Citations

Mayo Clinic

Clear

83 citation(s) found for "O’Malley, DM".

Bone Growth and Turnover in Progesterone Receptor Knockout Mice
Rickard, David J., Evans, Glenda L., Hefferan, Theresa E., Hunter, Jamie C., Waters, Katrina M. , O’Malley, Bert W. , Khosla, Sundeep , Spelsberg, Thomas C., Turner, Russell T. , Iwaniec, Urszula T. , Lydon, John P. , Khosla, Sundeep

Endocrinology | February 14, 2008 | Volume: 149 | Issue: 5 | Pages: 2383-2390

10.1210/en.2007-1247 | PMID 18276762 Get It

Vascular Endothelial Growth Factor Is Required for Coronary Collateral Growth in the Rat
Toyota, Eiji, Warltier, David C., Brock, Tommy A., Ritman, Erik L., Kolz, Christopher, O’Malley, Peter, Ročić, Petra , Focardi, Marta , Chilian, William M.

Circulation | October 3, 2005 | Volume: 112 | Issue: 14 | Pages: 2108-2113

10.1161/circulationaha.104.526954 | PMID 16203926 Get It

Background— The goal of this study was to determine whether the expression of vascular endothelial growth factor (VEGF) is critical for coronary collateral growth. Previous studies have provided an association between coronary collateral growth and VEGF, but none have allowed determination of a causal role. Methods and Results— We measured coronary collateral growth in rats subjected to repetitive episodes of myocardial ischemia (RI; one 40-second occlusion every 20 minutes for 2 hours 40 minutes, followed by 5 hours 20 minutes of rest, with this 8-hour cycle repeated 3 times per day for 10 days). Collateral growth was measured from blood flow (radioactive microspheres), visualization of arterial-arterial anastomoses (x-ray micro-CT), and maintenance of function during complete coronary occlusion in 3 groups of animals: sham (received instrumentation but no RI), experimental (subjected to RI), and anti–vascular endothelial growth factor (RI+anti-VEGF 0.6 mg/100 g per day) to block the endogenous actions of VEGF. In the 3 groups, native collateral flow (measurement for RI or sham protocol) averaged 0.2 to 0.3 mL · min −1 · g −1 of tissue. In the sham group, collateral flow did not increase during the protocol. Collateral flow in the control RI group increased by ≈6-fold to 1.63 mL · min −1 · g −1 tissue, but in the anti-VEGF group, collateral flow did not increase after the RI protocol (0.22 mL · min −1 · g −1 ). In acute experiments, collateral flow was unchanged during vasodilation with dipyridamole, indicating the increases in collateral flow are due to collateral growth and not vasodilation. X-ray micro-CT analysis revealed a 3-fold increase (versus sham group) in the number of arterial-arterial anastomoses per heart after RI, which was prevented by treatment with anti-VEGF. The growth of the collateral circulation was functional in the RI group because complete coronary occlusion did not induce any untoward effects on hemodynamics or arrhythmias. In the sham or anti-VEGF groups, coronary occlusion at the end of the protocol induced many arrhythmias and deterioration of function. Conclusions— From these results, we conclude that the expression of VEGF is critical to the growth of coronary collaterals.
Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
O’Malley, A. James , Moses, Jeffrey W. , Leon, Martin B. , Holmes, David R. , Teirstein, Paul S., Schofer, Joachim, Breithardt, Günter, Cutlip, Donald E. , Kereiakes, Dean J. , Shi, Chunxue , Firth, Brian G., Donohoe, Dennis, Kuntz, Richard E., Mauri, Laura , Orav, E. John

Circulation | January 18, 2005 | Volume: 111 | Issue: 3 | Pages: 321-327

10.1161/01.cir.0000153356.72810.97 | PMID 15655127 Get It

Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.