Citations

Mayo Clinic

Clear

25 citation(s) found for "Murphy, Joseph".

Brief Communication: Outcomes of Subsequent Pregnancy after Peripartum Cardiomyopathy: A Case Series from Haiti
Fett, James D., Christie, Len G., Murphy, Joseph G.

Annals of Internal Medicine | April 12, 2013 | Volume: 145 | Issue: 1 | Pages: 30-34

10.7326/0003-4819-145-1-200607040-00007 | PMID 16818926 Get It

Acute Myocardial Infarction and Renal Dysfunction: A High-Risk Combination
Wright, R. Scott , Reeder, Guy S., Herzog, Charles A. , Albright, Robert C. , Williams, Brent A. , Dvorak, David L., Murphy, Joseph G. , Kopecky, Stephen L. , Jaffe, Allan S. , Miller, Wayne L. , Jaffe, Allan S.

Annals of Internal Medicine | April 12, 2013 | Volume: 137 | Issue: 7 | Pages: 563-570

10.7326/0003-4819-137-7-200210010-00007 | PMID 12353943 Get It

Percutaneous polymeric stents in porcine coronary arteries. Initial experience with polyethylene terephthalate stents.
Murphy, Joseph G. , Schwartz, Robert S., Edwards, William D. , Camrud, Allan R., Vlietstra, R E, Holmes, David R.

Circulation | June 12, 2012 | Volume: 86 | Issue: 5 | Pages: 1596-1604

10.1161/01.cir.86.5.1596 | PMID 1423971 Get It

BACKGROUND To test the feasibility of percutaneous deployment of intracoronary polymeric stents, a prototype polyethylene terephthalate (PET) stent and a catheter-based delivery system were developed. METHODS AND RESULTS Polymeric stents were deployed in the coronary arteries of 11 Yucatan swine: six stents were placed in the left anterior descending coronary artery, four stents were placed in the circumflex artery, and one stent was placed in the right coronary artery. Stent deployment was achieved by withdrawal of an outer delivery sheath, thus allowing the PET stent to self-expand to a preformed configuration. Two animals died during surgery, one during stent placement and the other several hours after implantation due to intracoronary thrombus formation. Two animals were electively sacrificed within 24 hours of stent implant to examine the adequacy of stent deployment within the coronary vessel. The remaining seven animals survived until the termination of the study 4-6 weeks later. Light microscopic examination of the stented vessels showed an extensive neointimal proliferative response with vessel occlusion in all animals who survived initial stent placement. There were two distinct types of histological responses to the PET stent--a chronic foreign body inflammatory response around the stent tines and a neointimal proliferative response in the center of the occluded vessel lumen. The histological response seen in the central area of the vessel was morphologically similar to that seen in patients with restenosis after successful percutaneous transluminal coronary angioplasty, whereas the morphological response seen at the periphery of the stent tine was similar to that exhibited by a chronic foreign body reaction and was not typical of that seen in a restenosis lesion. A ventricular aneurysm also developed in the area of myocardium that was previously supplied by the occluded vessel. CONCLUSIONS This study demonstrates that percutaneous deployment of polymeric stents in the coronary arteries is technically feasible. The use of PET polymer was associated with an intense proliferative neointimal response that resulted in complete vessel occlusion. Histological examination of the stented segments of the vessel revealed no evidence that dissection of the vessel wall had occurred at the time of initial stent deployment. Although the PET polymer was of similar quality to that used in the manufacture of balloon angioplasty catheters, a toxic chemical or contaminant effect cannot be completely excluded as the stimulus to intimal proliferation. This finding may have relevance to the selection of materials for use as intravascular devices.
Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries.
Schwartz, Robert S., Murphy, Joseph G. , Edwards, William D. , Camrud, Allan R., Vliestra, Ronald E., Holmes, David R.

Circulation | June 17, 2011 | Volume: 82 | Issue: 6 | Pages: 2190-2200

10.1161/01.cir.82.6.2190 | PMID 2146991 Get It

A model of proliferative human restenosis was developed in domestic pigs by using deep injury to the coronary arterial media. Metal wire coils were delivered percutaneously to the coronary arteries of 11 pigs with an oversized, high-pressure (14 atm) balloon and were left in place for times ranging from 28 to 70 days. During placement, the balloon expanded the coils and delivered them securely within the arterial lumen. Light microscopic examination of the vessels confirmed fracture of the internal elastic lamina by the coil. An extensive proliferative response occurred in 10 of the 11 pigs and was associated with a luminal area narrowing of at least 50% in all but one pig. The histopathologic features of the proliferative response were identical to those observed in human cases of restenosis after angioplasty. Immunohistochemical studies confirmed the prominence of smooth muscle cells in the proliferative tissue. A similar response was obtained in two of five porcine coronary arteries in which balloon inflation only was performed, without coil implant. This model is practical and inexpensive and closely mimics the proliferative portion of human restenosis both grossly and microscopically. Thus, it may be useful for understanding human restenosis and for testing therapies aimed at preventing restenosis after balloon angioplasty or other coronary interventional procedures.
High Concentrations of Active Plasminogen Activator Inhibitor-1 in Porcine Coronary Artery Thrombi
Fay, William P. , Murphy, Joseph G. , Owen, Whyte G.

Arteriosclerosis, Thrombosis, and Vascular Biology | June 17, 2011 | Volume: 16 | Issue: 10 | Pages: 1277-1284

10.1161/01.atv.16.10.1277 | PMID 8857925 Get It

Addition of exogenous plasminogen activator inhibitor-1 (PAI-1) to fibrin clots inhibits fibrinolysis in vivo. However, it is unknown whether the localized concentrations of active PAI-1 necessary to produce this antifibrinolytic effect can be recruited to acute arterial thrombi by endogenous mechanisms. We measured PAI-1 activity and antigen in porcine coronary artery thrombi that formed in response to acute vascular injury. Mean PAI-1 activity in thrombi (n=5) was 36±5.1 μg/mL, which is >2000 times its concentration in normal porcine plasma. The presence of markedly elevated concentrations of active PAI-1 in thrombi was confirmed by an immunoactivity assay and by demonstrating formation of sodium dodecyl sulfate–stable complexes after addition of 125 I-urokinase to thrombus extracts. Comparative analysis of PAI-1 antigen by Western blotting and urokinase inhibition assay suggested that approximately one third of thrombus-associated PAI-1 was active. Histological examination of coronary thrombi revealed that they consisted predominantly of dense aggregates of platelets with interspersed islands of fibrin, which closely resemble the histological appearance of thrombi in patients with myocardial infarction and unstable angina pectoris. Washed porcine platelets prepared from peripheral blood contained sufficient PAI-1 antigen and activity to account for the concentrations observed in coronary artery thrombi. However, the specific activity of human platelet PAI-1 was lower than that of porcine platelet PAI-1 (2% versus 50% active, respectively), and human platelets inhibited in vitro fibrinolysis to a lesser extent than did porcine platelets. These results indicate that active PAI-1 accumulates in porcine coronary artery thrombi in concentrations markedly higher than those present in plasma and that PAI-1 may be an important determinant of the known resistance of platelet-rich thrombi to lysis by tissue-type plasminogen activator. These studies also underscore the importance of considering possible species differences in protein function when comparing animal models of thrombosis to acute coronary thrombosis in humans.