Back to Authors

Ang, Bryan Chin Hou

Mayo Clinic

National University of Singapore

Citations 2

Thirty-Six-Month Multicentre Outcomes of Combined Phacoemulsification and Hydrus Microstent Implantation in Eyes With Normal Tension Glaucoma
Ang, Bryan Chin Hou, Sim, Jackie Jia Lin , Chua, Chun Hau, Khairy, Thomas, Salimi, Ali , Harasymowycz, Paul , Ang, Bryan Chin Hou , Ang, Bryan C H , Salimi, Ali , Betzler, Bjorn Kaijun , Ramanathan, Rajesh, Hong, Ashley Shuen Ying

Journal of Glaucoma | March 26, 2026 | Volume: 35 | Issue: 6 | Pages: 369-376

10.1097/ijg.0000000000002709 Get It

Precis: This retrospective multicentre study of 77 NTG eyes undergoing phacoemulsification and Hydrus implantation showed a sustained reduction in medication burden, while maintaining IOP levels. Complications were rare and nonsight-threatening. Purpose: To evaluate 36-month outcomes of combined phacoemulsification and Hydrus Microstent implantation (Phaco-Hydrus) in eyes with normal tension glaucoma (NTG). Methods: This multicentre retrospective study included 77 NTG eyes from Singapore and Canada that underwent Phaco-Hydrus between 2014 and 2023. Primary outcomes were changes in intraocular pressure (IOP) and medication burden, and cumulative success probabilities from Kaplan-Meier (KM) analyses. Longitudinal changes were analysed using generalized estimating equations. Results: Of 77 eyes, 31 completed 36 months of follow-up. Mean baseline IOP and medications was 13.5±2.5 mm Hg and 1.7±0.9, respectively. No significant reductions in IOP were observed. A sustained reduction in medication use was observed at all follow-up timepoints ( P ≤0.001). At 36 months, medication use decreased by −0.7±0.2 [adjusted mean difference±SE of the mean [SEM]]. Proportion of medication-free eyes increased from 7.8% (n=6/77) at baseline to 45.2% (n=14/31) at 36 months. Cumulative success probabilities varied widely based on definitions. When defined as a decrease in ≥1 medication from baseline without an increase in IOP, or IOP ≤15 mm Hg and reduced ≥20% from baseline while medication-free, and no additional laser or incisional glaucoma surgery, this was 40.7% at 36 months. No visual field mean deviation progression was detected. Adverse events were infrequent and nonsight-threatening. Conclusion: In eyes with NTG, Phaco-Hydrus may offer a greater role in medication reduction or achieving a medication-free status over 36 months, rather than absolute IOP reduction.
From first generation to the next: evolution and research trends in iStent technology
Ang, Bryan Chin Hou, Wong, Natalie Shi Qi , Lim, Sheng Yang , Ang, Bryan C H , Betzler, Bjorn Kaijun

Frontiers in Medicine | January 23, 2026 | Volume: 12 | Issue: No issue available | Pages: No page available

10.3389/fmed.2025.1724886 Get It

The iStent series constitutes a range of trabecular bypass minimally invasive glaucoma surgery (MIGS) devices, which offers intraocular pressure (IOP) reduction with favourable safety profiles, in patients with open-angle glaucoma (OAG). Having undergone significant evolution since its initial US FDA-approval in 2012, successive generations address previous limitations, while enhancing IOP-lowering efficacy through device and delivery system design iterations. Longer-term and real-world iStent data demonstrate the durability of IOP- and medication-lowering outcomes with minimal complications, while preliminary studies across a wider spectrum of glaucoma subtypes and severities provide limited evidence of successful outcomes beyond mild-to-moderate OAG, both with and without concomitant cataract surgery. Aqueous humour outflow assessment and novel intra-operative techniques may further facilitate more accurate and effective iStent positioning. Despite typically higher upfront costs, results from both cost-effectiveness and patient-reported outcome studies are encouraging. Combination MIGS with the iStent, leveraging on the multiple mechanisms of actions of various procedures, may provide greater IOP-lowering efficacy without compromising safety. With expanding clinical data and progressive enhancements, iStent technology is likely to remain a key component of the evolving MIGS landscape.