Citations

Mayo Clinic

Clear

166 citation(s) found for "Baddour, L M".

Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?
Peacock, James E. , Stafford, Jeanette M. , Le, Katherine, Sohail, M. Rizwan , Prutkin, Jordan M. , Danik, Stephan B., Vikram, Holenarasipur R. , Hernández‐Meneses, Marta , Blank, Elisabeth, Naber, Christoph, Carrillo, Roger G. , Greenspon, Arnold J. , Tseng, Chi‐Hong , Uslan, Daniel Z. , Vikram, Holenarasipur R. , Sohail, M Rizwan , Baddour, Larry M. , Miró, José María

Pacing and Clinical Electrophysiology | March 8, 2018 | Volume: 41 | Issue: 5 | Pages: 524-531

10.1111/pace.13319 | PMID 29518265 Get It

AbstractBackgroundPublished guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined.MethodsData from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified.ResultsOf 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). “Early failure” of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty‐six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced “late” salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase‐negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage.ConclusionsIn patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.
Statin use and the risk of cardiovascular implantable electronic device infection: A cohort study in a veteran population
Alzahrani, Talal , Liappis, Angelike P., Karasik, Pamela , Baddour, Larry M.

Pacing and Clinical Electrophysiology | January 17, 2018 | Volume: 41 | Issue: 3 | Pages: 284-289

10.1111/pace.13285 | PMID 29341172 Get It

AbstractBackgroundThe rate of cardiovascular implantable electronic device infection (CIEDI) has increased, despite the use of perioperative antibiotics at the time of device placement or revision. This is due, in part, to the presence of multiple comorbid conditions in an elderly population, in general, who require CIED. Statins may have an antibacterial effect, although there is currently no evidence that the likelihood of CIEDI has been impacted by statin use.MethodsA retrospective cohort study was performed to assess whether statins are associated with a reduced risk of CIEDI. The VA Informatics and Computing Infrastructure (VINCI) database, which includes all veterans who underwent CIED placement between 2008 and 2015, was used. A logistic regression model was constructed to estimate the adjusted risk of CIEDI among patients who were receiving statins after adjusting for confounding factors.ResultsOverall, 18,970 CIED procedures were included, and 98% of them were performed in men with a mean age of 71 ± 11 years. The rate of diabetes mellitus, heart failure, advanced chronic kidney diseases, CIEDI, positive methicillin‐resistant Staphylococcus aureus nasal colonization, and statin use were 23%, 15.7%, 3.3%, 1.14%, 12.6%, and 56%, respectively. The logistic regression analysis showed that statins were significantly associated with a reduced risk of CIEDI; after controlling for other effects, the reduction was 66% (odds ratio 0.34 [0.2–0.59], P‐value < 0.001). The effect of statins was confirmed by propensity score analysis.ConclusionsOur study showed that among patients receiving statins who had undergone CIED placement, there was a 66% reduction in subsequent CIEDI.
Single Versus Multidrug Regimen for Surgical Infection Prophylaxis in Left Ventricular Assist Device Implantation
Aburjania, Nana , Ertmer, Brennan, Farid, Saira, Berg, Melody L. , Nienaber, Juhsien J. C., Tchantchaleishvili, Vakhtang , Stulak, John M., Sohail, M. Rizwan , Ertmer, Brennan M, Sohail, Muhammad R, Sohail, M Rizwan , Tchantchaleishvili, Vakhtang , Baddour, Larry M.

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 6 | Pages: 735-740

10.1097/mat.0000000000000710 | PMID 29095735 Get It

Infection is a serious complication of left ventricular assist device (LVAD) therapy. However, an optimal antimicrobial surgical infection prophylaxis (SIP) regimen for LVAD implantation is not well established. We retrospectively reviewed all adults who underwent continuous-flow LVAD implantation from February 2007 to March 2015 at Mayo Clinic Rochester. Left ventricular assist device infection (LVADI) was defined using criteria published by the International Society for Heart and Lung Transplant. Patients excluded from the analysis included those who did not have HeartMate II or HeartWare device, patients with incomplete documentation of SIP, and those with an actively treated infection at the time of LVAD implantation. We compared risk of LVAD-specific and LVAD-related infections and all-cause mortality between SIP regimens at postoperative day 90 and 1 year using Kaplan–Meier time-to-event analyses. During study period, 239 adults underwent continuous-flow LVAD implantation at our institution where 199 patients received single-drug and 40 received multidrug SIP regimen. Median patient age was 62 years. Left ventricular assist device infection occurred in three patients (1.5%) in the single-drug group versus two patients (5.0%) in the multidrug group at 90 days (p = 0.4). There was no difference in infection-free (p = 0.4) and overall survival (p = 0.9) between two groups at 1 year. In conclusion, there was no clear benefit of using multidrug regimen as it did not impact infection-free survival or all-cause mortality compared with single-drug regimen. Prospective clinical trials are needed to further define the optimal SIP regimen for LVAD implantation.
Left Ventricular Assist Device Infections: A Systematic Review
O’Horo, John C. , Saleh, Omar Abu , Stulak, John M., Wilhelm, Mark , Sohail, M. Rizwan , Abu Saleh, Omar M, Wilhelm, Mark P, Sohail, M Rizwan , O'Horo, John C , Baddour, Larry M.

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 3 | Pages: 287-294

10.1097/mat.0000000000000684 | PMID 29095732 Get It

Left ventricular assist devices (LVADs) are becoming a more frequent life-support intervention. Gaining an understanding of risk factors for infection and management strategies is important for treating these patients. We conducted a systematic review and meta-analysis of studies describing infections in continuous-flow LVADs. We evaluated incidence, risk factors, associated microorganisms, and outcomes by type of device and patient characteristics. Our search identified 90 distinct studies that reported LVAD infections and outcomes. Younger age and higher body mass index were associated with higher rates of LVAD infections. Driveline infections were the most common infection reported and the easiest to treat with fewest long-term consequences. Bloodstream infections were not reported as often, but they were associated with stroke and mortality. Treatment strategies varied and did not show a consistent best approach. LVAD infections are a significant cause of morbidity and mortality in LVAD patients. Most research comes from secondary analyses of other LVAD studies. The lack of infection-oriented research leaves several areas understudied. In particular, bloodstream infections in this population merit further research. Providers need more research studies to make evidence-based decisions about the prevention and treatment of LVAD infections.
Quantifying infective endocarditis risk in patients with predisposing cardiac conditions
Thornhill, Martin H. , Jones, Simon , Prendergast, Bernard , Chambers, John B. , Lockhart, Peter B. , Thornhill, M H , Baddour, Larry M. , Dayer, Mark

European Heart Journal | October 24, 2017 | Volume: 39 | Issue: 7 | Pages: 586-595

10.1093/eurheartj/ehx655 | PMID 29161405 Get It

Abstract Aims There are scant comparative data quantifying the risk of infective endocarditis (IE) and associated mortality in individuals with predisposing cardiac conditions. Methods and results English hospital admissions for conditions associated with increased IE risk were followed for 5 years to quantify subsequent IE admissions. The 5-year risk of IE or dying during an IE admission was calculated for each condition and compared with the entire English population as a control. Infective endocarditis incidence in the English population was 36.2/million/year. In comparison, patients with a previous history of IE had the highest risk of recurrence or dying during an IE admission [odds ratio (OR) 266 and 215, respectively]. These risks were also high in patients with prosthetic valves (OR 70 and 62) and previous valve repair (OR 77 and 60). Patients with congenital valve anomalies (currently considered ‘moderate risk’) had similar levels of risk (OR 66 and 57) and risks in other ‘moderate-risk’ conditions were not much lower. Congenital heart conditions (CHCs) repaired with prosthetic material (currently considered ‘high risk’ for 6 months following surgery) had lower risk than all ‘moderate-risk’ conditions—even in the first 6 months. Infective endocarditis risk was also significant in patients with cardiovascular implantable electronic devices. Conclusion These data confirm the high IE risk of patients with a history of previous IE, valve replacement, or repair. However, IE risk in some ‘moderate-risk’ patients was similar to that of several ‘high-risk’ conditions and higher than repaired CHC. Guidelines for the risk stratification of conditions predisposing to IE may require re-evaluation.
Hospital costs for patients with lower extremity cellulitis: a retrospective population-based study
Challener, Douglas W. , Marcelin, Jasmine R , Visscher, Sue L. , Baddour, Larry M. , Challener, Douglas , Marcelin, Jasmine , Visscher, Sue, Baddour, Larry

Hospital Practice | September 23, 2017 | Volume: 45 | Issue: 5 | Pages: 196-200

10.1080/21548331.2017.1384690 | PMID 28944703 Get It

International survey of knowledge, attitudes, and practices of cardiologists regarding prevention and management of cardiac implantable electronic device infections
DeSimone, Daniel C. , Chahal, C. Anwar A. , Asirvatham, Samuel J. , Friedman, Paul A. , Sohail, M. Rizwan , Chahal, Anwar A, Friedman, Paul A , Asirvatham, Samuel J , Sohail, M Rizwan , Chahal, Choudhary Anwar A , DeSimone, Daniel C , DeSimone, Christopher V. , Baddour, Larry M.

Pacing and Clinical Electrophysiology | August 28, 2017 | Volume: 40 | Issue: 11 | Pages: 1260-1268

10.1111/pace.13183 | PMID 28846153 Get It

AbstractBackgroundCardiovascular implantable electronic devices (CIEDs) can be life‐saving. However, complications from CIED infection can be life‐threatening, often requiring device removal. Despite publication of CIED infection management guidelines, there remains marked variation in clinical practice.ObjectiveTo better understand and quantify these differences, we conducted a multinational survey of practitioners of CIED management.MethodsAn electronic survey was sent to Heart Rhythm Society members, spanning 70 countries across six continents. All responses were collected anonymously.Results227 out of 3,600 (6.3%) responded to the survey. The majority of surveys were completed by practitioners from the United States (168; 68.3%) and 53.8% of these practiced in academic medical centers. The large majority (92.7%) of sites had protocols to ensure appropriate timing of prophylactic antibiotics. Superficial (incisional) site infections were treated with antibiotics alone 52.5% of the time (consistent with guidelines); in contrast, deep pocket infections were treated with antibiotics (with device removal) in accordance to guidelines only 37.4% of the time. Almost all providers (98.7%) were inclined to perform complete hardware removal in cases of CIED‐related endocarditis. In contrast, 82.2% of survey participants suggested complete CIED system removal in patients with an occult Gram‐positive bacteremia, 65.5% with occult Gram‐negative bacteremia, and 59.3% with prolonged bacteremia due to a source other than CIED.ConclusionsThese data suggest wide variability in clinical practice in managing CIED infection with significant deviations from published guidelines. There is critical need to increase awareness and develop institutional protocols to ensure adherence with evidence‐based guidelines to optimize outcomes.
The incidence and outcomes from Clostridium difficile infection in hospitalized adults with inflammatory bowel disease
Saffouri, George, Loftus, Edward V. , Pardi, Darrell S. , Khanna, Sahil , Loftus, Edward V , Gupta, Arjun , Baddour, Larry M.

Scandinavian Journal of Gastroenterology | August 7, 2017 | Volume: 52 | Issue: 11 | Pages: 1240-1247

10.1080/00365521.2017.1362466 | PMID 28782372 Get It

Incidence of and Effects of Seasonality on Lower Extremity Cellulitis After the Emergence of Community-Acquired Methicillin-Resistant Staphylococcus aureus: A Population-based Study
Lahr, Brian D. , Marcelin, Jasmine R , Challener, Douglas W. , Tan, Eugene M. , Baddour, Larry M.

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.1061 Get It

Impact of a Care Process Model on Management of Cardiovascular Implantable Electronic Device Infections
Anderson, Brenda, Linderbaum, Jane A. , Ziel, Thomas De, Cha, Yong‐Mei , Loomis, Erica, Espinosa, Raúl E. , Friedman, Paul A. , Greason, Kevin L. , Schiller, Henry J., Virk, Abinash , Wilson, Walter R. , Steckelberg, James M., Tan, Eugene M. , Nagpal, Avish , DeSimone, Daniel C. , Li, Zhuo , Sohail, M. Rizwan , Baddour, Larry M.

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.811 Get It