Citations

Mayo Clinic

Clear

541 citation(s) found for "Bailey, Baños".

Serum N -Terminal Pro-B-Type Natriuretic Peptide Levels Are Associated With Functional Capacity in Patients With Peripheral Arterial Disease
Fan, Jin, Jouni, Hayan, Khaleghi, Mahyar, Bailey, Kent R. , Fan, Jin, Kullo, Iftikhar J.

Angiology | November 17, 2011 | Volume: 63 | Issue: 6 | Pages: 435-442

10.1177/0003319711423095 | PMID 22096207 Get It

We hypothesized that higher serum levels of N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) are associated with lower functional capacity in patients with peripheral arterial disease ([PAD] n = 481, mean age 67, 68% men). Functional capacity was quantified as distance walked on a treadmill for 5 minutes. Patients were divided into 3 groups according to the distance walked: >144 yards (group 1, n = 254); 60 to 144 yards (group 2, n = 80); <60 yards or did not walk (group 3, n = 147). The association between NT-pro-BNP levels and the ordinal 3-level walking distance was assessed using multivariable ordinal logistic regression analyses that adjusted for several possible confounding variables. Higher levels of NT-pro-BNP were associated with a lower ordinal walking category independent of possible confounders (odds ratio [OR] 1.51, 95% confidence interval [CI] 1.28-1.77; P < .001). In conclusion, higher levels of NT-pro-BNP are independently associated with lower functional capacity in patients with PAD and may be a marker of hemodynamic stress in these patients.
Heparin and warfarin anticoagulation intensity as predictors of recurrence after deep vein thrombosis or pulmonary embolism: a population-based cohort study
Heit, John A. , Lahr, Brian D. , Petterson, Tanya M. , Bailey, Kent R. , Ashrani, Aneel A. , Melton, L. Joseph

Blood | September 4, 2011 | Volume: 118 | Issue: 18 | Pages: 4992-4999

10.1182/blood-2011-05-357343 | PMID 21890644 Get It

Abstract To test recommended anticoagulation measures as predictors of 180-day venous thromboembolism (VTE) recurrence, we identified all Olmsted County, MN residents with incident VTE over the 14-year period of 1984-1997, and followed each case (N = 1166) forward in time for VTE recurrence. We tested the activated partial thromboplastin time (APTT), international normalized ratio (INR), and other measures of heparin and warfarin anticoagulation as predictors of VTE recurrence while controlling for baseline and time-dependent characteristics using Cox proportional hazards modeling. Overall, 1026 (88%) and 989 (85%) patients received heparin and warfarin, respectively, and 85 (8%) developed VTE recurrence. In multivariable analyses, increasing proportions of time on heparin with an APTT ≥ 0.2 anti-Xa U/mL and on warfarin with an INR ≥ 2.0 were associated with significant reductions in VTE recurrence, while the hazard with active cancer was significantly increased. Time from VTE onset to heparin start, duration of overlapping heparin and warfarin, and inferior vena cava (IVC) filter placement were not independent predictors of recurrence. At a heparin dose ≥ 30 000 U/d, the median proportion of time with an APTT ≥ 0.2 anti-Xa U/mL was 92%, suggesting that routine APTT monitoring and heparin dose adjustment may be unnecessary. In summary, lower-intensity heparin and standard-intensity warfarin anticoagulation are effective in preventing VTE recurrence.
P3‐006: Neurons during early development are highly vulnerable to TDP‐43 dysregulation
Yang, Baoli, Farnham, Mackenzie, Wuertzer, Charles A., D’Alton, Simon , Howard, John , Lin, Wen-Lang, Scott, Brittany, Jurasic, Michael, Yu, Xin , Bailey, Rachel M. , Petrucelli, Leonard , Lewis, Jada , Cannon, Ashley , Knight, Joshua A. , Zhang, Yong‐Jie , Dickson, Dennis W.

Alzheimer's & Dementia | August 1, 2011 | Volume: 7 | Issue: 4S_Part_15 | Pages: No page available

10.1016/j.jalz.2011.05.1445 Get It

P3‐003: Effect of strain background on pathology progression in tau mouse model
Bailey, Rachel M. , Howard, John , Lewis, Jada , Knight, Joshua A. , Dickson, Dennis W.

Alzheimer's & Dementia | August 1, 2011 | Volume: 7 | Issue: 4S_Part_15 | Pages: No page available

10.1016/j.jalz.2011.05.1442 Get It

Frailty Across the Spectrum of Ankle-Brachial Index
Singh, Siddharth , Bailey, Kent R. , Noheria, Amit , Kullo, Iftikhar J.

Angiology | July 6, 2011 | Volume: 63 | Issue: 3 | Pages: 229-236

10.1177/0003319711413457 | PMID 21733950 Get It

We investigated the burden of frailty across the spectrum of ankle-brachial index (ABI < 0.9, 0.9 ≤ ABI < 1.1, 1.1 ≤ ABI < 1.4 and ≥1.4) using data from the National Health and Nutritional Examination Survey (NHANES) in respondents aged >50 years. Criteria used to identify frailty status included weight loss, slow walking speed, weakness, exhaustion, and low physical activity. Participants meeting 1 to 2 criteria were classified as prefrail, and those meeting ≥3 criteria were classified as frail. Prevalence of frailty in respondents with ABI < 0.9 (17.5%) and 0.9 ≤ ABI < 1.1 (6.7%) was higher than in participants with normal ABI-1.1 ≤ ABI < 1.4 (4.7%). In multivariable multinomial logistic regression models, ABI < 0.9 predicted frailty (odds ratio [OR] = 2.31, 95% confidence interval [CI] = 1.08-4.94) and prefrailty (OR = 1.36, 95% CI = 0.90-2.07). Higher prevalence of frailty was seen in participants with ABI ≥ 1.4 (7.3%), P = .39. Frailty predicted general and cardiovascular mortality in participants with ABI < 0.9. Frailty mediates increased morbidity and mortality seen in peripheral arterial disease (PAD).
Improving the predictive ability of the signal-averaged electrocardiogram with a linear logistic model incorporating clinical variables.
Vatterott, Pierce J. , Bailey, Kent R. , Hammill, Stephen C.

Circulation | June 17, 2011 | Volume: 81 | Issue: 3 | Pages: 797-804

10.1161/01.cir.81.3.797 | PMID 2306832 Get It

To improve the predictive accuracy of the signal-averaged electrocardiogram, we created a linear logistic model for predicting ventricular tachycardia during electrophysiologic testing. This signal-averaged electrocardiographic model was created from data obtained from 214 patients undergoing electrophysiologic testing (70 had ventricular tachycardia during electrophysiologic testing) by using stepwise logistic regression to rank eight clinical and nine signal-averaged electrocardiographic variables. The best predictors were ejection fraction, history of infarction, ventricular ectopic pairs or nonsustained ventricular tachycardia on Holter monitoring, QRS duration after 25-Hz filtering, and root mean square voltage of the terminal 40 msec of the QRS complex after 40- and 80-Hz filtering. Cross validation (a statistical technique that can be used to accurately evaluate how a predictive model will perform on a prospective patient population) was used to validate the model. After cross validation, the model's sensitivity was 91% and specificity was 59% for predicting ventricular tachycardia during electrophysiologic testing. This model compared favorably with established 25-Hz late-potential criteria (QRS duration of more than 110 msec and root mean square voltage of less than 25 microV of the terminal 40 msec of the QRS complex; sensitivity, 64%; specificity, 85%) and with established 40-Hz late-potential criteria (QRS duration of more than 114 msec or root mean square voltage of less than 20 microV of the terminal 40 msec of the QRS complex or duration of the low-amplitude signal less than 40 microV at the terminal QRS complex that is greater than 38 msec; sensitivity, 84%; specificity, 54%).(ABSTRACT TRUNCATED AT 250 WORDS)
Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.
Burstow, D. , Bailey, Kent R. , Reeder, Guy S., Holmes, David R. , Seward, J B, Tajik, A. Jamil , Nishimura, Rick A.

Circulation | June 17, 2011 | Volume: 80 | Issue: 3 | Pages: 504-514

10.1161/01.cir.80.3.504 | PMID 2766505 Get It

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtained using a dual-catheter technique. The simultaneous pressure tracings and Doppler flow velocity profiles were digitized at 10-msec intervals to derive the corresponding maximal and mean gradients. The correlation between the maximal Doppler gradient and the simultaneously measured maximal catheter gradient was 0.94 (SEE = 6), and that between the Doppler gradient and the simultaneously measured mean catheter gradient was 0.96 (SEE = 3). There were no significant differences in correlation between gradients for the 32 mechanical valves (maximal gradients: r = 0.95, SEE = 6; mean gradients: r = 0.96, SEE = 3) and the 10 bioprosthetic valves (maximal gradients: r = 0.89, SEE = 6; mean gradients: r = 0.93, SEE = 3). In patients with mitral prostheses, Doppler gradients correlated well with the corresponding catheter gradients obtained with direct measurement of left atrial pressure (maximal gradients: r = 0.96, SEE = 2; mean gradients: r = 0.97, SEE = 1.2). A close correlation between corresponding Doppler and catheter gradients also was found in patients with aortic prostheses (maximal gradients: r = 0.94, SEE = 6; mean gradients: r = 0.94, SEE = 3). Thus, continuous wave Doppler echocardiography can accurately predict the pressure gradient across prosthetic valves.
Effects of thrombin inhibition on the development of acute platelet-thrombus deposition during angioplasty in pigs. Heparin versus recombinant hirudin, a specific thrombin inhibitor.
Chesebro, James H., Penny, W J, Bailey, Kent R. , Badimón, Lina , Heras, Misericordia Veciana de las , Fuster, Valentı́n

Circulation | June 17, 2011 | Volume: 79 | Issue: 3 | Pages: 657-665

10.1161/01.cir.79.3.657 | PMID 2521818 Get It

The effect of recombinant hirudin and the dosage of heparin on acute platelet-thrombus deposition during carotid angioplasty in anesthetized pigs was prospectively assessed. Fifty-five animals (mean weight, 33.9 kg) were randomized to one of six heparin dosages: heparin boluses of 35, 50, 100, 150, 200, or 250 units/kg followed by a continuous infusion of 35, 50, 100, 150, 200, or 250 units/kg/hr, respectively. Another five pigs received a bolus of 1 mg/kg hirudin (recombinant desulphatohirudin), a specific thrombin inhibitor, followed by an infusion of 1 mg/kg/hr. Bilateral carotid angioplasty was performed in all pigs 20 minutes after starting the infusion; they were sacrificed 57 +/- 12 minutes after the procedure. Deep medial arterial injury was present in approximately 75% of the dilated segments, and subendothelial injury in the remaining 25%. Mean log of number of platelets and molecules of fibrinogen per centimeter squared of deep injury in segments from all the animals treated with heparin were 4.74 +/- 1.03 and 5.02 +/- 0.64, respectively. A regression analysis showed an inverse correlation of the log of platelet deposition with the heparin group (r = -0.56, p = 0.0001) with administered total units of heparin (r = -0.55, p = 0.0003) and with mean plasma heparin concentration (r = -0.55, p = 0.0004) in deeply injured arteries. Similar inverse relations were obtained for fibrinogen. In contrast, the deposition of platelets and fibrinogen in subendothelial injury was very low and independent of the heparin administered.(ABSTRACT TRUNCATED AT 250 WORDS)
Importance of adequate heparin dosage in arterial angioplasty in a porcine model.
Chesebro, James H., Penny, W J, Bailey, Kent R. , Lam, Jules Y.T., Holmes, David R. , Reeder, Guy S., Badimón, Lina , Heras, Misericordia Veciana de las , Fuster, Valentı́n

Circulation | June 17, 2011 | Volume: 78 | Issue: 3 | Pages: 654-660

10.1161/01.cir.78.3.654 | PMID 2970341 Get It

Acute occlusion after a successful angioplasty is a severe complication that has been reported in 2-12% of patients. Therefore, to determine whether there was a relation between the dosage of heparin and the presence of mural thrombosis, we studied in a pig model the relation between the dosage of heparin and acute platelet-thrombus deposition on the site of arterial injury. We retrospectively analyzed the effect of three heparin regimens on platelet deposition in 32 normal pigs (mean weight, 32.7 kg) that underwent bilateral carotid angioplasty and were sacrificed 90 +/- 26 minutes later. Pigs in protocol 1 (n = 7) received an intravenous bolus injection of 4,000 units heparin 10 minutes before angioplasty. Pigs in protocol 2 (n = 11) received two bolus injections of 4,000 units heparin 40 minutes apart; the angioplasty was performed immediately after the second bolus. Pigs in protocol 3 (n = 14) had an initial 4,000-unit bolus injection of heparin followed immediately by an infusion of 4,000 units/hr; angioplasty was performed 20 minutes after starting the infusion. 111In-labeled platelet deposition on deeply injured (torn into the media) arterial segments were 86.3 +/- 68, 56.2 +/- 56.9, and 37.7 +/- 37.7 X 10(6)/cm2 for protocols 1, 2, and 3, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
The Role of Lipoprotein A-I and Lipoprotein A-I/A-II in Predicting Coronary Artery Disease
Nguyen, T. T. , Hallaway, Brenda J., Hodge, David O. , Bailey, Kent R. , Holmes, David R. , Kottke, B A, O’Brien, Timothy

Arteriosclerosis, Thrombosis, and Vascular Biology | June 17, 2011 | Volume: 15 | Issue: 2 | Pages: 228-231

10.1161/01.atv.15.2.228 | PMID 7749830 Get It

Abstract The aim of this study was to examine the role of HDL subparticles with apolipoprotein (apo) A-I alone (LpA-I) and with apoA-I and apoA-II (LpA-I/A-II) in predicting coronary artery disease. Concentrations of these HDL subparticles were compared in 184 subjects with angiographically confirmed significant coronary artery disease (>50% stenosis of at least one vessel) and 191 age- and sex-matched control subjects without clinical coronary artery disease. LpA-I and LpA-I/A-II were measured with magnetic beads coated with anti–apoA-II antibodies to separate particles containing apoA-II from plasma. Total plasma cholesterol and triglyceride levels were similar in both groups. Although subjects with coronary artery disease had lower HDL cholesterol, plasma apoA-I, LpA-I, and LpA-I/A-II than age- and sex-matched control subjects without coronary artery disease, plasma apoA-I was the best predictor of coronary artery disease. In conclusion, LpA-I and LpA-I/A-II are lower in subjects with coronary artery disease but do not add to plasma apoA-I in predicting the presence of coronary artery disease.