Purpose Photon counting detectors (PCDs) are being introduced in advanced x‐ray computed tomography (CT) scanners. From a single PCD‐CT acquisition, multiple images can be reconstructed, each based on only a part of the original x‐ray spectrum. In this study, we investigated whether PCD‐CT can be used to estimate stopping power ratios (SPRs) for proton therapy treatment planning, both by comparing to other SPR methods proposed for single energy CT (SECT) and dual energy CT (DECT) as well as to experimental measurements. Methods A previously developed DECT‐based SPR estimation method was adapted to PCD‐CT data, by adjusting the estimation equations to allow for more energy spectra. The method was calibrated directly on noisy data to increase the robustness toward image noise. The new PCD SPR estimation method was tested in theoretical calculations as well as in an experimental setup, using both four and two energy bin PCD‐CT images, and through comparison to two other SPR methods proposed for SECT and DECT. These two methods were also evaluated on PCD‐CT images, full spectrum (one‐bin) or two‐bin images, respectively. In a theoretical framework, we evaluated the effect of patient‐specific tissue variations (density and elemental composition) and image noise on the SPR accuracy; the latter effect was assessed by applying three different noise levels (low, medium, and high noise). SPR estimates derived using real PCD‐CT images were compared to experimentally measured SPRs in nine organic tissue samples, including fat, muscle, and bone tissues. Results For the theoretical calculations, the root‐mean‐square error (RMSE) of the SPR estimation was 0.1% for the new PCD method using both two and four energy bins, compared to 0.2% and 0.7% for the DECT‐ and SECT‐based method, respectively. The PCD method was found to be very robust toward CT image noise, with a RMSE of 2.7% when high noise was added to the CT numbers. Introducing tissue variations, the RMSE only increased to 0.5%; even when adding high image noise to the changed tissues, the RMSE stayed within 3.1%. In the experimental measurements, the RMSE over the nine tissue samples was 0.8% when using two energy bins, and 1.0% for the four‐bin images. Conclusions In all tested cases, the new PCD method produced similar or better results than the SECT‐ and DECT‐based methods, showing an overall improvement of the SPR accuracy. This study thus demonstrated that PCD‐CT scans will be a qualified candidate for SPR estimations.
Treatment Strategy of a Patient With a Brain Arteriovenous Malformation and Cranial Dural Fistula: 2-Dimensional Operative Video
Abstract We present the case of a 56-yr-old right-handed male, after informed consent was obtained, who presented with acute confusion and agitation, on the background of a remote history of an uncomplicated resection of a left parietal grade 2 glioma. Imaging revealed a large, acute right temporal intracerebral hemorrhage (ICH). Standard vascular workup for the cause of the ICH included catheter angiography. No direct cause of the hemorrhage was revealed; however, a high grade parasagittal dural arteriovenous fistula (DAVF) with cortical venous reflux was noted close to the prior craniotomy site. The venous reflux was towards the left hemisphere, but it was hypothesized that similar reflux on the right side may have been present and was not presently evident due to thrombosis. The DAVF was embolized by endovascular means, followed by evacuation of the hematoma. Follow-up angiogram 7 mo later revealed a high-flow, right superior temporal cortical arteriovenous malformation (AVM). The DAVF unfortunately had also progressed. Endovascular occlusion of both lesions was attempted but was not successful. Subsequently, microsurgical resection for both the vascular malformations was performed with careful pre- and intraoperative planning to obtain a successful clinical and angiographic result. In this video, we summarize diagnostic and therapeutic nuances that have broad implications for the workup of ICH and the strategic management of a unique scenario involving a brain AVM and high-grade cranial dural fistula in the same patient. Prior to each procedure, informed consent was obtained from the patient, which includes consent for publication.
Biomechanical Evaluation of Suture Anchor versus Transosseous Tunnel Patellar Tendon Repair Techniques
Abstract The objective of this study is to compare the cyclic loading strength and ultimate failure load in suture anchor repair versus transosseous tunnel repair of patellar tendons using a cadaver model. Twelve cadaveric patella specimens were used (six matched pairs). Dual-energy X-ray absorptiometry (DXA) measurements were performed to ensure equal bone quality among groups. All right knees were assigned to the suture anchor repair group (n = 6), whereas all left knees were assigned to the transosseous bone tunnel group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 1 Hz between magnitudes of 50 and 150 N, 50 and 200 N, 50 and 250 N, and tensile load at a rate of 0.1 mm/s until failure. Failure was defined as a sharp deviation in the linear load versus displacement curve, and failure mode was recorded. DXA measurements demonstrated equivalence of bone quality between the two groups (p > 0.05). During cyclic load testing, there was only a statistically significant difference between the groups with regard to cyclic loading at the 50 to 200 N loading cycle (p = 0.010). There was no statistically significant difference between the groups with regard to ultimate load to failure (p = 0.43). Failure mode within the suture anchor cohort occurred through anchor pullout except for one, which failed through the tendon. All specimens within the transosseous cohort failed through the midsubstance of the tendon except for one, which failed through suture breakage. Suture anchor repair demonstrated a similar biomechanical profile regarding cyclic loading and ultimate load to failure when compared with “gold standard” transosseous tunnel patellar tendon repair with a trend toward less gapping in the suture anchor group. Using suture anchors for repair of the patella tendon has similar biomechanical properties to transpatellar tunnels but may provide other clinical advantages.
Thyroidectomy for Amiodarone-Induced Thyrotoxicosis: Mayo Clinic Experience
The Selinexor in Advanced Liposarcoma (SEAL) study: A phase 2/3, multicenter, randomized, double blind study of selinexor versus placebo in patients with advanced, unresectable, dedifferentiated liposarcoma (DDLS).
Safety and efficacy of PD-1 blockade using pembrolizumab in patients with advanced soft tissue (STS) and bone sarcomas (BS): Results of SARC028—A multicenter phase II study.
ADVL1315: A phase 1 study of the VEGF receptor tyrosine kinase inhibitor axitinib (INLYTA, IND# 123101) in children with recurrent or refractory solid tumors—A Children's Oncology Group study.