Citations

Mayo Clinic

Clear

4 citation(s) found for "Eifert-Rain, Susan".

Prognostic Utility of Stress Testing and Cardiac Biomarkers in Menopausal Women at Low to Intermediate Risk for Coronary ARTery Disease (SMART Study): 5-Year Outcome
Ball, Caroline , Hagen, Mary E., Eifert-Rain, Susan, Wilansky, Susan , Castelló, Ramón, Pellikka, Patricia A. , Best, Patricia J.M. , Abdelmoneim, Sahar S. , Ball, Caroline A, Mantovani, Francesca , Pellikka, Patricia A , Mulvagh, Sharon L.

Journal of Women's Health | April 19, 2018 | Volume: 27 | Issue: 5 | Pages: 542-551

10.1089/jwh.2017.6506 | PMID 29672210 Get It

Background: In women with low to intermediate risk of coronary artery disease (CAD), prognostic detection strategies have been controversial. We present the follow-up data of the SMART trial in peri/postmenopausal women at low to intermediate risk of CAD. Objectives: To determine the value of contrast stress echocardiography (CSE), stress electrocardiogram (sECG), and serum biomarkers for prediction of cardiovascular events (CE) in peri/postmenopausal women at low to intermediate risk of CAD. Materials and Methods: From January 2004 to August 2007, 400 peri/postmenopausal women were prospectively enrolled. All women had detailed risk factor assessment, and underwent simultaneous CSE (Definity ® , Lantheus Medical Imaging) and sECG. Laboratories included brain natriuretic peptide (BNP), atrial natriuretic peptide, endothelin, and high sensitivity C-reactive protein. Wall motion score index was based on a 16-segment model. Abnormal CSE was defined as new or worsening wall motion abnormality at stress, while abnormal sECG was ≥1 mm horizontal/downsloping ST segment depression/elevation (80 mseconds duration). Self-reported outcome data were collected from a mailed Women's Heart Clinic Questionnaire. CE outcomes included all-cause mortality, nonfatal myocardial infarction (MI), heart failure, chest pain hospitalization or development of typical angina (CP), and revascularization (REVASC). Adjusted Cox proportional hazard ratios (HR; 95% confidence intervals) were reported. Results: A total of 366 women (54.4 ± 5.5 years, Framingham risk 6.5% ± 4.4%) completed simultaneous CSE and sECG. Forty-two (11.5%) had abnormal CSE, while sECG was abnormal in 22 (6%) women. Follow-up (4.4 ± 1.2 years) was available in 315/366 (86%) women (78% exercise-CSE, 22% dobutamine-CSE). In those who completed follow-up, CSE was abnormal in 33 women (10.5%) and sECG was abnormal in 21 (6.7%). In 33 women with abnormal CSE, sECG was abnormal in 7 (21.2%) and normal in 26 (79%), p = 0.0004. CE occurred in 27 (8.6%) women: 8 all-cause mortality, 2 nonfatal MI, 13 CP, and 4 REVASC. CE occurred in 21% versus 7% of women with abnormal versus normal CSE, p = 0.014 and 38% versus 6% of women with abnormal versus normal sECG, p < 0.0001. Rest BNP was higher in women with CE versus those without ( p = 0.018). Abnormal sECG and abnormal CSE were associated with CE, while only abnormal sECG was an independent predictor of CE (adjusted HR 10.3 [1.9–61.4], p = 0.007). Of the laboratory results, only BNP was associated with CE (adjusted HR 2.9 [1.1–7.3], p = 0.028). Conclusions: sECG and rest BNP were independent predictors of subsequent CE within 5 years in peri/postmenopausal women at low to intermediate risk of CAD.
CUTE‐CV: A Prospective Study of Enhanced Left Atrial Appendage Visualization with Microbubble Contrast Agent Use during Transesophageal Echocardiography Guided Cardioversion
Bernier, Mathieu , Moir, William, Rain, Susan J. Eifert, Chandrasekaran, Krishnaswamy , Ammash, Naser M., Abdelmoneim, Sahar S. , Mulvagh, Sharon L.

Echocardiography | May 11, 2013 | Volume: 30 | Issue: 9 | Pages: 1091-1097

10.1111/echo.12240 | PMID 23662846 Get It

ObjectivesThe aim of our study was to demonstrate that the use of contrast microbubbles during transesophageal echocardiography (TEE) guided cardioversion will improve interpretation of the TEE images.BackgroundTEE‐guided cardioversion of atrial flutter or fibrillation (AF) is a safe and proven method to restore sinus rhythm. However, artifacts and dense spontaneous echo contrast in the left atrial appendage (LAA) can sometimes decrease the level of confidence in excluding the presence of thrombus.MethodsOne hundred patients referred for TEE‐guided cardioversion were prospectively enrolled and microbubble contrast agent (DEFINITY) was administered after the clinical decision had been made regarding suitability for cardioversion. Noncontrast and contrast images were compared during subsequent offline analysis.ResultsLAA dimensions and contractility indices were higher, artifacts were significantly differentiated, previously unsuspected LAA filling defects were identified, and the level of confidence in excluding thrombus was enhanced in the contrast images when compared to the noncontrast images. After 4 months follow‐up, 1 stroke‐associated death occurred in a patient who had LAA thrombus recognized only by contrast. Left atrial appendage visualization is enhanced with microbubble contrast agent use during transesophageal echocardiography guided cardioversion and is useful in identification of intracardiac thrombus.
A Multicenter, Prospective Study to Evaluate the Use of Contrast Stress Echocardiography in Early Menopausal Women at Risk for Coronary Artery Disease: Trial Design and Baseline Findings
Bernier, Mathieu , Hagen, Mary E., Eifert-Rain, Susan, Bott‐Kitslaar, Dalene , Wilansky, Susan , Castelló, Ramón, Bhat, Gajanan , Pellikka, Patricia A. , Best, Patricia J.M. , Hayes, Sharonne N. , Abdelmoneim, Sahar S. , Mulvagh, Sharon L. , Pellikka, Patricia A , Hayes, Sharonne N

Journal of Women's Health | February 11, 2013 | Volume: 22 | Issue: 2 | Pages: 173-183

10.1089/jwh.2012.3714 | PMID 23398128 Get It

Rapid Detection of Coronary Artery Stenoses With Real-Time Perfusion Echocardiography During Regadenoson Stress
Porter, Thomas R. , Adolphson, Mary, High, Robin , Olson, Joan, Erdkamp, Michelle, Xie, Feng , O’Leary, Edward , Wong, Benjamin F., Eifert-Rain, Susan, Hagen, Mary E., Abdelmoneim, Sahar S. , Smith, Lynette M. , Mulvagh, Sharon L.

Circulation: Cardiovascular Imaging | September 24, 2011 | Volume: 4 | Issue: 6 | Pages: 628-635

10.1161/circimaging.111.966341 | PMID 21946702 Get It

Background— Real-time myocardial contrast echocardiography permits the detection of myocardial perfusion abnormalities during stress echocardiography, which may improve the accuracy of the test in detecting coronary artery stenoses. We hypothesized that this technique could be used after a bolus injection of the selective A2A receptor agonist regadenoson to rapidly and safely detect coronary artery stenoses. Methods and Results— In 100 patients referred for quantitative coronary angiography, real-time myocardial contrast echocardiography was performed during a continuous intravenous infusion of 3% Definity at baseline and at 2-minute intervals for up to 6 minutes after a regadenoson bolus injection (400 μg). Myocardial perfusion was assessed by examination of myocardial contrast replenishment after brief high mechanical index impulses. A perfusion defect was defined as a delay (>2 seconds) in myocardial contrast replenishment in 2 contiguous segments. Wall motion was also analyzed. The overall sensitivity/specificity/accuracy for myocardial perfusion analysis in detecting a >50% diameter stenosis was 80%/74%/78%, whereas for wall motion analysis it was 60%/72%/66% ( P <0.001 for differences in sensitivity). Sensitivity for myocardial perfusion analysis was highest on images obtained during the first 2 minutes after regadenoson bolus ( P <0.001 compared with wall motion), whereas wall motion sensitivity was highest at the 4-to-6–minute period after the bolus. No significant side effects occurred after regadenoson bolus injection. Conclusions— Regadenoson real-time myocardial contrast echocardiography appears to be a feasible, safe, and rapid noninvasive method for the detection of significant coronary artery stenoses. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT0087369.