Citations

Mayo Clinic

Showing 10 of 108117 citations.

DNA Integrity as a Potential Marker for Stool-based Detection of Colorectal Cancer
Boynton, Kevin A., Summerhayes, Ian C., Ahlquist, David A. , Shuber, Anthony P.

Clinical Chemistry | February 13, 2004 | Volume: 49 | Issue: 7 | Pages: 1058-1065

10.1373/49.7.1058 | PMID 12816901 Get It

AbstractBackground: Molecular genetic analysis of DNA in patient stools has been proposed for screening of colorectal cancer (CRC). Because nonapoptotic cells shed from tumors may contain DNA that is less degraded than DNA fragments from healthy colonic mucosa, our aim was to show that DNA fragments isolated from stools of patients with CRC had higher integrity than DNA isolated from stools of patients with healthy colonic mucosa.Methods: We purified DNA from the stools of a colonoscopy-negative control group and patients with CRC and examined the relationship between long DNA fragments and clinical status by determining stool DNA integrity, using oligonucleotide-based hybrid captures with specific target sequences in increasingly long PCR reactions (200 bp, 400 bp, 800 bp, 1.3 kb, 1.8 kb, 24 kb). DNA fragments obtained from CRC patients were compared with fragments obtained from colonoscopy-negative individuals for length and/or integrity.Results: DNA fragments isolated from CRC patients were of higher molecular weight (>18 bands detected of a total of 24 possible bands) than fragments isolated from fecal DNA of the colonoscopy-negative control group.Conclusions: The presence of long DNA fragments in stool is associated with CRC and may be related to disease-associated differences in the regulation of proliferation and apoptosis. An assay of fecal DNA integrity may be a useful biomarker for the detection of CRC.
Liquid Chromatography–Tandem Mass Spectrometry Method for the Determination of Vanillylmandelic Acid in Urine
Magera, Mark J , Thompson, Abby L, Matern, Dietrich , Rinaldo, Piero

Clinical Chemistry | February 13, 2004 | Volume: 49 | Issue: 5 | Pages: 825-826

10.1373/49.5.825 | PMID 12709381 Get It

National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Recommendations for the Use of Laboratory Tests to Support Poisoned Patients Who Present to the Emergency Department
Wu, Alan H.B. , McKay, Charles, Broussard, Larry A. , Kwong, Tai C., Moyer, Thomas P. , Otten, Edward M., Welch, Shirley L., Wax, Paul M., Hoffman, Robert S.

Clinical Chemistry | February 13, 2004 | Volume: 49 | Issue: 3 | Pages: 357-379

10.1373/49.3.357 | PMID 12600948 Get It

AbstractBackground: Exposure to drugs and toxins is a major cause for patients’ visits to the emergency department (ED).Methods: Recommendations for the use of clinical laboratory tests were prepared by an expert panel of analytical toxicologists and ED physicians specializing in clinical toxicology. These recommendations were posted on the world wide web and presented in open forum at several clinical chemistry and clinical toxicology meetings.Results: A menu of important stat serum and urine toxicology tests was prepared for clinical laboratories who provide clinical toxicology services. For drugs-of-abuse intoxication, most ED physicians do not rely on results of urine drug testing for emergent management decisions. This is in part because immunoassays, although rapid, have limitations in sensitivity and specificity and chromatographic assays, which are more definitive, are more labor-intensive. Ethyl alcohol is widely tested in the ED, and breath testing is a convenient procedure. Determinations made within the ED, however, require oversight by the clinical laboratory. Testing for toxic alcohols is needed, but rapid commercial assays are not available. The laboratory must provide stat assays for acetaminophen, salicylates, co-oximetry, cholinesterase, iron, and some therapeutic drugs, such as lithium and digoxin. Exposure to other heavy metals requires laboratory support for specimen collection but not for emergent testing.Conclusions:Improvements are needed for immunoassays, particularly for amphetamines, benzodiazepines, opioids, and tricyclic antidepressants. Assays for new drugs of abuse must also be developed to meet changing abuse patterns. As no clinical laboratory can provide services to meet all needs, the National Academy of Clinical Biochemistry Committee recommends establishment of regional centers for specialized toxicology testing.
Capillary Electrophoresis Method to Measure p-Aminohippuric Acid in Urine and Plasma for the Assessment of Renal Plasma Flow
Ladwig, Paula M. , Bergert, Jan H., Larson, Timothy S.

Clinical Chemistry | February 12, 2004 | Volume: 49 | Issue: 4 | Pages: 664-666

10.1373/49.4.664 | PMID 12651825 Get It

Accuracy of detecting irregular cardiac rhythms via telemedicine
Zenk, Brenda M, Bratton, Robert L., Flipse, Thomas R, Page, E, Zenk, B.

Journal of Telemedicine and Telecare | February 10, 2004 | Volume: 10 | Issue: 1 | Pages: 55-58

10.1258/135763304322764211 | PMID 15006218 Get It

We evaluated the accuracy of an electronic stethoscope in the detection of irregular cardiac rhythms. Ten patients with either normal sinus rhythm or atrial fibrillation previously documented by electrocardiogram (ECG) were recruited from a local retirement community. Six senior family medicine resident physicians were asked to assess the cardiac rhythms of the subjects as either regular or irregular, in both a telemedical and an in-person examination. An ECG was obtained simultaneously as the gold standard. Forty-five of the 60 in-person assessments were correct, as were 49 of the 60 telemedicine assessments. The difference was not significant. Physician confidence in telemedical examination did not affect the accuracy of examination. The results of this study suggest that telemedicine-directed auscultation of patients may be just as successful as inperson examination for the detection of cardiac arrhythmias.
Modulation of Calcium Signaling by Interleukin-13 in Human Airway Smooth Muscle
Doğan, Soner , Walseth, Timothy F. , Miller, Steven M. , Amrani, Yassine , Panettieri, Reynold A. , Kannan, Mathur , Deshpande, Deepak A.

American Journal of Respiratory Cell and Molecular Biology | February 9, 2004 | Volume: 31 | Issue: 1 | Pages: 36-42

10.1165/rcmb.2003-0313oc | PMID 14764428 Get It

Abstract CD38/cyclic adenosine diphosphate ribose (cADPR) signaling plays an important role in the regulation of intracellular calcium responses to agonists in a variety of cells, including airway smooth muscle (ASM) cells. The present study was aimed at determining the effect of interleukin (IL)-13, a cytokine implicated in the pathogenesis of asthma, on CD38/cADPR signaling and to ascertain the contribution of CD38/cADPR signaling to IL-13–induced airway hyperresponsiveness. Human ASM cells maintained in culture were exposed to 50 ng/ml IL-13 for 22 h and levels of CD38 expression and intracellular calcium responses to agonists were measured. Treatment of human ASM cells with IL-13 resulted in increased CD38 expression as determined by real-time polymerase chain reaction, Western blot analysis, and indirect immunofluorescence. Increased CD38 expression was reflected as increased ADP-ribosyl cyclase activity in the ASM cell membranes. The net intracellular calcium responses to bradykinin, thrombin, and histamine were significantly (P ≤ 0.05) higher in cells treated with IL-13 compared with controls. Furthermore, 8-bromo-cADPR, a cADPR antagonist, attenuated IL-13–induced augmented intracellular calcium responses to agonists in human ASM cells. These findings indicate that the CD38/cADPR–dependent pathway has a major role in IL-13–induced modulation of calcium signaling in human ASM.
Cardiology Workforce: A Shortage, Not A Surplus
Fye, W. Bruce

Health Affairs | February 9, 2004 | Volume: 23 | Issue: Suppl1 | Pages: W4-64-W4-66

10.1377/hlthaff.w4.64 | PMID 15451974 Get It

Multicenter Evaluation of the VERSANT Hepatitis B Virus DNA 3.0 Assay
Yao, Joseph D. , Beld, Marcel, Oon, Lynette Lin Ean , Sherlock, Christopher H., Germer, Jeffrey J., Menting, Sandra, Thoe, Su Yun Se, Merrick, Linda, Ziermann, Rainer, Surtihadi, Johan, Hnatyszyn, H. James

Journal of Clinical Microbiology | February 6, 2004 | Volume: 42 | Issue: 2 | Pages: 800-806

10.1128/jcm.42.2.800-806.2004 | PMID 14766856 Get It

ABSTRACT The VERSANT hepatitis B virus (HBV) 3.0 Assay (branched DNA [bDNA]) (referred to herein as VERSANT 3.0) was evaluated at four external sites for analytical sensitivity, specificity, reproducibility, linearity of quantification, and limits of detection. In addition, each of the test evaluation sites provided HBV DNA-positive clinical samples that were previously analyzed by one of three commercially available HBV DNA quantitative tests: Digene Hybrid Capture II HBV DNA Test (Digene); VERSANT HBV DNA 1.0 Assay (bDNA) (VERSANT 1.0); and COBAS AMPLICOR HBV Monitor Test (COBAS AMPLICOR). These samples were reexamined using VERSANT 3.0. The results from these studies showed that VERSANT 3.0 has high specificity (99.3%), excellent reproducibility (between-run coefficient of variation [CV] = 1.6 to 9.4%; within-run CV = 6.5 to 20.7%), and a broad linear range of quantification (2.0 × 10 3 to 1.0 × 10 8 HBV DNA copies/ml) that facilitate the monitoring of HBV DNA levels at diagnosis and throughout the course of treatment. In general, correlation was very good between results obtained from clinical samples analyzed by VERSANT 3.0 and the comparative HBV DNA quantitative assays (VERSANT 1.0, R 2 = 0.900; Digene, R 2 = 0.985; COBAS AMPLICOR, R 2 = 0.771). The greatest differences in comparative quantitation occurred at HBV DNA levels approaching the limits of the dynamic ranges for the comparative assays. The performance characteristics of the new VERSANT 3.0 assay demonstrated that it provides a reliable and robust method for routinely monitoring serum HBV DNA levels in assessing disease activity and determining response to antiviral treatment.
Experience with the MicroSeq D2 Large-Subunit Ribosomal DNA Sequencing Kit for Identification of Filamentous Fungi Encountered in the Clinical Laboratory
Hall, Leslie, Wohlfiel, Sherri L., Roberts, Glenn D.

Journal of Clinical Microbiology | February 6, 2004 | Volume: 42 | Issue: 2 | Pages: 622-626

10.1128/jcm.42.2.622-626.2004 | PMID 14766826 Get It

ABSTRACT Described herein is our experience with the MicroSeq D2 large-subunit rDNA sequencing kit for the identification of filamentous fungi encountered in the mycology laboratory at the Mayo Clinic. A total of 234 filamentous fungi recovered from clinical specimens were used in the evaluation. All were identified by using phenotypic characteristics as observed macroscopically and microscopically on any medium or a combination of media, which included Sabouraud's dextrose, inhibitory mold, cornmeal, Czapek-Dox, potato dextrose, and V8 juice agars; all isolates were sequenced using the MicroSeq D2 large-subunit rDNA sequencing kit. Of the of 234 isolates, 158 were correctly identified to the appropriate genus or genus and species by using nucleic acid sequencing. Sequences for 70 (29.9%) of the isolates (27 genera) were not included in the MicroSeq library. Of the 80 dematiaceous and 154 hyaline fungi sequenced, 65 and 51.2%, respectively, gave results concordant with those determined by phenotypic identification. Nucleic acid sequencing using the MicroSeq D2 large-subunit rDNA sequencing kit offers promise of being an accurate identification system; however, the associated library needs to include more of the clinically important genera and species.
Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma
Nelson, Robert E., Grebe, Stefan K., O’Kane, Dennis J., Singh, Ravinder J.

Clinical Chemistry | February 3, 2004 | Volume: 50 | Issue: 2 | Pages: 373-384

10.1373/clinchem.2003.025478 | PMID 14656902 Get It

Abstract Background: Estradiol (E2) and estrone (E1) measurements form an integral part of the assessment of female reproductive function and have expanding roles in other fields. However, many E1 and E2 immunoassays have limited functional sensitivity, suffer from cross-reactivity, and display poor intermethod agreement. To overcome these problems, we developed a sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous measurement of E1 and E2. Methods: After dansyl chloride derivatization, samples were separated by fast gradient chromatography and injected into a tandem mass spectrometer after formation of positive ions with atmospheric pressure chemical ionization. The limits of detection and quantification, recovery, linearity, precision, and reference intervals were determined, and performance was compared with several immunoassays. Results: Total run time per sample was 5 min. The multiple-reaction monitoring ion pairs were m/z 506/171 for 3-dansyl-estradiol and m/z 504/171 for 3-dansyl-estrone. The limits of detection for E1 and E2 were 12.9 pmol/L (3.5 ng/L) and 10.3 pmol/L (2.8 ng/L), respectively. Interassay imprecision (CV) was 4–20% (n = 20). The limits of quantification (functional sensitivities) for E1 and E2 were 44.1 pmol/L (11.9 ng/L) and 23.2 pmol/L (6.3 ng/L), respectively. The assay was linear to >2200 pmol/L (∼600 ng/L) for each analyte. Recoveries were 93–108% for E1 and 100–110% for E2. No cross-reactivity was observed. Method comparison with several immunoassays revealed that the latter were inaccurate and prone to interferences at low E1 and E2 concentrations. Conclusions: LC-MS/MS allows rapid, simultaneous, sensitive, and accurate quantification of E1 and E2 in human serum.