Back to Authors

Olsen, Wayne O.

Mayo Clinic

Mayo Clinic

Citations 14

Bone Conduction Calibration: Current Status
Dirks, Donold D., Lybarger, Samuel F., Olsen, Wayne O., Billings, Bradley L.

Journal of Speech and Hearing Disorders | August 26, 2014 | Volume: 44 | Issue: 2 | Pages: 143-155

10.1044/jshd.4402.143 Get It

Attempts to specify normal threshold sensitivity by bone conduction have been unsuccessful because of problems in obtaining reliable measurements from commercially available artificial mastoids. Recent design modifications incorporated in the Bruel and Kjaer 4930 artificial mastoids have resulted in greater uniformity among these units. However, the new design has resulted in impedances that are higher than those recommended in current standards. Bone-conduction thresholds referenced to measurements made on B x00026 K 4930 artificial mastoids with the new design were performed on 60 normal listeners by three participating laboratories. The results are reported for consideration in the development of a reference threshold for hearing by bone conduction.
Use of TEOAE, ABR, and Acoustic Reflex Measures to Assess Auditory Function Patients With Acoustic Neuroma
Robinette, Martin S., Bauch, Christopher D., Olsen, Wayne O., Harner, Stephen G., Beatty, Charles W.

American Journal of Audiology | July 29, 2014 | Volume: 1 | Issue: 4 | Pages: 66-72

10.1044/1059-0889.0104.66 Get It

Cochlear and neural auditory function for a series of 30 patients with acoustic neuroma was assessed pre- and postoperatively by transiently evoked otoacoustic emission (TEOAE), auditory brain stem response (ABR), and acoustic reflex measures. Employing a retrosigmoid surgical approach, physical integrity of the acoustic nerve was preserved for 22 patients. TEOAEs were observed preoperatively for 13 patients and postoperatively for 6 of them. Postoperative neural function remained unchanged or improved following surgery for 7 patients, and cochlear function decreased. TEOAE, ABR, and acoustic reflex measurements were considered valuable in providing information about site of lesion and probable mechanisms of injury associated with tumor removal.
Four-Channel ABR Recordings
Pratt, Terri L., Olsen, Wayne O., Bauch, Christopher D.

American Journal of Audiology | July 29, 2014 | Volume: 4 | Issue: 2 | Pages: 47-54

10.1044/1059-0889.0402.47 Get It

Simultaneous four-channel (ipsilateral, contralateral, horizontal, and noncephalic) ABR recordings were reviewed by three audiologists for 187 ears of nontumor patients, and 13 ears of patients having eighth nerve tumors. Waveforms from a subgroup of 63 ears were reexamined by the same audiologists to assess inter- and intra-judge consistency. For nontumor ears, the ipsilateral tracings provided the best identification of Waves I and III; the ipsilateral and noncephalic recordings allowed equal identification of Wave V. Waves I, III, and V generally were more robust from the ipsilateral electrode array than from any of the other electrode montages for the tumor ears. Three-way inter-judge agreement ranged from 82% to 87% for ipsilateral Waves I, III, and V and for noncephalic Wave V. Agreement between pairs of judges ranged from 86% to 100%. Intra-judge agreement ranged from 87% to 94% for ipsilateral Waves I, III, and V, and from 92% to 95% for noncephalic Wave V.
Preserved Hearing Following Vestibular Schwannoma Surgery
Bauch, Christopher D., Olsen, Wayne O., Beatty, Charles W., Ebersold, Michael J.

American Journal of Audiology | July 29, 2014 | Volume: 4 | Issue: 3 | Pages: 59-66

10.1044/1059-0889.0403.59 Get It

Audiologic test results were reviewed for 30 patients whose hearing was preserved following eighth nerve tumor surgery. Speech reception thresholds, 4,000-Hz thresholds, acoustic reflexes, and ABR wave I absolute latencies were generally unchanged or poorer following surgery; word recognition scores were essentially unchanged. By contrast, ABR waves III and V, and the I–III and I–V interpeak intervals, were generally improved postoperatively, including several patients who had clear waves following surgery despite absent preoperative responses. The improved ABR tracings likely indicate increased neural synchrony due to reduced pressure on the cochlear nerve following surgery, whereas the reduced hearing sensitivity probably reflects cochlear damage coincident to the surgery.
ABR Indices
Bauch, Christopher D., Olsen, Wayne O., Pool, Angela Flores

American Journal of Audiology | July 29, 2014 | Volume: 5 | Issue: 1 | Pages: 97-104

10.1044/1059-0889.0501.97 Get It

ABR absolute latencies and interpeak intervals were reviewed for 684 non-tumor ears and 75 eighth-nerve tumor ears having various degrees of high frequency hearing loss. For non-tumor ears, the percentage of abnormal absolute latencies for waves I, III, and V increased rather systematically as hearing loss increased, whereas absolute latencies for eighth-nerve tumor ears were largely abnormal regardless of hearing loss. Interpeak intervals were normal for most of the non-tumor ears, but the I–III and I–V intervals were abnormal for most of the tumor ears. The most sensitive index for otoneurologic assessment was a combination of abnormal wave V interaural latency differences or I–V interpeak interval, and the most specific criterion was the I–V interpeak interval. Tumor size influenced sensitivity of most ABR indices.
Consistency in Latency Measurements and Interpretation of ABR Tracings
Olsen, Wayne O., Pratt, Terri L., Bauch, Christopher D.

American Journal of Audiology | July 29, 2014 | Volume: 6 | Issue: 1 | Pages: 57-62

10.1044/1059-0889.0601.57 Get It

Multichannel ABR recordings for 30 otoneurologic patients were reviewed independently by three audiologists to assess interjudge consistency in determining absolute latencies and overall interpretation of ABR results. Four months later, the tracings were reviewed a second time to evaluate intrajudge consistency in interpretation of ABR waveforms. Interjudge agreement in marking latencies for waves I, III, and V within 0.2 ms was on the order of 90% or better. Intrajudge consistency was slightly higher. Only rarely did inter- or intrajudge differences in latency measurements exceed 0.3 ms. Agreement in overall interpretation of ABR results as "normal" or "abnormal" was unanimous for 90% of the patients. Across pairs of judges, the agreement for "normal" and "abnormal" classification of the ABR tracings was 97%. Intrajudge consistency for "normal" and "abnormal" categorization of the ABR results was 100% for one judge, 97% for the other two judges.
Historical Vignette
Olsen, Wayne O.

American Journal of Audiology | July 29, 2014 | Volume: 6 | Issue: 3 | Pages: 5-5

10.1044/1059-0889.0603.05 Get It

Historical Vignette
Olsen, Wayne O.

American Journal of Audiology | July 29, 2014 | Volume: 7 | Issue: 1 | Pages: 14-16

10.1044/1059-0889.0701.14 Get It

Ipsilateral Auditory Pathway Suppression in Dichotic CV Speech Perception
McNeil, Malcolm R. , Pettit, John M., Olsen, Wayne O.

Journal of Speech and Hearing Disorders | July 29, 2014 | Volume: 46 | Issue: 1 | Pages: 87-90

10.1044/jshd.4601.87 Get It

The exact nature of ipsilateral auditory pathway suppression under dichotic stimulation remains controversial. To help resolve this controversy, the distinctive feature confusions (blend vs nonblend errors) made on a dichotic listening CV test by two hemispherectomees were analyzed. Results support ipsilateral auditory pathway suppression under dichotic CV stimulation. Ipsilateral auditory pathway suppression is discussed in terms of stimulus specificity, subject, and task difference.
Application of Silman and Gelfand (1981) 90th Percentile Levels for Acoustic Reflex Thresholds
Olsen, Wayne O., Bauch, Christopher D., Harner, Stephen G.

Journal of Speech and Hearing Disorders | July 29, 2014 | Volume: 48 | Issue: 3 | Pages: 330-332

10.1044/jshd.4803.330 Get It