Citations

Mayo Clinic

Clear

10 citation(s) found for "Xiao, Ying".

Generative AI, foundation models and large language models in radiation therapy physics: Clinical applications, challenges, and future directions
Qi, X. Sharon, Wang, Yi, Yang, Xiaofeng, Ren, Lei , Liu, Wei, Benedict, Stanley , Xiao, Ying , Xing, Lei , Naqa, Issam M. El, Qi, X. Sharon , Qi, X. Sharon, Yang, Xiaofeng

Medical Physics | August 7, 2026 | Volume: 53 | Issue: 8 | Pages: No page available

10.1002/mp.70616 | PMID 42563397 Get It

Abstract Generative AI (Gen AI), Foundation Models (FMs), and Large Language Models (LLMs) are powerful emerging technologies that demonstrate exceptional capabilities in processing vast amounts of unstructured and structured data, including text, voice, images, video and other formats, and adapting to a wide range of specific tasks. Their immense potential to drive meaningful improvements in treatment outcomes is increasingly evident. The advent of these technologies has marked a transformative era in healthcare, including the fields of radiation oncology and medical physics. Specifically, these powerful technologies offer unprecedented opportunities to analyze domain‐specific data, process and synthesize medical images, automate routine tasks, support clinical decision‐making, optimize and streamline clinical workflows, and enhance the quality of clinical trials. While these emerging technologies present new opportunities to revolutionize radiation therapy practice, their implementation also raises important educational, ethical, and regulatory considerations. This scoping review highlights benefits, promises, risks, and challenges, such as interpretability, data privacy, regulatory compliance, reproducibility, hallucination, and integration into existing clinical workflow. Finally, emerging opportunities are outlined to guide future research directions. This review paper provides a timely overview of Gen AI, FMs and LLMs, aiming to inform medical physicists, clinicians, and researchers of the evolving role of these disruptive technologies in shaping the future of radiation therapy.
NRG-GY037: A phase III randomized trial of induction chemotherapy and pembrolizumab followed by chemoradiation and pembrolizumab maintenance versus standard chemoradiation and pembrolizumab maintenance in high-risk locally advanced cervical cancer.
Mayadev, Jyoti, Deng, Wei , Kim, Hayeon, Xiao, Ying, Geng, H. , Myers, Tashanna , Garda, Allison Elizabeth, Ayala-Peacock, Diandra Norelle, Ma, Martín, Matulonis, Ursula A., Kuhn, Theresa, Huelsmann, Erica, Mannel, Robert S., Herzog, Thomas J. , Aghajanian, Carol, III, Charles A. Leath, Zamarin, Dmitriy, Lankes, Heather A. , Lea, Jayanthi Sivasothy , Xiao, Ying, Garda, Allison E. , Ayala-Peacock, Diandra N. , Matulonis, Ursula A. , Kuhn, Theresa M , Huelsmann, Erica J., Aghajanian, Carol , Zamarin, Dmitriy

Journal of Clinical Oncology | May 28, 2026 | Volume: 44 | Issue: 16_suppl | Pages: No page available

10.1200/jco.2026.44.16_suppl.tps5632 Get It

TPS5632 Background: Concurrent chemoradiation therapy (CCRT) is the standard of care for locally advanced cervical cancer (LACC); however, outcomes remain suboptimal in patients with high-risk disease. Recent studies suggest that integration of immunotherapy (IO) with definitive chemoradiation, or induction chemotherapy prior to CCRT improves outcomes. Whether treatment intensification with induction systemic therapy and IO prior to CCRT and IO further improves disease control remains unknown. Induction chemotherapy may reduce tumor burden, eradicate micrometastatic disease, and improve tumor immunogenicity prior to definitive CCRT. Preclinical and clinical data support synergy between systemic therapy or radiotherapy and immune checkpoint blockade, providing the rationale for evaluating an induction strategy incorporating chemotherapy and immunotherapy before standard CCRT with immunotherapy, followed by maintenance immunotherapy. Optional tumor tissue and blood samples will be collected for exploratory correlative analyses, including immune and molecular biomarkers associated with response, resistance, and patterns of failure. Methods: NRG-GY037 is a prospective, multi-institutional phase III randomized trial conducted through NRG Oncology. A total of 336 patients will be enrolled (168 per arm). Patients will be stratified by FIGO stage (III vs. IVA) and presence or absence of para-aortic lymph nodes (N2). The primary endpoint is progression free survival (PFS). The study has 90% power to detect PFS hazard ratio of 0.65 in the experimental arm. Treatment: Patients with previously untreated, high-risk LACC are randomized to receive either induction chemotherapy with pembrolizumab for 6 weeks followed by CCRT with pembrolizumab and pembrolizumab maintenance, or standard CCRT with pembrolizumab followed by pembrolizumab maintenance. Major Eligibility Criteria: Eligible patients have histologically confirmed cervical carcinoma (squamous, adenocarcinoma, or adenosquamous), TNM T3 and T4 disease, N0-2, ECOG performance status 0–1, and no prior definitive therapy for cervical cancer. Current Enrollment Status: The trial is actively accruing patients. No efficacy or safety data are available at the time of submission. Clinical Trial Registration: ClinicalTrials.gov identifier: NCT07061977. Clinical trial information: NCT07061977 .
Angle-Free Ultrasound-assisted Technique for Difficult Lumbar Puncture to Enhance Precision and Success in Complex Spinal Anatomy: A Case Series with Longitudinal Learning Curve Analysis
Wang, Xuan, Luo, Yijun , Huang, Chanyan, Lu, Xiaolin , Diedrich, Daniel A. , Xiao, Ying , Wang, Xuan, Zhang, Xiaolong, Huang, Chanyan , Xiao, Ying

No container title available | March 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-8901033/v1 Get It

Abstract Background Lumbar puncture is a routinely performed procedure, yet it presents significant challenges in patients with abnormal spinal anatomy, such as severe scoliosis or obesity. Conventional ultrasound-assisted neuraxial techniques, while superior to landmark-based methods, are constrained by two fundamental limitations: inaccurate projection of the probe’s geometric center onto the skin when the probe is tilted or rocked, and the difficulty of consistently replicating the exact probe angle during needle insertion. These limitations contribute to multiple needle passes, prolonged procedure time, and increased patient discomfort and complication risk. To address these issues, we developed a novel angle-free ultrasound-assisted technique designed to eliminate the need for replicating probe angulation during needle insertion. Case presentation: This angle-free approach was utilized for serial lumbar punctures in two patients with spinal muscular atrophy requiring repeated intrathecal nusinersen administration. Both patients presented with extreme anatomical complexity, including high body mass index (30 and 35.1 kg/m²) and severe scoliosis (Cobb angles 90° and 83°). The technique follows a three-step protocol: (1) Preprocedural imaging to select the optimal interlaminar space; (2) Ultrasound-guided postural adjustment until the probe could be held perpendicular to the bed edge and parallel to the floor while maintaining target visualization; (3) Needle insertion along this orthogonal trajectory. All 22 procedures (11 per patient) were completed successfully without persistent neurological complications. Procedural outcomes demonstrated a first-attempt success rate of 81.8% (Case 1) and 100% (Case 2), with first-pass success rates of 45.5% and 54.5%, respectively. Longitudinal analysis across sequential procedures revealed a consistent reduction in both the number of needle passes and needling time, reflecting a favorable learning curve. Conclusions The angle-free ultrasound-assisted neuraxial technique offers a valuable alternative for patients with complex spinal anatomy. By using real-time postural adjustments to achieve a needle trajectory, it enhances procedural precision and eliminates the technical hurdle of replicating probe angulation. The structured "4P" framework (Planning, Positioning, Perpendicular, Parallel) offers a practical guide for clinical adoption. The observed learning curve suggests that clinicians can readily acquire and apply this technique to manage such challenging cases.
NRG Oncology Liver Proton SBRT and Hypofractionated Radiation Therapy: Current Treatment Technical Assessment and Practice Patterns
Kang, Minglei , Taylor, Paige A. , Shen, Jiajian , Saini, Jatinder, Hong, Theodore S. , Liu, Wei , Xiao, Ying , Simone, Charles B. , Lin, Liyong , Liu, Wei , Xiao, Ying , Simone, Charles B , Lin, Liyong , Taylor, Paige , Shen, Jiajian , Zhou, Jun , Higgins, Kristin Ann

Cancers | July 17, 2025 | Volume: 17 | Issue: 14 | Pages: 2369

10.3390/cancers17142369 | PMID 40723252 Get It

Background/Objectives: Proton therapy delivers highly conformal doses to the target area without producing an exit dose, minimizing cumulative doses to healthy liver tissue. This study aims to evaluate current practices, challenges, and variations in the implementation of proton stereotactic body radiation therapy (SBRT) and hypofractionated therapy for liver malignancies, with the goal of providing a technical assessment to promote broader adoption and support future clinical trials. Methods and Materials: An extensive survey was conducted by NRG Oncology across North American proton treatment centers to assess the current practices of proton liver SBRT and hypofractionated therapy. The survey focused on key aspects, including patient selection, prescription and normal tissue constraints, simulation and motion management, treatment planning, quality assurance (QA), treatment delivery, and the use of image-guided radiation therapy (IGRT). Results: This survey captures the current practice patterns and status of proton SBRT and hypofractionated therapy in liver cancer treatment. Proton therapy is increasingly preferred for treating inoperable liver malignancies due to its ability to minimize healthy tissue exposure. However, the precision required for proton therapy presents challenges, particularly in managing uncertainties and target motion during high-dose fractions and short treatment courses. Survey findings revealed significant variability in clinical practices across centers, highlighting differences in motion management, dose fractionation schedules, and QA protocols. Conclusion: Proton SBRT and hypofractionated therapy offer significant potential for treating liver malignancies. A comprehensive approach involving precise patient selection, treatment planning, and QA is essential for ensuring safety and effectiveness. This survey provides valuable insights into current practices and challenges, offering a foundation for technical recommendations to optimize the use of proton therapy and guide future clinical trials.
ACR-ACNM-ASTRO-SNMMI Practice Parameter for Lutetium-177 (Lu-177) DOTATATE Therapy
Love, Charito , Desai, Neil , Abraham, Tony, Banks, Kevin , Bodei, Lisa , Boike, Thomas, Brown, Richard K., Bushnell, David , DeBlanche, Lorraine E., Dominello, M.M., Francis, Tony, Grady, Erin C., Kempf, Jeffrey , Pryma, Daniel A. , Rule, William G., Savir-Baruch, Bital , Sethi, Ila, Subramaniam, Rathan M. , Xiao, Ying , Schechter, Naomi R., Rule, William, Bodei, Lisa , Abraham, Tony, Hobbs, Robert F , Hope, Thomas A.

American Journal of Clinical Oncology | May 4, 2022 | Volume: 45 | Issue: 6 | Pages: 233-242

10.1097/coc.0000000000000903 | PMID 35507413 Get It

Objectives: This practice parameter (PP) for Lutetium-177 (Lu-177) DOTATATE peptide receptor radionuclide therapy (PRRT) aims to guide authorized users in selection of appropriate adult candidates with gastroeneropancreatic neuroendocrine tumors (GEP-NETs) from foregut, midgut, and hindgut. The essential selection criteria include somatostatin receptor-positive GEP-NETs, which are usually inoperable and progressed despite standard therapy. Lu-177 DOTATATE is a radiopharmaceutical with high avidity for somatostatin receptors that are overexpressed by these tumors. This document ensures safe handling of Lu-177 DOTATATE by the authorized users and safe management of affected patients. Methods: The document was developed according to the systematic process developed by the American College of Radiology (ACR) and described on the ACR Web site (https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards). The PP development was led by 2 ACR Committees on Practice Parameters (Nuclear Medicine and Molecular Imaging and Radiation Oncology) collaboratively with the American College of Nuclear Medicine, American Society of Radiation Oncology, and Society of Nuclear Medicine and Molecular Imaging. Results: The Lu-177 DOTATATE PP reviewed pharmacology, indications, adverse effects, personnel qualifications, and required clinical evaluation before starting the treatment, as well as the recommended posttherapy monitoring, quality assurance, documentation, and appropriate radiation safety instructions provided in written form and explained to the patients. Conclusions: Lu-177 DOTATATE is available for therapy of inoperable and/or advanced GEP-NETs when conventional therapy had failed. It can reduce tumor size, improve symptoms, and increase the progression free survival. The PP document provides clinical guidance for authorized users to assure an appropriate, consistent, and safe practice of Lu-177 DOTATATE.
ACR-ACNM-ASTRO-SNMMI Practice Parameter for Lutetium-177 (Lu-177) DOTATATE Therapy
Love, Charito , Desai, Neil , Abraham, Tony, Banks, Kevin , Bodei, Lisa , Boike, Thomas, Brown, Richard K., Bushnell, David , DeBlanche, Lorraine E., Dominello, M.M., Francis, Tony, Grady, Erin C., Kempf, Jeffrey , Pryma, Daniel A. , Rule, William G., Savir-Baruch, Bital , Sethi, Ila, Subramaniam, Rathan M. , Xiao, Ying , Schechter, Naomi R., Rule, William, Bodei, Lisa , Abraham, Tony, Hobbs, Robert F , Hope, Thomas A.

Clinical Nuclear Medicine | May 4, 2022 | Volume: 47 | Issue: 6 | Pages: 503-511

10.1097/rlu.0000000000004182 | PMID 35507433 Get It

Objectives This practice parameter (PP) for Lutetium-177 (Lu-177) DOTATATE peptide receptor radionuclide therapy (PRRT) aims to guide authorized users in selection of appropriate adult candidates with gastroeneropancreatic neuroendocrine tumors (GEP-NETs) from foregut, midgut, and hindgut. The essential selection criteria include somatostatin receptor-positive GEP-NETs, which are usually inoperable and progressed despite standard therapy. Lu-177 DOTATATE is a radiopharmaceutical with high avidity for somatostatin receptors that are overexpressed by these tumors. This document ensures safe handling of Lu-177 DOTATATE by the authorized users and safe management of affected patients. Methods The document was developed according to the systematic process developed by the American College of Radiology (ACR) and described on the ACR Web site (https://www.acr.org/Clinical-Resources/Practice-Parameters-and-Technical-Standards). The PP development was led by 2 ACR Committees on Practice Parameters (Nuclear Medicine and Molecular Imaging and Radiation Oncology) collaboratively with the American College of Nuclear Medicine, American Society of Radiation Oncology, and Society of Nuclear Medicine and Molecular Imaging. Results The Lu-177 DOTATATE PP reviewed pharmacology, indications, adverse effects, personnel qualifications, and required clinical evaluation before starting the treatment, as well as the recommended posttherapy monitoring, quality assurance, documentation, and appropriate radiation safety instructions provided in written form and explained to the patients. Conclusions Lu-177 DOTATATE is available for therapy of inoperable and/or advanced GEP-NETs when conventional therapy had failed. It can reduce tumor size, improve symptoms, and increase the progression free survival. The PP document provides clinical guidance for authorized users to assure an appropriate, consistent, and safe practice of Lu-177 DOTATATE.
Higher Radiation Dose to the Immune Cells Correlates with Worse Tumor Control and Overall Survival in Patients with Stage III NSCLC: A Secondary Analysis of RTOG0617
Jin, Jian‐Yue , Hu, Chen , Xiao, Ying , Ellsworth, Susannah G. , Bogart, Jeffrey A. , Dobelbower, M.C., Kavadi, Vivek S. , Narayan, Samir , Iyengar, Puneeth , Robinson, Clifford G. , Koprowski, Christopher D. , Machtay, Mitchell , Curran, Walter J. , Choy, Hak, Bradley, Jeffrey D. , Kong, Feng‐Ming , Schild, Steven E. , Kong, Feng-Ming Spring , Robinson, Clifford , Bradley, Jeffrey , Zhang, Hong , Paulus, Rebecca , Greenberger, Joel S

Cancers | December 8, 2021 | Volume: 13 | Issue: 24 | Pages: 6193

10.3390/cancers13246193 | PMID 34944813 Get It

Background: We hypothesized that the Effective radiation Dose to the Immune Cells (EDIC) in circulating blood is a significant factor for the treatment outcome in patients with locally advanced non-small-cell lung cancer (NSCLC). Methods: This is a secondary study of a phase III trial, NRG/RTOG 0617, in patients with stage III NSCLC treated with radiation-based treatment. The EDIC was computed as equivalent uniform dose to the entire blood based on radiation doses to all blood-containing organs, with consideration of blood flow and fractionation effect. The primary endpoint was overall survival (OS), and the secondary endpoints were progression-free survival (PFS) and local progression-free survival (LPFS). The EDIC–survival relationship was analyzed with consideration of clinical significant factors. Results: A total of 456 patients were eligible. The median EDIC values were 5.6 Gy (range, 2.1–12.2 Gy) and 6.3 Gy (2.1–11.6 Gy) for the low- and high-dose groups, respectively. The EDIC was significantly associated with OS (hazard ratio [HR] = 1.12, p = 0.005) and LPFS (HR = 1.09, p = 0.02) but PFS (HR = 1.05, p = 0.17) after adjustment for tumor dose, gross tumor volume and other factors. OS decreased with an increasing EDIC in a non-linear pattern: the two-year OS decreased first with a slope of 8%/Gy when the EDIC < 6 Gy, remained relatively unchanged when the EDIC was 6–8 Gy, and followed by a further reduction with a slope of 12%/Gy when the EDIC > 8 Gy. Conclusions: The EDIC is a significant independent risk factor for poor OS and LPFS in RTOG 0617 patients with stage III NSCLC, suggesting that radiation dose to circulating immune cells is critical for tumor control. Organ at risk for the immune system should be considered during RT plan.
ACR-ACNM-ASTRO-SNMMI Practice Parameter for the Performance of Therapy With Radium-223
Hurwitz, Mark , Buscombe, John, Jacene, Heather A. , Klitzke, Alan, Lamonica, Dominick , Lu, Yang, Pryma, Daniel A. , Rohren, Eric , Speer, Tod W., Subramaniam, Rathan M. , Thompson, Holly M. , Tomblyn, Michael, Wong, William W. , Xiao, Ying , Banks, Kevin , Brown, Richard K., Lü, Yang

American Journal of Clinical Oncology | June 10, 2020 | Volume: 43 | Issue: 8 | Pages: 539-544

10.1097/coc.0000000000000702 | PMID 32520788 Get It

Aim/Objectives/Background: The goal of therapy with unsealed radiopharmaceutical sources is to provide either cure or significant prolongation of disease-specific survival, and effective reduction and/or prevention of adverse disease-related symptoms or untoward events while minimizing treatment-associated side effects and complications. Radium-223 dichloride (radium-223) is an alpha particle–emitting isotope used for targeted bone therapy. This practice parameter is intended to guide appropriately trained and licensed physicians performing therapy with radium-223. Such therapy requires close cooperation and communication between the physicians who are responsible for the clinical management of the patient and those who administer radiopharmaceutical therapy and manage the attendant side effects. Adherence to this parameter should help to maximize the efficacious use of radium-223, maintain safe conditions, and ensure compliance with applicable regulations. Methods: This practice parameter was developed according to the process described on the American College of Radiology (ACR) website (“The Process for Developing ACR Practice Parameters and Technical Standards,” www.acr.org/ClinicalResources/Practice-Parameters-and-Technical-Standards) by the Committee on Practice Parameters of the ACR Commission on Radiation Oncology in collaboration with the American College of Nuclear Medicine (ACNM), the American Society for Radiation Oncology (ASTRO), and the Society of Nuclear Medicine and Molecular Imaging (SNMMI). All these societies contributed to the development of the practice parameter and approved the final document. Results: This practice parameter addresses the many factors which contribute to appropriate, safe, and effective clinical use of radium-223. Topics addressed include qualifications and responsibilities of personnel, specifications of patient examination and treatment; documentation, radiation safety, quality control/improvement, infection control, and patient education. Conclusions: This practice parameter is intended as a tool to guide clinical use of radium-223 with the goal of facilitating safe and effective medical care based on current knowledge, available resources and patient needs. The sole purpose of this document is to assist practitioners in achieving this objective.
Modeling the Impact of Cardiopulmonary Irradiation on Overall Survival in NRG Oncology Trial RTOG 0617
Thor, Maria, Deasy, Joseph O. , Hu, Chen , Gore, Elizabeth , Bar‐Ad, Voichita , Robinson, Clifford G. , Wheatley, Matthew , Oh, Jung Hun , Bogart, Jeffrey A. , Garces, Yolanda I. , Kavadi, Vivek S. , Narayan, Samir , Iyengar, Puneeth , Witt, Jacob S. , Welsh, James W. , Koprowski, Cristopher D., Larner, James M. , Xiao, Ying , Bradley, Jeffrey D. , Robinson, Clifford , Bradley, Jeffrey

Clinical Cancer Research | May 12, 2020 | Volume: 26 | Issue: 17 | Pages: 4643-4650

10.1158/1078-0432.ccr-19-2627 | PMID 32398326 Get It

Abstract Purpose: To quantitatively predict the impact of cardiopulmonary dose on overall survival (OS) after radiotherapy for locally advanced non–small cell lung cancer. Experimental Design: We used the NRG Oncology/RTOG 0617 dataset. The model building procedure was preregistered on a public website. Patients were split between a training and a set-aside validation subset (N = 306/131). The 191 candidate variables covered disease, patient, treatment, and dose-volume characteristics from multiple cardiopulmonary substructures (atria, lung, pericardium, and ventricles), including the minimum dose to the hottest x% volume (Dx%[Gy]), mean dose of the hottest x% (MOHx%[Gy]), and minimum, mean (Mean[Gy]), and maximum dose. The model building was based on Cox regression and given 191 candidate variables; a Bonferroni-corrected P value threshold of 0.0003 was used to identify predictors. To reduce overreliance on the most highly correlated variables, stepwise multivariable analysis (MVA) was repeated on 1000 bootstrapped replicates. Multivariate sets selected in ≥10% of replicates were fit to the training subset and then averaged to generate a final model. In the validation subset, discrimination was assessed using Harrell c-index, and calibration was tested using risk group stratification. Results: Four MVA models were identified on bootstrap. The averaged model included atria D45%[Gy], lung Mean[Gy], pericardium MOH55%[Gy], and ventricles MOH5%[Gy]. This model had excellent performance predicting OS in the validation subset (c = 0.89). Conclusions: The risk of death due to cardiopulmonary irradiation was accurately modeled, as demonstrated by predictions on the validation subset, and provides guidance on the delivery of safe thoracic radiotherapy.
Treatment data and technical process challenges for practical big data efforts in radiation oncology
Mayo, C., Phillips, Mark H., McNutt, TR, Palta, Jatinder , Dekker, André , Miller, Robert C. , Xiao, Ying , Moran, Jean M. , Matuszak, M.M. , Ayan, AS, Prisciandaro, Joann I. , Thor, Maria, Dixit, Niharika , Killoran, Joseph H., Kaleba, Erin O., Kantor, Michael , Kapoor, Rishabh , Kessler, ML, Lawrence, Theodore S. , Mayo, Charles S. , Lawrence, Theodore S , Gabriel, Peter , Popple, Richard A. , Ruan, Dan

Medical Physics | September 18, 2018 | Volume: 45 | Issue: 10 | Pages: No page available

10.1002/mp.13114 | PMID 30226286 Get It

The term Big Data has come to encompass a number of concepts and uses within medicine. This paper lays out the relevance and application of large collections of data in the radiation oncology community. We describe the potential importance and uses in clinical practice. The important concepts are then described and how they have been or could be implemented are discussed. Impediments to progress in the collection and use of sufficient quantities of data are also described. Finally, recommendations for how the community can move forward to achieve the potential of big data in radiation oncology are provided.