Citations

Mayo Clinic

Clear

560 citation(s) found for "Yu, Mei".

Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Zyl, Martin van , Aung, Htin , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Mulpuru, Siva K. , Cha, Yong‐Mei , Espinosa, Raúl E. , Asirvatham, Samuel J. , McLeod, Christopher J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 | PMID 28543771 Get It

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Poly(GP) proteins are a useful pharmacodynamic marker for C9ORF72 -associated amyotrophic lateral sclerosis
Chew, Jeannie , Stankowski, Jeannette N. , Hayes, Lindsey R. , Zhang, Yong‐Jie , Prudencio, Mercedes , Carlomagno, Yari , Daughrity, Lillian M. , Jansen‐West, Karen , Perkerson, Emilie A., O’Raw, Aliesha D. , Cook, Casey , Pregent, Luc , Belzil, Véronique , Blitterswijk, Marka van , Tabassian, Lilia J., Lee, Chris W. , Yue, Mei, Tong, Jimei, Song, Yuping , Castanedes‐Casey, Monica , Rousseau, Linda , Phillips, Virginia , Rademakers, Rosa , Fryer, John Denis , Rush, Beth , Pedraza, Otto , Caputo, Ana M., Desaro, Pamela , Palmucci, Carla, Robertson, A. , Diehl, Nancy N. , Wiggs, Edythe, Tierney, Michael , Braun, Laura, Farren, Jennifer, Lacomis, David , Fournier, Christina , McCluskey, Leo, Elman, Lauren , Toledo, Jon B. , McBride, Jennifer D. , Tiloca, Cinzia , Morelli, Claudia , Poletti, Barbara , Solca, Federica , Wuu, Joanne , Jockel‐Balsarotti, Jennifer , Rigo, Frank , Ambrose, Christine, Yang, Weixing , Raitcheva, Denitza , Antognetti, Giovanna, McCampbell, Alexander , Boxer, Adam L. , Brown, Robert H. , Bowser, Robert , Miller, Timothy M. , Trojanowski, John Q. , Hu, William T. , Ratti, Antonia , Benatar, Michael , Glass, Jonathan D. , Floeter, Mary Kay, Petrucelli, Leonard , Gendron, Tania F. , Zhang, Yong-Jie , Prudencio, Mercedes , Carlomagno, Yari , Jansen-West, Karen, O'Raw, Aliesha , Pregent, Luc , Belzil, Veronique , van Blitterswijk, Marka , Castanedes-Casey, Monica , Rousseau, Linda , Phillips, Virginia , Rademakers, Rosa , Fryer, John D., Desaro, Pamela , Palmucci, Carla , Robertson, Amelia , Lacomis, David , Ladha, Shafeeq , Tiloca, Cinzia , Poletti, Barbara , Solca, Federica , Prelle, Alessandro , Jockel-Balsarotti, Jennifer , Yang, Weixing , Raitcheva, Denitza , Benatar, Michael , Silani, Vincenzo , Boylan, Kevin B, Petrucelli, Leonard , Dickson, Dennis W. , Heckman, Michael G. , Ladha, Shafeeq , Datta, Abhishek , Swieten, John C. van , Miller, Bruce L. , Grossman, Murray , Berry, James D. , Traynor, Bryan J. , Disney, Matthew D. , Silani, Vincenzo , Rothstein, Jeffrey D. , Boylan, Khrista , Hu, William T.

Science Translational Medicine | March 29, 2017 | Volume: 9 | Issue: 383 | Pages: No page available

10.1126/scitranslmed.aai7866 | PMID 28356511 Get It

Poly(GP) proteins are a promising pharmacodynamic marker for developing and testing therapeutics for treating C9ORF72 -associated amyotrophic lateral sclerosis.
Abstract OT2-03-03: A randomized trial of 15 fraction vs 25 fraction pencil beam scanning proton radiotherapy after mastectomy in patients requiring regional nodal irradiation
Mutter, R.W., Hieken, TJ, Vargas, C., Mei-Yin, PC, Kathryn, RJ, Hector, VR, Kimberly, CS, Elizabeth, YS, Daniel, VW, Park, SS

Cancer Research | March 1, 2017 | Volume: 77 | Issue: 4_Supplement | Pages: OT2-03-03-OT2-03-03

10.1158/1538-7445.sabcs16-ot2-03-03 Get It

Abstract Background: Post-mastectomy radiotherapy improves survival in women with node-positive breast cancer. Pencil beam scanning proton therapy is attractive due to potential to reduce the dose to the heart and lungs compared with traditional photon techniques while improving conformality and limiting skin dose compared with passively scanned proton therapy. The optimal dose and fractionation for pencil-beam scanning proton therapy remains unknown. Trial Design: This is a multi-center open label phase II randomized controlled trial to determine the safety of 15 fraction vs 25 fraction pencil beam scanning proton radiotherapy after mastectomy in patients requiring regional nodal irradiation. Eligibility Criteria: Patients ≥ 18 years with primary, non-inflammatory invasive breast cancer who have undergone mastectomy with or without immediate reconstruction and chest wall and regional nodal irradiation planned. Aims: To determine whether the 24 month complication rate (defined as grade 3 or greater late adverse events, and unplanned surgical intervention in patients who undergo mastectomy with reconstruction) of 15 fraction chest wall and regional node pencil beam scanning proton radiotherapy is acceptable relative to 25 fraction chest wall and regional nodal pencil beam scanning proton radiotherapy and worthy of further investigation. Statistical methods: The study is designed as a non-inferiority/superiority “hybrid” design using the approach of Freidlin et al. It is Using a one-sided type I error rate of 0.05 (corresponding equivalently to constructing a 1-sided 95% confidence limit), 72 evaluable patients will have 80% power to reject the null hypothesis that the 24-month complication rate in the experimental arm is higher than that of the control arm by more than 10% (i.e. rule out inferiority) under the alternative hypothesis that the complication rate in the experimental arm is 5% less than that of the control arm (i.e. superiority). However, the design will have only 41% power when the two treatment arms are equivalent (i.e. the complication rate is 10% for both arms). Accrual: The study opened in June 2016. Five of a planned eighty-two patients have been accrued to date. Citation Format: Mutter RW, Park SS, Hieken TJ, Vargas CE, Mei-Yin PC, Kathryn RJ, Hector VR, Kimberly CS, Elizabeth YS, Daniel VW. A randomized trial of 15 fraction vs 25 fraction pencil beam scanning proton radiotherapy after mastectomy in patients requiring regional nodal irradiation [abstract]. In: Proceedings of the 2016 San Antonio Breast Cancer Symposium; 2016 Dec 6-10; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2017;77(4 Suppl):Abstract nr OT2-03-03.
Incidence of Idiopathic Ventricular Arrhythmias
Sirichand, Surksha , Killu, Ammar M. , Padmanabhan, Deepak , Hodge, David O. , Chamberlain, Alanna M. , Brady, Peter A. , Packer, Douglas L. , Munger, Thomas M. , Shen, Win-Kuang, Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Kapa, Suraj , Noseworthy, Peter A. , Gersh, Bernard J. , McLeod, Christopher J. , Asirvatham, Samuel J , Chamberlain, Alanna M

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 | PMID 28183845 Get It

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Okamura, Hideo , Padmanabhan, Deepak , Watson, Robert E. , Dalzell, Connie, Acker, Nancy, Jondal, Mary Lou, ROMME, ABBY L., Cha, Yong‐Mei , Asirvatham, Samuel J. , Felmlee, Joel P. , Friedman, Paul A. , Jondal, Mary, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 | PMID 28169434 Get It

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Impact of a Care Process Model on Management of Cardiovascular Implantable Electronic Device Infections
Anderson, Brenda, Linderbaum, Jane A. , Ziel, Thomas De, Cha, Yong‐Mei , Loomis, Erica, Espinosa, Raúl E. , Friedman, Paul A. , Greason, Kevin L. , Schiller, Henry J., Virk, Abinash , Wilson, Walter R. , Steckelberg, James M., Tan, Eugene M. , Nagpal, Avish , DeSimone, Daniel C. , Li, Zhuo , Sohail, M. Rizwan , Baddour, Larry M.

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.811 Get It

Impact of a Primary Inpatient Electrophysiology Service on Cardiovascular Implantable Electronic Device Infections in a Tertiary Care Hospital
Anderson, Brenda, Linderbaum, Jane A. , Ziel, Thomas De, Li, Zhuo, Cha, Yong‐Mei , Loomis, Erica, Espinosa, Raúl E. , Friedman, Paul A. , Greason, Kevin L. , Schiller, Henry J., Virk, Abinash , Wilson, Walter R., Steckelberg, James M., Tan, Eugene M. , Nagpal, Avish , DeSimone, Daniel C. , Sohail, M. Rizwan , Baddour, Larry M.

Open Forum Infectious Diseases | February 2, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.810 Get It

Discovery of Novel Dual Vegfr2 and Src Inhibitors Using a Multistep Virtual Screening Approach
Chen, Shangying , Chu, Qin , Sin, Jia En, Yang, Xuan , Zeng, Xian , Zhang, Peng , Gao, Chun Mei, Zhang, Cheng , Chen, Yu , Chui, Wai Keung, Tao, Lin , Jiang, Yu , Zhang, Cheng

Future Medicinal Chemistry | December 20, 2016 | Volume: 9 | Issue: 1 | Pages: 7-24

10.4155/fmc-2016-0162 | PMID 27995811 Get It