Back to Authors

Hoyos‐Vega, José M. de

https://orcid.org/0000-0001-7537-1090

Mayo Clinic

Mayo Clinic

Citations 11

Electrochemical immunosensor-enabled liquid biopsy of extracellular vesicles for diagnosis of metabolic dysfunction-associated steatohepatitis
Nguyen, Thi Thanh Qui, Lee, Seonhwa , Mauer, Amy S. , Giron, Anthony, Cedillo‐Alcantar, Diana F. , Graham, Rondell, Allen, Alina, Revzin, Alexander, Choi, Daheui , Hoyos‐Vega, José M. de , Daniel, P. Vineeth , Eller, Michael J. , Stybayeva, Gulnaz , Lazaridis, Konstantinos , Malhi, Harmeet , Revzin, Alexander

No container title available | September 8, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.09.02.26362088 Get It

Abstract Accurate, noninvasive biomarkers for diagnosis and longitudinal monitoring of metabolic dysfunction–associated steatohepatitis (MASH) remain an urgent unmet clinical need. Here, we describe an electrochemical immunoassay that involves capturing hepatic extracellular vesicles (EVs) on antibody-modified electrodes followed by detecting EV-borne biomarkers using redox active gold nanoparticles (AuNPs). The intensity of electrochemical redox signal represents a quantitative measure of biomarker abundance. Three MASH-associated biomarkers—S100A11, TNF-α, and TGF-β1—were analyzed on hepatic EVs to assess steatotic, inflammatory, and fibrotic states of the diseased liver. The electrochemical signals for individual biomarkers were added into a composite EV MASH score. Plasma samples from 28 patients with MASH, 22 healthy controls, and 27 patients with non-MASH liver disease were scored in this manner, revealing 100% accuracy in the training cohort and >90% accuracy in an independent validation cohort. Our electrochemical immunosensor represents a minimally invasive liquid liver biopsy, offering a promising alternative to solid liver biopsies for screening and monitoring of MASH. One Sentence Summary Circulating hepatic extracellular vesicles carry biomarkers of liver injury enabling accurate, minimally invasive MASH diagnosis in blood.
A Practical Guide to Developing and Troubleshooting Patient-Derived “Mini-Gut” Colorectal Organoids for Clinical Research
Balaya, Rex Devasahayam Arokia , Heydari, Zahra , Sarkar, Gobinda , Garcia, Edwin , Hoyos‐Vega, José M. de , Krueger, Eugene W. , Helgeson, Lauren, Revzin, Alexander , Ros, Alexandra , Pandey, Akhilesh , Boardman, Lisa, Devasahayam Arokia Balaya, Rex , Cruz Garcia, Estela Mariel , de Hoyos-Vega, Jose M , Krueger, Eugene W , Pandey, Akhilesh , Boardman, Lisa

Methods and Protocols | October 13, 2025 | Volume: 8 | Issue: 5 | Pages: 121

10.3390/mps8050121 Get It

Patient-derived organoids (PDOs) have emerged as powerful tools in personalized medicine applicable to both non-malignant conditions and to cancer, where they are increasingly used for personalized drug screening and precision treatment strategies in part due to their ability to replicate tumor heterogeneity. They also serve as study model systems to understand disease mechanisms, pathways, and the impact of ex vivo exposures. We present a detailed step-by-step protocol for generating organoids from normal crypts, polyps, and tumors, including methods for tissue processing, crypt isolation, culture establishment, and the transition from basolateral to apical-out polarity for co-culture and exposure-based studies. The protocol also includes immunofluorescence staining procedures for cellular characterization and quality control measures. Our standardized approach successfully generates organoids from diverse colorectal tissues with high efficiency and reproducibility. This comprehensive guide addresses common technical challenges and provides troubleshooting strategies to improve success rates across different sample types. We believe that this resource will enhance reproducibility in organoid research and expand their utility in translational applications, particularly for personalized medicine approaches in colorectal cancer.
An Ultrathin Coating of Microcapsules Enhances the Function of Encapsulated Hepatocyte Spheroids
Lee, Seonhwa , Nguyen, Kianna M. , Gonzalez‐Suarez, Alan M. , Revzin, Alexander , Choi, Daheui , Revzin, Alexander , Gonzalez-Suarez, Alan M , Nguyen, Kianna M , Gwon, Kihak , Hoyos‐Vega, José M. de , Stybayeva, Gulnaz

ACS Applied Materials & Interfaces | September 13, 2024 | Volume: 16 | Issue: 38 | Pages: 51411-51420

10.1021/acsami.4c08329 Get It

Using Microfluidic Hepatic Spheroid Cultures to Assess Liver Toxicity of T-2 Mycotoxin
Taroncher, Mercedes , Gonzalez‐Suarez, Alan M. , Romero, Samuel, Reyes-Figueroa, A. D. , Rodríguez-Carrasco, Yelko , Ruiz, María-José , Stybayeva, Gulnaz , Revzin, Alexander , Hoyos‐Vega, José M. de , Reyes-Figueroa, Angel D , Rodríguez-Carrasco, Yelko , Ruiz, María-José , Stybayeya, Gulnaz , de Hoyos-Vega, Jose M , Gonzalez-Suarez, Alan M , Gwon, Kihak , Romero, Samuel

Cells | May 24, 2024 | Volume: 13 | Issue: 11 | Pages: 900

10.3390/cells13110900 Get It

The Fusarium fungi is found in cereals and feedstuffs and may produce mycotoxins, which are secondary metabolites, such as the T-2 toxin (T-2). In this work, we explored the hepatotoxicity of T-2 using microfluidic 3D hepatic cultures. The objectives were: (i) exploring the benefits of microfluidic 3D cultures compared to conventional 3D cultures available commercially (Aggrewell plates), (ii) establishing 3D co-cultures of hepatic cells (HepG2) and stellate cells (LX2) and assessing T-2 exposure in this model, (iii) characterizing the induction of metabolizing enzymes, and (iv) evaluating inflammatory markers upon T-2 exposure in microfluidic hepatic cultures. Our results demonstrated that, in comparison to commercial (large-volume) 3D cultures, spheroids formed faster and were more functional in microfluidic devices. The viability and hepatic function decreased with increasing T-2 concentrations in both monoculture and co-cultures. The RT-PCR analysis revealed that exposure to T-2 upregulates the expression of multiple Phase I and Phase II hepatic enzymes. In addition, several pro- and anti-inflammatory proteins were increased in co-cultures after exposure to T-2.
Microfluidic Organoid Cultures Derived from Pancreatic Cancer Biopsies for Personalized Testing of Chemotherapy and Immunotherapy
Choi, Daheui , Gonzalez‐Suarez, Alan M. , Dumbravă, Mihai , Medlyn, Michael, Cichocki, Frank, Zhu, Mojun , Gaspar‐Maia, Alexandre , Billadeau, Daniel D. , Revzin, Alexander , Dumbrava, Mihai G, Revzin, Alexander , Dumbrava, Mihai , Gaspar-Maia, Alexandre , Gonzalez-Suarez, Alan M , Medlyn, Michael J. , Hoyos‐Vega, José M. de , Cichocki, Frank , Miller, Jeffrey S. , Li, Ding , Stybayeva, Gulnaz , Wee, Wen

Advanced Science | November 29, 2023 | Volume: 11 | Issue: 5 | Pages: No page available

10.1002/advs.202303088 Get It

AbstractPatient‐derived cancer organoids (PDOs) hold considerable promise for personalizing therapy selection and improving patient outcomes. However, it is challenging to generate PDOs in sufficient numbers to test therapies in standard culture platforms. This challenge is particularly acute for pancreatic ductal adenocarcinoma (PDAC) where most patients are diagnosed at an advanced stage with non‐resectable tumors and where patient tissue is in the form of needle biopsies. Here the development and characterization of microfluidic devices for testing therapies using a limited amount of tissue or PDOs available from PDAC biopsies is described. It is demonstrated that microfluidic PDOs are phenotypically and genotypically similar to the gold‐standard Matrigel organoids with the advantages of 1) spheroid uniformity, 2) minimal cell number requirement, and 3) not relying on Matrigel. The utility of microfluidic PDOs is proven by testing PDO responses to several chemotherapies, including an inhibitor of glycogen synthase kinase (GSKI). In addition, microfluidic organoid cultures are used to test effectiveness of immunotherapy comprised of NK cells in combination with a novel biologic. In summary, our microfluidic device offers considerable benefits for personalizing oncology based on cancer biopsies and may, in the future, be developed into a companion diagnostic for chemotherapy or immunotherapy treatments.
Modeling Gut Neuro-Epithelial Connections in a Novel Microfluidic Device
Hoyos‐Vega, José M. de , Yu, Xi , Gonzalez‐Suarez, Alan M. , Mercado‐Perez, Arnaldo , Krueger, Eugene W. , Hernandez, Jeric, Druliner, Brooke R., Chen, Sisi , Fedyshyn, Yaroslav , Revzin, Alexander , de Hoyos-Vega, Jose M , Gonzalez-Suarez, Alan, Krueger, Eugene, Druliner, Brooke , Gonzalez-Suarez, Alan M , Druliner, Brooke R. , Linden, David R. , Beyder, Arthur

No container title available | September 7, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-2972828/v1 Get It

Abstract Organs that face external environments, such as skin and gut, are lined by epithelia, which have two functions – to provide a semi-permeable barrier and to sense stimuli. The intestinal lumen is filled with diverse chemical and physical stimuli. Intestinal epithelial cells sense these stimuli and signal to enteric neurons which coordinate a range of physiologic processes required for normal digestive tract function. Yet, the neuro-epithelial connections between intestinal epithelial cells and enteric neurons remain poorly resolved, which leaves us with limited mechanistic understanding of their function. We describe the development of a two-compartment microfluidic device for modeling neuro-epithelial interactions, and apply it to form the gut’s neuro-epithelial connections. The device contains epithelial and neuronal compartments connected by microgrooves. The epithelial compartment was designed for cell seeding via injection and confinement of intestinal epithelial cells derived from human intestinal organoids. We demonstrated that organoids planarized effectively and retained epithelial phenotype for over a week. In the second chamber we dissociated and cultured intestinal myenteric neurons including intrinsic primary afferent neurons (IPANs) from transgenic mice that expressed the fluorescent protein tdTomato. IPANs extended projections into microgrooves, surrounded and frequently made contacts with epithelial cells. The density and directionality of neuronal projections were enhanced by the presence of epithelial cells in the adjacent compartment. Our microfluidic device represents a platform for dissecting structure and function of neuro-epithelial connections in the gut and other organs (skin, lung, bladder, and others) in health and disease.
Guiding Hepatic Differentiation of Pluripotent Stem Cells Using 3D Microfluidic Co-Cultures with Human Hepatocytes
Fattahi, Pouria , Hoyos‐Vega, José M. de , Duffy, Caden D., Gonzalez‐Suarez, Alan M. , Ishida, Yuji , Nguyen, Kianna M. , Gwon, Kihak , Peterson, Quinn P. , Saito, Takeshi , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Choi, Jong Hoon , Gonzalez-Suarez, Alan M , Nguyen, Kianna M , Saito, Takeshi , Stybayeya, Gulnaz , Gwon, Kihak , Peterson, Quinn , Choi, Jong Hoon

Cells | August 1, 2023 | Volume: 12 | Issue: 15 | Pages: 1982

10.3390/cells12151982 Get It

Human pluripotent stem cells (hPSCs) are capable of unlimited proliferation and can undergo differentiation to give rise to cells and tissues of the three primary germ layers. While directing lineage selection of hPSCs has been an active area of research, improving the efficiency of differentiation remains an important objective. In this study, we describe a two-compartment microfluidic device for co-cultivation of adult human hepatocytes and stem cells. Both cell types were cultured in a 3D or spheroid format. Adult hepatocytes remained highly functional in the microfluidic device over the course of 4 weeks and served as a source of instructive paracrine cues to drive hepatic differentiation of stem cells cultured in the neighboring compartment. The differentiation of stem cells was more pronounced in microfluidic co-cultures compared to a standard hepatic differentiation protocol. In addition to improving stem cell differentiation outcomes, the microfluidic co-culture system described here may be used for parsing signals and mechanisms controlling hepatic cell fate.
A Microfluidic Device for Long‐Term Maintenance of Organotypic Liver Cultures
Hoyos‐Vega, José M. de , Hong, Hye Jin , Revzin, Alexander , Vega, José M de Hoyos, Loutherback, Kevin , de Hoyos-Vega, Jose M , Stybayeva, Gulnaz

Advanced Materials Technologies | October 3, 2022 | Volume: 8 | Issue: 2 | Pages: No page available

10.1002/admt.202201121 Get It

Abstract Liver cultures may be used for disease modeling, testing therapies, and predicting drug‐induced injury. The complexity of the liver cultures has evolved from hepatocyte monocultures to co‐cultures with non‐parenchymal cells and finally to precision‐cut liver slices. The latter culture format retains liver's native biomolecular and cellular complexity and therefore holds considerable promise for in vitro testing. However, liver slices remain functional for ≈72 h in vitro and display limited utility for some disease modeling and therapy testing applications that require longer culture times. This paper describes a microfluidic device for longer‐term maintenance of functional organotypic liver cultures. This microfluidic culture system is designed to enable direct injection of liver tissue into a culture chamber through a valve‐enabled side port. Liver tissue is embedded in collagen and remained functional for up to 31 days, highlighted by continued production of albumin and urea. These organotypic cultures also express several enzymes involved in xenobiotic metabolism. Conversely, matched liver tissue embedded in collagen in a 96‐well plate loses its phenotype and function within 3–5 days. The microfluidic organotypic liver cultures described here represent a significant advance in liver cultivation and may be used for future modeling of liver diseases or for individualized liver‐directed therapies.
Coating Bioactive Microcapsules with Tannic Acid Enhances the Phenotype of the Encapsulated Pluripotent Stem Cells
Gwon, Kihak , Hong, Hye Jin , Baskaran, Harihara , Calvo-Lozano, Olalla , Gonzalez‐Suarez, Alan M. , Park, Kyungtae , Lechuga, Laura M. , Hong, Jinkee , Revzin, Alexander , Choi, Daheui , Calvo-Lozano, Olalla , Gonzalez-Suarez, Alan M, Lechuga, Laura M , Hong, Jinkee , Revzin, Alexander , Gwon, Kihak , Gonzalez-Suarez, Alan M , Hoyos‐Vega, José M. de , Stybayeva, Gulnaz

ACS Applied Materials & Interfaces | June 4, 2022 | Volume: 14 | Issue: 23 | Pages: 27274-27286

10.1021/acsami.2c06783 Get It

Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors
Hoyos‐Vega, José M. de , Hong, Hye Jin , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Stybayeya, Gulnaz

APL Bioengineering | October 14, 2021 | Volume: 5 | Issue: 4 | Pages: No page available

10.1063/5.0058798 Get It

Hepatocytes are parenchymal cells of the liver responsible for drug detoxification, urea and bile production, serum protein synthesis, and glucose homeostasis. Hepatocytes are widely used for drug toxicity studies in bioartificial liver devices and for cell-based liver therapies. Because hepatocytes are highly differentiated cells residing in a complex microenvironment in vivo, they tend to lose hepatic phenotype and function in vitro. This paper first reviews traditional culture approaches used to rescue hepatic function in vitro and then discusses the benefits of emerging microfluidic-based culture approaches. We conclude by reviewing integration of hepatocyte cultures with bioanalytical or sensing approaches.