Back to Authors

Camrud, Allan R.

Mayo Clinic

Mayo Clinic

Citations 6

Selective ET A Receptor Antagonism Reduces Neointimal Hyperplasia in a Porcine Coronary Stent Model
McKenna, Charles J., Burke, Sandra E., Opgenorth, Terry J., Padley, Robert J., Camrud, Ladonna J., Camrud, Allan R., Carlson, Paula J., Holmes, David R. , Schwartz, Robert S., Johnson, Jodi L. , Lerman, Amir

Circulation | June 12, 2012 | Volume: 97 | Issue: 25 | Pages: 2551-2556

10.1161/01.cir.97.25.2551 Get It

Background —As endothelin binds to ET A receptors, it stimulates vascular smooth muscle cell proliferation and may thus be pivotally involved in the pathogenesis of restenosis. This study assessed the ability of a potent and selective ET A antagonist to reduce neointimal hyperplasia in a porcine coronary artery stented injury model. Methods and Results —Fifty-five pigs were randomized to receive placebo or the oral ET A -selective antagonist ABT147627 twice daily for 28 days in one of three doses: 0.75 mg/kg (low), 3.75 mg/kg (mid), and 10.0 mg/kg (high). Each underwent oversized stent deployment in two randomly assigned major epicardial coronary arteries. Three animals (5.5%) died as a consequence of stent thrombosis within 24 hours of the procedure. The remaining 52 animals (13 pigs per group) survived without complication until predetermined euthanasia at 28 days. In the placebo group, mean injury score was 1.73±0.80, with a mean neointimal response of 0.45±0.24 mm. By comparison, the low-dose group had a similar mean injury score of 1.79±0.75 with reduced neointimal response, 0.36±0.22 mm ( P <0.01). Mean injury score in the mid-dose animals was significantly greater than in the placebo group (1.94±0.92; P <0.05). The neointimal hyperplasia associated with this injury was less than with placebo, although the difference did not reach statistical significance (0.40±0.25 mm; P =0.05). In the high-dose pigs, mean injury score was also significantly greater than in the placebo arm (1.93±0.73; P <0.05). Despite this, neointimal response was also significantly less (0.37±0.37 mm; P <0.01). Conclusions —Oral, selective ET A receptor antagonism significantly reduced neointimal hyperplasia forming over porcine coronary stented injuries in the first 28 days. This strategy may have clinical potential for the limitation and treatment of coronary restenosis after percutaneous revascularization.
Neointimal Thickening After Severe Coronary Artery Injury Is Limited by Short-term Administration of a Factor Xa Inhibitor
Schwartz, Robert S., Holmes, David R. , Veinot, John P. , Camrud, Allan R., Jorgenson, Michael A., Johnson, Robert G. , Holder, Daniel

Circulation | June 12, 2012 | Volume: 93 | Issue: 8 | Pages: 1542-1548

10.1161/01.cir.93.8.1542 Get It

Background Fibrin- and platelet-rich thrombus formations occur as the initial event after percutaneous transluminal coronary angioplasty. We therefore tested the hypothesis that short-term administration of the recombinant tick anticoagulant peptide (rTAP), a factor Xa inhibitor, would reduce the thickness of neointima at 28 days after injury in a porcine coronary balloon angioplasty model. Methods and Results Continuous intravenous infusion of rTAP (average dose, 194 μg·kg −1 ·min −1 ) or placebo (vehicle only) was given to the study pigs for 60 hours. The goal of anticoagulation was to maintain the activated clotting time at 200 seconds. A central venous catheter was inserted 2 days before the procedure. On the day of coronary injury, the animals were administered boluses of rTAP (6.5 mg) and then underwent injury with an oversized metallic coil by standard methods in the right, circumflex, or left anterior descending coronary artery. No significant difference in vascular injury between rTAP and vehicle control was observed after euthanasia at 28 days. Significantly less neointimal thickening occurred in the rTAP-treated animals (thickness, mean±SD: 0.30±0.08 mm) compared with the control (0.48±0.12 mm, P <.001). Conclusions The specific factor Xa inhibitor rTAP, when given in fully anticoagulant doses for a short duration after coronary artery injury in the porcine model, resulted in a long-term decrease in neointimal thickness. These results implicate thrombin generation in neointimal formation and suggest that administration of a potent antithrombotic for several days immediately after the procedure may influence the long-term outcome of the coronary injury with a decrease in neointimal formation.
Percutaneous polymeric stents in porcine coronary arteries. Initial experience with polyethylene terephthalate stents.
Murphy, Joseph G. , Schwartz, Robert S., Edwards, William D. , Camrud, Allan R., Vlietstra, R E, Holmes, David R.

Circulation | June 12, 2012 | Volume: 86 | Issue: 5 | Pages: 1596-1604

10.1161/01.cir.86.5.1596 Get It

BACKGROUND To test the feasibility of percutaneous deployment of intracoronary polymeric stents, a prototype polyethylene terephthalate (PET) stent and a catheter-based delivery system were developed. METHODS AND RESULTS Polymeric stents were deployed in the coronary arteries of 11 Yucatan swine: six stents were placed in the left anterior descending coronary artery, four stents were placed in the circumflex artery, and one stent was placed in the right coronary artery. Stent deployment was achieved by withdrawal of an outer delivery sheath, thus allowing the PET stent to self-expand to a preformed configuration. Two animals died during surgery, one during stent placement and the other several hours after implantation due to intracoronary thrombus formation. Two animals were electively sacrificed within 24 hours of stent implant to examine the adequacy of stent deployment within the coronary vessel. The remaining seven animals survived until the termination of the study 4-6 weeks later. Light microscopic examination of the stented vessels showed an extensive neointimal proliferative response with vessel occlusion in all animals who survived initial stent placement. There were two distinct types of histological responses to the PET stent--a chronic foreign body inflammatory response around the stent tines and a neointimal proliferative response in the center of the occluded vessel lumen. The histological response seen in the central area of the vessel was morphologically similar to that seen in patients with restenosis after successful percutaneous transluminal coronary angioplasty, whereas the morphological response seen at the periphery of the stent tine was similar to that exhibited by a chronic foreign body reaction and was not typical of that seen in a restenosis lesion. A ventricular aneurysm also developed in the area of myocardium that was previously supplied by the occluded vessel. CONCLUSIONS This study demonstrates that percutaneous deployment of polymeric stents in the coronary arteries is technically feasible. The use of PET polymer was associated with an intense proliferative neointimal response that resulted in complete vessel occlusion. Histological examination of the stented segments of the vessel revealed no evidence that dissection of the vessel wall had occurred at the time of initial stent deployment. Although the PET polymer was of similar quality to that used in the manufacture of balloon angioplasty catheters, a toxic chemical or contaminant effect cannot be completely excluded as the stimulus to intimal proliferation. This finding may have relevance to the selection of materials for use as intravascular devices.
Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries.
Schwartz, Robert S., Murphy, Joseph G. , Edwards, William D. , Camrud, Allan R., Vliestra, Ronald E., Holmes, David R.

Circulation | June 17, 2011 | Volume: 82 | Issue: 6 | Pages: 2190-2200

10.1161/01.cir.82.6.2190 Get It

A model of proliferative human restenosis was developed in domestic pigs by using deep injury to the coronary arterial media. Metal wire coils were delivered percutaneously to the coronary arteries of 11 pigs with an oversized, high-pressure (14 atm) balloon and were left in place for times ranging from 28 to 70 days. During placement, the balloon expanded the coils and delivered them securely within the arterial lumen. Light microscopic examination of the vessels confirmed fracture of the internal elastic lamina by the coil. An extensive proliferative response occurred in 10 of the 11 pigs and was associated with a luminal area narrowing of at least 50% in all but one pig. The histopathologic features of the proliferative response were identical to those observed in human cases of restenosis after angioplasty. Immunohistochemical studies confirmed the prominence of smooth muscle cells in the proliferative tissue. A similar response was obtained in two of five porcine coronary arteries in which balloon inflation only was performed, without coil implant. This model is practical and inexpensive and closely mimics the proliferative portion of human restenosis both grossly and microscopically. Thus, it may be useful for understanding human restenosis and for testing therapies aimed at preventing restenosis after balloon angioplasty or other coronary interventional procedures.
Differential neointimal response to coronary artery injury in pigs and dogs. Implications for restenosis models.
Schwartz, R S, Edwards, William D. , Bailey, Kent R. , Camrud, Allan R., Jorgenson, Mica, Holmes, D R

Arteriosclerosis and Thrombosis: A Journal of Vascular Biology | June 17, 2011 | Volume: 14 | Issue: 3 | Pages: 395-400

10.1161/01.atv.14.3.395 Get It

Neointimal hyperplasia occurs in the coronary arteries after percutaneous revascularization procedures and is a reparative response that frequently causes recurrent stenosis. Prior animal studies have shown that neointimal tissue thickness is proportional to the depth of arterial injury. Because animal models are increasingly used to test therapeutic strategies against restenosis, the purpose of this study was to evaluate the degree of neointimal thickening formed in the coronary arteries of pigs compared with dogs in response to severe injury. Fourteen coronary arteries in six mongrel dogs and 18 coronary arteries in nine pigs underwent severe arterial injury using tantalum metal coils delivered on oversized angioplasty balloons. Animals were killed after 4 weeks, and all coronary arteries were pressure perfusion fixed. Mean histological injury scores and neointimal thicknesses for dogs were 1.9 +/- 0.3 and 0.30 +/- 0.11, respectively, compared with 2.1 +/- 0.7 and 0.71 +/- 0.36 for pigs. Thus, there was significantly less neointimal thickening in dogs compared with pigs (P < .001) despite no differences in injury (P = NS). The neointimal thickening differences translated into significantly different percent area stenoses: 55 +/- 24% for pigs versus 27 +/- 13% for dogs (P < .001). Linear regression modeled neointimal thickness versus injury assessed by an ordinal injury score proportional to the depth of injury for each species. This analysis confirmed the differences across multiple injury levels. The slope of the regression line for dogs was small, suggesting that no relation may exist between injury and neointimal thickness in this species. The pig may be a more appropriate model for the study of the genesis of stenosing neointima.(ABSTRACT TRUNCATED AT 250 WORDS)
p27-p16 Fusion Gene Inhibits Angioplasty-Induced Neointimal Hyperplasia and Coronary Artery Occlusion
Tsui, Lisa, Camrud, Allan R., Mondesire, Jean, Carlson, Paula, Zayek, Nathalie, Camrud, Ladonna J., Donahue, Brian A., Lin, Andy, Frey, David , Rivkin, Marianne, Subramanian, Ajit, Falotico, Robert, Gyuris, Jenő, Schwartz, Robert S., McArthur, James G., Bauer, Scott R.

Circulation Research | September 28, 2007 | Volume: 89 | Issue: 4 | Pages: 323-328

10.1161/hh1601.094482 Get It

Inhibition of proliferative neointima formed by vascular smooth muscle cells is a potential target in preventing angioplasty-induced restenosis. We have created a potent antiproliferative by fusing the active regions of the p27 and p16 cell cycle inhibitors. Intravascular delivery of a replication-deficient adenoviral vector (AV) encoding this p27-p16 fusion protein, named W9, inhibited balloon injury–induced neointimal hyperplasia in rabbit carotid arteries. In a therapeutically more relevant model, AV-W9 was delivered to balloon-injured porcine coronary arteries in vivo using an infusion catheter. Of the three coronary arteries, two were injured with a 15-mm balloon catheter and either were left untreated or were treated with 10 12 viral particles of either AV-W9 or a control null virus. AV-W9 treatment significantly inhibited neointimal hyperplasia in this porcine arterial balloon injury model compared with untreated or control virus–treated vessels. The average intimal area of the AV-W9–treated group 10 days after balloon injury and treatment was 0.42±0.36 mm 2 , whereas the AV-null group demonstrated an intimal area of 0.70±0.52 mm 2 . At day 10 the average intimal thickness of the AV-W9–treated vessels was 9.1 μm (n=5, ×20 magnification) compared with 21.2 μm (n=5, ×20 magnification) in control virus–treated vessels. This trend was also observed at 28 days after balloon injury and gene transfer during which AV-W9–treated vessels demonstrated an average intimal thickness of 4.7 μm (n=8, ×20 magnification) compared with 13.3 μm (n=3, ×20 magnification) in control virus–treated vessels and 7.3 μm (n=5, ×20 magnification) in the sham-treated vessels. The AV-W9 treatment was safe and well tolerated. These data suggest that AV-W9 gene therapy may be useful in preventing angioplasty–induced intimal hyperplasia in the coronary artery.