Citations

Mayo Clinic

Clear

58 citation(s) found for "Vm, Pratt".

The PRIDE (Partnership to Improve Diabetes Education) Toolkit
Wolff, Kathleen, Bumol, Stefan, White, Richard O. , Gregory, Becky Pratt, Davis, Dianne, Rothman, Russell L. , Chambers, Laura C.

The Diabetes Educator | December 9, 2015 | Volume: 42 | Issue: 1 | Pages: 23-33

10.1177/0145721715620019 | PMID 26647414 Get It

Purpose Patients with low literacy, low numeracy, and/or linguistic needs can experience challenges understanding diabetes information and applying concepts to their self-management. The authors designed a toolkit of education materials that are sensitive to patients’ literacy and numeracy levels, language preferences, and cultural norms and that encourage shared goal setting to improve diabetes self-management and health outcomes. The Partnership to Improve Diabetes Education (PRIDE) toolkit was developed to facilitate diabetes self-management education and support. Methods The PRIDE toolkit includes a comprehensive set of 30 interactive education modules in English and Spanish to support diabetes self-management activities. The toolkit builds upon the authors’ previously validated Diabetes Literacy and Numeracy Education Toolkit (DLNET) by adding a focus on shared goal setting, addressing the needs of Spanish-speaking patients, and including a broader range of diabetes management topics. Each PRIDE module was evaluated using the Suitability Assessment of Materials (SAM) instrument to determine the material’s cultural appropriateness and its sensitivity to the needs of patients with low literacy and low numeracy. Reading grade level was also assessed using the Automated Readability Index (ARI), Coleman-Liau, Flesch-Kincaid, Fry, and SMOG formulas. Conclusions The average reading grade level of the materials was 5.3 (SD 1.0), with a mean SAM of 91.2 (SD 5.4). All of the 30 modules received a “superior” score (SAM >70%) when evaluated by 2 independent raters. The PRIDE toolkit modules can be used by all members of a multidisciplinary team to assist patients with low literacy and low numeracy in managing their diabetes.
Pharmacogenetic allele nomenclature: International workgroup recommendations for test result reporting
Kalman, LV, Agúndez, JAG, Appell, Malin Lindqvist , Black, J.H., Bell, GC, Boukouvala, Sotiria , Bruckner, Carsten, Bruford, Elspeth A. , Caudle, KE, Coulthard, SA, Daly, Ann K. , Tredici, AL Del, Dunnen, Johan T. den , Drozda, Katarzyna, Everts, Robin E. , Flockhart, David A., Freimuth, Robert R. , Hachad, Houda , Hartshorne, Toinette, Ingelman‐Sundberg, Magnus , Klein, Teri E. , Lauschke, Volker M. , Maglott, DR, McLeod, HL, McMillin, GA, Ua, Meyer, Dj, Müller, Nickerson, D. A., Oetting, WS , Pacanowski, MA, Vm, Pratt, Relling, MV, Roberts, Angharad M. , Ws, Rubinstein, Sangkuhl, Katrin , Schwab, Matthias , Scott, Stuart A. , Sim, SC, Thirumaran, RK, Toji, LH, Tyndale, Rachel F. , Schaik, RHN van, Whirl‐Carrillo, Michelle , Yeo, K. L. B., Zanger, UM, Agúndez, José A. G. , Müller, Daniel J. , Agúndez, JAG, Gaedigk, Andrea , Relling, Mary V. , Toji, Lorraine H., Whirl-Carrillo, Michelle , Agúndez, José A G , Hachad, Houda , Müller, Daniel J , Tyndale, Rachel F , Freimuth, Robert R , Klein, Teri E , Scott, Stuart A , Schwab, Matthias

Clinical Pharmacology & Therapeutics | October 20, 2015 | Volume: 99 | Issue: 2 | Pages: 172-185

10.1002/cpt.280 | PMID 26479518 Get It

This article provides nomenclature recommendations developed by an international workgroup to increase transparency and standardization of pharmacogenetic (PGx) result reporting. Presently, sequence variants identified by PGx tests are described using different nomenclature systems. In addition, PGx analysis may detect different sets of variants for each gene, which can affect interpretation of results. This practice has caused confusion and may thereby impede the adoption of clinical PGx testing. Standardization is critical to move PGx forward.
The Effect of Repetition Rate on Air-Conducted Ocular Vestibular Evoked Myogenic Potentials (oVEMPs)
Bogle, Jamie M. , Zapala, David A., Burkhardt, Brittany, Walker, Kurt, Lundy, Larry, Shelfer, Janet, Pratt, Terri L., Garry, Millicent, Walker, David

American Journal of Audiology | May 21, 2015 | Volume: 24 | Issue: 3 | Pages: 411-418

10.1044/2015_aja-15-0011 | PMID 25997090 Get It

Purpose Ocular vestibular evoked myogenic potentials (oVEMPs) are used to describe utricular/superior vestibular nerve function; however, optimal recording parameters have not been fully established. This study investigated the effect of repetition rate on air-conducted oVEMPs. Method Ten healthy adults were evaluated using 500-Hz tone bursts (4-ms duration, Blackman gating, 122 dB pSPL). Four repetition rates were used (1.6, 4.8, 8.3, and 26.6 Hz) and resulting oVEMP response presence, amplitude, amplitude asymmetry, and n1/p1 latency were assessed. Results Response presence was significantly reduced for 26.6 Hz using monaural stimulation and for 8.3 Hz and 26.6 Hz for binaural stimulation. For monaural stimulation using 1.6, 4.8, and 8.3 Hz, no significant differences were noted for amplitude or latency. Responses obtained using binaural stimulation demonstrated a significant effect of rate on amplitude, with 8.3 Hz producing significantly reduced amplitude. Binaural amplitudes were significantly larger than monaural contralateral responses but with reduced response presence. No significant differences were noted for latency or amplitude asymmetry. Conclusion Using repetition rates of approximately 5 Hz or less may produce more consistent oVEMP response presence with minimal effects on amplitude for monaural or binaural recordings.
Four-Channel ABR Recordings
Pratt, Terri L., Olsen, Wayne O., Bauch, Christopher D.

American Journal of Audiology | July 29, 2014 | Volume: 4 | Issue: 2 | Pages: 47-54

10.1044/1059-0889.0402.47 Get It

Simultaneous four-channel (ipsilateral, contralateral, horizontal, and noncephalic) ABR recordings were reviewed by three audiologists for 187 ears of nontumor patients, and 13 ears of patients having eighth nerve tumors. Waveforms from a subgroup of 63 ears were reexamined by the same audiologists to assess inter- and intra-judge consistency. For nontumor ears, the ipsilateral tracings provided the best identification of Waves I and III; the ipsilateral and noncephalic recordings allowed equal identification of Wave V. Waves I, III, and V generally were more robust from the ipsilateral electrode array than from any of the other electrode montages for the tumor ears. Three-way inter-judge agreement ranged from 82% to 87% for ipsilateral Waves I, III, and V and for noncephalic Wave V. Agreement between pairs of judges ranged from 86% to 100%. Intra-judge agreement ranged from 87% to 94% for ipsilateral Waves I, III, and V, and from 92% to 95% for noncephalic Wave V.
Consistency in Latency Measurements and Interpretation of ABR Tracings
Olsen, Wayne O., Pratt, Terri L., Bauch, Christopher D.

American Journal of Audiology | July 29, 2014 | Volume: 6 | Issue: 1 | Pages: 57-62

10.1044/1059-0889.0601.57 Get It

Multichannel ABR recordings for 30 otoneurologic patients were reviewed independently by three audiologists to assess interjudge consistency in determining absolute latencies and overall interpretation of ABR results. Four months later, the tracings were reviewed a second time to evaluate intrajudge consistency in interpretation of ABR waveforms. Interjudge agreement in marking latencies for waves I, III, and V within 0.2 ms was on the order of 90% or better. Intrajudge consistency was slightly higher. Only rarely did inter- or intrajudge differences in latency measurements exceed 0.3 ms. Agreement in overall interpretation of ABR results as "normal" or "abnormal" was unanimous for 90% of the patients. Across pairs of judges, the agreement for "normal" and "abnormal" classification of the ABR tracings was 97%. Intrajudge consistency for "normal" and "abnormal" categorization of the ABR results was 100% for one judge, 97% for the other two judges.
Variation in the Prevalence of Sarcopenia and Sarcopenic Obesity in Older Adults Associated with Different Research Definitions: Dual‐Energy X ‐Ray Absorptiometry Data from the N
Barré, Laura , MacKenzie, Todd A. , Pratt, Sarah I. , Bartels, Stephen J. , Batsis, John A. , López-Jiménez, Francisco

Journal of the American Geriatrics Society | May 6, 2013 | Volume: 61 | Issue: 6 | Pages: 974-980

10.1111/jgs.12260 | PMID 23647372 Get It

Objectives To determine the prevalence range for sarcopenic obesity and its relationship with sex, age, and ethnicity. Design Cross‐sectional analysis of a population‐based sample. Setting Noninstitutionalized persons in the U nited S tates participating in the N ational H ealth and N utrition E xamination S urveys 1999–2004. Participants Subsample of 4,984 subjects aged 60 and older with dual‐energy X‐ray absorptiometry body composition data. Measurements Eight definitions of sarcopenic obesity identified from six studies found using a systematic literature review ( B aumgartner, B ouchard, D avison, Z oico, L evine, K im‐1,2,3) were applied to the sample. Results were stratified according to sex, age, and ethnicity. Results Prevalence of sarcopenic obesity ranged from 4.4% to 84.0% in men and from 3.6% to 94.0% in women. Prevalence was higher in men using definitions from Baumgartner (17.9% vs 13.3%, P < .001), Levine (14.2% vs 6.6%, P < .001), and Kim‐1 (30.0% vs 9.3%, P < .001); lower for men using the Davison (4.4% vs 11.1%, P < .001) and Kim‐2 (83.7% vs 94.0%) definitions; and the same for men and women using the Bouchard (45.3% vs 44.3%, P = .32) and Kim‐3 (75.6% vs 77.0%, P = .51) definitions. For all but one definition, sarcopenic obesity increased with each decade and was lower in non‐ H ispanic blacks than whites. Conclusion Prevalence of sarcopenic obesity in older adults varies up to 26‐fold depending on current research definitions. Such a high degree of variability suggests the need to establish consensus criteria that can be reliably applied across clinical and research settings.
Evaluation of Mycobacterium avium Complex Clarithromycin Susceptibility Testing Using SLOMYCO Sensititre Panels and JustOne Strips
Hall, Leslie, Abbenyi, Adeline, Eisberner, Justin J., Brown‐Elliott, Barbara A. , Pratt, Cody J., McGlasson, Maria C., Beierle, Keanan D., Wohlfiel, Sherri L., Deml, Sharon M., Wallace, Richard J. , Wengenack, Nancy L. , Babady, N. Esther

Journal of Clinical Microbiology | March 25, 2010 | Volume: 48 | Issue: 5 | Pages: 1749-1752

10.1128/jcm.01936-09 | PMID 20335412 Get It

ABSTRACT The SLOMYCO Sensititre panel and the custom JustOne strip (both from TREK Diagnostic Systems, Cleveland, OH) were evaluated for susceptibility testing of Mycobacterium avium complex isolates against clarithromycin. Seventy-one archived and prospectively collected isolates were tested using both the SLOMYCO panel and the JustOne strip, and the results were compared to those obtained using the BACTEC 460 (BD, Sparks, MD) radiometric method and a broth microdilution reference method. Results obtained by the SLOMYCO panel and the JustOne strip agreed with the BACTEC 460 method for 64/71 isolates (90%). Similarly, concordance with the broth microdilution method was 40/43 isolates (93%) for both test systems. The effect of the source medium on inoculum preparation was evaluated, and there were no differences noted in MICs, regardless of whether the inoculum was prepared from isolates grown in Middlebrook 7H9 medium, on Middlebrook 7H10 agar, or in VersaTREK broth culture bottles (Trek Diagnostics). Clarithromycin susceptibility testing of MAC using the SLOMYCO panel and the JustOne strip methods is easy to set up and simple to read and is readily incorporate into the clinical laboratory. These systems offer advantages over the BACTEC 460 system including the lack of a need for radioactive substrates, sharps, or costly instrumentation.
Genetically Characterized Positive Control Cell Lines Derived from Residual Clinical Blood Samples
Bernacki, Susan H. , Beck, Jeanne C., Stanković, Ana , Williams, Laurina O. , Amos, Jean, Snow-Bailey, Karen, Farkas, Daniel H., Friez, Michael J., Hantash, Feras, Matteson, Karla J., Monaghan, Kristin G. , Muralidharan, Kasinathan, Pratt, Victoria M. , Prior, Thomas W., Richie, Kristy L., Levin, Barbara C., Rohlfs, Elizabeth M., Schaefer, Frederick V., Shrimpton, Antony E., Spector, Elaine , Stolle, Catherine A., Strom, Charles M. , Thibodeau, Stephen N. , Cole, Eugene C., Goodman, Barbara K. , Stenzel, Timothy T.

Clinical Chemistry | September 16, 2005 | Volume: 51 | Issue: 11 | Pages: 2013-2024

10.1373/clinchem.2005.048694 | PMID 16166172 Get It

AbstractBackground: Positive control materials for clinical diagnostic molecular genetic testing are in critically short supply. High-quality DNA that closely resembles DNA isolated from patient specimens can be obtained from Epstein–Barr virus (EBV)–transformed peripheral blood lymphocyte cell lines. Here we report the development of a process to (a) recover residual blood samples with clinically important mutations detected during routine medical care, (b) select samples likely to provide viable lymphocytes for EBV transformation, (c) establish stable cell lines and confirm the reported mutation(s), and (d) validate the cell lines for use as positive controls in clinical molecular genetic testing applications.Methods: A network of 32 genetic testing laboratories was established to obtain anonymous, residual clinical samples for transformation and to validate resulting cell lines for use as positive controls. Three panel meetings with experts in molecular genetic testing were held to evaluate results and formulate a process that could function in the context of current common practices in molecular diagnostic testing.Results: Thirteen laboratories submitted a total of 113 residual clinical blood samples with mutations for 14 genetic disorders. Forty-one EBV-transformed cell lines were established. Thirty-five individual point and deletion mutations were shown to be stable after 20 population doublings in culture. Thirty-three cell lines were characterized for specific mutations and validated for use as positive controls in clinical diagnostic applications.Conclusions: A process for producing and validating positive control cell lines from residual clinical blood samples has been developed. Sustainable implementation of the process could help alleviate the current shortage of positive control materials.