Citations

Mayo Clinic

Clear

86 citation(s) found for "Kushwaha, S".

Exercise-induced hypoxemia predicts heart failure hospitalization and death in patients supported with left ventricular assist devices
Koerber, Daniel M. , Rosenbaum, Andrew , Olson, Thomas P. , Kushwaha, Sudhir S. , Stulak, John M., Maltais, Simon, Behfar, Atta , Rosenbaum, Andrew N , Kushwaha, Sudhir, Behfar, Atta

The International Journal of Artificial Organs | October 19, 2019 | Volume: 43 | Issue: 3 | Pages: 165-172

10.1177/0391398819882435 | PMID 31630619 Get It

Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise–induced hypoxemia (O 2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4–57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO 2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6–322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.
Sequential Heart and Autologous Stem Cell Transplantation for AL Amyloidosis.
Lacy, Martha Q. , Hayman, Suzanne R. , Kumar, Shaji , Kyle, Robert A. , Edwards, Brooks S., Rodeheffer, Richard J. , Robert, Frantz P., Kushwaha, Sudhir S. , Clavell, Alfedo L., Sundt, Thoralf M. , Daly, Richard C. , McGregor, Christopher G.A. , Gastineau, Dennis A. , Dispenzieri, Angela , Rajkumar, S. Vincent , Dearani, Joseph A. , Gertz, Morie A.

Blood | October 11, 2019 | Volume: 108 | Issue: 11 | Pages: 3092-3092

10.1182/blood.v108.11.3092.3092 Get It

Abstract Background: Patients with AL and congestive heart failure have a median survival of less than one year. Methods: Between 1994 and 2005, 11 patients underwent sequential heart transplant followed by autologous peripheral blood stem cell transplant (SCT) for treatment of AL. Patients had heart dominant AL with minimal/no other organ impairment and no evidence of multiple myeloma. Results: Patients ranged in age from 35 to 63 years (median 54). All had biopsy proven amyloidosis and monoclonal protein detectable in serum (73%) or urine (100%). Free light chain assay was available prior to SCT in 6 and was abnormal in all. All patients presented with NYHA Class III or IV heart failure. All but two patients had no other organ involved at the time of heart transplant. One patient had his heart transplant at another facility and had renal involvement at the time of heart transplant. One patient had peripheral nerve involvement documented prior to heart transplant. Five patients had progression of amyloid to involve other organs by the time of SCT. These included: renal (6), peripheral nerve (2), macroglossia (3), gastrointestinal (2). The median time from diagnosis to heart transplant was 3 months (range 1 to 5). The median time from heart transplant to SCT was 8 months, (range 3 to 24). Conditioning chemotherapy consisted of melphalan 200 mg /m2 (6 patients) or melphalan 140 mg/m2 (5 patients). Two patients died of complications before day +100, (TRM of 18%). Hematologic remissions were seen in 8 and organ responses in 3. Five were unable to be evaluated for organ response due to the heart transplant. Three died from progressive amyloidosis at 66, 56.7, and 55 months following SCT. The median survival is 56.7 months from SCT. Six are alive with a median follow-up of 24 months, range 9 to 90 months. Among the 6 surviving patients, one patient relapsed and one patient has failed to improve, but 4 patients are in continued remission. One patient developed secondary myelodysplastic syndrome. Conclusions: Heart transplant followed by SCT is feasible and offers durable remissions for carefully selected patients with cardiac AL. Figure Figure
Diastolic Pulmonary Gradient as a Predictor of Right Ventricular Failure After Left Ventricular Assist Device Implantation
Alnsasra, Hilmi , Schettle, Sarah , Pereira, Naveen L. , Frantz, Robert P. , Edwards, Brooks S., Clavell, Alfredo L. , Maltais, Simon, Daly, Richard C. , Stulak, John M., Rosenbaum, Andrew , Behfar, Atta , Kushwaha, Sudhir S. , Asleh, Rabea , Schettle, Sarah D., Rosenbaum, Andrew N , Behfar, Atta , Frantz, Robert P

Journal of the American Heart Association | August 14, 2019 | Volume: 8 | Issue: 16 | Pages: No page available

10.1161/jaha.119.012073 | PMID 31411097 Get It

Background Diastolic pulmonary gradient ( DPG ) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance ( PVR ) and transpulmonary gradient ( TPG ). The prognostic significance of DPG in patients requiring a left ventricular assist device ( LVAD ) remains unclear. We sought to investigate whether pre‐ LVAD DPG is a predictor of survival or right ventricular ( RV ) failure post‐ LVAD . Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all‐cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan–Meier analyses. After a mean follow‐up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [ HR ]: 3.30; P =0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR ( HR 1.85, P =0.13 for PVR ≥3 versus PVR <3) or TPG ( HR 1.47, P =0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk ( HR 1.16, P =0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR , but not TPG , was associated with higher mortality risk ( HR 1.55; P =0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
Cross, Troy J. , Sajgalik, Pavol , Fabián, Vratislav , Matera, Lukáš , Kushwaha, Sudhir S. , Maltais, Simon, Stulak, John M., Schirger, John A., Johnson, Bruce D. , Cross, Troy James

The International Journal of Artificial Organs | August 14, 2019 | Volume: 43 | Issue: 2 | Pages: 99-108

10.1177/0391398819868236 | PMID 31411101 Get It

Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m −2 ) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.
Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
Rosenbaum, Andrew , Frantz, Robert P. , Kushwaha, Sudhir S. , Stulak, John M., Maltais, Simon, Behfar, Atta , Rosenbaum, Andrew N , Behfar, Atta , Frantz, Robert P

Journal of the American Heart Association | February 13, 2019 | Volume: 8 | Issue: 4 | Pages: No page available

10.1161/jaha.118.010232 | PMID 30755070 Get It

Background Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cf LVADs ). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. Methods and Results To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cf LVAD was developed. Patients implanted with cf LVAD s underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient ( TAG ) was established. Thirty eight patients with cf LVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG . A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. Conclusions Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cf LVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.
Pulmonary Function Assessment Post-Left Ventricular Assist Device Implantation
Sajgalik, Pavol , Kim, Chul‐Ho , Stulak, John M., Kushwaha, Sudhir S. , Maltais, Simon, Joyce, David L. , Joyce, Lyle D., Johnson, Bruce D. , Schirger, John A.

ESC Heart Failure | October 12, 2018 | Volume: 6 | Issue: 1 | Pages: 53-61

10.1002/ehf2.12348 | PMID 30311748 Get It

Abstract Aim The lungs—and particularly the alveolar-capillary membrane—may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function. Methods and results We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)] and diffusing capacity of the lung for carbon monoxide (DLCO) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (−23%) since pre-implantation (P &lt; 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P &lt; 0.01) and ΔDLCO to ΔRAP (r = 0.39, P &lt; 0.05). We observed other reductions in FEV1, FVC, and FEV1/FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1/FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28–0.98); P = 0.03]. Conclusions Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.
International Analysis of LVAD Point-of-Care Versus Plasma INR: A Multicenter Study
Schettle, Sarah , Schlöglhofer, Thomas , Zimpfer, Daniel , Salimbangon, A., Wolforth, Jennifer, Schroeder, Sarah E. , Hards, Rachel, Ritchie, Brianne M., Staley, Linda L., Pereira, Naveen L. , Kushwaha, Sudhir S. , Maltais, Simon, Stulak, John M., Ritchie, Brianne, Staley, Linda, Kushwaha, Sudhir, Schima, Heinrich , Kaufmann, Friedrich , Zimpfer, Daniel

ASAIO Journal | September 8, 2018 | Volume: 64 | Issue: 6 | Pages: e161-e165

10.1097/mat.0000000000000845 | PMID 30199385 Get It

International normalized ratio (INR) measurements manage risks of bleeding and clotting sequelae in the population with left ventricular assist device (LVAD). Studies suggest that point-of-care (POC) INR does not significantly differ from plasma INR (P-INR) values in other patient populations, although this has not been validated in a multicenter LVAD study. We sought to determine whether POC-INR and P-INR values differ significantly in the LVAD population and reviewed patients with permanent LVAD implantation at seven institutions internationally. Our cohort comprised of 279 paired POC-INR and P-INR checks in patients supported on average 630 ± 598 days postimplant with predominately HeartWare, HeartMate II, and HeartMate III devices. The population averaged 57.9 years of age, and there were 86.7% male. We found no statistically significant difference between POC-INR and P-INR values. International normalized ratio accuracy correlated weakly with the time between INR measurements (p < 0.001). When the time difference was less than 4 hours, the difference between INR pairs was significantly lower than measurements greater than 8 hours (p = 0.006). There was no statistically significant difference when comparing paired INR values and time after implant to INR check (p = 0.43), age (p = 0.12), known coagulopathy (p = 0.12), bleeding history (p = 0.22), or thrombosis history (p = 0.34). This is the first large multicenter international study comparing POC-INR and P-INR measurements in patients with LVAD and found no statistically significant difference between either methods, particularly when measured within less than 4 hours of each other.
Genomewide association study reveals novel genetic loci associated with change in renal function in heart transplant recipients
Asleh, Rabea , Snipelisky, David , Hathcock, Matthew , Kremers, Walter K. , Liu, Duan , Batzler, Anthony , Jenkins, Gregory D. , Kushwaha, Sudhir S. , Pereira, Naveen L. , Jenkins, Gregory, Kushwaha, Sudhir, Asleh, Rabea , Kremers, Walter K , Liu, Duan

Clinical Transplantation | August 30, 2018 | Volume: 32 | Issue: 10 | Pages: No page available

10.1111/ctr.13395 | PMID 30160337 Get It

AbstractBackgroundRenal dysfunction occurs commonly after heart transplantation (HTx) with wide inter‐individual variability but whether a genetic predisposition exists in these patients is unknown. Genomewide association studies (GWAS) have not been performed to assess the association of genetic variation with change in renal function after HTx.MethodsClinical and demographic data of patients who underwent HTx and provided blood samples and consent for genetic analysis were included. Genotyping was performed using Illumina Infinium Human CoreExome v1.0 analysis kit. A GWAS utilizing linear regression models was performed with estimated glomerular filtration rate (eGFR) at 1 year as the phenotype after adjusting for baseline eGFR prior to HTx and conversion from calcineurin inhibitor to sirolimus as primary immunosuppression therapy.ResultsA total of 251 HTx recipients were genotyped for 314,903 single nucleotide polymorphisms (SNPs). The mean (SD) age was 50 (12.5) years; most patients were of European origin (n = 243, 96.8%) and males (n = 179, 71.3%). After adjustment for potential confounders, two variants, rs17033285 (P = 4.3 × 10−7) and rs4917601 (P = 6.46 × 10−7), in a long non‐coding RNA (lncRNA) gene LINC01121 and a pseudogene BTBD7P2, were identified to have a significant association with change in GFR at 1 year after HTx.ConclusionsOur first of its kind GWAS demonstrates that genetic variation affects renal function after HTx independent of other risk factors. Agnostic genetic approaches such as these may lead to identification of novel biological pathways such as the role of lncRNAs in the development of renal dysfunction post‐HTx.
Timing of 3-Hydroxy-3-Methylglutaryl-Coenzyme A Reductase Inhibitor Initiation and Allograft Vasculopathy Progression and Outcomes in Heart Transplant Recipients
Briasoulis, Αlexandros , Pereira, Naveen L. , Boilson, Barry A. , Edwards, Brooks S., Adigun, Rosalyn , Maltais, Simon, Daly, Richard C. , Kushwaha, Sudhir S. , Asleh, Rabea , Briasoulis, Alexandros , Lerman, Amir

ESC Heart Failure | July 18, 2018 | Volume: 5 | Issue: 6 | Pages: 1118-1129

10.1002/ehf2.12329 | PMID 30019530 Get It

Abstract Aims Early studies from the 1990s have shown that statins improve survival and attenuate cardiac allograft vasculopathy (CAV). However, little contemporary data are available on the incremental benefit of statins with the current use of new-generation immunosuppressive agents and the use of coronary intravascular ultrasound for assessment of CAV. We sought to investigate the effect of early statin (ES) as compared with late statin (LS) initiation after heart transplantation (HT) on long-term CAV progression and clinical outcomes in a large contemporary HT cohort. Methods and results We analysed a cohort of 409 adult HT recipients. CAV progression was assessed by serial coronary intravascular ultrasound volumetric measurements of the differences between baseline and last follow-up plaque volume (PV) and plaque index (PV/vessel volume ratio). CAV progression and clinical outcomes were compared between the ES (&lt;2 years after HT) and the LS (&gt;2 years after HT) groups. During a median follow-up of 8.2 years, ES resulted in significantly lower change (Δ) of plaque index (+3.8% ± 1.7% vs. +8.2% ± 3.6%; P = 0.0008) and PV (+0.8 ± 0.3 vs. +1.9 ± 1.2; P = 0.045) compared with LS group. In a Cox proportional hazards regression model and after adjustment for baseline characteristics, ES was associated with a 52% decreased risk of CAV-associated events (hazard ratio 0.48, 95% confidence interval: 0.27–0.91; P = 0.025) and a 42% decreased risk of the composite endpoint of all-cause mortality and CAV-associated events (hazard ratio 0.58, 95% confidence interval: 0.38–0.91; P = 0.019). Conclusions Early initiation of statin therapy after HT results in attenuated CAV progression as well as in decreased CAV-related events and mortality.
Elevated ST2 levels are associated with antibody‐mediated rejection in heart transplant recipients
Grupper, Avishay , AbouEzzeddine, Omar F. , Maleszewski, Joseph J. , Grupper, Ayelet , Geske, Jennifer R. , Kremers, Walter K. , Kushwaha, Sudhir S. , Pereira, Naveen L. , Kremers, Walter K , Geske, Jennifer , AbouEzzeddine, Omar F

Clinical Transplantation | July 12, 2018 | Volume: 32 | Issue: 9 | Pages: No page available

10.1111/ctr.13349 | PMID 29998506 Get It

AbstractSoluble ST2 (sST2) is a novel biomarker of inflammation and fibrosis. Elevated sST2 levels (≥35 ng/mL) are associated with worse outcomes in patients with heart failure (HF). There are sparse data regarding the significance of sST2 levels after heart transplantation (HTx). The study aims were to evaluate trends in soluble ST2 levels after the resolution of HF status with HTx and association between post‐HTx sST2 levels and outcomes. Plasma sST2 levels were measured at baseline (median [IQR] of 118 days pre‐HTx) and 12 months post‐HTx in 62 subjects who were stratified into two groups by post‐HTx sST2 levels < or ≥35 ng/mL: “Group 1” or “Group 2,” respectively. Plasma sST2 levels were elevated in 58% of patients pre‐HTx and in 50% of patients post‐HTx. There was no association between elevated sST2 levels before and after HTx, and no significant differences in baseline characteristics between Group 1 and Group 2 patients. Group 2 as compared to Group 1 HTx recipients had significantly higher incidence of antibody‐mediated rejection (AMR) for the entire post‐transplant follow‐up period (32% vs 4%, P = 0.006). There was no association between post‐HTx sST2 level status and other post‐HTx outcomes including survival. In conclusion, elevated plasma sST2 levels after HTx are associated with increased risk for AMR.