Back to Authors

Cortez, Gustavo M

https://orcid.org/0000-0003-4227-0378

Mayo Clinic

Mount Sinai Health System

Citations 2

Braids and beyond: a comprehensive study on pipeline device braid stability from PREMIER data
Rodriguez‐Erazú, Fernanda , Cortez, Gustavo M , Gutierrez‐Aguirre, Salvador F. , Toledo, Otavio F. De , Aghaebrahim, Amin, Sauvageau, Eric , Kallmes, David F. , Fiehler, Jens , Hanel, Ricardó A. , Gutierrez-Aguirre, Salvador F , De Toledo, Otavio Frederico , Aghaebrahim, Amin , Sauvageau, Eric , Fiehler, Jens , Hanel, Ricardo A , Lopes, Demetrius K.

Journal of NeuroInterventional Surgery | October 2, 2024 | Volume: 17 | Issue: 12 | Pages: 1362-1367

10.1136/jnis-2024-022350 Get It

Background The pipeline embolization device (PED) has been increasingly used to treat brain aneurysms; however, concerns have been raised about braid stability with newer drawn filled tubing technology devices. Objective To evaluate braid stability of PED early generations using data from the PREMIER trial. Methods All consecutive intracranial aneurysms treated with PED (Classic and Flex) within the PREMIER trial were reviewed for braid stability (fish mouthing, foreshortening, braid bump, braid collapsing). Immediate postprocedure cone-beam CT and angiography were compared with 1- and 2- years' follow-up. Analyses included safety, measured with the modified Rankin Scale (mRS) score, including +1 mRS point and a good clinical outcome (mRS score 0–2), vessel stenosis ≥50%, effectiveness measured with Raymond-Roy Scale, and re-treatment rates. Results 133/141 aneurysms had a complete dataset. 8/133 (6%) aneurysms showed braid deformations. Inter-reader agreement was excellent (κ=0.83). Braid deformations were statistically significantly associated with in-stent vessel stenosis >50% (P=0.029), without impact on effectiveness or safety. Fish mouthing was found in 1/133 (0.75%) at 1 year, causing >50% vessel stenosis. Foreshortening occurred in 6/133 (4.5%), and braid bump in 1/133 (0.75%) associated with severe in-stent stenosis. Four other cases (3.0%) of asymptomatic in-stent stenosis due to neointimal hyperplasia were seen without braid changes. No new braid stability deformations were found at the 2-year follow-up. Conclusion Our study demonstrates excellent braid stability among patients treated with the PED Classic and Flex in the PREMIER trial. Within the uncommon braid changes observed, none affected the PED safety or efficacy. Trial registration number NCT02186561 .
Safety and Efficacy of Flow Diverters for Treatment of Unruptured Anterior Communicating Artery Aneurysms: Retrospective Multicenter Study
Benalia, Victor H. C. , Saatçi, Işıl , Cekirge, H Saruhan , Dabus, Guilherme , Brinjikji, Waleed , Nishi, Hidehisa , Siddiqui, Adnan H. , Aghaebrahim, Amin, Sauvageau, Eric , Saatci, Isil , Çekirge, Saruhan , Dabus, Guilherme C. , Nishi, Hidehisa , Monteiro, Andre , Aghaebrahim, Amin , Hanel, Ricardo A , Siddiqui, Adnan H , Cortez, Gustavo M , Mounayer, Charbel , Koçer, Naci , Işlak, Civan , Baltacıoğlu, Feyyaz , Mendes Pereira, Vitor , Lopes, Demetrius K. , Hanel, Ricardó A.

Journal of NeuroInterventional Surgery | October 16, 2023 | Volume: 15 | Issue: 12 | Pages: 1181-1186

10.1136/jnis-2023-020673 Get It

Background The anterior communicating artery (AComm) region is the most common site of intracranial aneurysms, with increased rupture risk compared with other locations. Overall, flow diverters present as a safe and efficacious treatment for intracranial aneurysms, but there is paucity of data for their use in the treatment of unruptured AComm aneurysms. We present the largest multicentric analysis evaluating the outcomes of flow diverters in AComm aneurysm treatment. Methods Databases from 10 centers were retrospectively reviewed for unruptured AComm aneurysms treated with flow diverters. Demographics, clinical presentation, radiographic characteristics, procedural complications, and outcomes were assessed. Results A total of 144 patients harboring 147 AComm aneurysms were treated between January 2012 and December 2021. Seventy-four were women (51.4%) and median age was 60 (IQR 50–67) years. All were unruptured AComm aneurysms. Half of the cohort had similar anterior cerebral artery sizes (51.4%). The most common morphology was saccular (94.6%), with a branch involvement in 32.7% of cases. Median vessel diameter was 2.4 mm, and the Pipeline Flex was the most prevalent device (32.7%). Median follow-up time was 17 months, with complete occlusion in 86.4% at the last follow-up. Functional independence (modified Rankin Scale score 0–2) was reported in 95.1%. Intraprocedural complications occurred in 5.6%, and postoperative complications were noted in 9.7% of cases. Combined major complication and mortality rate was 2.1%. Conclusions Our study suggests that flow diverters are a useful treatment for AComm aneurysms. Mid-term results indicated favorable aneurysm occlusion with a good safety profile. Additional prospective studies with longer follow-up periods and independent adjudication are warranted to better assess these results.