Back to Authors

Hanel, Ricardo A

0000-0001-7195-5806

Mayo Clinic

Lyerly Neurosurgery, Baptist Medical Center Downtown, Jacksonville, Florida, USA Ricardo.Hanel@bmcjax.com.

Citations 8

Delayed aneurysm rupture after flow-diverter deployment in unruptured aneurysms: a systematic review and meta-analysis
Rodriguez‐Erazú, Fernanda , Ghozy, Sherief , Gutierrez‐Aguirre, Salvador F. , Lara-Velazquez, Montserrat , Cortese, Jonathan , Douri, Dani, Toledo, Otavio F. De , Patel, Milin , Sriraman, Sheetal , Sauvageau, Eric , Kallmes, David F, Ghozy, Sherief , Gutierrez-Aguirre, Salvador F , Lara-Velazquez, Montserrat , Cortese, Jonathan , De Toledo, Otavio Frederico , Aghaebrahim, Amin , Sauvageau, Eric , Hanel, Ricardo A , Hamouda, Abdelrahman M. , Sriraman, Sri, Kallmes, David F. , Hanel, Ricardó A.

Journal of NeuroInterventional Surgery | December 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: jnis-2025-024135

10.1136/jnis-2025-024135 Get It

Background Delayed aneurysm rupture (DAR) is a potentially devastating complication after flow-diverters (FD) deployment and their exact mechanisms are still unclear. The purpose of this meta-analysis is to synthesize the latest evidence on DAR after FD treatment and identify predictive factors. Methods A systematic review and meta-analysis were conducted according to established protocols. Searches were conducted in PubMed, Scopus, Web of Science, and Embase databases up to June 2024 using variations of “aneurysm “and “delayed aneurysm rupture” terms. Original studies reporting DAR and including more than five patients were included. All analyses were conducted in R software (version 4.4.2), employing the “meta” and “tableone” packages. Results 64 studies with 9820 patients were included, large aneurysm size (OR=1.08, 95% CI (1.02, 1.14), P value=0.008), intra-aneurysmal thrombus (OR=1.05, 95% CI (1.01, 1.09), P value=0.010) and posterior circulation location (OR=1.02, 95% CI (1.00, 1.04), P value=0.014) were significant risk factors for DAR. The pooled prevalence of DAR was 1.40%, with a rate of 1.18% after removing outliers. DAR occurred within 30 days in 66.7% of cases, with a mortality rate of 73.3% at discharge. Conclusion DAR following flow diversion treatment is an uncommon but devastating complication and remains a limitation of the technique. It is influenced by factors such as large aneurysm size, intra-aneurysmal thrombosis, and posterior circulation involvement. The first 30 days post-procedure represent a particularly high-risk period. Despite advancements in FD technology, significant gaps remain, highlighting the need for further research to improve risk assessment and treatment strategies.
EXCELLENT Registry: A Prospective, Multicenter, Global Registry of Endovascular Stroke Treatment With the EMBOTRAP Device
Nogueira, Raul G. , Andersson, Tommy , Haussen, Diogo C , Yoo, Albert J. , Hanel, Ricardó A. , Zaidat, Osama O. , Hacke, Werner , Fiehler, Jens , Brinjikji, Waleed , Doyle, Karen , Kallmes, David F. , Liebeskind, David S. , Kokoszka, Malgosia A., Inoa, Violiza , Humphries, William, Woodward, Keith, Bozorgchami, Hormozd, Boor, Stephan , Cohen, José E. , Taqi, Muhammad , Budzik, Ronald F. , Hussain, M. Shazam , Estrade, Laurent , Puri, Ajit S., Brekenfeld, Caspar , Siddiqui, Adnan H. , Jovin, Tudor G , Fiehler, Jens , De Meyer, Simon F , Brinjikji, Waleed , Doyle, Karen M , Liebeskind, David S. , Virmani, Renu , Inoa, Violiza , Jabbour, Pascal , Levy, Elad I , Boor, Stephan , Cohen, Jose E , Dashti, Shervin R , Schirmer, Clemens M , Estrade, Laurent , De Leacy, Reade , Chitale, Rohan V , Brekenfeld, Caspar , Siddiqui, Adnan H , Andersson, Tommy , Hanel, Ricardo A , Nogueira, Raul G , Yoo, Albert J , Jovin, Tudor G. , Virmani, Renu , Jabbour, Pascal , François, Olivier , Levy, Elad I. , Schirmer, Clemens M. , Leacy, Reade De , Puri, Ajit S

Stroke | November 19, 2024 | Volume: 55 | Issue: 12 | Pages: 2804-2814

10.1161/strokeaha.124.047324 Get It

BACKGROUND: The EXCELLENT registry aimed to evaluate the effectiveness of the EMBOTRAP Revascularization Device in an all-comer population in a real-world setting, with a focus on the composition of retrieved clots. METHODS: EXCELLENT is a prospective, global registry of patients with acute ischemic stroke treated with EMBOTRAP as the first-line mechanical thrombectomy device conducted at 34 sites (25 sites contributing clot) from September 2018 to March 2021, utilizing core imaging and central histology laboratories blinded to clinical data, independent 90-day modified Rankin Scale assessment and Clinical Events Committee. RESULTS: After screening 3799 patients, a total of 997 subjects (mean age, 70.0±14.2 years; 51.8% women; 19.7% non-White) were included. The first-pass modified Treatment in Cerebral Infarction (mTICI) ≥2b rate was 64.5% (623/966), first-pass mTICI ≥2c was 39.1% (378/966), and final mTICI ≥2b was 94.5% (931/985). A total of 427/912 (46.8%) patients achieved a 90-day modified Rankin Scale of 0 to 2 or ≤baseline. Embolization to a new territory occurred in 0.2% (2/984), and symptomatic intracranial hemorrhage at 24 hours in 1.6% (16/997). The 90-day mortality was 19.1% (175/918). Device- and/or procedure-related serious adverse events occurred in 5.9% (54/912) through 90 days. The mean RBC percentage of retrieved clots was 45.62±21.372. Among patients who achieved mTICI ≥2b with the first pass, 15.7% (52/331) and 9.7% (32/331), respectively, had RBC-poor (<25%) and RBC-rich (>75%) clots. Patients with no clot retrieved in any procedural pass had a lower percentage of hyperdense or susceptibility vessel sign on baseline imaging (58.9% versus 74.7%; P <0.001), pointing to a potential preprocedure indicator of challenging clot. CONCLUSIONS: The EXCELLENT registry informs real-world practices in mechanical thrombectomy and sheds light on the range of clots effectively retrieved by current technology. This is the first report of detailed patient characteristics where mechanical thrombectomy maneuvers failed to remove any clot material. Although the composition of nonretrievable clots cannot be assessed histologically, the results support the notion that no retrieval may be correlated with imaging findings suggesting clots lower in RBC. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03685578.
Braids and beyond: a comprehensive study on pipeline device braid stability from PREMIER data
Rodriguez‐Erazú, Fernanda , Cortez, Gustavo M , Gutierrez‐Aguirre, Salvador F. , Toledo, Otavio F. De , Aghaebrahim, Amin, Sauvageau, Eric , Kallmes, David F. , Fiehler, Jens , Hanel, Ricardó A. , Gutierrez-Aguirre, Salvador F , De Toledo, Otavio Frederico , Aghaebrahim, Amin , Sauvageau, Eric , Fiehler, Jens , Hanel, Ricardo A , Lopes, Demetrius K.

Journal of NeuroInterventional Surgery | October 2, 2024 | Volume: 17 | Issue: 12 | Pages: 1362-1367

10.1136/jnis-2024-022350 Get It

Background The pipeline embolization device (PED) has been increasingly used to treat brain aneurysms; however, concerns have been raised about braid stability with newer drawn filled tubing technology devices. Objective To evaluate braid stability of PED early generations using data from the PREMIER trial. Methods All consecutive intracranial aneurysms treated with PED (Classic and Flex) within the PREMIER trial were reviewed for braid stability (fish mouthing, foreshortening, braid bump, braid collapsing). Immediate postprocedure cone-beam CT and angiography were compared with 1- and 2- years' follow-up. Analyses included safety, measured with the modified Rankin Scale (mRS) score, including +1 mRS point and a good clinical outcome (mRS score 0–2), vessel stenosis ≥50%, effectiveness measured with Raymond-Roy Scale, and re-treatment rates. Results 133/141 aneurysms had a complete dataset. 8/133 (6%) aneurysms showed braid deformations. Inter-reader agreement was excellent (κ=0.83). Braid deformations were statistically significantly associated with in-stent vessel stenosis >50% (P=0.029), without impact on effectiveness or safety. Fish mouthing was found in 1/133 (0.75%) at 1 year, causing >50% vessel stenosis. Foreshortening occurred in 6/133 (4.5%), and braid bump in 1/133 (0.75%) associated with severe in-stent stenosis. Four other cases (3.0%) of asymptomatic in-stent stenosis due to neointimal hyperplasia were seen without braid changes. No new braid stability deformations were found at the 2-year follow-up. Conclusion Our study demonstrates excellent braid stability among patients treated with the PED Classic and Flex in the PREMIER trial. Within the uncommon braid changes observed, none affected the PED safety or efficacy. Trial registration number NCT02186561 .
Impact of duration of dual anti-platelet therapy on risk of complications after stent-assisted coiling of unruptured aneurysms
Ringer, Andrew J. , Hanel, Ricardó A. , Baig, Ammad A. , Siddiqui, Adnan H. , Lopes, Demetrius K. , Barros, Guilherme , Bass, David I. , Levitt, Michael R. , Young, Christopher C. , Naylor, Ryan M. , Crowley, R. Webster , Serrone, Joseph C. , Kan, Peter , Binning, Mandy J., Veznedaroglu, Erol, Boulos, Alan S. , Lopes, Demetrius Klee , Kan, Peter , Tawk, Rabih G , Levitt, Michael R , Siddiqui, Adnan H , Hanel, Ricardo A , Lanzino, Giuseppe , Tawk, Rabih G.

Journal of NeuroInterventional Surgery | August 13, 2024 | Volume: 17 | Issue: 9 | Pages: 956-960

10.1136/jnis-2024-021977 Get It

Background The optimal duration for dual antiplatelet therapy (DAPT) after stent-assisted coiling (SAC) of intracranial aneurysms is unclear. Longer-term therapy may reduce thrombotic complications but increase the risk of bleeding complications. Methods A retrospective review of prospectively maintained data at 12 institutions was conducted on patients with unruptured intracranial aneurysms who underwent SAC between January 1, 2016 and December 31, 2020, and were followed ≥6 months postprocedure. The type and duration of DAPT, stent(s) used, outcome, length of follow-up, complication rates, and incidence of significant in-stent stenosis (ISS) were collected. Results Of 556 patients reviewed, 450 met all inclusion criteria. Nine patients treated with DAPT <29 days after SAC and 11 treated for 43–89 days were excluded from the final analysis as none completed their prescribed duration of treatment. Eighty patients received short-term DAPT. There were no significant differences in the rate of thrombotic complications during predefined periods of risk in the short, medium, or long-term treatment groups (1/80, 1.3%; 2/188, 1.1%; and 0/162, 0%, respectively). Similarly, no differences were found in the rate of hemorrhagic complications during period of risk in any group (0/80, 0%; 3/188, 1.6%; and 1/162, 0.6%, respectively). Longer duration DAPT did not reduce ISS risk in any group. Conclusions Continuing DAPT >42 days after SAC did not reduce the risk of thrombotic complications or in-stent stenosis, although the risk of additional hemorrhagic complications remained low. It may be reasonable to discontinue DAPT after 42 days following non-flow diverting SAC of unruptured intracranial aneurysms.
Factors Affecting Selection of TraineE for Neurointervention (FASTEN)
Elfil, Mohamed , Ghozy, Sherief , Elmashad, Ahmed , Al‐Bayati, Alhamza R , Alaraj, Ali , Brook, Allan , Kam, Anthony W. , Waldau, Ben , Altschul, David , Parrella, David Turkel, Tóth, Gábor , Jindal, Gaurav , Shaikh, Hamza , Dolia, Jaydevsinh , Thomas, Justin, Kim, Louis J. , Harrigan, Mark R. , Kole, Max , Mokin, Max, Janjua, Nazli , Zaidat, Osama O. , Youssef, Patrick , Khandelwal, Priyank , Wang, Qingliang Tony, Szeder, Viktor , Tanweer, Omar , Jankowitz, Brian T. , Heit, Jeremy J. , Williamson, Richard , Kass‐Hout, Tareq , Crowley, R. Webster , El‐Ghanem, Mohammad , Kam, Anthony , Ghozy, Sherief , Siddiqui, Adnan H , Al-Bayati, Alhamza , Alaraj, Ali , Kam, Anthony W , Matouk, Charles , Schirmer, Clemens M , Altschul, David J , Shaikh, Hamza A , Amuluru, Krishna , Grandhi, Ramesh , Hanel, Ricardo A , Ortega-Gutierrez, Santiago , Nguyen, Thanh N , Szeder, Viktor , Heit, Jeremy J , Al-Mufti, Fawaz , Elfil, Mohamed , Dolia, Jaidevsinh , Morsi, Rami Z. , Siddiqui, Adnan H. , Chatterjee, Arindam R , Patsalides, Athos T , Prestigiacomo, Charles Joseph , Matouk, Charles , Schirmer, Clemens M. , Fifi, Johanna T , Fraser, Justin F , Kim, Louis J. , Amans, Matthew R. , Abraham, Michael G. , Jumaa, Mouhammad , Grandhi, Ramesh , Hanel, Ricardó A. , Kellogg, Ryan Thomson , Sheth, Sunil A , Nguyen, Thanh N. , Hu, Yin , Yoo, Albert J. , Al‐Mufti, Fawaz

Interventional Neuroradiology | February 23, 2024 | Volume: 32 | Issue: 4 | Pages: 1253-1260

10.1177/15910199241232726 Get It

Background and importance Neurointervention is a very competitive specialty in the United States due to the limited number of training spots and the larger pool of applicants. The training standards are continuously updated to ensure solid training experiences. Factors affecting candidate(s) selection have not been fully established yet. Our study aims to investigate the factors influencing the selection process. Methods A 52-question survey was distributed to 93 program directors (PDs). The survey consisted of six categories: (a) Program characteristics, (b) Candidate demographics, (c) Educational credentials, (d) Personal traits, (e) Research and extracurricular activities, and (f) Overall final set of characteristics. The response rate was 59.1%. As per the programs’ characteristics, neurosurgery was the most involved specialty in running the training programs (69%). Regarding demographics, the need for visa sponsorship held the greatest prominence with a mean score of 5.9 [standard deviation (SD) 2.9]. For the educational credentials, being a graduate from a neurosurgical residency and the institution where the candidate's residency training is/was scored the highest [5.4 (SD = 2.9), 5.4 (SD = 2.5), respectively]. Regarding the personal traits, assessment by faculty members achieved the highest score [8.9 (SD = 1)]. In terms of research/extracurricular activities, fluency in English had the highest score [7.2 (SD = 1.9)] followed by peer-reviewed/PubMed-indexed publications [6.4 (SD = 2.2)]. Conclusion Our survey investigated the factors influencing the final decision when choosing the future neurointerventional trainee, including demographic, educational, research, and extracurricular activities, which might serve as valuable guidance for both applicants and programs to refine the selection process.
Safety and Efficacy of Flow Diverters for Treatment of Unruptured Anterior Communicating Artery Aneurysms: Retrospective Multicenter Study
Benalia, Victor H. C. , Saatçi, Işıl , Cekirge, H Saruhan , Dabus, Guilherme , Brinjikji, Waleed , Nishi, Hidehisa , Siddiqui, Adnan H. , Aghaebrahim, Amin, Sauvageau, Eric , Saatci, Isil , Çekirge, Saruhan , Dabus, Guilherme C. , Nishi, Hidehisa , Monteiro, Andre , Aghaebrahim, Amin , Hanel, Ricardo A , Siddiqui, Adnan H , Cortez, Gustavo M , Mounayer, Charbel , Koçer, Naci , Işlak, Civan , Baltacıoğlu, Feyyaz , Mendes Pereira, Vitor , Lopes, Demetrius K. , Hanel, Ricardó A.

Journal of NeuroInterventional Surgery | October 16, 2023 | Volume: 15 | Issue: 12 | Pages: 1181-1186

10.1136/jnis-2023-020673 Get It

Background The anterior communicating artery (AComm) region is the most common site of intracranial aneurysms, with increased rupture risk compared with other locations. Overall, flow diverters present as a safe and efficacious treatment for intracranial aneurysms, but there is paucity of data for their use in the treatment of unruptured AComm aneurysms. We present the largest multicentric analysis evaluating the outcomes of flow diverters in AComm aneurysm treatment. Methods Databases from 10 centers were retrospectively reviewed for unruptured AComm aneurysms treated with flow diverters. Demographics, clinical presentation, radiographic characteristics, procedural complications, and outcomes were assessed. Results A total of 144 patients harboring 147 AComm aneurysms were treated between January 2012 and December 2021. Seventy-four were women (51.4%) and median age was 60 (IQR 50–67) years. All were unruptured AComm aneurysms. Half of the cohort had similar anterior cerebral artery sizes (51.4%). The most common morphology was saccular (94.6%), with a branch involvement in 32.7% of cases. Median vessel diameter was 2.4 mm, and the Pipeline Flex was the most prevalent device (32.7%). Median follow-up time was 17 months, with complete occlusion in 86.4% at the last follow-up. Functional independence (modified Rankin Scale score 0–2) was reported in 95.1%. Intraprocedural complications occurred in 5.6%, and postoperative complications were noted in 9.7% of cases. Combined major complication and mortality rate was 2.1%. Conclusions Our study suggests that flow diverters are a useful treatment for AComm aneurysms. Mid-term results indicated favorable aneurysm occlusion with a good safety profile. Additional prospective studies with longer follow-up periods and independent adjudication are warranted to better assess these results.
Treatment of giant intracranial aneurysms using the Pipeline flow-diverting stent: Long-term results from the International Retrospective Study of the Pipeline Embolization Device (IntrePED) study
Grandhi, Ramesh , Ravindra, Vijay M. , Kallmes, David F. , Hanel, Ricardó A. , Lylyk, Pedro , Hanel, Ricardo A , Grandhi, Ramesh , Lopes, Demetrius K.

Interventional Neuroradiology | September 28, 2022 | Volume: 30 | Issue: 2 | Pages: 218-226

10.1177/15910199221123282 Get It

Background Traditional endovascular treatments of giant intracranial aneurysms are associated with high rates of complications and retreatment. Our objective was to examine the safety and long-term efficacy of the Pipeline Embolization Device for treatment of these aneurysms. Methods This retrospective study using the IntrePED database included all patients with giant intracranial aneurysms treated with the Pipeline device between July 2008 and February 2013. Efficacy outcomes were stratified by using the Raymond-Roy Occlusion Classification. Predefined safety outcomes included spontaneous rupture of the target aneurysm; ipsilateral intracranial hemorrhage; ischemic stroke; parent artery stenosis; and sustained cranial neuropathy. Results Sixty-six embolizations were performed to treat 63 giant intracranial aneurysms (including 2 ruptured): 49 (77.8%) in the anterior and 14 (22.2%) in the posterior circulation. The median follow-up was 22.4 (0.1–60.5) months. Class I angiographic occlusion was achieved in 72.0% (36/50). The neurological morbidity/mortality rate was 23.8% (15/63), with higher rates in the posterior circulation than in the anterior circulation (22.4% vs. 28.6%). Among seven deaths, five had neurological causes. The procedure-related neurological morbidity and mortality rates were 22.7% (15/66) and 7.6% (5/66), respectively. The spontaneous rupture rate was 4.5% (3/66). Two spontaneous ruptures (1 death), 4/4 postprocedural intracranial hemorrhages, and 6/9 ischemic events occurred within 30 days. In-stent stenosis and new-onset cranial neuropathy were not observed during the angiographic follow-up period. Conclusions Although procedure-related neurological morbidity/mortality rates were not insignificant, this study confirms the feasibility and long-term efficacy of the Pipeline Embolization Device to treat giant intracranial aneurysms.
Embotrap Extraction & Clot Evaluation & Lesion Evaluation for NeuroThrombectomy (EXCELLENT) Registry design and methods
Siddiqui, Adnan H. , Waqas, Muhammad , Brinjikji, Waleed , Doyle, Karen , Fiehler, Jens , Hacke, Werner , Hanel, Ricardó A. , Liebeskind, David S. , Zaidat, Osama O. , Doyle, Karen M , Fiehler, Jens , Hanel, Ricardo A , Zaidat, Osama O , Liebeskind, David S. , Waqas, Muhammad , Siddiqui, Adnan H , De Meyer, Simon F , Jovin, Tudor G. , Yoo, Albert J. , Andersson, Tommy , Nogueira, Raul G.

Journal of NeuroInterventional Surgery | October 13, 2021 | Volume: 14 | Issue: 8 | Pages: 783-787

10.1136/neurintsurg-2021-017671 Get It

Background Relationships between occlusive clot histopathology, baseline characteristics, imaging findings, revascularization rates, and clinical outcomes of stroke patients with large vessel occlusion (LVO) are not well understood. This study will assess the real-world experience on the efficacy and safety of using the EmboTrap device as the first approach in LVO patients and explore the associations between clot histological characteristics, imaging and clinical findings, revascularization rates, and clinical outcomes. Methods Prospective, global, multicenter, single-arm, imaging core laboratory, and clot analysis central laboratory observational registry. Adult patients (>18 years) with LVO, treated with EmboTrap as the first attempted device, will be eligible for study participation. Results Up to 1000 subjects at 50 international sites may be enrolled. Occlusive clots will be collected from at least 500 subjects. Independent central and imaging core laboratories will perform clot analysis and image adjudication. Statistical analysis will assess the association between imaging and clinical findings, clot characteristics, subject comorbidities, revascularization, and clinical outcomes. Study endpoints are functional independence (modified Rankin Scale score ≤2 at 90 days), expanded Thrombolysis In Cerebral Infarction (eTICI) score ≥2b50 rate, first-pass effect, number of passes, embolization into new territory, symptomatic intracranial hemorrhage, and 90-day mortality. Conclusions The EXCELLENT registry will provide reproducible effectiveness and safety data of EmboTrap for its use for mechanical thrombectomy. Additionally, the study will characterize the blood clots retrieved during mechanical thrombectomy with respect to their composition and histopathological analysis and potential correlations with clinical and imaging findings. Trial registration number NCT03685578 .