoma, (B) explore glaucoma as a risk factor for complications or poor prognosis for intraocular cancer, and (C) explore the management of glaucoma secondary to cancer therapies. Methods A systematic search was performed from inception to July 2025 across three databases with variants of ‘cancer’ and ‘glaucoma’ as search terms. Findings were narratively synthesized. Results Of 8,103 identified studies, 44 were included in this review. Eighteen studies reported increased glaucoma prevalence amongst intraocular and non-ocular cancer patients. Fifteen studies suggested increased risk of regional invasion, metastases, and high-risk histopathologies when intraocular cancers co-occurred with glaucoma. Corticosteroids in cancer therapy have been linked to intraocular pressure (IOP) elevation, while androgen deprivation therapy was associated with lowered glaucoma risk. Conclusion Given the relationship between glaucoma and intraocular/non-ocular cancers, strategies to monitor and manage glaucoma risk following cancer diagnosis and/or therapy may be considered. Glaucoma may be an early sign of complications in intraocular cancers.
Thirty-Six-Month Multicentre Outcomes of Combined Phacoemulsification and Hydrus Microstent Implantation in Eyes With Normal Tension Glaucoma
Precis: This retrospective multicentre study of 77 NTG eyes undergoing phacoemulsification and Hydrus implantation showed a sustained reduction in medication burden, while maintaining IOP levels. Complications were rare and nonsight-threatening. Purpose: To evaluate 36-month outcomes of combined phacoemulsification and Hydrus Microstent implantation (Phaco-Hydrus) in eyes with normal tension glaucoma (NTG). Methods: This multicentre retrospective study included 77 NTG eyes from Singapore and Canada that underwent Phaco-Hydrus between 2014 and 2023. Primary outcomes were changes in intraocular pressure (IOP) and medication burden, and cumulative success probabilities from Kaplan-Meier (KM) analyses. Longitudinal changes were analysed using generalized estimating equations. Results: Of 77 eyes, 31 completed 36 months of follow-up. Mean baseline IOP and medications was 13.5±2.5 mm Hg and 1.7±0.9, respectively. No significant reductions in IOP were observed. A sustained reduction in medication use was observed at all follow-up timepoints ( P ≤0.001). At 36 months, medication use decreased by −0.7±0.2 [adjusted mean difference±SE of the mean [SEM]]. Proportion of medication-free eyes increased from 7.8% (n=6/77) at baseline to 45.2% (n=14/31) at 36 months. Cumulative success probabilities varied widely based on definitions. When defined as a decrease in ≥1 medication from baseline without an increase in IOP, or IOP ≤15 mm Hg and reduced ≥20% from baseline while medication-free, and no additional laser or incisional glaucoma surgery, this was 40.7% at 36 months. No visual field mean deviation progression was detected. Adverse events were infrequent and nonsight-threatening. Conclusion: In eyes with NTG, Phaco-Hydrus may offer a greater role in medication reduction or achieving a medication-free status over 36 months, rather than absolute IOP reduction.
The Effect of Glaucomatous Visual Field Defects on Driving: A Systematic Review
Précis: Glaucoma patients with significant visual field defects show poorer driving performance, higher collision risks, and a greater likelihood of driving cessation. They face difficulties with lane maintenance, slower hazard responses, and self-regulation while driving. Purpose: Glaucoma is a chronic, progressive optic neuropathy associated with visual field (VF) defects, which in advanced disease has been shown to affect patients’ activities of daily living. This systematic review qualitatively analyzes existing literature that explores the impact of glaucomatous VF loss on the driving performance of glaucoma patients, the extent of driving limitation and cessation, as well as the risk of motor vehicle collisions (MVCs). Methods: A literature search of MEDLINE and Embase (via Ovid), PubMed, Cochrane Library, and Web of Science databases was performed for studies published from 2003 to 2023, with the terms “glaucoma,” “visual field defect/disorder,” and “driving,” followed by selective vetting based on inclusion criteria. Within studies, data pertaining to study design, subject demographics, VF defect characteristics, driving performance and related outcomes were extracted. Results: Initial search yielded 835 studies, with 20 studies selected. Three more studies were included through hand-searching, with a total of 23 studies included for final review. Moderate to severe VF defects resulted in poorer driving performance, with slower response times to road hazards, decreased ability for lane maintenance, and increased difficulty driving at night. Patients with more severe VF defects and with bilateral glaucoma were more likely to limit or cease driving compared with those with milder and unilateral glaucoma. A greater severity of VF loss was associated with a higher risk of MVCs. Conclusion: More severe glaucomatous VF and bilateral glaucoma is associated with worse driving performances and a higher risk of MVCs, in both simulator and real-world settings.
Advancements in Visual Field Testing: A Systematic Review of the 24-2C Test Grid
A systematic review was conducted of studies published up to 30 August 2024. Studies comparing conventional visual field (VF) indices, ability to detect central visual field defects (CVFDs), structure–function (S-F) concordance, and test characteristics across the HVF 24-2C SITA-Faster, 24-2 SITA-Standard/Faster, and 10-2 SITA-Standard/Fast tests were included. Eight studies with 1239 subjects (49.1% male; mean age, 54.8–66.9 years) were analyzed. The 24-2C produced similar global VF indices compared to the 10-2 and 24-2 (Standard/Faster) (ICC = 0.95 and 0.80, p < 0.001), detected more VF defects and CVFD clusters, and demonstrated greater S-F concordance than the 24-2 (Standard/Faster). Although the 10-2 (Standard/Fast) detected significantly more CVFDs and had a greater S-F concordance, the agreement between the 24-2C and 10-2 grids was substantial (ĸ = 0.488 to 0.708). The 24-2C was also faster compared to the 24-2 Standard and 10-2 (Standard/Fast), with comparable false positives, higher false negatives, and fewer fixation losses than the 24-2 Standard. In conclusion, the HVF 24-2C is quicker and identifies more CVFDs than the 24-2 grid, demonstrates high agreement with the 10-2 grid, and aids in CVFD screening.
Trabeculectomy Bleb Characteristics in Relation to Bleb Success Using Anterior Segment Optical Coherence Tomography–A Systematic Review and Meta-Analysis
Précis: ASOCT features of greater bleb height, thicker bleb walls, and lower reflectivity are associated with trabeculectomy success, supporting the ASOCT’s utility in monitoring and predicting outcomes postsurgery through standardized imaging protocols. Purpose: To evaluate and quantify the relationship between bleb characteristics on ASOCT with surgical outcomes. Methods: A literature search was conducted across Medline, Embase, Cochrane, and Scopus for studies from the past 20 years, until 16 September 2024, on “glaucoma,” “trabeculectomy,” and “ASOCT.” Data collected included patient characteristics, each study’s definition of bleb success, clinical outcomes, as well as bleb characteristics. A literature review was conducted on studies that could not be used for meta-analysis. Results: Eleven studies, with a pooled total of 528 eyes in 517 patients, were included in the final meta-analysis. Successful blebs had significantly higher mean bleb height [mean difference (MD) 0.38 mm, 95% CI: 0.20-0.56 mm, P=0.002], greater maximum bleb wall thickness (MD: 0.21 mm, 95% CI: 0.07-0.35 mm, P=0.009), and decreased reflectivity (MD: −48.9%, 95% CI: −78.3 to −19.4%, P=0.010), compared with failed blebs. No significant differences were found in bleb fluid cavity height and bleb area. Narrative synthesis revealed that wider blebs, increased fluid-filled cavity height, increased number of microcysts, larger filtration opening widths, and multiform bleb walls were also associated with higher rates of bleb success. Early bleb parameters were statistically significant predictors of bleb success up to 12 months postoperatively. Conclusions: Greater bleb height, thicker bleb walls, and lower reflectivity on ASOCT are consistently associated with successful trabeculectomy outcomes. The ASOCT may be useful in predicting bleb success and in supplementing postoperative monitoring, hence guiding timely medical or procedural interventions, to ensure long-term bleb success.
Schlemm’s Bidirectional Fluid Wave and Luminal Blood Reflux as Novel Intraoperative Signs Confirming Optimal Placement of the iStent
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate 2 novel intraoperative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies. Methods: Surgical technique report with video accompaniment. Surgical Technique: Two intraoperative clinical signs that confirm optimal iStent placement are described: (1) Luminal Blood Reflux—achieved by gently decompressing the anterior chamber, with or without flushing of the stent lumen with balanced salt solution (BSS), thereby confirming stent positioning in the Schlemm canal (SC). (2) Schlemm’s Bidirectional Fluid Wave (SBFW)—observable when flushing with BSS, suggesting fluid movement in the canal segments adjacent to the iStent device, thereby confirming stent patency and positioning in the SC. Conclusion: The identified signs are useful, feasible, and reproducible indicators of accurate iStent placement. Future studies may evaluate the application of these confirmatory maneuvers in diverse clinical contexts and further establish a correlation with clinical outcomes.
Surgery has long been an important treatment for limiting optic nerve damage and minimising visual loss in patients with glaucoma. Numerous improvements, modifications, and innovations in glaucoma surgery over recent decades have improved surgical safety, and have led to earlier and more frequent surgical intervention in glaucoma patients at risk of vision loss. This review summarises the latest advancements in trabeculectomy surgery, glaucoma drainage device (GDD) implantation, and minimally invasive glaucoma surgery (MIGS). A comprehensive search of MEDLINE, EMBASE, and CENTRAL databases, alongside subsequent hand searches—limited to the past 10 years for trabeculectomy and GDDs, and the past 5 years for MIGS—yielded 2283 results, 58 of which were included in the final review (8 trabeculectomy, 27 GDD, and 23 MIGS). Advancements in trabeculectomy are described in terms of adjunctive incisions, Tenon’s layer management, and novel suturing techniques. Advancements in GDD implantation pertain to modifications of surgical techniques and devices, novel methods to deal with postoperative complications and surgical failure, and the invention of new GDDs. Finally, the popularity of MIGS has recently promoted modifications to current surgical techniques and the development of novel MIGS devices.
Premium Intraocular Lenses in Glaucoma—A Systematic Review
The incidence of both cataract and glaucoma is increasing globally. With increasing patient expectation and improved technology, premium intraocular lenses (IOLs), including presbyopia-correcting and toric IOLs, are being increasingly implanted today. However, concerns remain regarding the use of premium IOLs, particularly presbyopia-correcting IOLs, in eyes with glaucoma. This systematic review evaluates the use of premium IOLs in glaucoma. A comprehensive search of the MEDLINE database was performed from inception until 1 June 2023. Initial search yielded 1404 records, of which 12 were included in the final review of post-operative outcomes. Studies demonstrated high spectacle independence for distance and good patient satisfaction in glaucomatous eyes, with positive outcomes also in post-operative visual acuity, residual astigmatism, and contrast sensitivity. Considerations in patient selection include anatomical and functional factors, such as the type and severity of glaucomatous visual field defects, glaucoma subtype, presence of ocular surface disease, ocular changes after glaucoma surgery, and the reliability of disease monitoring, all of which may be affected by, or influence, the outcomes of premium IOL implantation in glaucoma patients. Regular reviews on this topic are needed in order to keep up with the rapid advancements in IOL technology and glaucoma surgical treatments.