Back to Authors

Kella, Danesh

https://orcid.org/0000-0003-4657-1944

Mayo Clinic

Mayo Clinic in Florida

Citations 23

P2851Transvenous lead placement in the setting of venous obstruction: outcomes of tunneling technique versus venoplasty
Yasin, Omar , Padmanabhan, Deepak , Hodge, David O. , Cochuyt, Jordan J., Mulpuru, Siva K. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz748.1160 Get It

Abstract Background Venous stenosis is a well-recognized complication of transvenous leads when patients require lead revisions or device upgrade. In these cases, balloon venoplasty or alternative venous access with subcutaneous tunneling can be performed. Purpose Compare the outcomes of venoplasty vs. tunneling in patients requiring additional transvenous lead implantation. Methods A single center retrospective cohort study of all patients undergoing lead implantation/revision requiring venoplasty or tunneling from 2005–2017. Chi-squared and Wilcoxon Rank-Sum tests were used to compare categorical and continuous variables. Results Ninety five patients met our inclusion criteria (60 venoplasty & 35 tunneling). There was no difference in procedure success rates (p-value=0.98). Tunneling was associated with less fluoroscopy time but higher incidence of acute complications (0% vs. 23%, p-value=0.002) most requiring invasive intervention and/or blood product transfusion. Long term outcomes were comparable and related to lead failure or infection. Outcomes for tunneling vs. venoplasty Variable Tunneling (n=35) Venoplasty (n=60) p-value Age Y 67 (23–84) 70 (29–91) 0.25 Male (%) 24 (69%) 41 (68%) 0.98 Number of existing leads 2.1 (1–4) 2.4 (0–4) 0.1 Age of oldest lead 7.0 (0–21) 7.2 (0–33) 0.73 Number of new leads 1.2 (1–3) 1.4 (1–3) 0.26 Fluoroscopy time (SD) min 29.2 (21.3) 39.7 (21.5) 0.012 Procedure success (%) 35 (100%) 55 (92%) 0.9 Acute complications (%) 8 (23%)1 0 (0%) 0.0002 Pocket hematoma/bleed 4 (11%)2 Hemothorax 2 (6%)3 Pericarditis 1 (3%) Lead compromise 1 (3%) Follow up M 18 (0–76) 28 (0–98) N/A Long term lead issues (%) 6 (17%) 10 (17%) 0.95 Long term complication requiring intervention 4 (11%) 8 (13%) N/A Procedure success: functional lead placed as a result of venoplasty or tunneling. 1Two patients required blood products. 2Two patients required invasive intervention. 3One patient required chest tube and the other ICU admission. Conclusions Balloon venoplasty is associated with similar rates of success and a less incidence of acute complications when compared subcutaneous tunneling. Acknowledgement/Funding NIH T32 Training Grant HL07111-40
P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
Padmanabhan, Deepak , Izath, A, Al‐Masry, Anas Abudan , Gamero, Sonia Fortin, Barout, Ahmad, Assaf, Yazan , Shetty, Devi Prasad , Asirvatham, S, Felmlee, Joel P. , Watson, Robert E. , Cha, Y, Friedman, Paul A. , Farwati, Medhat , Al-Masry, A, Kella, Danesh

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0698 Get It

Abstract Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None
Sudden cardiac arrest and ventricular arrhythmias following first type I myocardial infarction in the contemporary era
Amin, Mustapha, Kella, Danesh , Killu, Ammar M. , Padmanabhan, Deepak , Hodge, David O. , Golafshar, Michael A. , Chamberlain, Alanna M. , Lee, Justin Z. , Shen, Win‐Kuang , Friedman, Paul A. , Asirvatham, Samuel J. , Roger, Véronique L. , Mulpuru, Siva K. , Mulpuru, Siva K , Asirvatham, Samuel J , Kella, Danesh K , Chamberlain, Alanna M , Golafshar, Michael , Gersh, Bernard J.

Journal of Cardiovascular Electrophysiology | October 7, 2019 | Volume: 30 | Issue: 12 | Pages: 2869-2876

10.1111/jce.14218 Get It

AbstractIntroductionMyocardial infarction (MI) is associated with an increase in subsequent heart failure (HF), recurrent ischemic events, sudden cardiac arrest, and ventricular arrhythmias (SCA‐VA). The primary objective of the study to determine the role of intercurrent HF and ischemic events on the development of SCA‐VA following first type I MI.Methods and resultsA retrospective cohort study of patients experiencing first type 1 MI in Olmsted County, Minnesota (2002‐2012) was conducted by identifying patients using the medical records linkage system (Rochester epidemiology project). Patients aged ≥18 years were followed from the time of MI till death or 31 July, 2017. Intercurrent HF and ischemic events were the primary exposures following MI and their association with outcome SCA‐VA was assessed. Eight hundred and sixty‐seven patients (mean age was 63 ± 14.5 years; 69% male; 49.8% ST‐elevation myocardial infarction) who had their first type I MI during the study period were included. Majority of acute MI patients were revascularized using percutaneous coronary intervention and bypass surgery (628 [72.43%] and 87 [10.03%] respectively). During a mean follow‐up of 7.69 ± 4.17 years, HF, recurrent ischemic events and SCA‐VA occurred in 155 (17.9%), 245 (28.3%), and 40 (4.61%) patients respectively. Low ejection fraction (adjusted hazard ratio [HR] 0.95; 95% confidence interval [CI], 0.93‐0.98; P < .001), intercurrent HF (adjusted HR 3.11; 95% CI, 1.39‐6.95; P = .006) and recurrent ischemic events (adjusted HR 3.47; 95% CI, 1.68‐7.18; P < .001) were associated with subsequent SCA‐VA.ConclusionSCA‐VA occurred in a small proportion of patients after MI and is associated with intercurrent HF and recurrent ischemic events.
Lyme carditis atrioventricular block: management strategies—Authors’ reply
Isath, Ameesh , Padmanabhan, Deepak , Naksuk, Niyada , Kella, Danesh , Friedman, Paul A. , Kella, Danesh K

EP Europace | May 2, 2019 | Volume: 21 | Issue: 8 | Pages: 1282-1282

10.1093/europace/euz111 Get It

P5792Risks factors for dofetilide-associated torsades de pointes among hospitalized patients with atrial fibrillation
Naksuk, Niyada , Witt, Christoffer Tobias , Sugrue, Alan , DeSimone, Christopher V. , Witt, C, Kella, Danesh , Noseworthy, Peter A.

European Heart Journal | December 10, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy566.p5792 Get It

P3698Correlation of lead length with procedural safety outcomes of magnetic resonance imaging in patients with legacy pacemakers and defibrillators
Padmanabhan, Deepak , Naksuk, Niyada , Deshmukh, Abhishek , Mulpuru, Siva K. , Felmlee, Joel P. , Dalzell, Connie, Olson, Nora E., Jondal, Mary Lou, Watson, Robert E. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh , Kapa, Suraj , Asirvatham, Samuel J.

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p3698 Get It

Leadless pacemaker used as long-term temporary therapy in Lyme carditis with high-grade atrioventricular block
Isath, Ameesh , Padmanabhan, Deepak , Naksuk, Niyada , Kella, Danesh , Friedman, Paul A. , Kella, Danesh K

EP Europace | July 14, 2018 | Volume: 21 | Issue: 1 | Pages: 8-8

10.1093/europace/euy175 Get It

Fast and the Furious
Killu, Ammar M. , Kella, Danesh , Kapa, Suraj , Kella, Danesh K

Circulation: Arrhythmia and Electrophysiology | April 13, 2018 | Volume: 11 | Issue: 4 | Pages: No page available

10.1161/circep.118.006391 Get It

P1218Incidence and Risk Factors for Renal Dysfunction after Direct Current Cardioversion of Atrial Fibrillation
Grüner‐Hegge, Nicolai, Padmanabhan, Deepak , Mehta, Rajesh , Hodge, D, Meludini, R, Rihal, C., Mulpuru, Siva K. , Deshmukh, Abhishek , Ammash, Naser M., Greene, Eddie L., Friedman, Paul A. , Kella, Danesh , Mehta, R, Hodge, D

EP Europace | March 19, 2018 | Volume: 20 | Issue: suppl_1 | Pages: i239-i239

10.1093/europace/euy015.700 Get It

119Antiarrythmia Device use in Myotonic Dystrophy population: A Single Center Experience
Grüner‐Hegge, Nicolai, Padmanabhan, D, Hodge, D.O., Prado, J.J., Aguayo, Rolando Vega, Friedman, Paul J., Kella, Danesh

EP Europace | March 19, 2018 | Volume: 20 | Issue: suppl_1 | Pages: i17-i17

10.1093/europace/euy015.041 Get It