OBJECTIVE The American Spine Registry (ASR) is a collaborative effort between the American Academy of Orthopaedic Surgeons and the American Association of Neurological Surgeons. The goal of this study was to evaluate how representative the ASR is of the national practice with spinal procedures, as recorded in the National Inpatient Sample (NIS). METHODS The authors queried the NIS and the ASR for cervical and lumbar arthrodesis cases performed during 2017–2019. International Classification of Diseases, 10th Revision and Current Procedural Terminology codes were used to identify patients undergoing cervical and lumbar procedures. The two groups were compared for the overall proportion of cervical and lumbar procedures, age distribution, sex, surgical approach features, race, and hospital volume. Outcomes available in the ASR, such as patient-reported outcomes and reoperations, were not analyzed due to nonavailability in the NIS. The representativeness of the ASR compared to the NIS was assessed via Cohen’s d effect sizes, and absolute standardized mean differences (SMDs) of < 0.2 were considered trivial, whereas > 0.5 were considered moderately large. RESULTS A total of 24,800 arthrodesis procedures were identified in the ASR for the period between January 1, 2017, and December 31, 2019. During the same time period, 1,305,360 cases were recorded in the NIS. Cervical fusions comprised 35.9% of the ASR cohort (8911 cases) and 36.0% of the NIS cohort (469,287 cases). The two databases presented trivial differences in terms of patient age and sex for all years of interest across both cervical and lumbar arthrodeses (SMD < 0.2). Trivial differences were also noted in the distribution of open versus percutaneous procedures of the cervical and lumbar spine (SMD < 0.2). Among lumbar cases, anterior approaches were more common in the ASR than in the NIS (32.1% vs 22.3%, SMD = 0.22), but the discrepancy among cervical cases in the two databases was trivial (SMD = 0.03). Small differences were illustrated in terms of race, with SMDs < 0.5, and a more significant discrepancy was identified in the geographic distribution of participating sites (SMDs of 0.7 and 0.74 for cervical and lumbar cases, respectively). For both of these measures, SMDs in 2019 were smaller than those in 2018 and 2017. CONCLUSIONS The ASR and NIS databases presented a very high similarity in proportions of cervical and lumbar spine surgeries, as well as similar distributions of age and sex, and distribution of open versus endoscopic approach. Slight discrepancies in anterior versus posterior approach among lumbar cases and patient race, and more significant discrepancies in geographic representation were also identified, yet decreasing trends in differences suggested the improving representativeness of the ASR over the course of time and its progressive growth. These conclusions are important to underline the external validity of quality investigations and research conclusions to be drawn from analyses in which the ASR is used.
A component method to delineate surgical spine implants for proton Monte Carlo dose calculation
AbstractPurposeMetallic implants have been correlated to local control failure for spinal sarcoma and chordoma patients due to the uncertainty of implant delineation from computed tomography (CT). Such uncertainty can compromise the proton Monte Carlo dose calculation (MCDC) accuracy. A component method is proposed to determine the dimension and volume of the implants from CT images.MethodsThe proposed component method leverages the knowledge of surgical implants from medical supply vendors to predefine accurate contours for each implant component, including tulips, screw bodies, lockers, and rods. A retrospective patient study was conducted to demonstrate the feasibility of the method. The reference implant materials and samples were collected from patient medical records and vendors, Medtronic and NuVasive. Additional CT images with extensive features, such as extended Hounsfield units and various reconstruction diameters, were used to quantify the uncertainty of implant contours.ResultsFor in vivo patient implant estimation, the reference and the component method differences were 0.35, 0.17, and 0.04 cm3for tulips, screw bodies, and rods, respectively. The discrepancies by a conventional threshold method were 5.46, 0.76, and 0.05 cm3, respectively. The mischaracterization of implant materials and dimensions can underdose the clinical target volume coverage by 20 cm3for a patient with eight lumbar implants. The tulip dominates the dosimetry uncertainty as it can be made from titanium or cobalt–chromium alloys by different vendors.ConclusionsA component method was developed and demonstrated using phantom and patient studies with implants. The proposed method provides more accurate implant characterization for proton MCDC and can potentially enhance the treatment quality for proton therapy. The current proof‐of‐concept study is limited to the implant characterization for lumbar spine. Future investigations could be extended to cervical spine and dental implants for head‐and‐neck patients where tight margins are required to spare organs at risk.
Frequency and Acceptability of Adverse Events After Anterior Cervical Discectomy and Fusion
Purpose: Anterior cervical discectomy and fusion has a low but well-established profile of adverse events. The goal of this study was to gauge surgeon opinion regarding the frequency and acceptability of these events. Methods: A 2-page survey was distributed to attendees at the 2015 Cervical Spine Research Society (CSRS) meeting. Respondents were asked to categorize 18 anterior cervical discectomy and fusion–related adverse events as either: “common and acceptable,” “uncommon and acceptable,” “uncommon and sometimes acceptable,” or “uncommon and unacceptable.” Results were compiled to generate the relative frequency of these responses for each complication. Responses for each complication event were also compared between respondents based on practice location (US vs. non-US), primary specialty (orthopedics vs. neurosurgery) and years in practice. Results: Of 150 surveys distributed, 115 responses were received (76.7% response rate), with the majority of respondents found to be US-based (71.3%) orthopedic surgeons (82.6%). Wrong level surgery, esophageal injury, retained drain, and spinal cord injury were considered by most to be unacceptable and uncommon complications. Dysphagia and adjacent segment disease occurred most often, but were deemed acceptable complications. Although surgeon experience and primary specialty had little impact on responses, practice location was found to significantly influence responses for 12 of 18 complications, with non-US surgeons found to categorize events more toward the uncommon and unacceptable end of the spectrum as compared with US surgeons. Conclusions: These results serve to aid communication and transparency within the field of spine surgery, and will help to inform future quality improvement and best practice initiatives.