Objectives: This study evaluates the efficacy of existing and new aerosol mitigation methods during nebulization (Neb) in combination with high-flow nasal cannula (HFNC) oxygen supplementation and non-invasive ventilation (NIV). Methods: We recorded fugitive aerosol particle concentrations over time and assessed the peak (P) and area (A) efficacy of active and passive mitigation methods, comparing them to a no-mitigation condition. Peak efficacy was measured by the reduction in maximum aerosol concentration, while area efficacy was quantified by the reduction of the area under the aerosol concentration–time curve. Results: For HFNC with Neb, we found that active mitigation using a mask with a biofilter and a fan (referred to as the aerosol barrier mask) significantly outperformed passive mitigation with a face mask. The peak and area efficacy for aerosol reduction were 99.0% and 96.4% for active mitigation and 35.9% and 7.6% for passive mitigation, respectively. For NIV with Neb, the active mitigation method, using a box with a biofilter and fan, also outperformed passive mitigation using only the box. The peak and area efficacy for aerosol reduction were 92.1% and 85.5% for active mitigation and 53.7.0% and 25.4% for passive mitigation, respectively. Conclusion: We concluded that active mitigation set up systems advantageous for effective reduction of airborne aerosols during aerosol generated procedures.
Ketones are well-known biomarkers of fat oxidation produced in the liver as a result of lipolysis. These biomarkers include acetoacetic acid and β-hydroxybutyric acid in the blood/urine and acetone in our breath and skin. Monitoring ketone production in the body is essential for people who use caloric intake deficit to reduce body weight or use ketogenic diets for wellness or therapeutic treatments. Current methods to monitor ketones include urine dipsticks, capillary blood monitors, and breath analyzers. However, these existing methods have certain disadvantages that preclude them from being used more widely. In this work, we introduce a novel acetone sensor device that can detect acetone levels in breath and overcome the drawbacks of existing sensing approaches. The critical element of the device is a robust sensor with the capability to measure acetone using a complementary metal oxide semiconductor (CMOS) chip and convenient data analysis from a red, green, and blue deconvolution imaging approach. The acetone sensor device demonstrated sensitivity of detection in the micromolar-concentration range, selectivity for detection of acetone in breath, and a lifetime stability of at least one month. The sensor device utility was probed with real tests on breath samples using an established blood ketone reference method.
Self-contained system for mitigation of contaminated aerosol sources of SARS-CoV-2
Abstract Contaminated aerosols and micro droplets are easily generated by infected hosts through sneezing, coughing, speaking and breathing1-3 and harm humans’ health and the global economy. While most of the efforts are usually targeted towards protecting individuals from getting infected,4 eliminating transmissions from infection sources is also important to prevent disease transmission. Supportive therapies for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) pneumonia such as oxygen supplementation, nebulizers and non-invasive mechanical ventilation all carry an increased risk for viral transmission via aerosol to healthcare workers.5-9 In this work, we study the efficacy of five methods for self-containing aerosols emitted from infected subjects undergoing nebulization therapies with a diverse spectrum on oxygen delivery therapies. The work includes five study cases: Case I: Use of a Full-Face Mask with biofilter in bilevel positive airway pressure device (BPAP) therapy, Case II: Use of surgical mask in High Flow Nasal Cannula (HFNC) therapy, Case III: Use of a modified silicone disposable mask in a HFNC therapy, Case IV: Use of a modified silicone disposable mask with a regular nebulizer and normal breathing, Case V: Use of a mitigation box with biofilter in a Non-Invasive Positive Pressure Ventilator (NIPPV). We demonstrate that while cases I, III and IV showed efficacies of 98-100%; cases II and V, which are the most commonly used, resulted with significantly lower efficacies of 10-24% to mitigate the dispersion of nebulization aerosols. Therefore, implementing cases I, III and IV in health care facilities may help battle the contaminations and infections via aerosol transmission during a pandemic.
Evaluation of a Thermal-Based Flow Meter for Assessment of Mobile Resting Metabolic Rate Measures
This work evaluates the use of a new flow meter to assess exhalation rate. A mobile indirect calorimeter (MIC) was designed and used to measure resting metabolic rate (RMR), which relies on the measure of O2 consumption rate (VO2) and CO2 production rate (VCO2). The device was produced from a commercially available and well-established indirect calorimeter and implemented with a new flow meter for the purpose of this study. VO2 and VCO2 were assessed by measuring exhalation rates using the new flow meter and O2 and CO2 concentrations in breath using the original colorimetric sensors of the indirect calorimeter. The new flow meter was based on a thermal flow meter (TFM) affixed to an orifice with a diameter of 6.8 mm used as a passage for exhaled breath from 16 subjects. The results were compared with a metabolic cart (Medical Graphics), which was connected in series to the modified device. We found that 69% of the results had more than a 10% difference between the modified MIC device and the reference instrument, suggesting that the sensitivity of the thermal flow meter changed over time, which precluded its use as a flow meter for breath flow rate measurement.