Citations

Mayo Clinic

Showing 10 of 108585 citations.

Patient‐reported quality of life and acceptance of the extravascular implantable cardioverter‐defibrillator: Results from pivotal study
Harrell, Rebecca , Crozier, Ian , Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Birgersdotter‐Green, Ulrika , Wiggenhorn, Christopher, Hilleren, Gregory, Friedman, Paul A. , Sears, Samuel F , Harrell, Rebecca , Crozier, Ian , Boersma, Lucas , Manlucu, Jaimie , Friedman, Paul A , Knight, Bradley P , Sears, Samuel F.

Journal of Cardiovascular Electrophysiology | December 4, 2023 | Volume: 35 | Issue: 2 | Pages: 240-246

10.1111/jce.16151 | PMID 38047465 Get It

Abstract Introduction The pivotal study of the extravascular implantable cardioverter‐defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient‐reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. Methods The EV ICD Pivotal Study was a prospective, single‐arm, nonrandomized, global, premarket approval trial. Patients completed the 12‐Item Short Form Survey (SF‐12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. Results From baseline to 6 months, patients within the EV ICD Pivotal Study ( n = 247) reported statistically significant SF‐12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV‐ICD or S‐ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S‐ICD and 73.0 ± 17.4, p = .004 for TV‐ICD). Conclusion The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6‐month follow‐up and markedly better overall acceptance of their ICD compared to a previous study with S‐ICD and TV‐ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.
Risk Factors for Surgical-site Infections After Liver Transplant: Does Perioperative Antibiotic Regimen Matter?
Rolak, Stacey , Lahr, Brian D. , Razi, Samrah, Watt, Kymberly D. , Yang, Liu , Aqel, Bashar , Rolak, Stacey C, Watt, Kymberly, Yetmar, Zachary A. , Beam, Elena , Aqel, Bashar A. , Mahmood, Maryam , Yang, Liu

Transplantation | December 4, 2023 | Volume: 108 | Issue: 5 | Pages: 1179-1188

10.1097/tp.0000000000004810 | PMID 38044495 Get It

Background. Surgical-site infections (SSIs) are common in liver transplant recipients. The optimal SSI antimicrobial prophylaxis agent and duration are not established. We aimed to explore risk factors for SSIs after transplant, with a particular interest in the impact of perioperative antibiotic regimen on the development of SSIs. Methods. Retrospective study of adults undergoing liver transplant across 3 transplant programs between January 1, 2020, and June 01, 2021. Results. Of 557 patients included in the study, 32 (5.7%) were infected or colonized with a multidrug-resistant organism (MDRO) within 1 y before liver transplant. Narrow-spectrum SSI prophylaxis with ceftriaxone or cefazolin alone was administered in 488 of 577 patients (87.6%); the remaining 69 patients (12.4%) received broad-spectrum prophylaxis with vancomycin and aztreonam (n = 40), piperacillin–tazobactam (n = 11), carbapenems (n = 8), ceftriaxone and another antibiotic (n = 7), and others. Patients with pretransplant MDRO were more likely to receive broad-spectrum coverage than those without pretransplant MDROs (28.1% versus 11.4%, P = 0.005). SSIs were identified in 40 patients (7.2%); 25 (62.5%) were organ–space infections, 3 (7.5%) were deep incisional infections, and 12 (30.0%) were superficial incisional infections. The median time from liver transplant to SSIs was 14 d (interquartile range, 10–20.2). MDROs were identified in 12 SSIs (30%). Multivariable analysis revealed no significant association between antimicrobial spectrum and risk of SSIs (P = 0.5), whereas surgical leak (P<0.001) and reoperation (P = 0.017) were independently associated with increased risk of SSIs. SSIs were not significantly associated with composite risk of death or liver allograft failure. Conclusions. The spectrum of antimicrobial prophylaxis did not impact the development of SSIs in liver transplant recipients.
Minimally Invasive Quadriceps Tendon Harvest for Anterior Cruciate Ligament Reconstruction Using the Quadriceps Tendon Harvest Guide (QUADTRAC) System and Repair Augmentation With a Bioinductive Implant
Wang, Allen S. , Boos, Alexander M. , Dancy, Malik E. , Camp, Christopher L. , Hevesi, Mario , Okoroha, Kelechi R. , Camp, Christopher L. , Wang, Allen , Boos, Alexander , Hevesi, Mario

Arthroscopy Techniques | December 4, 2023 | Volume: 13 | Issue: 1 | Pages: No page available

10.1016/j.eats.2023.08.017 | PMID 38312883 Get It

Abstract Quadriceps tendon autografts are an increasingly popular choice for anterior cruciate ligament (ACL) reconstruction, with decreased donor‐site morbidity alongside good patient outcomes. Although harvesting of the tendon can be done in a minimally invasive fashion, this introduces some difficulty with visualization and consistency of graft sizing. The purpose of this Technical Note and video is to provide a method of quadriceps tendon autograft harvesting using the Quadriceps Tendon Harvest Guide System (QUADTRAC) in a single‐bundle ACL reconstruction. Technique Video video See video under supplementary data.
Innovating Personalized Nephrology Care: Exploring the Potential Utilization of ChatGPT
Miao, Jing , Suppadungsuk, Supawadee , Valencia, Oscar A. Garcia , Qureshi, Fawad , Cheungpasitporn, Wisit , Suppadungsuk, Supawadee , Garcia-Valencia, Oscar , Qureshi, Fawad , Cheungpasitporn, Wisit , Miao, Jing , Thongprayoon, Charat

Journal of Personalized Medicine | December 4, 2023 | Volume: 13 | Issue: 12 | Pages: 1681

10.3390/jpm13121681 | PMID 38138908 Get It

The rapid advancement of artificial intelligence (AI) technologies, particularly machine learning, has brought substantial progress to the field of nephrology, enabling significant improvements in the management of kidney diseases. ChatGPT, a revolutionary language model developed by OpenAI, is a versatile AI model designed to engage in meaningful and informative conversations. Its applications in healthcare have been notable, with demonstrated proficiency in various medical knowledge assessments. However, ChatGPT’s performance varies across different medical subfields, posing challenges in nephrology-related queries. At present, comprehensive reviews regarding ChatGPT’s potential applications in nephrology remain lacking despite the surge of interest in its role in various domains. This article seeks to fill this gap by presenting an overview of the integration of ChatGPT in nephrology. It discusses the potential benefits of ChatGPT in nephrology, encompassing dataset management, diagnostics, treatment planning, and patient communication and education, as well as medical research and education. It also explores ethical and legal concerns regarding the utilization of AI in medical practice. The continuous development of AI models like ChatGPT holds promise for the healthcare realm but also underscores the necessity of thorough evaluation and validation before implementing AI in real-world medical scenarios. This review serves as a valuable resource for nephrologists and healthcare professionals interested in fully utilizing the potential of AI in innovating personalized nephrology care.
CAMTA1‐related disorder: Phenotypic and molecular characterization of 26 new individuals and literature review
Al‐Kateb, Hussam , Démurger, Florence , Fluss, Joël , Isidor, Bertrand , Varvagiannis, Konstantinos, Koolen, David A. , McDonald, Marie , Moortgat, Stéphanie , Deprez, Marie, Karadurmus, Deniz , Paulsen, Julie , Rieger, Melissa, Willing, Marcia, McDonald, M , Shinawi, Marwan , Au, Ping Yee Billie , Berland, Siren , Cogné, Benjamin , Frank, L. Matthew, Montgomery, Sarah E. , Reis, André , Vasileiou, Georgia , Shinawi, Marwan

Clinical Genetics | December 4, 2023 | Volume: 105 | Issue: 3 | Pages: 294-301

10.1111/cge.14464 | PMID 38044714 Get It

Abstract Calmodulin‐binding transcriptional activator 1 (CAMTA1) is highly expressed in the brain and plays a role in cell cycle regulation, cell differentiation, regulation of long‐term memory, and initial development, maturation, and survival of cerebellar neurons. The existence of human neurological phenotypes, including cerebellar dysfunction with variable cognitive and behavioral abnormalities (CECBA), associated with CAMTA1 variants, has further supported its role in brain functions. In this study, we phenotypically and molecularly characterize the largest cohort of individuals ( n = 26) with 23 novel CAMTA1 variants (frameshift‐7, nonsense‐6, splicing‐1, initiation codon‐1, missense‐5, and intragenic deletions‐3) and compare the findings with all previously reported cases (total = 53). We show that the most notable phenotypic findings are developmental delay/intellectual disability, unsteady or uncoordinated gait, hypotonia, behavioral problems, and eye abnormalities. In addition, there is a high incidence of dysarthria, dysgraphia, microcephaly, gastrointestinal abnormalities, sleep difficulties, and nonspecific brain MRI findings; a few of which have been under‐reported. More than one third of the variants in this cohort were inherited from an asymptomatic or mildly affected parent suggesting reduced penetrance and variable expressivity. Our cohort provides a comprehensive characterization of the spectrum of phenotypes and genotypes among individuals with CECBA and the large data will facilitate counseling and formulating management plans and surveillance recommendations for these individuals.
Clinical specificity of two assays for immunoglobulin kappa and lambda free light chains
Roemmich, Brittany, Spears, Grant M. , Murray, David , Farnsworth, Christopher W , Dispenzieri, Angela , Willrich, Maria Alice V.

Clinical Chemistry and Laboratory Medicine (CCLM) | December 4, 2023 | Volume: 62 | Issue: 5 | Pages: 929-938

10.1515/cclm-2023-0912 | PMID 38044587 Get It

Abstract Objectives Free light chain (FLC) assays and the ratio of κ/λ are recommended for diagnosis, prognosis and monitoring of plasma cell dyscrasias (PCD). Limited data exists on FLC clinical specificity in patients diagnosed with other conditions. Methods We assessed the κ, λ, and κ/λ FLC ratio using the FreeLite assay and the Sebia FLC ELISA assay in 176 patients with clinical presentations of fatigue, anemia, polyclonal hypergammaglobulinemia, joint disorders, kidney disease and non PCD-cancers with no monoclonal protein observed on serum protein electrophoresis or MASS-FIX immunoglobulin isotyping. Manufacturer defined reference intervals (RI) and glomerular filtration rate (GFR) specific RI (renal RI) were utilized. Results For the κ/λ ratio, 68.7 % (121/176) of specimens on the FreeLite and 87.5 % (154/176) of specimens on the Sebia assay were within RI. For κ, 68.2 % (120/176) and 72.2 % (127/176) of results were outside RI for FreeLite and Sebia respectively. For λ, 37.5 % (66/176) and 84.1 % (148/176) of FreeLite and Sebia results were outside RI. With FreeLite and Sebia, patients with kidney disease (n=25) had the highest κ/λ ratios. 44 patients (25.0 %) had GFR <60 mL/min/BSA. When renal RI were applied, 13.6 % had a FLCr outside the renal RI with FreeLite, and 4.5 % with Sebia. Conclusions In a cohort of patients with signs and symptoms suggestive of PCDs, but ultimately diagnosed with other conditions, Sebia FLC had improved clinical specificity relative to FreeLite, if one was using an abnormal κ/λ ratio as a surrogate for monoclonality.
Reperfusion therapies for ischemic stroke in dementia and cognitive impairment: A systematic review and meta-analysis
Bala, Fouzi , Betzner, William , McDonald, Jennifer S, Ganesh, Aravind , Béland, Benjamin , McDonald, Jennifer S, Ganesh, Aravind

International Journal of Stroke | December 3, 2023 | Volume: 19 | Issue: 8 | Pages: 867-875

10.1177/17474930231220186 | PMID 38044328 Get It

Background: Endovascular thrombectomy (EVT) and intravenous thrombolysis (IVT) have an unclear benefit in those with pre-stroke dementia or cognitive impairment, as these patients were often excluded from landmark stroke trials. We performed a systematic review and meta-analysis to assess the outcomes of IVT and EVT in these populations. Aims: Our systematic review, conforming to the Meta-Analysis of Observational Studies in Epidemiology guidelines, investigated studies on acute ischemic stroke patients with pre-stroke dementia or cognitive impairment treated with IVT or EVT. Primary outcome was favorable 90-day outcome (mRS 0–2). Secondary outcomes included 90-day mortality, symptomatic intracranial hemorrhage (SICH), and radiographic intracranial hemorrhage (ICH). Summary of review: Nine articles were identified, with five observational studies of IVT use in patients with (n = 1078) and without dementia (n = 2805) being selected for the meta-analysis. There were no significant differences in favorable outcome (adjusted OR: 0.61, 95% CI 0.24–1.59), mortality (unadjusted OR: 1.19, 95% CI 0.86–1.64), ICH (unadjusted OR: 1.32, 95% CI 0.79–2.19), and symptomatic ICH (unadjusted OR: 0.94, 95% CI 0.70–1.25) for patients undergoing IVT with pre-stroke dementia versus those without. One EVT study (n = 615 with dementia vs n = 9600 without) found no significant differences in outcomes apart from an increased odds of ICH for those with pre-existing dementia (adjusted OR: 1.57, 95% CI 1.03–2.40). A pooled analysis of three IVT studies showed no significant association of cognitive impairment (n = 93 vs n = 211 without) with all assessed outcomes, whereas a study of EVT found that pre-stroke cognitive impairment was associated with poor 90-day outcomes (mRS 3–6). Conclusion: These results suggest no substantial safety issues in the use of IVT or EVT for patients with pre-existing dementia or cognitive impairment compared to those without. However, the efficacy of these therapies in this demographic remains uncertain. Further rigorous studies that include a more nuanced outcome measurement approach are warranted. Registration: URL: https://www.crd.york.ac.uk/PROSPERO/ ; Unique identifier: CRD42021240499.
Enhancement of Ultrasound Microbubble and Blood Flow Imaging using Similarity Measurement
Huang, Chengwu , Chen, Shigao , Knoll, Kate M , Huang, Chengwu

No container title available | December 3, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.36227/techrxiv.24635853.v1 Get It

Recent advancements in ultrasound technologies, such as ultrasound localization microscopy and ultrafast ultrasound Doppler, have enabled high-definition imaging of microvasculature. However, detecting weak microbubble or blood flow signals amid strong background noise remains a challenge, particularly in deep tissues. This study aims to enhance the signal contrast of microbubble and blood flow by leveraging their distinct spatial-temporal coherence in comparison to undesired noise for robust microbubble detection and microvascular imaging. We propose to quantify the signal coherence based on similarity analysis of beamformed ultrasound microbubble/blood flow data within the plane wave imaging framework. A spatial pixel is considered more likely to be a true microbubble/blood flow signal with a higher level of similarity, which can be measured by either of the following methods: 1) spatially block-wise normalized cross-correlation between two compounded frames; 2) temporally normalized autocorrelation across multiple compounded frames; 3) normalized cross-correlation between two subsets of post-compounded frames; 4) normalized autocorrelation of the pre-compounded data across angular direction. The original microbubble/blood flow signal is then weighted by the similarity measurement on a pixel-by-pixel basis to generate images with an improved signal contrast. The robustness of the proposed methods was first demonstrated in both phantom experiments and in vivo microbubble data from kidney transplant. We further validated their feasibility in blood flow imaging without the use of microbubbles based on in vivo data of human liver and kidney. Significant contrast improvement was observed, facilitating better visualization and detection of both microbubble and noncontrast microflow signals, which indicates a great potential of the methods for improved microvascular imaging and widespread clinical translation.
Re‐assessing prolonged cold ischemia time in kidney transplantation through machine learning consensus clustering
Thongprayoon, Charat , Tangpanithandee, Supawit , Punukollu, Rachana , Leeaphorn, Napat , Cooper, Matthew , Cheungpasitporn, Wisit , Jadlowiec, Caroline , Thongprayoon, Charat , Tangpanithandee, Supawit , Punukollu, Rachana , Leeaphorn, Napat , Cooper, Matthew , Cheungpasitporn, Wisit , Jadlowiec, Caroline C.

Clinical Transplantation | December 2, 2023 | Volume: 38 | Issue: 1 | Pages: No page available

10.1111/ctr.15201 | PMID 38041480 Get It

AbstractBackgroundWe aimed to cluster deceased donor kidney transplant recipients with prolonged cold ischemia time (CIT) using an unsupervised machine learning approach.MethodsWe performed consensus cluster analysis on 11 615 deceased donor kidney transplant patients with CIT exceeding 24 h using OPTN/UNOS data from 2015 to 2019. Cluster characteristics of clinical significance were identified, and post‐transplant outcomes were compared.ResultsConsensus cluster analysis identified two clinically distinct clusters. Cluster 1 was characterized by young, non‐diabetic patients who received kidney transplants from young, non‐hypertensive, non‐ECD deceased donors with lower KDPI scores. In contrast, the patients in cluster 2 were older and more likely to have diabetes. Cluster 2 recipients were more likely to receive transplants from older donors with a higher KDPI. There was lower use of machine perfusion in Cluster 1 and incrementally longer CIT in Cluster 2. Cluster 2 had a higher incidence of delayed graft function (42% vs. 29%), and lower 1‐year patient (95% vs. 98%) and death‐censored (95% vs. 97%) graft survival compared to Cluster 1.ConclusionsUnsupervised machine learning characterized deceased donor kidney transplant recipients with prolonged CIT into two clusters with differing outcomes. Although Cluster 1 had more favorable recipient and donor characteristics and better survival, the outcomes observed in Cluster 2 were also satisfactory. Overall, both clusters demonstrated good survival suggesting opportunities for transplant centers to incrementally increase CIT.