Back to Authors

Helgeson, Scott A.

https://orcid.org/0000-0001-7590-2293

Mayo Clinic

Pulmonary and Critical Care Medicine

Citations 67

Deterioration Scores in Covid-19 Delta Variant
Bhakta, Shivang , Franco, Pablo Moreno , Helgeson, Scott A.

C47. PREDICTORS OF COVID OUTCOMES | May 24, 2022 | Volume: No volume available | Issue: No issue available | Pages: A5729-A5729

10.1164/ajrccm-conference.2022.205.1_meetingabstracts.a5729 Get It

Remote 6-minute-Walk Testing in Patients with Pulmonary Hypertension: Further Validation Needed?
Helgeson, Scott A. , Moss, John E. , Zeiger, Tonya K., Taylor, Bryan J , Helgeson, Scott A , Burger, Charles D. , Taylor, Bryan J.

American Journal of Respiratory and Critical Care Medicine | May 24, 2022 | Volume: 206 | Issue: 5 | Pages: 650-651

10.1164/rccm.202204-0762le Get It

Association Between Submaximal Exercise Gas Exchange and Clinical Worsening Events in Patients with Pulmonary Arterial Hypertension
Call, Justin T. , Saunders, Hollie , Zeiger, Tanya, Moss, James , Burger, C.D., Taylor, Bryan J. , Helgeson, Scott A.

B106. UNION SQUARE: OBSERVATIONAL STUDIES AND CLINICAL TRIALS IN PULMONARY HYPERTENSION | May 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: A3602-A3602

10.1164/ajrccm-conference.2022.205.1_meetingabstracts.a3602 Get It

Comparing Diagnosis and Treatment of Pulmonary Hypertension Patients at a Pulmonary Hypertension Center versus Community Centers
Saunders, Hollie , Helgeson, Scott A. , Abdelrahim, Ahmed, Rottman-Pietrzak, Kathleen, Reams, Victoria , Zeiger, Tonya K., Moss, John E. , Burger, Charles D. , Helgeson, Scott A , Burger, Charles , Abdelrahim, Ahmed

Diseases | January 7, 2022 | Volume: 10 | Issue: 1 | Pages: 5

10.3390/diseases10010005 Get It

Once patients are diagnosed with pulmonary hypertension it is important to identify the correct diagnostic group as it will have implications on the disease state management. Pulmonary hypertension is increasingly diagnosed and treated in general medical practices; however, evidence-based guidelines recommend evaluation and treatment in pulmonary hypertension centers for accurate diagnosis and appropriate treatment recommendations. We conducted a retrospective cohort study of 509 random patients 18 years and older who were evaluated in our pulmonary hypertension clinic from January 2005 to December 2018. 68.4% (n = 348) had their diagnostic group clarified or changed. Pulmonary hypertension was deemed an incorrect diagnosis in 12.4% (n = 63). A total of 114 patients (22.4%) had been initiated on pulmonary hypertension specific treatment prior to presentation. Pulmonary hypertension specific medication was stopped in 57 (50.0%) cases. The estimated monthly saving of the stopped medication based on wholesale acquisition costs was USD 396,988.05–419,641.05, a monthly saving of USD 6964.70–7362.12 per patient. Evaluation outside of a pulmonary hypertension center may lead to misdiagnosis and inappropriate or inadequate treatment. Pulmonary arterial hypertension directed therapy improves median survival, but inappropriate therapy may cause harm; therefore, patients benefit from a specialized center with multiple resources to secure an accurate diagnosis and tailored treatment for their condition.
Aerosol Generation and Mitigation During Methacholine Bronchoprovocation Testing: Infection Control Implications in the Era of COVID-19
Subat, Yosuf W., Hainy, Matthew E, Torgerud, Keith D, Sajgalik, Pavol , Guntupalli, Siva Kamal, Johnson, Bruce D. , Kim, Chul‐Ho , Scanlon, Paul D., Chul-Ho, Kim, Lim, Kaiser G. , Helgeson, Scott A. , Niven, Alexander S.

Respiratory Care | November 17, 2021 | Volume: 66 | Issue: 12 | Pages: 1858-1865

10.4187/respcare.09236 Get It

BACKGROUND: Methacholine bronchoprovocation or challenge testing (MCT) is commonly performed to assess airway hyper-responsiveness in the setting of suspected asthma. Nebulization is an aerosol-generating procedure, but little is known about the risks of MCT in the context of the ongoing coronavirus disease 2019 (COVID-19) pandemic. We aimed to quantify and characterize aerosol generation during MCT by using different delivery methods and to assess the impact of adding a viral filter. METHODS: Seven healthy subjects performed simulated MCT in a near particle-free laboratory space with 4 different nebulizers and with a dosimeter. Two devices continuously sampled the ambient air during the procedure, which detected ultrafine particles, from 0.02–1 μm, and particles of sizes 0.3, 0.5, 1.0, 2.0, 5.0, and 10 µm, respectively. Particle generation was compared among all the devices, with and without viral filter placement. RESULTS: Ultrafine-particle generation during simulated MCT was significant across all the devices. Ultrafine-particle (0.02–1 μm) concentrations decreased 77%–91% with the addition of a viral filter and varied significantly between unfiltered (P < .001) and filtered devices (P < .001). Ultrafine-particle generation was lowest when using the dosimeter with filtered Hudson nebulizer (1,258 ± 1,644 particle/mL). Ultrafine-particle concentrations with the filtered nebulizer devices using a compressor were higher than particle concentrations detected when using the dosimeter: Monaghan (3,472 ± 1,794 particles/mL), PARI (4,403 ± 2,948), Hudson (6,320 ± 1,787) and AirLife (9,523 ± 5,098). CONCLUSIONS: The high particle concentrations generated during MCT pose significant infection control concerns during the COVID-19 pandemic. Particle generation during MCT was significantly reduced by using breath-actuated delivery and a viral filter, which offers an effective mitigation strategy.
The Effect of the COVID-19 Pandemic on Pulmonary Diagnostic Procedures
Call, Justin T. , Lee, Augustine S. , Helgeson, Scott A. , Helgeson, Scott A , Haendel, Melissa , Chute, Christopher G.

Annals of the American Thoracic Society | November 17, 2021 | Volume: 19 | Issue: 4 | Pages: 695-697

10.1513/annalsats.202108-943rl Get It

Aerosol Generation During Peak Flow Testing: Clinical Implications for COVID-19
Subat, Yosuf W., Guntupalli, Siva Kamal, Sajgalik, Pavol , Hainy, Matthew E, Torgerud, Keith D, Johnson, Bruce D. , Allison, Thomas G. , Helgeson, Scott A. , Lim, Kaiser G. , Niven, Alexander S.

Respiratory Care | May 25, 2021 | Volume: 66 | Issue: 8 | Pages: 1291-1298

10.4187/respcare.08731 Get It

BACKGROUND: Peak flow testing is a common procedure performed in ambulatory care. There are currently no data regarding aerosol generation during this procedure. Given the ongoing debate regarding the potential for aerosol transmission of SARS-CoV-2, we aimed to quantify and characterize aerosol generation during peak flow testing. METHODS: Five healthy volunteers performed peak flow maneuvers in a particle-free laboratory space. Two devices continuously sampled the ambient air during the procedure. One device can detect ultrafine particles 0.02–1 μ m in diameter, while the second device can detect particles 0.3, 0.5, 1.0, 2.0, 5.0, and 10 μ m in diameter. Five different peak flow meters were compared to ambient baseline during masked and unmasked tidal breathing. RESULTS: Ultrafine particles (0.02–1 μ m) were generated during peak flow measurement. There was no significant difference in ultrafine particle mean concentration between peak flow meters ( P = .23): Respironics (1.25 ± 0.47 particles/mL), Philips (3.06 ± 1.22), Clement Clarke (3.55 ± 1.22 particles/mL), Respironics Low Range (3.50 ± 1.52 particles/mL), and Monaghan (3.78 ± 1.31 particles/mL). Ultrafine particle mean concentration with peak flow testing was significantly higher than masked (0.22 ± 0.29 particles/mL) and unmasked tidal breathing (0.15 ± 0.18 particles/mL, P = .01), but the ultrafine particle concentrations were small compared to ambient particle concentrations in a pulmonary function testing room (89.9 ± 8.95 particles/mL). CONCLUSIONS: In this study, aerosol generation was present during peak flow testing, but concentrations were small compared to the background particle concentration in the ambient clinical environment. Surgical masks and eye protection are likely sufficient infection control measures during peak expiratory flow testing in asymptomatic patients with well controlled respiratory symptoms, but COVID-19 testing remains prudent in patients with acute respiratory symptoms prior to evaluation and peak expiratory flow assessment while the community prevalence of SARS-CoV-2 cases remains high.
Aerosol Generation During Peak Flow Testing: Clinical Implications During the COVID-19 Pandemic
Subat, Yosuf W., Guntupalli, Siva Kamal, Sajgalik, Pavol , Hainy, M., Johnson, Bridgette, Helgeson, Scott A. , Niven, Alexander S.

TP117. TP117 COVID-19 PATHOPHYSIOLOGY AND MODELLING | May 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: A4474-A4474

10.1164/ajrccm-conference.2021.203.1_meetingabstracts.a4474 Get It

Aerosol Generation During Methacholine Challenge Testing: Clinical Implications During the COVID-19 Pandemic
Subat, Yosuf W., Sajgalik, Pavol , Hainy, M., Torgerud, Keith D, Guntupalli, Siva Kamal, Scanlon, Paul D., Johnson, Bridgette, Helgeson, Scott A. , Johnston, J., Niven, Alexander S.

TP117. TP117 COVID-19 PATHOPHYSIOLOGY AND MODELLING | May 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: A4473-A4473

10.1164/ajrccm-conference.2021.203.1_meetingabstracts.a4473 Get It

Transbronchial Forceps Biopsy in the Intensive Care Unit
Burnside, Rebecca, Fernández-Bussy, Sebastián , Brigham, Tara , Patel, Neal M. , Brigham, Tara J, Brigham, T J , Helgeson, Scott A. , Imam, J. Saadi

Journal of Bronchology & Interventional Pulmonology | March 24, 2021 | Volume: 28 | Issue: 4 | Pages: 281-289

10.1097/lbr.0000000000000767 Get It

Background: A transbronchial forceps lung biopsy performed in mechanically ventilated patients with respiratory failure of unknown etiology has significant uncertainty of diagnostic yield and safety along with sparse literature. This study investigated the complication rate of transbronchial biopsies in mechanically ventilated patients in the intensive care unit and its ability to obtain a diagnosis and change current therapy. Methods: PubMed, Ovid MEDLINE, and Ovid Cochrane Central Register of Controlled Trials databases were systematically searched for all publications of transbronchial lung biopsies in mechanically ventilated patients. We pooled the results of individual studies using random-effects meta-analysis models to achieve the summary proportions. Results: Of the identified 9 observational studies with a total of 232 patients undergoing a transbronchial biopsy, complications occurred in 67 patients [25.2%; 95% confidence interval (CI), 11.5%-42.0%; I 2=70.0%]. Pneumothorax occurred in 24 patients (9.5%; 95% CI, 4.5%-16.2%; I 2=15.9%) and bleeding in 18 patients (8.9%; 95% CI, 4.1%-15.3%; I 2=0%). A diagnosis was given in 146 patients (62.9%; 95% CI, 56.0%-69.1%; I 2=74.6%), with 103 of 210 patients (49.0%; 95% CI, 44.6%-55.1%; I 2=74.9%) having a change in treatment. Conclusion: The results of this meta-analysis suggest that a transbronchial forceps biopsy when performed in mechanically ventilated patients with respiratory failure of unclear etiology had a moderate complication rate. These biopsies resulted in varied diagnoses with a high rate of management change. Randomized controlled trials are necessary to identify the ideal patients to perform a transbronchial forceps biopsy on in the intensive care unit.