Citations

Mayo Clinic

Clear

35 citation(s) found for "Herman, Michael".

A Pareto‐based beam orientation optimization method for spot scanning intensity‐modulated proton therapy
Sayed, Hisham, Herman, Michael , Beltran, Chris , Beltran, Chris J

Medical Physics | February 20, 2020 | Volume: 47 | Issue: 5 | Pages: 2049-2060

10.1002/mp.14096 | PMID 32077497 Get It

PurposeTo provide a proof of principle of a Pareto‐based method to automatically generate optimal intensity‐modulated proton therapy (IMPT) plans for various noncoplanar beam orientations.MethodsA novel multicriteria beam orientation optimization (MCBOO) method was developed to generate Pareto database of optimal plans. The MCBOO method automatically explores the beam orientations and the scalarization parameters of the IMPT plans simultaneously. The MCBOO method is based on multicriteria bilevel optimization (i.e., hierarchical optimization with two nested levels, named the upper and lower level optimization). In MCBOO, the upper level optimization explores the noncoplanar beam orientation space, while the lower level explores the scalarization parameters for a given beam orientation. Differential evolution method was used in both levels, and the Pareto optimal plans were aggregated from the bilevel optimizations to construct the Pareto database. The MCBOO method was implemented on a multinode multi‐GPU cluster, and it was tested on three brain tumor patient cases. The Pareto database of the three patients was generated for a set of DVH‐based objectives. A statistical analysis was performed between a selected set of MCBOO plans and the manual plan (plan with manually selected beam orientation based on the clinical experience and optimized with the same single plan iterative optimizer used in the MCBOO). The selected set of MCBOO plans consisted of plans that matched the performance of the manual plan [i.e., MCBOO plans that have the same target coverage (within 2%) as the manual plan or better and achieved the same dose (within 2%) or lower to all of the organs at risks (OARs) but one OAR]. Additionally, a dosimetric comparison between of one of the selected MCBOO plans vs the manual plan was conducted.ResultsThe multicriteria beam orientation optimization algorithm automatically generated Pareto plans for the three noncoplanar brain tumor cases. The MCBOO plans provided an alternative objective trade‐offs to the manual plan. The selected MCBOO plans showed a reduction in dose to multiple organs at risk vs the manual plan with a maximum value which ranged between 10.8 and 12.9 Gy for the three patients. The trade‐off of the OAR dose reduction resulted in higher dose to no more than one OAR for each of the selected MCBOO plans vs the manual plan. The maximum dose increase in the MCBOO plans over the manual plan ranged from 7.8 to 11.8 Gy.ConclusionsA novel multicriteria beam orientation optimization method was developed and tested on three IMPT patient cases. The method automatically generates Pareto plans database by exploring the noncoplanar beam orientations. The method was able to identify beam orientations with Pareto optimal plans that are comparable to the manually created plans with varying objective trade‐offs.
Preoperative serum artemin (ARTN) as a predictive biomarker of recurrence following curative resection for hepatocellular carcinoma (HCC).
Feng, Sophie , Bucur, Roxana , Aggarwal, Reenika , Ray, Monali, Herman, Michael, Cheng, Dangxiao , Zhang, Wenjiang, Greig, Paul D., Moulton, Carol-Anne, McGilvray, I., Gallinger, Steven , Chen, Eric Xueyu, Sim, Hao‐Wen , Abreu, Phillipe , Chen, Zhuo , Wei, Alice C. , Cleary, Sean P. , Sapisochín, Gonzalo , Knox, Jennifer J. , Liu, Geoffrey

Journal of Clinical Oncology | February 4, 2020 | Volume: 38 | Issue: 4_suppl | Pages: 571-571

10.1200/jco.2020.38.4_suppl.571 Get It

571 Background: Tumor-induced generation of splenic erythroblast- like cells (Ter-cells) has been shown to promote tumor progression. These Ter-cells produce the glial-line derived neurotropic factor, ARTN. We investigated the association of pre-operative serum ARTN and the risk of recurrence in HCC patients (pts) undergoing curative resection. Methods: Blood samples were collected prior to surgery as part of an institutional molecular epidemiologic study. Serum ARTN concentration was measured using an enzyme-linked immunosorbent assay (ELISA). Demographics, pathological variables known to be associated with outcomes and clinical outcomes were collected. Uni- and multi-variate analysis were conducted. The optimal cutpoint method was used to define high and low ARTN concentrations. Cox models (hazard ratios, HR) were used to compare progression-free (PFS, primary endpoint), and overall survival (OS) of pts with high vs low serum ARTN. Results: Pre-operative blood samples were available for 58 pts. Median age was 63 years (range: 25-85 years); 74% were male and 50% were Asian. Etiology of liver disease was hepatitis B (43%) and hepatitis C (22%); 43% of tumors were ≤5cm, and vascular invasion was seen in 62%. A baseline alpha-fetoprotein (AFP) of > 100 mcg/L was observed in 36% pts. Median follow-up was 18.9 months. Median ARTN concentration was 0.322 ng/mL. The optimal ARTN concentration cut-off was 0.206 ng/mL. Median PFS for pts with high ( > 0.206 ng/mL) vs low (≤0.206 ng/mL) ARTN was 15.7 vs 55 months (p = 0.04) respectively. Three year PFS was 34% vs 55%, and three year OS 54% vs 91% for high vs low groups. Univariate analysis found that high ARTN concentration (HR 2.44, p = 0.05) and multifocal tumors were associated with a worse PFS. In a multivariate analysis adjusted for AFP > 100mcg/L, vascular invasion, hepatitis status and multifocal tumors, high ARTN remained a negative prognostic factor for PFS, aHR 3.32 (95% CI: 1.22-9.05, p = 0.02). Conclusions: A high pre-surgery serum ARTN is associated with earlier recurrence in HCC pts undergoing curative resection. ARTN should be further studied in HCC to determine its value as a prognostic marker.
AAPM medical physics practice guideline 7.a.: Supervision of medical physicist assistants
Seibert, J. Anthony , Blatnica, A, Clements, Jessica B., Halvorsen, Per H. , Herman, Michael , Johnson, Jennifer L. , Schueler, Beth A. , Martin, Melissa , Palta, Jatinder , Pfeiffer, D , Pizzutiello, R, Prisciandaro, Joann I. , Sherouse, George W., Herman, Michael G.

Journal of Applied Clinical Medical Physics | December 4, 2019 | Volume: 21 | Issue: 7 | Pages: 11-15

10.1002/acm2.12774 | PMID 31800151 Get It

AbstractThe American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM’s Executive Committee May 28, 2019
Optimization of motion management parameters in a synchrotron‐based spot scanning system
Johnson, J. , Herman, Michael , Kruse, Jon J. , Johnson, Jedediah E, Herman, Michael G.

Journal of Applied Clinical Medical Physics | September 20, 2019 | Volume: 20 | Issue: 9 | Pages: 69-77

10.1002/acm2.12702 | PMID 31538720 Get It

AbstractPurposeTo quantify the effects of combining layer‐based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot‐scanning proton delivery.MethodsAn analytic routine modeled three‐dimensional dose distributions of pencil‐beam proton plans delivered to a moving target. Spot positions and weights were established for a single field to deliver 100 cGy to a static, 15‐cm deep, 3‐cm radius spherical clinical target volume with a 1‐cm isotropic internal target volume expansion. The interplay effect was studied by modeling proton delivery from a clinical synchrotron‐based spot scanning system and respiratory target motion, patterned from surrogate patient breathing traces. Motion both parallel and orthogonal to the beam scanning direction was investigated. Repainting was modeled using a layer‐based technique. For each of 13 patient breathing traces, the dose from 20 distinct delivery schemes (combinations of four gate window amplitudes and five repainting techniques) was computed. Delivery strategies were inter‐compared based on target coverage, dose homogeneity, high dose spillage, and delivery time.ResultsNotable degradation and variability in plan quality were observed for ungated delivery. Decreasing the gate window reduced this variability and improved plan quality at the expense of longer delivery times. Dose deviations were substantially greater for motion orthogonal to the scan direction when compared with parallel motion. Repainting coupled with gating was effective at partially restoring dosimetric coverage at only a fraction of the delivery time increase associated with very small gate windows alone. Trends for orthogonal motion were similar, but more complicated, due to the increased severity of the interplay.ConclusionsLayer‐based repainting helps suppress the interplay effect from intra‐gate motion, with only a modest penalty in delivery time. The magnitude of the improvement in target coverage is strongly influenced by individual patient breathing patterns and the tumor motion trajectory.
The Medical Physicist in the balance
Herman, Michael , Herman, Michael G.

Journal of Applied Clinical Medical Physics | June 24, 2019 | Volume: 20 | Issue: 7 | Pages: 4-6

10.1002/acm2.12669 | PMID 31231922 Get It

Soft tissue sarcoma stiffness and perfusion evaluation by MRE and DCE-MRI for radiation therapy response assessment: a technical feasibility study
Pepin, Kay , Grimm, Roger C., Howe, B. Matthew, Fritchie, Karen , Frick, Matthew A., Wenger, Doris E. , Okuno, Scott H. , McGee, Kiaran P. , James, Sarah, Laack, Nadia N., Herman, Michael , Pafundi, Deanna, Grimm, Roger, Kargar, Soudabeh , Frick, Matthew, Wenger, Doris, Ehman, Richard, McGee, Kiaran , Ehman, Richard L.

Biomedical Physics & Engineering Express | May 13, 2019 | Volume: 5 | Issue: 4 | Pages: 047003

10.1088/2057-1976/ab2175 | PMID 32110433 Get It

Abstract Soft tissue sarcomas are a rare and heterogeneous group of malignancies that present significant diagnostic and therapeutic challenges. Patient stratification based on tumor aggressiveness and early therapeutic response based on quantitative imaging may improve prediction of treatment response and the evaluation of new treatment strategies in clinical trials. The purpose of this pilot study was to determine the technical feasibility of magnetic resonance elastography (MRE) and dynamic contrast-enhanced (DCE) MRI for the evaluation of sarcoma stiffness and perfusion in 9 patients with histologically confirmed sarcoma. Additionally, we assessed the feasibility of utilizing MRE and DCE-MRI for the early evaluation of response to radiation therapy in 4 patients to determine the utility of further evaluation in a larger cohort study. Tumor size, stiffness, and perfusion parameters all decreased from baseline at the time of the pre-surgery or follow-up MRI, and results were compared to pathology or conventional imaging. MRE and DCE-MRI may be useful for the quantitative evaluation of tumor stiffness and perfusion, and therapy response assessment in soft tissue sarcomas.
Clinical implementation of respiratory‐gated spot‐scanning proton therapy: An efficiency analysis of active motion management
Gelover, Edgar, Deisher, A., Herman, Michael , Johnson, J. , Kruse, Jon J. , Tryggestad, E., Deisher, Amanda J, Herman, Michael G., Johnson, Jedediah E, Tryggestad, Erik J

Journal of Applied Clinical Medical Physics | April 11, 2019 | Volume: 20 | Issue: 5 | Pages: 99-108

10.1002/acm2.12584 | PMID 30972922 Get It

AbstractPurposeThe aim of this work is to describe the clinical implementation of respiratory‐gated spot‐scanning proton therapy (SSPT) for the treatment of thoracic and abdominal moving targets. The experience of our institution is summarized, from initial acceptance and commissioning tests to the development of standard clinical operating procedures for simulation, motion assessment, motion mitigation, treatment planning, and gated SSPT treatment delivery.Materials and methodsA custom respiratory gating interface incorporating the Real‐Time Position Management System (RPM, Varian Medical Systems, Inc., Palo Alto, CA, USA) was developed in‐house for our synchrotron‐based delivery system. To assess gating performance, a motion phantom and radiochromic films were used to compare gated vs nongated delivery. Site‐specific treatment planning protocols and conservative motion cutoffs were developed, allowing for free‐breathing (FB), breath‐holding (BH), or phase‐gating (Ph‐G). Room usage efficiency of BH and Ph‐G treatments was retrospectively evaluated using beam delivery data retrieved from our record and verify system and DICOM files from patient‐specific quality assurance (QA) procedures.ResultsMore than 70 patients were treated using active motion management between the launch of our motion mitigation program in October 2015 and the end date of data collection of this study in January 2018. During acceptance procedures, we found that overall system latency is clinically‐suitable for Ph‐G. Regarding room usage efficiency, the average number of energy layers delivered per minute was <10 for Ph‐G, 10‐15 for BH and ≥15 for FB, making Ph‐G the slowest treatment modality. When comparing to continuous delivery measured during pretreatment QA procedures, the median values of BH treatment time were extended from 6.6 to 9.3 min (+48%). Ph‐G treatments were extended from 7.3 to 13.0 min (+82%).ConclusionsActive motion management has been crucial to the overall success of our SSPT program. Nevertheless, our conservative approach has come with an efficiency cost that is more noticeable in Ph‐G treatments and should be considered in decision‐making.
Adaptive method for multicriteria optimization of intensity‐modulated proton therapy
Kamal‐Sayed, Hisham, Tseung, H. Wan Chan, Herman, Michael , Beltran, Chris , Beltran, Chris J , Ma, J., Abdel‐Rehim, A.

Medical Physics | October 17, 2018 | Volume: 45 | Issue: 12 | Pages: 5643-5652

10.1002/mp.13239 | PMID 30332515 Get It

PurposeProvide an adaptive multicriteria optimization (MCO) method for intensity‐modulated proton therapy (IMPT) utilizing GPU technology. Previously described limitations of MCO such as Pareto approximation and limitation on the number of objectives were addressed.MethodsThe treatment planning process for IMPT must account for multiple objectives, which requires extensive treatment planning resources. Often a large number of objectives (>10) are required. Hence the need for an MCO algorithm that can handle large number of objectives. The novelty of the MCO method presented here lies on the introduction of the adaptive weighting scheme that can generate a well‐distributed and dense representation of the Pareto surface for a large number of objectives in an efficient manner. In our approach the generated Pareto surface is constructed for a set of DVH objectives. The MCO algorithm is based on the augmented weighted Chebychev metric (AWCM) method with an adaptive weighting scheme. This scheme uses the differential evolution (DE) method to generate a set of well‐distributed Pareto points. The quality of the Pareto points’ distribution in the objective space was assessed quantitatively using the Pareto sampling metric. The MCO algorithm was developed to perform multiple parallel searches to achieve a rapid mapping of the Pareto surface, produce clinically deliverable plans, and was implemented on a GPU cluster. The MCO algorithm was tested on two clinical cases with 10 and 18 objectives. For each case one of the MCO‐generated plans was selected for comparison with the clinically generated plan. The MCO plan was randomly selected out of the set of MCO plans that had target coverage similar to the clinically generated plan and the same or better sparing of the organs at risk (OAR). Additionally, a validation study of the AWCM method vs the weighted sum method was performed.ResultsThe adaptive MCO algorithm generated Pareto points on the Pareto hypersurface in a fast (2–3 hr) and efficient manner for 2 cases with 10 and 18 objectives. The MCO algorithm generated a dense and well‐distributed set of Pareto points on the objective space, and was able to achieve minimization of the Pareto sampling metric. The selected MCO plan showed an improvement of the DVH objectives in comparison to the clinically optimized plan in both cases. For case one, the MCO plan showed a 48% reduction of the 50% dose to OARs and a 16% reduction of the 1% dose to OARs. For case 2, the MCO plan showed a 72% reduction of the 50% dose to OARs and a 42% reduction of the 1% dose to OARs. The comparison of AWCM to WS showed that the AWCM method has a dosimetric advantage over WS for both patient cases.ConclusionWe introduced an adaptive MCO algorithm for IMPT accelerated using GPUs. The algorithm is based on an adaptive method for generating Pareto plans in the objective space. We have shown that the algorithm can provide rapid and efficient mapping of the multicriteria Pareto surface with clinically deliverable plans.
A Monte‐Carlo‐based and GPU‐accelerated 4D‐dose calculator for a pencil beam scanning proton therapy system
Pepin, M. , Tryggestad, E., Tseung, Hok Seum Wan Chan, Johnson, J. , Herman, Michael , Beltran, Chris , Pepin, Mark D, Tryggestad, Erik, Wan Chan Tseung, Hok Seum, Johnson, Jedediah E, Herman, Michael G., Beltran, Chris J , Pepin, Mark D

Medical Physics | September 11, 2018 | Volume: 45 | Issue: 11 | Pages: 5293-5304

10.1002/mp.13182 | PMID 30203550 Get It

PurposeThe presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this degraded four‐dimensional (4D) dose, they typically have one or more deficiencies such as not including the particular effects from a dynamic delivery, using analytical dose calculations, and/or using nonphysical dose‐accumulation methods. This work presents a clinically useful 4D‐dose calculator that addresses each of these shortcomings.MethodsTo quickly compute the 4D dose, the three main tasks of the calculator were run on graphics processing units (GPUs). These tasks were (a) simulating the delivery of the plan using measured delivery parameters to distribute the plan amongst 4DCT phases characterizing the patient breathing, (b) using an in‐house Monte Carlo simulation (MC) dose calculator to determine the dose delivered to each breathing phase, and (c) accumulating the doses from the various breathing phases onto a single phase for evaluation. The accumulation was performed by individually transferring the energy and mass of dose‐grid subvoxels, a technique that models the transfer of dose in a more physically realistic manner. The calculator was run on three test cases, with lung, esophagus, and liver targets, respectively, to assess the various uncertainties in the beam delivery simulation as well as to characterize the dose‐accumulation technique.ResultsFour‐dimensional doses were successfully computed for the three test cases with computation times ranging from 4–6 min on a server with eight NVIDIA Titan X graphics cards; the most time‐consuming component was the MC dose engine. The subvoxel‐based dose‐accumulation technique produced stable 4D‐dose distributions at subvoxel scales of 0.5–1.0 mm without impairing the total computation time. The uncertainties in the beam delivery simulation led to moderate variations of the dose–volume histograms for these cases; the variations were reduced by implementing repainting or phase‐gating motion mitigation techniques in the calculator.ConclusionsA MC‐based and GPU‐accelerated 4D‐dose calculator was developed to estimate the effects of respiratory motion on pencil beam scanning proton therapy treatments. After future validation, the calculator could be used to assess treatment plans and its quick runtime would make it easily usable in a future 4D‐robust optimization system.
P298Safety of catheter-free VT ablation: Dose-dependent LVEF changes after proton beam therapy of the LV in a porcine model
Deisher, A., Suzuki, Akihiro , Kruse, Jon J. , Parker, Katrina, Newman, Laura K. , Herman, Michael , Packer, Douglas L. , Hohmann, Stephan , Konishi, Hiroki , Rettmann, Maryam E. , Lehmann, H. Immo

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy564.p298 Get It