Back to Authors

Barout, Ahmad

Mayo Clinic

Mayo Clinic

Citations 2

Peak Systolic Blood Pressure During the Exercise Test: Reference Values by Sex and Age and Association With Mortality
Assaf, Yazan , Barout, Ahmad, Al-Mouakeh, Ahmad , Barillas-Lara, Maria Irene , Fortin-Gamero, Sonia, Bonikowske, Amanda R. , Pepine, Carl J. , Allison, Thomas G. , Allison, Thomas G , Alhamid, Ahmad Abdul Hakim

Hypertension | April 19, 2021 | Volume: 77 | Issue: 6 | Pages: 1906-1914

10.1161/hypertensionaha.120.16570 Get It

We sought to update norms for peak systolic blood pressure (SBP) on the graded exercise test and examine its prognostic value in patients without baseline cardiovascular disease. Mayo graded exercise test data (1993–2010) were reviewed for nonimaging tests using Bruce protocol, selecting Minnesota residents 30 to 79 years without baseline cardiovascular disease. We formed a pure cohort of patients without factors significantly affecting peak SBP to determine peak SBP percentile norms by age and sex. Then we divided the full cohort of patients into 5 groups based on peak SBP percentiles: low (<10th), borderline low (10th–25th), referent (25th–75th), borderline high (75th–90th), and high (>90th). The relationship between peak SBP and mortality was tested using Cox regression adjusting for age, sex, and comorbidities affecting peak SBP or mortality. We identified 20 760 eligible patients with 7313 females (35%) and mean age 51.5±10.7 years. Our pure cohort included 7810 patients. Over 12.5±5.0 years follow-up, there were 1582 deaths, including 541 cardiovascular deaths. In the fully adjusted model, low-peak SBP was associated with increased total mortality (heart rate, 1.41 [1.19–1.66], P <0.0001) and cardiovascular mortality (heart rate, 1.54 [1.16–2.03], P =0.001), while borderline low-peak SBP was associated with increased cardiovascular mortality only (heart rate, 1.36 [1.02–1.81], P =0.027). High peak SBP was associated with increased total mortality only in the age-sex adjusted model (heart rate, 1.18 [1.02–1.36], P =0.026), not after full adjustment. We conclude that low exercise peak SBP is an independent predictor of higher total and cardiovascular mortality.
P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
Padmanabhan, Deepak , Izath, A, Al‐Masry, Anas Abudan , Gamero, Sonia Fortin, Barout, Ahmad, Assaf, Yazan , Shetty, Devi Prasad , Asirvatham, S, Felmlee, Joel P. , Watson, Robert E. , Cha, Y, Friedman, Paul A. , Farwati, Medhat , Al-Masry, A, Kella, Danesh

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0698 Get It

Abstract Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None