Citations

Mayo Clinic

Clear

54 citation(s) found for "Rajendran, P".

High-Resolution Chest Computed Tomography Imaging of the Lungs
Bartlett, David J. , Koo, Chi Wan , Bartholmai, Brian J. , Weaver, Jayse , Halaweish, Ahmed F., Bartholmai, Brian J , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | November 21, 2018 | Volume: 54 | Issue: 3 | Pages: 129-137

10.1097/rli.0000000000000524 | PMID 30461437 Get It

Objectives The aim of this study was to evaluate if a high-resolution photon-counting detector computed tomography (PCD-CT) system with a 1024×1024 matrix reconstruction can improve the visualization of fine structures in the lungs compared with conventional high-resolution CT (HRCT). Materials and Methods Twenty-two adult patients referred for clinical chest HRCT (mean CTDI vol, 13.58 mGy) underwent additional dose-matched PCD-CT (mean volume CT dose index, 13.37 mGy) after written informed consent. Computed tomography images were reconstructed at a slice thickness of 1.5 mm and an image increment of 1 mm with our routine HRCT reconstruction kernels (B46 and Bv49) at 512 and 1024 matrix sizes for conventional energy-integrating detector (EID) CT scans. For PCD-CT, routine B46 kernel and an additional sharp kernel (Q65, unavailable for EID) images were reconstructed at 1024 matrix size. Two thoracic radiologists compared images from EID and PCD-CT noting the highest level bronchus clearly identified in each lobe of the right lung, and rating bronchial wall conspicuity of third- and fourth-order bronchi. Lung nodules were also compared with the B46/EID/512 images using a 5-point Likert scale. Statistical analysis was performed using a Wilcoxon signed rank test with a P < 0.05 considered significant. Results Compared with B46/EID/512, readers detected higher-order bronchi using B46/PCD/1024 and Q65/PCD/1024 images for every lung lobe (P < 0.0015), but in only the right middle lobe for B46/EID/1024 (P = 0.007). Readers were able to better identify bronchial walls of the third- and fourth-order bronchi better using the Q65/PCD/1024 images (mean Likert scores of 1.1 and 1.5), which was significantly higher compared with B46/EID/1024 or B46/PCD/1024 images (mean difference, 0.8; P < 0.0001). The Q65/PCD/1024 images had a mean nodule score of 1 ± 1.3 for reader 1, and −0.1 (0.9) for reader 2, with one reader having improved nodule evaluation scores for both PCD kernels (P < 0.001), and the other reader not identifying any increased advantage over B46/EID/1024 (P = 1.0). Conclusions High-resolution lung PCD-CT with 1024 image matrix reconstruction increased radiologists' ability to visualize higher-order bronchi and bronchial walls without compromising nodule evaluation compared with current chest CT, creating an opportunity for radiologists to better evaluate airway pathology.
150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology
Rajendran, Kishore , Gong, Hao , Zhou, Wei , Halaweish, Ahmed F., Henning, André , Kappler, S. , Baer, Matthias , Rajendran, Kishore , Zhou, Wei , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Investigative Radiology | May 31, 2018 | Volume: 53 | Issue: 11 | Pages: 655-662

10.1097/rli.0000000000000488 | PMID 29847412 Get It

Objective The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. Materials and Methods This Health Insurance Portability Act–compliant study was approved by our institutional review board. Two high–spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. Results Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 μm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. Conclusions Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.
Measuring arterial wall perfusion using photon-counting computed tomography (CT): improving CT number accuracy of artery wall using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Anderson, Jill , Halaweish, Ahmed F., Abdurakhimova, Dilbar, Ritman, Erik L., Anderson, Jill L, McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 8, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.044006 | PMID 29250564 Get It

Detection of increased vasa vasorum in artery walls: improving CT number accuracy using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Abdurakhimova, Dilbar, Ritman, Erik L., Leng, Shuai , McCollough, Cynthia H. , Rajendran, Kishore

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323O

10.1117/12.2255676 | PMID 28413240 Get It