Citations

Mayo Clinic

Clear

2357 citation(s) found for "K, Long".

Purified Exosome Product Enhances Chondrocyte Survival and Regeneration by Modulating Inflammation and Promoting Chondrogenesis
Shi, Guidong , Long, Zeling , Moran, Steven L. , Evans, Christopher H. , Zhao, Chunfeng , Evans, Christopher, Shi, Guidong , Vega, Rodolfo E. De la , Behfar, Atta

Regenerative Medicine | October 18, 2022 | Volume: 18 | Issue: 1 | Pages: 55-71

10.2217/rme-2022-0132 | PMID 36255073 Get It

Response to Mansoor et al : ‘epidemiology of inflammatory bowel disease in men with high-risk homosexual activity’
Newman, Kira L. , Jencks, Kara J. , Chedid, Victor , Paul, Sonali , Higgins, Peter D R , Kane, Sunanda V. , Long, Millie D. , Chedid, Victor G , Jencks, Kara , Newman, Kira L

Gut | October 13, 2022 | Volume: 72 | Issue: 10 | Pages: 2003-2004

10.1136/gutjnl-2022-328802 | PMID 36229171 Get It

Long-term outcomes for patients with Hodgkin lymphoma at increased risk of progression or relapse
Kosydar, Samuel , Ansell, Stephen M. , Kosydar, Samuel R

Leukemia & Lymphoma | October 10, 2022 | Volume: 64 | Issue: 1 | Pages: 5-17

10.1080/10428194.2022.2131422 | PMID 36215148 Get It

Faculty Opinions recommendation of Directed evolution of adeno-associated virus for efficient gene delivery to microglia.
Bosco, Dale B. , Wu, Long‐Jun

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | October 10, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.742251078.793595809 Get It

Ultrasound‐guided injection of the long head of the biceps tendon sheath with concomitant subacromial bursa injection through the same needlestick
Pujalte, George G.A. , Hudspeth, Loren J., Troyer, Wesley , Pujalte, George , Troyer, Wesley D, Shapiro, Shane A.

Clinical Anatomy | October 10, 2022 | Volume: 36 | Issue: 3 | Pages: 400-405

10.1002/ca.23961 | PMID 36210353 Get It

AbstractSonography and specific shoulder positions allow for injections into both the long head of the biceps tendon sheath (LHBTS) and the subacromial space (SS) with one needlestick. We validated this technique using cadavers. An experienced proceduralist injected latex solution into 12 unembalmed cadaveric shoulders, aiming for the LHBTS and SS, using an ultrasound‐guided injection technique that employs a single‐needle entry point. An experienced surgeon dissected each specimen and graded latex location as: (1) completely accurate (in both the SS and LHBTS); (2) partially accurate (in either the SS or LHBTS); (3) accurate with overflow (in both locations, but also elsewhere); (4) partially accurate with overflow (in either location, but also somewhere else); or (5) completely inaccurate (no latex in either location). All 12 ultrasound‐guided injections using the technique accurately placed latex into both LHBTS and SS (100% accuracy). Latex was also found in adjacent regions after two (17%) injections: one within the shoulder joint and one within the deltoid musculature. This newly described technique allows highly accurate access to the LHBTS and SS with single‐needle entry. This technique could become a favored alternative to subjecting patients to two needlesticks and preparing separate injections to address often concomitant pathologies.
T100: Long term Follow-up of a Phase I Study Combinations of Ipilimumab, Nivolumab and Brentuximab Vedotin in Patients with Relapsed/Refractory Hodgkin Lymphoma: A trial of the ECOG-ACRIN Research Group (E4412: Arms A-I)
Ambinder, Richard, Cohen, Jonathon B. , David, Kevin A. , Fenske, Timothy S. , Palmisiano, Neil , Svoboda, Jakub , Ansell, Stephen M. , Diefenbach, Catherine , Jegede, Opeyemi A. , Robertson, Michael J. , Advani, Ranjana H. , Barta, Stefan K , Morgan, David , Karmali, Reem , Kahl, Brad S.

HemaSphere | October 10, 2022 | Volume: 6 | Issue: No issue available | Pages: 46-47

10.1097/01.hs9.0000890968.53519.f4 Get It

The Elephant in the Waiting Room: An Urgent Call for Papers to Address the Public Health Crisis of Long COVID
Chakraborty, Rana , Lambert, Natalie , Pinto, Melissa D.

Clinical Nursing Research | October 6, 2022 | Volume: 31 | Issue: 8 | Pages: 1387-1389

10.1177/10547738221132603 | PMID 36200625 Get It

Renin: Measurements, Correlates, and Associations With Long-Term Adverse Kidney Outcomes
Blum, Matthew F. , Chen, Jingsha, Köttgen, Anna , Turner, Stephen T. , Surapaneni, Aditya , Ballantyne, Christie M. , Welling, Paul A. , Coresh, Josef , Crews, Deidra C. , Grams, Morgan Erika

American Journal of Hypertension | October 3, 2022 | Volume: 36 | Issue: 1 | Pages: 42-49

10.1093/ajh/hpac112 | PMID 36190914 Get It

Abstract Background The association of renin with adverse kidney outcomes is largely unknown, and renin measurement strategies vary. We aimed to measure the clinical correlates of different renin measurements and the association between renin and incident chronic kidney disease (CKD), end-stage kidney disease (ESKD), and mortality. Methods We performed a prospective cohort analysis of 9,420 participants in the Atherosclerosis Risk in Communities study followed from 1996 to 1998 through 2019. We estimated longitudinal associations of renin measured using SomaScan modified nucleotide aptamer assay with incident CKD, ESKD, and death using Cox proportional hazards models. Using samples from a subsequent study visit, we compared SomaScan renin with plasma renin activity (PRA) and renin level from Olink, and estimated associations with covariates using univariate and multivariable regression. Results Higher SomaScan renin levels were associated with a higher risk of incident CKD (hazard ratio per two-fold higher [HR], 1.14; 95% confidence interval [CI], 1.09 to 1.20), ESKD (HR, 1.20; 95% CI, 1.03 to 1.41), and mortality (HR, 1.08; 95% CI, 1.04 to 1.13) in analyses adjusted for demographic, clinical, and socioeconomic covariates. SomaScan renin was moderately correlated with PRA (r = 0.61) and highly correlated with Olink renin (r = 0.94). SomaScan renin and PRA had similar clinical correlates except for divergent associations with age and beta-blocker use, both of which correlated positively with SomaScan renin but negatively with PRA. Conclusions SomaScan aptamer-based renin level was associated with a higher risk of CKD, ESKD, and mortality. It was moderately correlated with PRA, sharing generally similar clinical covariate associations.
A Microfluidic Device for Long‐Term Maintenance of Organotypic Liver Cultures
Hoyos‐Vega, José M. de , Hong, Hye Jin , Revzin, Alexander , Vega, José M de Hoyos, Loutherback, Kevin , de Hoyos-Vega, Jose M , Stybayeva, Gulnaz

Advanced Materials Technologies | October 3, 2022 | Volume: 8 | Issue: 2 | Pages: No page available

10.1002/admt.202201121 | PMID 36818276 Get It

Abstract Liver cultures may be used for disease modeling, testing therapies, and predicting drug‐induced injury. The complexity of the liver cultures has evolved from hepatocyte monocultures to co‐cultures with non‐parenchymal cells and finally to precision‐cut liver slices. The latter culture format retains liver's native biomolecular and cellular complexity and therefore holds considerable promise for in vitro testing. However, liver slices remain functional for ≈72 h in vitro and display limited utility for some disease modeling and therapy testing applications that require longer culture times. This paper describes a microfluidic device for longer‐term maintenance of functional organotypic liver cultures. This microfluidic culture system is designed to enable direct injection of liver tissue into a culture chamber through a valve‐enabled side port. Liver tissue is embedded in collagen and remained functional for up to 31 days, highlighted by continued production of albumin and urea. These organotypic cultures also express several enzymes involved in xenobiotic metabolism. Conversely, matched liver tissue embedded in collagen in a 96‐well plate loses its phenotype and function within 3–5 days. The microfluidic organotypic liver cultures described here represent a significant advance in liver cultivation and may be used for future modeling of liver diseases or for individualized liver‐directed therapies.
Treatment of giant intracranial aneurysms using the Pipeline flow-diverting stent: Long-term results from the International Retrospective Study of the Pipeline Embolization Device (IntrePED) study
Grandhi, Ramesh , Ravindra, Vijay M. , Kallmes, David F. , Hanel, Ricardó A. , Lylyk, Pedro , Hanel, Ricardo A , Grandhi, Ramesh , Lopes, Demetrius K.

Interventional Neuroradiology | September 28, 2022 | Volume: 30 | Issue: 2 | Pages: 218-226

10.1177/15910199221123282 | PMID 36168255 Get It

Background Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms. Methods This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013. Efficacy outcomes were stratified by using the Raymond-Roy Occlusion Classification. Predefined safety outcomes included spontaneous rupture of the target aneurysm; ipsilateral intracranial hemorrhage; ischemic stroke; parent artery stenosis; and sustained cranial neuropathy. Results Sixty-six embolizations were performed to treat 63 giant intracranial aneurysms (including 2 ruptured): 49 (77.8%) in the anterior and 14 (22.2%) in the posterior circulation. The median follow-up was 22.4 (0.1–60.5) months. Class I angiographic occlusion was achieved in 72.0% (36/50). The neurological morbidity/mortality rate was 23.8% (15/63), with higher rates in the posterior circulation than in the anterior circulation (22.4% vs. 28.6%). Among seven deaths, five had neurological causes. The procedure-related neurological morbidity and mortality rates were 22.7% (15/66) and 7.6% (5/66), respectively. The spontaneous rupture rate was 4.5% (3/66). Two spontaneous ruptures (1 death), 4/4 postprocedural intracranial hemorrhages, and 6/9 ischemic events occurred within 30 days. In-stent stenosis and new-onset cranial neuropathy were not observed during the angiographic follow-up period. Conclusions Although procedure-related neurological morbidity/mortality rates were not insignificant, this study confirms the feasibility and long-term efficacy of the Pipeline Embolization Device to treat giant intracranial aneurysms.