Prospective Study of Slip-interface Imaging in Meningioma for Brain-tumor Adhesion
ElSheikh, Mona M., Link, Michael J. , Meyer, Fredrick B., III, John, Hughes, Joshua , Yin, Ziying , Gompel, Jamie J. Van , Arani, Arvin , Ehman, Richard L.

Journal of Neurological Surgery Part B: Skull Base | March 3, 2017 | Volume: 78 | Issue: S 01 | Pages: S1-S156

10.1055/s-0037-1600549 Get It

Magnetic Resonance Elastography in Vestibular Schwannoma
ElSheikh, Mona M., Fattahi, Nikoo , Link, Michael J. , Hughes, Joshua , Yin, Ziying , Gompel, Jamie J. Van , Arani, Arvin , Ehman, Richard L. , Huston, John

Journal of Neurological Surgery Part B: Skull Base | March 3, 2017 | Volume: 78 | Issue: S 01 | Pages: S1-S156

10.1055/s-0037-1600542 Get It

Cardiac MR elastography for quantitative assessment of elevated myocardial stiffness in cardiac amyloidosis
Arani, Arvin , Arunachalam, Shivaram P. , Chang, Ian C , Baffour, Francis , Rossman, Phillip J. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Grogan, Martha , Dispenzieri, Angela , Araoz, Philip A. , Chang, Ian C Y, Manduca, Armando , Ehman, Richard L. , Dispenzieri, Angela , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Journal of Magnetic Resonance Imaging | February 25, 2017 | Volume: 46 | Issue: 5 | Pages: 1361-1367

10.1002/jmri.25678 | PMID 28236336 Get It

PurposeTo evaluate if cardiac magnetic resonance elastography (MRE) can measure increased stiffness in patients with cardiac amyloidosis. Myocardial tissue stiffness plays an important role in cardiac function. A noninvasive quantitative imaging technique capable of measuring myocardial stiffness could aid in disease diagnosis, therapy monitoring, and disease prognostic strategies. We recently developed a high‐frequency cardiac MRE technique capable of making noninvasive stiffness measurements.Materials and MethodsIn all, 16 volunteers and 22 patients with cardiac amyloidosis were enrolled in this study after Institutional Review Board approval and obtaining formal written consent. All subjects were imaged head‐first in the supine position in a 1.5T closed‐bore MR imager. 3D MRE was performed using 5 mm isotropic resolution oblique short‐axis slices and a vibration frequency of 140 Hz to obtain global quantitativein vivoleft ventricular stiffness measurements. The median stiffness was compared between the two cohorts. An octahedral shear strain signal‐to‐noise ratio (OSS‐SNR) threshold of 1.17 was used to exclude exams with insufficient motion amplitude.ResultsFive volunteers and six patients had to be excluded from the study because they fell below the 1.17 OSS‐SNR threshold. The myocardial stiffness of cardiac amyloid patients (median: 11.4 kPa, min: 9.2, max: 15.7) was significantly higher (P = 0.0008) than normal controls (median: 8.2 kPa, min: 7.2, max: 11.8).ConclusionThis study demonstrates the feasibility of 3D high‐frequency cardiac MRE as a contrast‐agent‐free diagnostic imaging technique for cardiac amyloidosis.Level of Evidence:2Technical Efficacy:Stage 2J. Magn. Reson. Imaging 2017;46:1361–1367.
Slip interface imaging based on MR‐elastography preoperatively predicts meningioma–brain adhesion
Yin, Ziying , Hughes, Joshua , Glaser, Kevin J. , Link, Michael J. , Romano, Anthony J., Hughes, Joshua D, Trzasko, Joshua D. , Van Gompel, Jamie, Manduca, Armando , Gompel, Jamie J. Van , Ehman, Richard L. , Huston, John , Yin, Ziying

Journal of Magnetic Resonance Imaging | February 14, 2017 | Volume: 46 | Issue: 4 | Pages: 1007-1016

10.1002/jmri.25623 | PMID 28194925 Get It

PurposeTo investigate the ability of slip interface imaging (SII), a recently developed magnetic resonance elastography (MRE)‐based technique, to predict the degree of meningioma–brain adhesion, using findings at surgery as the reference standard.Materials and MethodsWith Institutional Review Board approval and written informed consent, 25 patients with meningiomas >2.5 cm in maximal diameter underwent preoperative SII assessment. Intracranial shear motions were introduced using a soft, pillow‐like head driver and the resulting displacement field was acquired with an MRE pulse sequence on 3T MR scanners. The displacement data were analyzed to determine tumor–brain adhesion by assessing intensities on shear line images and raw as well as normalized octahedral shear strain (OSS) values along the interface. The SII findings of shear line images, OSS, and normalized OSS were independently and blindly correlated with surgical findings of tumor adhesion by using the Cohen's κ coefficient and chi‐squared test.ResultsNeurosurgeons categorized the surgical plane as extrapial (no adhesion) in 15 patients, mixed in four, and subpial (adhesion) in six. Both shear line images and OSS agreed with the surgical findings in 18 (72%) cases (fair agreement, κ = 0.37, 95% confidence interval [CI]: 0.05–0.69), while normalized OSS was concordant with the surgical findings in 23 (92%) cases (good agreement, κ = 0.86, 95% CI: 0.67–1). The correlation between SII predictions (shear line images, OSS, and normalized OSS) and the surgical findings were statistically significant (chi‐squared test, P = 0.02, P = 0.02, and P < 0.0001, respectively).ConclusionSII preoperatively evaluates the degree of meningioma–brain adhesion noninvasively, allowing for improved prediction of surgical risk and tumor resectability.Level of Evidence: 1Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2017;46:1007–1016.
Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography
Marinelli, John P. , Levin, David L. , Vassallo, Robert , Carter, Rickey E. , Hubmayr, Rolf D., McGee, Kiaran P. , Ehman, Richard L. , Vassallo, Robert , Carter, Rickey E

Journal of Magnetic Resonance Imaging | January 24, 2017 | Volume: 46 | Issue: 2 | Pages: 365-374

10.1002/jmri.25579 | PMID 28117930 Get It

PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence: 1Technical Efficacy: Stage 2J. MAGN. RESON. IMAGING 2017;46:365–374
Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity
Yin, Meng , Talwalkar, Jayant A., Oudry, Jennifer, Glaser, Kevin J. , Smyrk, Thomas C. , Miette, Véronique , Sandrin, Laurent , Chen, Jun , Ehman, Richard L. , Miette, Veronique , Yin, Meng

Radiology | November 18, 2016 | Volume: 283 | Issue: 2 | Pages: 418-428

10.1148/radiol.2016160685 | PMID 27861111 Get It

Comparison of diagnostic accuracies of two‐ and three‐dimensional MR elastography of the liver
Morisaka, Hiroyuki , Glaser, Kevin J. , Ichikawa, Shintaro , Sano, Katsuhiro , Ichikawa, Tomoaki, Motosugi, Utaroh , Ehman, Richard L. , Onishi, Hiroshi

Journal of Magnetic Resonance Imaging | September 23, 2016 | Volume: 45 | Issue: 4 | Pages: 1163-1170

10.1002/jmri.25425 | PMID 27662640 Get It

PurposeTo evaluate the effect of imaging sequence (spin‐echo echo‐planar imaging [EPI] and gradient‐echo [GRE]) and postprocessing method (two‐dimensional [2D] and 3D inversion algorithms) on liver MR elastography (MRE) and to validate the diagnostic performance of EPI‐MRE3D versus conventional GRE‐MRE2D for liver fibrosis staging.Materials and MethodsThree MRE methods (EPI‐MRE3D, EPI‐MRE2D, and GRE‐MRE2D) were performed on soft and mildly stiff phantoms and 58 patients with chronic liver disease using a 3 Tesla clinical MRI scanner, and stiffness values were compared among the three methods. A validation study comprised 73 patients with histological liver fibrosis (F0–4, METAVIR system). Areas under the receiver operating characteristic curves (AUCs) and accuracies for diagnosing significant fibrosis (F3–4) and cirrhosis (F4) were compared between EPI‐MRE3D and GRE‐MRE2D.ResultsStiffness values of the soft and mildly stiff phantoms were 2.4 kPa and 4.0 kPa by EPI‐MRE3D; 2.6 kPa and 4.2 kPa by EPI‐MRE2D; and 2.7 kPa and 4.2 kPa by GRE‐MRE2D. In patients, EPI‐MRE3D provided significantly lower stiffness values than other methods (P < 0.001). However, there was no significant difference between GRE‐MRE2D and EPI‐MRE2D (P = 0.12). The AUCs and accuracies of EPI‐MRE3D and GRE‐MRE2D were statistically equivalent in the diagnoses of significant fibrosis (F3–4) and cirrhosis (F4) (all P < 0.005).ConclusionEPI‐MRE3D showed modestly lower liver stiffness values than conventional GRE‐MRE2D. The diagnostic performances of EPI‐MRE3D and GRE‐MRE2D were equivalent for liver fibrosis staging.Level of Evidence: 3J. Magn. Reson. Imaging 2017;45:1163–1170
Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis
Arunachalam, Shivaram P. , Rossman, Phillip J. , Arani, Arvin , Lake, David S. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin

Magnetic Resonance in Medicine | March 26, 2016 | Volume: 77 | Issue: 3 | Pages: 1184-1192

10.1002/mrm.26207 | PMID 27016276 Get It

Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Magnetic Resonance Elastography of the Liver
Wagner, Mathilde , Ayache, Jad Bou, Yasar, Temel Kaya, Bane, Octavia , Fung, Maggie , Besa, Cecilia , Ehman, Richard L. , Taouli, Bachir

Investigative Radiology | March 22, 2016 | Volume: 51 | Issue: 9 | Pages: 575-581

10.1097/rli.0000000000000269 | PMID 26982699 Get It

Objective The aim of this study was to compare 2-dimensional (2D) gradient recalled echo (GRE) and 2D spin echo echoplanar imaging (SE-EPI) magnetic resonance elastography (MRE) sequences of the liver in terms of image quality and quantitative liver stiffness (LS) measurement. Materials and Methods This prospective study involved 50 consecutive subjects (male/female, 33/17; mean age, 58 years) who underwent liver magnetic resonance imaging at 3.0 T including 2 MRE sequences, 2D GRE, and 2D SE-EPI (acquisition time 56 vs 16 seconds, respectively). Image quality scores were assessed by 2 independent observers based on wave propagation and organ coverage on the confidence map (range, 0–15). A third observer measured LS on stiffness maps (in kilopascal). Mean LS values, regions of interest size (based on confidence map), and image quality scores between SE-EPI and GRE-MRE were compared using paired nonparametric Wilcoxon test. Reproducibility of LS values between the 2 sequences was assessed using intraclass coefficient correlation, coefficient of variation, and Bland-Altman limits of agreement. T2* effect on image quality was assessed using partial Spearman correlation. Results There were 4 cases of failure with GRE-MRE and none with SE-EPI-MRE. Image quality scores and region of interest size were significantly higher using SE-EPI-MRE versus GRE-MRE (P < 0.0001 for both measurements and observers). Liver stiffness measurements were not significantly different between the 2 sequences (3.75 ± 1.87 kPa vs 3.55 ± 1.51 kPa, P = 0.062), were significantly correlated (intraclass coefficient correlation, 0.909), and had excellent reproducibility (coefficient of variation, 10.2%; bias, 0.023; Bland-Altman limits of agreement, −1.19; 1.66 kPa). Image quality scores using GRE-MRE were significantly correlated with T2* while there was no correlation for SE-EPI-MRE. Conclusions Our data suggest that SE-EPI-MRE may be a better alternative to GRE-MRE. The diagnostic performance of SE-EPI-MRE for detection of liver fibrosis needs to be assessed in a future study.