BACKGROUND Normal Doppler hemodynamics for tricuspid prostheses have not been well characterized in a large group of patients. Therefore, we analyzed comprehensive Doppler echocardiographic examinations of 82 patients with tricuspid prostheses that were normal by clinical and two-dimensional echocardiographic examinations to establish the normal hemodynamics of various types and sizes of tricuspid prostheses. METHODS AND RESULTS The earliest complete postoperative echocardiographic study from each patient was chosen for analysis. Doppler examinations were analyzed on an off-line station from tapes or Doppler strip charts. Early velocity, atrial velocity, end-diastolic velocity, pressure half-time, and mean gradient were obtained by digitizing tricuspid velocity curves. The incidence of "physiological" tricuspid prosthetic regurgitation was noted. Ten Doppler cycles were measured for each patient, and maximal, minimal, and average measurements were recorded. The mean values +/- SD of early velocity, atrial velocity, end-diastolic velocity, mean gradient, and pressure half-time and incidence of mild prosthetic regurgitation were reported for each type of prosthesis, as were highest Doppler measurements for each valve type. Average pressure half-time was significantly lower for St Jude than for heterograft prostheses (P = .04). There were no significant differences between the valve types for mean gradient, early velocity, or incidence of prosthetic regurgitation. Increasing prosthesis size was associated with lower average pressure half-time for heterograft prostheses (P = .024). Average differences (respiratory- and cycle-length-dependent) between maximal and minimal values for 10 cardiac cycles were established for each prosthesis. CONCLUSIONS This study establishes normal ranges for Doppler hemodynamics of various tricuspid prostheses and emphasizes the importance of measuring multiple cycles for each tricuspid prosthesis, regardless of cardiac rhythm.
Carcinoid heart disease. Clinical and echocardiographic spectrum in 74 patients.
BACKGROUND The carcinoid syndrome is a rare cause of acquired valvular heart disease. Although the typical echocardiographic features of carcinoid heart disease are well recognized, this large series provides new information about unusual manifestations of the disease as well as the role of Doppler echocardiography. METHODS AND RESULTS Between 1980 and 1989, 132 patients with carcinoid syndrome underwent echocardiographic study. The echocardiographic, Doppler, and clinical features of the 74 patients (56%) with echocardiographic evidence of carcinoid heart disease are described. Among these patients, 97% had shortened, thickened tricuspid leaflets. Tricuspid regurgitation was present in all 69 patients with carcinoid heart disease who underwent Doppler examination, and it was of moderate or severe degree in 62 patients (90%). Severe tricuspid regurgitation was characterized by a dagger-shaped Doppler spectral profile with an early peak pressure and rapid decline. The pressure half-time was prolonged (mean, 116 msec), which is consistent with associated tricuspid stenosis. The pulmonary valve appeared thickened, retracted, and immobile in 36 patients (49%) and was diminutive to the extent of not being visualized in an additional 29 patients (39%). Among the 47 patients who underwent Doppler evaluation of the pulmonary valve, regurgitation was present in 81%, and stenosis was present in 53%. Left-sided valvular involvement was present in five patients (7%), four of whom had patent foramen ovale or carcinoid tumor involving the lung. Previously undescribed myocardial metastases were present in three patients (4%) and were confirmed by biopsy in each case. Small pericardial effusions were present in 10 patients (14%). Patients with and without echocardiographic evidence of carcinoid heart disease did not differ with regard to sex, age, location of the primary tumor, duration of diagnosis, or duration of symptoms of carcinoid syndrome. However, the mean pretreatment level of urinary 5-hydroxyindoleacetic acid was higher in patients with carcinoid heart disease than in patients without carcinoid heart disease (270 versus 131 mg/24 hrs, p < 0.001). The symptom of dyspnea was more prevalent among patients with carcinoid heart disease than in patients without the disease (54% versus 27%, p = 0.003); as expected, heart murmurs were also noted more frequently in patients with disease (92% versus 43%, p < 0.0001). Treatment regimens and response to therapy were similar in the two groups. Survival of patients with echocardiographic evidence of carcinoid heart disease was reduced compared with those without cardiac involvement (p = 0.0003). ECG and chest roentgenographic findings in patients with carcinoid heart disease were nonspecific. CONCLUSIONS The broad spectrum of carcinoid heart disease is detailed in this large series. This includes not only right-sided valvular lesions but also left-sided involvement, pericardial effusion, and myocardial metastases.
Prospective evaluation of the risk of bacteremia associated with transesophageal echocardiography.
BACKGROUND Transient bacteremia may lead to endocarditis in patients with significant valvular lesions. METHODS AND RESULTS Because transesophageal echocardiography selects a patient population with a high prevalence of valvular lesions, we prospectively evaluated the risk of transient bacteremia associated with transesophageal echocardiography in 49 patients. Blood cultures were obtained immediately before transesophageal echocardiography and at 5, 10, and 20 minutes after the start of the procedure. For each culture, 30 ml venous blood was obtained and 10 ml was inoculated into each of an Isolator tube, Septi-chek bottle, and a nonvented Trypticase soy broth bottle. Broth cultures were incubated for 14 days. Blood from the Isolator tube was plated onto appropriate media for recovery of bacteria and fungi. Two patients were excluded from analysis because the final two sets of blood cultures could not be obtained. Among the remaining 47 study patients, two preprocedure control blood cultures were positive, and two of 141 subsequent cultures were positive. All isolates were considered contaminants. Thus, we found no significant bacteremia due to pathogenic oral flora during transesophageal echocardiography (0%; 95% CI, 0.0-7.5%). CONCLUSIONS Although recommendations for antimicrobial prophylaxis for transesophageal echocardiography should be individualized for each patient, many patients may not require antimicrobial prophylaxis.
Value and limitations of transesophageal echocardiography in assessment of mitral valve prostheses.
BACKGROUND Transthoracic Doppler echocardiography examination has become an integral part of the investigations performed in patients with mitral valve prostheses. The limitations of the transthoracic approach are well documented. Transesophageal echocardiography provides a unique window for achieving a clear view of the mitral prosthesis. METHODS AND RESULTS This study shows the usefulness of transesophageal echocardiography in clinical practice for assessment of patients with a mitral valve prosthesis. This technique demonstrated an abnormality in 48% of patients who had normal results on transthoracic examination. The overall sensitivity of transesophageal echocardiography was 96%. CONCLUSIONS Transesophageal echocardiography constitutes an essential part of a comprehensive two-dimensional/Doppler echocardiographic examination in patients with suspected malfunction of mitral prostheses.
Prognostic significance of Doppler measures of diastolic function in cardiac amyloidosis. A Doppler echocardiography study.
BACKGROUND We have previously characterized the left ventricular diastolic filling abnormalities in cardiac amyloidosis by Doppler methods. The various filling patterns were shown to be related to the degree of cardiac amyloid infiltration. The purpose of this study was to determine the value of Doppler diastolic filling variables for assessing prognosis in cardiac amyloidosis. METHODS AND RESULTS We performed pulsed-wave Doppler studies of the left ventricular inflow and obtained clinical follow-up data in 63 consecutive patients with biopsy-proven systemic amyloidosis. All patients had typical echocardiographic features of cardiac involvement. The patients were subdivided into two groups according to deceleration time: Group 1 (33 patients) had a deceleration time of 150 msec or less, indicative of restrictive physiology, and group 2 (30 patients) had a deceleration time of more than 150 msec. Of the 63 patients, 32 (51%) died during a mean follow-up period of 18 +/- 12 months. Of these deaths, 25 (78%) were cardiac deaths, and 19 of the 25 patients (76%) were from group 1. The 1-year probability of survival in group 1 was significantly less than that in group 2 (49% versus 92%, p less than 0.001). Bivariate analysis revealed that the combination of the Doppler variables of shortened deceleration time and increased early diastolic filling velocity to atrial filling velocity ratio were stronger predictors of cardiac death than were the two-dimensional echocardiographic variables of mean left ventricular wall thickness and fractional shortening. CONCLUSIONS Doppler-derived left ventricular diastolic filling variables are important predictors of survival in cardiac amyloidosis.
Quantitative Doppler assessment of valvular regurgitation.
BACKGROUND Quantitation of valvular regurgitation remains a challenge. The accuracy of quantitative Doppler is controversial, and its ability to measure regurgitant volume is unknown; therefore, it is not widely used. METHODS AND RESULTS In 120 patients (20 without regurgitation, 19 with aortic regurgitation, and 81 with mitral regurgitation), the stroke volume through the mitral annulus and left ventricular outflow tract were measured using pulsed-wave Doppler concurrently with left ventricular stroke volume calculated using left ventricular volumes measured by two-dimensional echocardiography Simpson's biapical method. Regurgitant volume and fraction were thus computed using Doppler or ventricular methods. In normal patients there were good correlations between Doppler and left ventricular measurements of stroke volume. Doppler regurgitant volume and fraction were 4.4 +/- 4.4 mL and 5.3 +/- 4.5%, respectively. In patients with aortic regurgitation, there were good correlations between Doppler and left ventricular measurements of stroke volume, regurgitant volume, and regurgitant fraction (r = 0.97, r = 0.95, and r = 0.93, respectively; p < 0.0001). In patients with mitral regurgitation, despite good correlations between Doppler and ventricular methods for stroke volume, regurgitant volume, and regurgitant fraction (r = 0.94, r = 0.93, and r = 0.94, respectively; p < 0.001), these variables were overestimated by Doppler. However, in the last 54 patients compared with the first 27, overestimation decreased significantly for regurgitant volume (5 +/- 10 mL versus 18 +/- 27 mL, p < 0.05) and regurgitant fraction (3.3 +/- 6.7% versus 6.2 +/- 6.8%, p = 0.05). CONCLUSIONS Quantitative Doppler can be performed in large numbers of patients in a clinical laboratory. Its potential limitation was identified as overestimation of mitral regurgitation, which is overcome with increased experience. Its achieved accuracy in mitral and aortic regurgitation allows measurement not only of regurgitant fraction but most importantly of regurgitant volume.
Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtained using a dual-catheter technique. The simultaneous pressure tracings and Doppler flow velocity profiles were digitized at 10-msec intervals to derive the corresponding maximal and mean gradients. The correlation between the maximal Doppler gradient and the simultaneously measured maximal catheter gradient was 0.94 (SEE = 6), and that between the Doppler gradient and the simultaneously measured mean catheter gradient was 0.96 (SEE = 3). There were no significant differences in correlation between gradients for the 32 mechanical valves (maximal gradients: r = 0.95, SEE = 6; mean gradients: r = 0.96, SEE = 3) and the 10 bioprosthetic valves (maximal gradients: r = 0.89, SEE = 6; mean gradients: r = 0.93, SEE = 3). In patients with mitral prostheses, Doppler gradients correlated well with the corresponding catheter gradients obtained with direct measurement of left atrial pressure (maximal gradients: r = 0.96, SEE = 2; mean gradients: r = 0.97, SEE = 1.2). A close correlation between corresponding Doppler and catheter gradients also was found in patients with aortic prostheses (maximal gradients: r = 0.94, SEE = 6; mean gradients: r = 0.94, SEE = 3). Thus, continuous wave Doppler echocardiography can accurately predict the pressure gradient across prosthetic valves.