Citations

Mayo Clinic

Clear

806 citation(s) found for "Xu, Yong".

Outcome and Management of Pacemaker‐Induced Superior Vena Cava Syndrome
Fu, Hai‐Xia , Huang, Xinmiao , Zhong, Li , Osborn, Michael J., Bjarnason, Haraldur , Mulpuru, Siva K. , Zhao, Xianxian , Friedman, Paul A. , Cha, Yong‐Mei , Bjarnason, Haraldur

Pacing and Clinical Electrophysiology | July 17, 2014 | Volume: 37 | Issue: 11 | Pages: 1470-1476

10.1111/pace.12455 | PMID 25040311 Get It

BackgroundWe aimed to determine the long‐term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker‐induced superior vena cava (SVC) syndrome.MethodsThe study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker‐induced SVC syndrome. Demographic, clinical, and follow‐up characteristics of those patients were collected from electronic medical records.ResultsSix cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual‐chamber pacemakers, with a mean 11‐year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21‐year‐old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow‐up duration was 48 months (range, 10–100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence.ConclusionPercutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker‐induced SVC syndrome, although some cases may require repeat intervention.
Outcomes of Lead Revision for Myocardial Perforation After Cardiac Implantable Electronic Device Placement
Huang, Xinmiao , Fu, Hai‐Xia , Zhong, Li , Osborn, Michael J., Asirvatham, Samuel J. , Sinak, Lawrence J., Cao, Jiang, Friedman, Paul A. , Cha, Yong‐Mei , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 26, 2014 | Volume: 25 | Issue: 10 | Pages: 1119-1124

10.1111/jce.12457 | PMID 24863054 Get It

Percutaneous Lead Revision for Cardiac PerforationIntroductionCardiac perforation is an infrequent but potentially life‐threatening complication associated with placement of a cardiac implantable electronic device (CIED). The objective of this study was to determine the outcomes of percutaneous lead revision in patients who had lead perforation of the myocardium after CIED placement.Methods and ResultsWe reviewed records of 1,458 patients who underwent CIED lead extraction or repositioning. Of these, 31 (2.1%) had the procedure performed for lead perforation as a complication of CIED placement. Demographic, clinical, and follow‐up characteristics of the patients were analyzed. Mean (SD) patient age was 65 (23) years. Cardiac perforation was detected within 24 hours after implantation in 9 patients, within 1 month in 17, and greater than 1 month in 5. Pericardiocentesis was performed with a pigtail drainage catheter in place before the lead revision in 17 patients (55%) who had pericardial effusion, with or without hemodynamic compromise. All culprit leads were successfully managed with percutaneous lead removal (n = 3 [10%]), new lead placement (n = 12 [38%]), or lead repositioning (n = 16 [52%]). Of the 17 patients with pericardiocentesis before the reoperation, none had tamponade develop; in contrast, 3 of the remaining 14 patients had tamponade develop and required urgent pericardiocentesis. All patients survived without requiring open chest surgery.ConclusionPercutaneous removal or repositioning of the perforating lead is feasible and appears effective. Placement of a prophylactic pericardial drain catheter may reduce the incidence of urgent pericardiocentesis during or after a procedure.
Bevacizumab exposure beyond first disease progression in patients with metastatic colorectal cancer: analyses of the ARIES observational cohort study
Grothey, Axel, Flick, E. Dawn, Cohn, Allen Lee, Bekaii‐Saab, Tanios , Bendell, Johanna C. , Kozloff, Mark, Roach, Nancy, Mun, Yong, Fish, Susan, Hurwitz, Herbert I. , Bekaii-Saab, Tanios S

Pharmacoepidemiology and Drug Safety | May 16, 2014 | Volume: 23 | Issue: 7 | Pages: 726-734

10.1002/pds.3633 | PMID 24830357 Get It

ABSTRACTPurposeThis analysis from Avastin® Registries: Investigation of Effectiveness and Safety (ARIES) examined the association between exposure to bevacizumab after disease progression (PD) and postprogression survival (PPS) in bevacizumab‐exposed metastatic colorectal cancer (mCRC) through the application of time‐dependent and time‐fixed analytical methods.MethodsPatients with mCRC who were treated with first‐line bevacizumab and who survived first PD (PD1) were included. A time‐dependent Cox regression model was fitted to assess the effect of cumulative bevacizumab exposure on PPS, while controlling for potential confounders. In addition to support findings from previous studies, a modified intent‐to‐treat (mITT) analysis compared PPS in patients who received bevacizumab beyond disease progression (BBP) with those who did not (No‐BBP).ResultsOf 1550 patients, 1199 survived PD1 and had a median PPS of 13.4 months. Cumulative bevacizumab exposure was associated with improved PPS (p = 0.0040). After adjusting for confounders, the hazard ratios (HRs) for PPS decreased, on average, by 1.2% (range, 1.1–1.3%) with each additional dose of bevacizumab. In the mITT analysis, the median PPS for BBP (n = 438) was 14.4 months vs 10.6 months with for No‐BBP (n = 667). BBP was found to be independently associated with longer PPS in a multivariable Cox regression analysis (HR, 0.84; 95% confidence interval, 0.73–0.97). Protocol‐specified adverse events suspected to be associated with bevacizumab occurred in 13.0% of patients with BBP.ConclusionThis analysis supports the observation that bevacizumab exposure after PD1 is associated with longer PPS in mCRC. Copyright © 2014 John Wiley & Sons, Ltd.
Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads
Higgins, John V., Gard, Joseph J., Espinosa, Raúl E. , Wood, Christopher P. , Felmlee, Joel P. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Dalzell, Connie, Acker, Nancy, Watson, Robert E. , Friedman, Paul A. , Sheldon, Seth H. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591 Get It

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Pathologic heterogeneity persists in early active multiple sclerosis lesions
Metz, Imke , Weigand, Stephen D. , Popescu, Bogdan , Frischer, Josa M. , Parisi, Joseph E. , Guo, Yong , Lassmann, Hans , Brück, Wolfgang , Lucchinetti, Claudia F. , Guo, Yong

Annals of Neurology | April 26, 2014 | Volume: 75 | Issue: 5 | Pages: 728-738

10.1002/ana.24163 | PMID 24771535 Get It

Objective Multiple sclerosis (MS) lesions demonstrate immunopathological heterogeneity in patterns of demyelination. Previous cross‐sectional studies reported immunopatterns of demyelination were identical among multiple active demyelinating lesions from the same individual, but differed between individuals, leading to the hypothesis of intraindividual pathological homogeneity and interindividual heterogeneity. Other groups suggested a time‐dependent heterogeneity of lesions. The objective of our present study was to analyze tissue samples collected longitudinally to determine whether patterns of demyelination persist over time within a given patient. Methods Archival tissue samples derived from patients with pathologically confirmed central nervous system inflammatory demyelinating disease who had undergone either diagnostic serial biopsy or biopsy followed by autopsy were analyzed immunohistochemically. The inclusion criteria consisted of the presence of early active demyelinating lesions—required for immunopattern classification—obtained from the same patient at 2 or more time points. Results Among 1,321 surgical biopsies consistent with MS, 22 cases met the study inclusion criteria. Twenty‐one patients (95%) showed a persistence of immunopathological patterns in tissue sampled from different time points. This persistence was demonstrated for all major patterns of demyelination. A single patient showed features suggestive of both pattern II and pattern III on biopsy, but only pattern II among all active lesions examined at autopsy. Interpretation These findings continue to support the concept of patient‐dependent immunopathological heterogeneity in early MS and suggest that the mechanisms and targets of tissue injury may differ among patient subgroups. These observations have potentially significant implications for individualized therapeutic approaches. Ann Neurol 2014;75:728–738
Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Hu, Tiffany , Ebrille, Elisa , Syed, Faisal F. , Vaidya, Vaibhav R. , Cha, Yong‐Mei , Valverde, Arturo M. , Friedman, Paul A. , Suri, Rakesh M. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975

10.1111/jce.12439 | PMID 24758402 Get It

Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Modulation of Dendritic Cell Differentiation and Maturation by Decoy Receptor 3
Hsu, Tsui-Ling , Chang, Yung-Chi, Chen, Siu-Ju, Chiu, Allen W., Chio, Chung‐Ching , Liu, Yong‐Jun , Chen, Lieping , Hsieh, Shie-Liang Edmond

The Journal of Immunology | April 20, 2014 | Volume: 168 | Issue: 10 | Pages: 4846-4853

10.4049/jimmunol.168.10.4846 | PMID 11994433 Get It

Abstract Decoy receptor 3 (DcR3), a soluble receptor belonging to the TNFR superfamily, is a receptor for both Fas ligand (FasL) and LIGHT. It has been demonstrated that DcR3 is up-regulated in lung and colon cancers, thus promoting tumor growth by neutralizing the cytotoxic effects of FasL and LIGHT. In this study, we found that DcR3.Fc profoundly modulated dendritic cell differentiation and maturation from CD14+ monocytes, including the up-regulation of CD86/B7.2, and the down-regulation of CD40, CD54/ICAM-1, CD80/B7.1, CD1a, and HLA-DR. Moreover, DcR3-treated dendritic cells suppressed CD4+ T cell proliferation in an allogeneic MLR and up-regulated IL-4 secretion of CD4+CD45RA+ T cells. This suggests that DcR3.Fc may act not only as a decoy receptor to FasL and LIGHT, but also as an effector molecule to skew T cell response to the Th2 phenotype.
Paraneoplastic Neuromyelitis Optica Spectrum Disorder Associated With Metastatic Carcinoid Expressing Aquaporin-4
Figueroa, Michelle, Guo, Yong , Tselis, Alexandros, Pittock, Sean J. , Lennon, Vanda A. , Lucchinetti, Claudia F. , Lisak, Robert P. , Pittock, S J , Guo, Yong

JAMA Neurology | April 14, 2014 | Volume: 71 | Issue: 4 | Pages: 495

10.1001/jamaneurol.2013.6331 | PMID 24733266 Get It